• Title/Summary/Keyword: B-contraction

Search Result 275, Processing Time 0.029 seconds

Effects of Sopoongtang on the Cardiovascular System in the Experimental Animals (소풍탕(疎風湯)이 실험동물(實驗動物)의 심혈관계(心血管系)에 미치는 영향(影響))

  • Jeong, Jang-Gyun;Mun, Byeong-Sun
    • The Journal of Internal Korean Medicine
    • /
    • v.16 no.1
    • /
    • pp.197-213
    • /
    • 1995
  • The present experiment was desinged to investigate the effects of Sopungtang water extracts on the Cardiovascular System in the Experimental Animals. Thus, the changes of blood pressure and heart rate were measured after oral administration. Measurments of Mortality rate were observed for measuring the effect of Sopungtang water extract. Sopungtang water extract against pulmonary thromboembolism induced by collagen the mixture(0.1ml/10g, 2mg/kg B.W) plus serotonin(5mg/kg B.W) in mouse. The effects of Sopungtang water extract were examined by observing the change of collagen-induced platelet aggregation, coagulation activity, ex vivo and in vitro fibrinolytic activity of euglobulin fraction in rats. The results were summarized as followings. 1. Sopungtang dropped the blood pressure in spontaneous hypertensive rat. 2. The drug increased the auricular blood flow in rabbit. 3. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 4. The drug inhibited the death rate of mouse which was led to thromboembolism by serotonin and collagen. 5. The drug inhibited the platelet aggregation in rat. 6. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable. 7. The drug increased the antithrombin activity in rat and the fibrinogen lyses time was reduced and lyses area was increased. 8. Sopungtang reduced fibrinogen lyses time of rat in vitro assay. According to the above mentioned results, Sopungtang increased the blood flow and dropped the blood pressure by the dilation of blood vessel. And the drug presented the antithrombin acivity, inhibited the platelet aggregation.

  • PDF

New ADD Injection Driven Transonic Wind Tunnel and Test With the AGARD Model (신규 건설 ADD 천음속풍동 소개 및 AGARD 표준모형 공력계수 비교)

  • Seo, Kyugnwon;Lee, Jong Geon;Shin, Seongbeom;Han, Sang Hyun;Park, Keum Yong;Kim, Young Jun;Kim, Namgyun;Jin, Hyeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.2
    • /
    • pp.119-125
    • /
    • 2020
  • A high Reynolds number transonic wind tunnel has been built in 2018 at Agency for Defense Development(ADD). The tunnel has a closed circuit with a 1.5m×1.5m test section and is injection driven from a 140bar air supply system. The Mach number range is 0.3-1.2 with a conventional contracting nozzle and 1.4 with a convergent-divergent contraction. The stagnation pressure range is 100-550kPa at the lowest Mach number. An AGARD-B standard model is tested in the transonic wind tunnel to obtain 6-DOF aerodynamic coefficients. The results are compared with those obtained from ADD trisonic wind tunnel and others. We verify that the transonic wind tunnel become available to develop an aircraft from the testing results.

A study on the pressure loss coefficient of non-Newtonian fluids in the stenotic tubes (비뉴턴 유체의 협착관내 압력손실계수에 관한 연구)

  • Seo, Sang-Ho;Yu, Sang-Sin;Jang, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1603-1612
    • /
    • 1996
  • The pressure loss coefficient of Newtonian and non-Newtonian fluids such as water, aqueous solutions of Carbopol-934 and Separan AP-273 and blood in the stenotic tubes are determined experimentally and numerically. The numerical analyses for flows of non-Newtonian fluids in the stenotic tubes are conducted by the finite element method. The effect of the contraction ratio and the ratio of length to diameter on the pressure drop are investigated by the experiments and numerical analysis. The pressure loss coefficients are significantly dependent upon the Reynolds number in the laminar flow regime. As Reynolds number increases, the pressure loss coefficients of both Newtonian and non-Newtonian fluids decrease in the laminar flow regime. As the ratio of length to diameter increases the maximum pressure loss coefficient increases in the laminar flow regime for both Newtonian and non-Newtonian fluids. Newtonian fuid shows the highest values of pressure loss coefficient and blood the next, followed by Carbopol solution and Separan solution in order. Experimental results are used to verify the numerical analyses for flows of Newtonian and non-Newtonian fluids. Numerical results for the maximum pressure loss coefficient in the stenotic tubes are in fairly good agreement with the experimental results. The relative differences between the numerical and experimental results of the pressure loss coefficients in the laminar flow regime range from 0.5% to 14.8%.

An Experimental Study on Startup Characteristics of a Center Body Diffuser for High Altitude Simulation (고공환경 모사용 Center Body Diffuser의 시동 특성에 관한 실험적 연구)

  • Yeon, Hae In;You, Isang;Kim, Wan Chan;Im, Ji Nyeong;Ko, Young Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • An experimental study has been conducted to verify the startup characteristic of a Center Body Diffuser (CBD) for simulating a low pressure environment when at high altitudes. Vacuum chamber pressure and startup characteristics of the CBD were investigated according to various geometries of the center body structure by a cold gas flow test. The test results show that the startup pressure is lowest when the center body contraction angle is approximately $15^{\circ}$. The startup characteristic of the CBDs significantly improves when the diffuser inlet length ($L_d/D_d$) is decreasing and the divergence length ($L_s$) is increasing. Additionally, it is possible to simulate various high altitude, low pressure conditions for various rocket engines that have different nozzle expansion ratios by adjusting the center body's position inside the diffuser.

