• 제목/요약/키워드: B Coefficient

검색결과 2,883건 처리시간 0.026초

경제급전을 위한 B-계수와 조류계산에 의한 페널티계수 산정법의 개발 및 성능비교 (Penalty Factor Computation Algorithms for Economic Load Dispatch Based on B-Coefficient and AC Load Flow and their Performance Comparison)

  • 남해곤;문영환;최홍관;남궁재용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.206-209
    • /
    • 1999
  • This paper presents an improved method of calculating the penalty factors for economic load dispatch based on B-coefficient and AC load flow and their performance comparison. The algorithm for calculating B-coefficients by Meyer is improved and its performance is compared with that of AC load flow. The B-coefficient method is superior to the load flow method in its simplicity and computation speed. However accuracy of the B-coefficient method is not satisfactory when it is applied to the ill-conditioned systems where generators produce excessive reactive power.

  • PDF

Convolution Kernel의 종류에 따른 CT 감약계수 및 노이즈 측정에 관한 연구 (A Method to Obtain the CT Attenuation Coefficient and Image Noise of Various Convolution Kernels in the Computed Tomography)

  • 권대철;유병규;이종석;장근조
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.21-30
    • /
    • 2007
  • 영상 획득과 재구성 방법에 따라 CT 감약계수는 다양성을 보이고 관심 영역의 노이즈는 정밀도에 영향을 준다. 인체에서 간 실질조직과 위장의 물의 CT 감약계수와 노이즈를 커널에 따라 측정하였다. 다중채널 CT 스캐너를 이용하여 복부를 스캔 하였고, 커널은 B10 (very smooth), B20 (smooth), B30 (medium smooth), B40 (medium), B50 (medium sharp), B60 (sharp), B70 (very sharp), B80 (ultra sharp)으로 재구성하여 간의 실질 조직과 물이 들어 있는 위장 부위를 ROI 기능을 이용하여 평균의 CT감약계수와 표준편차인 노이즈를 측정하여 영상을 비교하였다. 간의 실질 조직에서 CT감약계수는 커널에 따라 60.4에서 69.2 HU사이에서 분포하여 차이가 없었으나, 노이즈는 커널(7.6$\sim$63.8 HU)이 높아질수록 증가하였다. 물의 CT감약계수는 -2.2 HU에서 0.8 HU사이에서 측정되었고, 노이즈는 커널(10.1$\sim$82.4 HU)이 높아질수록 증가하였다. 영상의 질을 높이기 위해서는 검사 부위에 따라 노이즈를 감소하기 위해 적절한 커널을 선택하여 CT 검사를 하여야 한다.

  • PDF

고주파 진공유도로로 제작한 p형 SiGe 합금의 열전변환물성 (The Thermoelectric Properties of p-type SiGe Alloys Prepared by RF Induction Furnace)

  • 이용주;배철훈
    • 한국세라믹학회지
    • /
    • 제37권5호
    • /
    • pp.432-437
    • /
    • 2000
  • Thermoelectric properties of p-type SiGe alloys prepared by a RF inductive furnace were investigated. Non-doped Si80Ge20 alloys were fabricated by control of the quantity of volatile Ge. The carrier of p-type SiGe alloy was controlled by B-doping. B doped p-type SiGe alloys were synthesized by melting the mixture of Ge and Si containing B. The effects of sintering/annealing conditions and compaction pressure on thermoelectric properties (electrical conductivity and Seebeck coefficient) were investigated. For nondoped SiGe alloys, electrical conductivity increased with increasing temperatures and Seebeck coefficient was measured negative showing a typical n-type semiconductivity. On the other hand, B-doped SiGe alloys exhibited positive Seebeck coefficient and their electrical conductivity decreased with increasing temperatures. Thermoelectric properties were more sensitive to compaction pressure than annealing time. The highest power factor obtained in this work was 8.89${\times}$10-6J/cm$.$K2$.$s for 1 at% B-doped SiGe alloy.

