New ADD Injection Driven Transonic Wind Tunnel and Test With the AGARD Model

신규 건설 ADD 천음속풍동 소개 및 AGARD 표준모형 공력계수 비교

  • Received : 2019.12.04
  • Accepted : 2020.01.28
  • Published : 2020.02.01

Abstract

A high Reynolds number transonic wind tunnel has been built in 2018 at Agency for Defense Development(ADD). The tunnel has a closed circuit with a 1.5m×1.5m test section and is injection driven from a 140bar air supply system. The Mach number range is 0.3-1.2 with a conventional contracting nozzle and 1.4 with a convergent-divergent contraction. The stagnation pressure range is 100-550kPa at the lowest Mach number. An AGARD-B standard model is tested in the transonic wind tunnel to obtain 6-DOF aerodynamic coefficients. The results are compared with those obtained from ADD trisonic wind tunnel and others. We verify that the transonic wind tunnel become available to develop an aircraft from the testing results.

본 논문에서는 국방과학연구소에서 신규 건설한 천음속풍동을 소개하고 성능에 대하여 기술하였다. 천음속풍동은 인젝터구동(Injection Driven), 폐회로(Closed Circuit) 방식의 풍동으로 시험부 크기가 가로, 세로 각각 1.5m이다. 마하수는 0.3에서 1.2까지 연속적으로 변화가능하며, 노즐을 교체하여 마하수 1.4 실험이 가능하다. 풍동의 전압력(Total Pressure)을 100kPa에서 550kPa까지 변화시킬 수 있으며, 그에 따라 레이놀즈수(Reynolds Number)를 크게 변화시켜 실험을 수행할 수 있다. 풍동의 성능을 검증하기 위하여 AGARD-B 표준모형을 이용하여 6분력 공력계수 측정 실험을 수행하였으며, 그 결과를 국과연 삼중음속풍동 및 세계 여러 풍동의 실험결과와 비교 분석하였다.

Keywords

References

  1. Ahn, S. K., "Introduction of wind tunnel test in Agency for Defense Development," Journal of Computational Fluids Engineering, Vol. 9, No. 2, 2004, pp. 70-74.
  2. Torngren, L., "The FFA T1500 injection briven transonic wind tunnel," ICAS-90-6.2.3, 1990, PP. 388-398.
  3. Torngren, L., "The new FFA T1500 transonic wind tunnel innitial operation, calibration and test results," AIAA 90-1420, 1990.
  4. Hills, R., "A Review of Measurements on AGARD Calibration Models," AGARDograph 64, Nov, 1961.
  5. Yoo, C. J., "Wind tunnel Calibration testing Reports using AGARD-B model," ADD report, 1991.
  6. AIAA standard, "Assessment of Experimental Uncertainty with Application to Wind Tunnel Testing," AIAA S-071A-1999, 1999.
  7. Daneshmand, S., Aghanajafi, C., and Shahverdi, H., "Investigation of rapid manufacturing technology effect on aerodynamics properties," Tehnicki Vjesnik-Technical Gazette 20.3, 2013. p. 425-434.
  8. Dijana, D., et al., "Testing of AGARD-B calibration model in the T-38 trisonic wind tunnel," Scientific Technical Review 56.2, 2006, p. 52-62.
  9. Milillo, J. R., "Transonic Tests of an AGARD Model B and a Modified AGARD Model C at 0.01 percent Blockage," AEDC-TN-58-48, 1958.
  10. Whitfield, E. L., "Correlation of Longitudinal force data on an AGARD Model B in the Lockheed 4ft Wind Tunnel," April 1977.