A Comparative Study of Sepiae Os, Arcae Concha, Ostreae Concha and Esomeprazole in a Mouse Model of Reflux Esophagitis (역류성 식도염 생쥐 모델에서 해표초, 와릉자, 모려와 Esomeprazole의 치료효과에 대한 비교 연구)

  • Song, Chang-Hun;Baek, Tae-Hyun
    • The Journal of Korean Medicine
    • /
    • v.39 no.2
    • /
    • pp.92-105
    • /
    • 2018
  • Objectives: This aim of this study is to compare the reflux esophagitis improvement effects of Sepiae Os, Arcae Concha, Ostreae Concha, and Proton Pump Inhibitor(esomeprazole) through rat experiments. Methods: NO production inhibitory effect was measured by NO production amount and iNOS mRNA expression level in cell lines. iNOS, $TNF-{\alpha}$ and $p-I{\kappa}B$, and serotonin were compared using immunohistochemistry at the rat reflux esophagitis. Reflux esophagitis connection external form, lower esophageal sphincter, and gap were observed and an esophageal inflammatory indicator, IL-6 activity was also evaluated by immunohistochemistry. Results: NO production and iNOS mRNA expression was showed concentration dependent decrease in cell lines treated with Sepiae OS, Arcae Concha, and Ostreae Concha at the experiments of cell lines. In the suppression of iNOS and $p-I{\kappa}B$ at the rat reflux esophagitis, Sepiae Os treat group(SOT) and Ostreae Concha treat group(OCT) were more effective. In the increase of serotonin at the rat reflux esophagitis, ACT, MT and OCT were more effective. Damage of lower esophageal sphincter, and gap between esophageal keratin and mucosa were observed less at the SOT, ACT, OCT. In the suppression of IL-6 at the rat reflux esophagitis, SOT and OCT were more effective than GE and, SOT was more effective than MT significantly. Conclusions: The anti-inflammatory effect was the best in the SOT and lower esophageal sphincter muscle contraction was the best in the ACT at the rat reflux esophagitis. Sepiae OS was more effective than esomeprazole in the suppression of iNOS, $TNF-{\alpha}$, and IL-6.

Performance Characteristics Under Non-Reacting Condition with Respect to Length of a Subscale Diffuser for High-Altitude Simulation (고고도 모사를 위한 축소형 디퓨저의 길이변화에 따른 비연소장에서의 성능특성)

  • Jeong, Bonggoo;Kim, Hong Jip;Jeon, Junsu;Ko, Youngsung;Han, Yeoung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.321-328
    • /
    • 2014
  • The performance characteristics of a subscale diffuser under non-reacting conditions for high-altitude simulation were numerically investigated with respect to different lengths of the secondary throat diffuser. The ratio of the length of the diffuser entrance to the nozzle exit diameter was set to 0, 50, and 100%. In addition, flow characteristics were studied for a range of length-to-diameter ratios of the secondary throat diffuser. An insufficient diffuser entrance length caused contraction of the plume immediately after the nozzle exit. When the length-to-diameter ratio was less than 8, a strong Mach disk was formed inside the diffuser, resulting in a sharp increase in pressure. In addition, flow characteristics in the diverging part of the diffuser were investigated for a range of diverging part lengths. A short diverging part may lead to abrupt pressure recovery, resulting in the possible application of mechanical load to the diffuser.

Characterization of Proteins in the Muscle of Limanda yokohamae from the Masan Bay, Korea

  • Kim, Soo-Woon;Kim, Sam-Moon;Lee, Dong-Kun;Moon, Hyo-Bang;Choi, Hee-Gu;Kang, Chang-Keun;Choe, Eun-Sang
    • Ocean Science Journal
    • /
    • v.42 no.2
    • /
    • pp.129-134
    • /
    • 2007
  • Increasing industrial development in the Masan Bay area of Korea over the past decades increased the risk for the survival of marine organisms in the bay area by the deterioration of the water quality. Since living organisms have the ability to adapt contamination-associated stimuli by the alteration of gene expression, changes in proteins can be used as an important criterion for assessing the levels of environmental conditions. In this study, therefore, alterations of the expression of proteins in the muscle of Limanda yokohamae from Dukdong and Dotsum in the bay area were surveyed and characterized as compared with Haegumgang, which served as a control site. The results demonstrated that the twenty spots detected from Dukdong and Dotsum were similar to each other. Fifteen proteins were found to be predicted or undefined proteins, while five proteins were identified as heavy polypeptide 11 of myosin, apolipoprotein A-I, fibroblast growth factor 17b precursor, G protein-coupled receptor kinase 1 b and bonnie and clyde. These data suggest that local fish in the bay area have dysfunction in muscle physiology including contraction, lipid metabolism, proliferation and differentiation and nervous system.