  • PDF

적조 원격탐사 기술 개발을 위한 적조생물의 광특성 연구 (A Study on Optical Properties of Red Tide Algal Species)

  • 이누리;문정언;안유환;양찬수;윤홍주
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.187-191
    • /
    • 2006
  • 적조 종에 따라 해색이 다르다는 점에 착안해 해색 모델로부터 적조 종을 역 추정하는 기술을 개발하는데 있어 기본 입력 변수가 되는 적조 생물에 관한 광학적 특성(흡수, 역산란 특성)을 연구하였다. 실험실 수준에서의 적조 생물의 광특성을 조사하기 위해서 남해에서 채취 된 21종의 적조 생물을 배양하고 spectrophotometer를 이용해 광합성 색소에 의한 흡수계수(absorption coefficient, a)와 역산란 계수 (backscattering coefficient, $b_b$)를 측정하였다. 또한 spectrophotometer를 이용해 측정된 흡수 및 역산란 계수와 클로로필 농도를 이용하여 비 흡광계수 $(a^*)$와 비역산란계수$(b_b^*)$를 계산하였으며 이들 스펙트럼의 모양과 값을 비교하였다. 적조 생물 종에 따른 $a^*$은 파장대 440nm 에서 $0.005-0.06m^2/mg$의 값을 가지며, $b_b^*$의 범위는 $10^{-2}\sim10^{-4}m^2/mg$로 종간 약 100배의 차이가 있었다. 이와 같이 적조생물 종에 따라 스펙트럼의 모양과 값에서 차이를 나타냈으며 21종의 적조 생물 중에서 해색 스펙트럼으로 종간 구분이 가능한 종은 7-8 종이었다. 이 결과는 해색모델 개발에 있어 입력변수로 활용될 것이다.

  • PDF

Friction of a Brownian Particle in a Lennard-Jones Solvent: A Molecular Dynamics Simulation Study

  • Lee, Song-Hi
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권4호
    • /
    • pp.959-964
    • /
    • 2010
  • In this work, equilibrium molecular dynamics (MD) simulations in a microcanonical ensemble are performed to evaluate the friction coefficient of a Brownian particle (BP) in a Lennard-Jones (LJ) solvent. The friction coefficients are determined from the time dependent friction coefficients and the momentum autocorrelation functions of the BP with its infinite mass at various ratios of LJ size parameters of the BP and solvent, ${\sigma}_B/{\sigma}_s$. The determination of the friction coefficients from the decay rates of the momentum autocorrelation functions and from the slopes of the time dependent friction coefficients is difficult due to the fast decay rates of the correlation functions in the momentum-conserved MD simulation and due to the scaling of the slope as 1/N (N: the number of the solvent particle), respectively. On the other hand, the friction coefficient can be determined correctly from the time dependent friction coefficient by measuring the extrapolation of its long time decay to t=0 and also from the decay rate of the momentum autocorrelation function, which is obtained by time integration of the time dependent friction coefficient. It is found that while the friction coefficient increases quadratically with the ratio of ${\sigma}_B/{\sigma}_s$ for all ${\sigma}_B$, for a given ${\sigma}_s$ the friction coefficient increases linearly with ${\sigma}_B$.

전력용 HEMT를 이용한 1740~1780MHz 대역의 MMIC 전력증폭기 설계 (Design of MMIC Power Amplifier using Power HEMT at 1740~1780MHz)

  • 윤관기;조희철이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.675-678
    • /
    • 1998
  • In this paper, power amplifiers for PCS phone were designed with the GEC Marconi H40 HEMT libray. The 1st stage was carefully designed in order to obtain k〉1 using a parallel resistor, and its S21 gain of 18.3dB and input reflection coefficient of -4dB were obtained. And S21 gain of 18dB and input reflection coefficient of -7dB were obtained from the 2nd stage. Finally, total S21 gain of 38dB, input reflection coefficient of -16dB, power gain of 35.2dB, output power of 28.7dBm and PAE(power added efficiency) of 29% were obtained from the designed MMIC power amplifiers. The chip size is $1.729$\times$0.94\textrm{mm}^2.$

  • PDF

무향수조를 위한 흡음재질에 관한 연구 (A study on the new absorption material for anechoic water tank)

  • 김성부;이종규
    • 수산해양기술연구
    • /
    • 제48권2호
    • /
    • pp.174-179
    • /
    • 2012
  • A new absorption material, cellulose sponge soaked in cement, was made for anechoic water tank and its acoustical properties were investigated by pulse methods. The sound absorption coefficient a (dB/cm) of the material was obtained in the frequency range of 40~120kHz from the echo reduction ER (dB) and insertion loss IL (dB) data. The result was averagely 1.8dB/cm higher than the sound absorption coefficient a (dB/cm) of cork-filled rubber which is one of the most effective absorption materials. The wedge (1.2~5.0cm long) type absorption tiles were made with this new material. The echo reduction ER (dB) of the absorption tile with 5.0cm wedge measured in water tank was higher than 20dB in the experimental frequency range.

철근콘크리트의 부식에 영향을 미치는 물질 투과성능에 관한 실험적 연구 (An experimental study on Influence of Permeability on corrosion of reinforced Concrete)

  • 김용로;김영덕;조봉석;장종호;권영진;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.62-65
    • /
    • 2003
  • In this study, to confirm corrosion of reinforced concrete affected by carbonation, chloride ion diffusion, absorption ratio, air permeability, measured carbonation velocity coefficient, chloride ion diffusion coefficient, absorption coefficient, air permeability coefficient. Corrosion velocity under environment of complex deterioration. And than compared corrosion velocity with these coefficients. As the results of this study, the correlation coefficient between chloride ion diffusion coefficients and absorption coefficient was revealed that it is very high. As well, an increase in carbonation, chloride ion diffusion also increases corrosion velocity. It showed that corrosion velocity was affected by the carbonation, chloride ion diffusion, absorption ratio, air permeability. Generally, data on the development of these coefficient made with none, organic B, organic A, inorganic B, and inorganic A is shown. It showed that coating of surface prevent steel bar from deteriorating.

  • PDF

현장측정을 통한 터널 내 벽면마찰계수 추정 연구 (The estimation of the wall friction coefficient in tunnels by in-situ measurement)

  • 김효규;최판규;이호형;백두산;나광훈
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.405-421
    • /
    • 2018
  • 현재 국내터널에 적용중인 벽면마찰계수는 단순히 외국의 연구결과를 인용하여 사용하고 있는 실정이다. 또한 기존 선행연구들에서는 속도감쇄법을 이용하여 벽면마찰계수를 추정하였으나, 터널 내 수렴풍속이 음수(-)이거나 자연풍의 변화가 있는 경우에는 벽면마찰계수에 대한 추정이 어려운 점이 있었다. 이에 따라 본 연구에서는 기존 속도감쇄법과 더불어 동적 시뮬레이션기법을 적용하여 벽면마찰계수를 추정하였다. 분석결과, 총 9개 터널(양방향 18개 튜브)에 대한 터널 내 마찰계수는 0.011~0.025 정도로 분석되었으며, 평균값은 0.020로 추정되었다. 또한, 본 연구를 통해 정량적으로 획득한 벽면마찰계수를 현재 적용중인 설계기준과 비교하였다.

Numerical investigation of wind interference effect on twin C-shaped tall buildings

  • Himanshoo Verma;R. S. Sonparote
    • Wind and Structures
    • /
    • 제37권6호
    • /
    • pp.425-444
    • /
    • 2023
  • This study is to investigate the effect of interference between two C-shaped high-rise buildings by computational fluid dynamics (CFD), focusing on the variation of the local pressure coefficient (CP) and the mean pressure coefficient (CPMEAN). Sixteen building position cases are considered for the present study. These cases were based on the position and height of the interference building (IB). The pressure coefficient (CP) is calculated on the principal building (PB) and is compared with an isolated building identical in shape and size. The interference effect on PB has also been presented in reference for the interference factor (IF). According to the findings, the maximum force coefficient on the PB is 0.971 and it is 10.97% more than the isolated PB when IB is located at position 2b (two times the width of the building), and the interfering height of 13H/15 mm. The moment coefficient on PB is 1.27, which is 27.36% less than the isolated case in which IB pushed 2b to 3b in the y direction with 750 mm height. In most of the cases, because of the shielding effect of the IB, the value of force coefficient (CF) on PB has been reduced. On the face of the PB, there are also considerable differences in the mean pressure coefficient CPMEAN. When IB was positioned at a location of 2b in Y direction and an interfering height of 13H/15 mm, the maximum CPMEAN (1.58) was observed on the leeward face of PB.