Effects of Samsaengyeum on the Cardiovascular System in the Experimental Animal (삼생음(三生飮)이 실험동물(實驗動物)의 심혈관계(心血管系) 및 혈류장애개선(血流障碍改善)에 미치는 효과(效果))

  • Jeon, Heui-Jun;Choi, Cheol-Won;Sin, Sun-Ho;Sung, Gang-Kyung;Mun, Byung-Sun
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.299-315
    • /
    • 1997
  • The present experiments were designed to investigate the effects of Samsaengyeum. water extracts on the Cardiovascular System in the Experimental Animals. Thus, the changes of blood pressure and heart rate were measured after oral administration. Measurement of Mortality rate was observed for measuring the effect of Samsaengyeum water extract Samsaengyeum water extract against pulmonary thromboembolism induced by collagen the mixture(0.1me/10g, 2mg/kg B.W) plus serotonin(5mg/kg B.W) in mouse. The effect of Samsaengyeiim water extract was examined by observing the change of collagen-induced platelet aggregation, coagulation activity, ex vivo and in vitro fibrinolytic activity of euglobulin fraction in rats. The results were summarized as followings. 1. Samsaengyeum dropped the blood pressure in spontaneous hypertensive rat. 2. The drug increased the auricular blood flow in rabbit. 3. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 4. The drug inhibited the death rate of mouse which was led to thromboembolism by serotonin and collagen. 5. The drug inhibited the platelet aggregation in rat. 6. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable. 7. The drug reduced the fibrinogen lyses time and increased the lyses area of rat. 8. Samsaengyeum reduced fibrinogen lyses time of rat in vitro assay. According to the above mentioned results, Samsaengyeum increased the blood flow and dropped the blood pressure by the dilation of blood vessel. And the drug inhibited the platelet aggregation.

  • PDF

An Experimental Study on the Quality Properties of High Strength Concrete by the Replacement Ratio SFFB as Substitutes of Silica-fume (실리카 흄 대체재로 활용 가능한 SFFB의 치환율에 따른 고강도 콘크리트의 품질특성에 관한 실험적 연구)

  • Lim, Byung-Hoon;Lee, Sang-Soo;Yun, Hyun-Do;Yoon, Gil-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.87-92
    • /
    • 2010
  • This study set up 25, 35% for silica fume, SFFB's 2 level and water-combination material ratio, silica fume 10% for substitution ratio, and 4 level of SFFB 5, 10, 15(%) in order to compare and analyze the quality characteristic of ultra high strength concrete according to the substitution ratio of silica fume free binder (SFFB) that can be utilized as a substitute material for silica fume. As a result of an experimentation, the lower water-combination material ratio was, the higher addition ratio of high performance water-reducing agent for securing target liquidity increased, and it indicated the tendency that addition ratio of high performance water-reducing agent decreases because of material characteristic that SFFB has a lower absorptiveness than silica fume. The best strength was shown when SFFB substitution ratio is 10% at compressive strength and when substitution ratio is 15% at tensile strength, and it was indicated that at autogenous shrinkage contraction decreases compared to Plain(SF) regardless of substitution ratio of W/B and SFFB.

Comparison of Radiofrequency Ablation and Cryoablation for the Recovery of Atrial Contractility and Survival

  • Kim, Kang Min;Chung, Suryeun;Kim, Sang Yoon;Kim, Dong Jung;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.266-272
    • /
    • 2018
  • Background: Limited comparative data are available on the efficacy of cryoablation versus radiofrequency ablation in patients with atrial fibrillation. This study aimed to compare radiofrequency ablation and cryoablation with regard to clinical outcomes and the restoration of sinus rhythm or atrial contractility. Methods: A total of 239 patients who underwent surgical ablation between August 2003 and December 2016 at our institution were included. The patients were divided into 2 groups according to the energy device that was used (group A: n=140, radiofrequency ablator; group B: n=99, cryoablator). Echocardiographic data, overall survival, and major cardiovascular and cerebrovascular event (MACCE)-free survival were compared between the 2 groups. Results: At 1 year of follow-up, the atrial contractility recovery rate was 32.2% (19 of 59) in group A and 48.8% (21 of 44) in group B. In addition, cryoablation was found to be a predictive factor for the recovery of atrial contractility (cryoablation vs. radiofrequency ablation: odds ratio, 2.540; 95% confidence interval, 1.063-6.071; p=0.036). The left ventricular ejection fraction was significantly higher in group B ($53.1%{\pm}11.5%$ vs. $59.1%{\pm}6.3%$, p=0.001). The median follow-up duration was 36 months. The 5-year overall survival rate was $80.1%{\pm}3.6%$ in group A and $92.1%{\pm}2.9%$ in group B (p=0.400). The 5-year MACCE-free survival rate was $70.3%{\pm}4.0%$ in group A and $70.9%{\pm}5.6%$ in group B (p=0.818). Conclusion: Cryoablation was associated with a higher atrial contractility restoration rate and better left ventricular function than radiofrequency ablation. However, no significant relationship was observed between the energy source and overall or MACCE-free survival.