• 제목/요약/키워드: Average of normal

검색결과 2,624건 처리시간 0.028초

활성산소(活性酸素)에 의한 산화스트레스환자의 사상체질별(四象體質別) 특성(特性)에 관한 연구(硏究) (The Research on the Oxidative Stress by Free Oxygen Radicals in Sasang Constitution)

  • 한경수;안택원;배나영
    • 사상체질의학회지
    • /
    • 제18권3호
    • /
    • pp.155-165
    • /
    • 2006
  • 1. Objectives The purpose of this research is to find out the Constitutional difference of Oxidative stress by Free oxygen radicals. 2. Methods We enrolled 55 patients who visited our hospital for medical examination from February 1, 2006 to May 31, 2006. This research investigated the Constitutional difference of Oxidative stress by Free oxygen radicals. 3. Results and Conclusions l) The Sasang Constitutional distribution of patients have oxidatative stress by Free oxygen radicals was Taeunmin 30%(8persons of total 27persons), Soeumin 56%(9persons of total 16persons), Soyangin 33%(4persons of total 12persons). The rate of patients have oxidatate stress was high in Soeumin. The Sasang Constitution had significance relation with oxidatative stress by Free oxygen radicals. 2) Triglyceride on the average of Taeumin patients have oxidatative stress by Free oxygen radicals is ststistical significantly higher than Triglyceride on the average of controlled normal persons in Taeumin(p-value=0.010) and Soyangin(p-value=0.015). Blood uric acid level on the average of patients have oxidatate stress by Free oxygen radicals is ststistical significantly lower than Blood uric acid level on the average of controlled normal persons in Taeumin(p-value=0.004) and Soyangin(p-value=0.037). This research has shown that there is a statistical significance between the Triglyceride level, Blood uric acid level and oxidatate stress by Free oxygen radicals.

  • PDF

A comparative study on the location of the mandibular foramen in CBCT of normal occlusion and skeletal class II and III malocclusion

  • Park, Hae-Seo;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.25.1-25.9
    • /
    • 2015
  • Background: During the orthognathic surgery, it is important to know the exact anatomical location of the mandibular foramen to achieve successful anesthesia of inferior alveolar nerve and to prevent damage to the nerves and vessels supplying the mandible. Methods: Cone-beam computed tomography (CBCT) was used to determine the location of the mandibular foramen in 100 patients: 30 patients with normal occlusion (13 men, 17 women), 40 patients with skeletal class II malocclusion (15 men, 25 women), 30 patients with skeletal class III malocclusion (17 men, 13 women). Results: The distance from the anterior border of the mandibular ramus to mandibular foramen did not differ significantly among the three groups, but in the group with skeletal class III malocclusion, this distance was an average of $1.43{\pm}1.95mm$ longer in the men than in the women (p < 0.05). In the skeletal class III malocclusion group, the mandibular foramen was higher than in the other two groups and was an average of $1.85{\pm}3.23mm$ higher in the men than in the women for all three groups combined (p < 0.05). The diameter of the ramus did not differ significantly among the three groups but was an average of $1.03{\pm}2.58mm$ wider in the men than in the women for all three groups combined (p < 0.05). In the skeletal class III malocclusion group, the ramus was longer than in the other groups and was an average of $7.9{\pm}3.66mm$ longer in the men than women. Conclusions: The location of the mandibular foramen was higher in the skeletal class III malocclusion group than in the other two groups, possibly because the ramus itself was longer in this group. This information should improve the success rate for inferior alveolar nerve anesthesia and decrease the complications that attend orthognathic surgery.

Assessment of the pigeon (Columba livia) retina with spectral domain optical coherence tomography

  • Kim, Sunhyo;Kang, Seonmi;Susanti, Lina;Seo, Kangmoon
    • Journal of Veterinary Science
    • /
    • 제22권5호
    • /
    • pp.65.1-65.12
    • /
    • 2021
  • Background: To assess the normal retina of the pigeon eye using spectral domain optical coherence tomography (SD-OCT) and establish a normative reference. Methods: Twelve eyes of six ophthalmologically normal pigeons (Columba livia) were included. SD-OCT images were taken with dilated pupils under sedation. Four meridians, including the fovea, optic disc, red field, and yellow field, were obtained in each eye. The layers, including full thickness (FT), ganglion cell complex (GCC), thickness from the retinal pigmented epithelium to the outer nuclear layer (RPE-ONL), and from the retinal pigmented epithelium to the inner nuclear layer (RPE-INL), were manually measured. Results: The average FT values were significantly different among the four meridians (p < 0.05), with the optic disc meridian being the thickest (294.0 ± 13.9 ㎛). The average GCC was thickest in the optic disc (105.3 ± 27.1 ㎛) and thinnest in the fovea meridian (42.8 ± 15.3 ㎛). The average RPE-INL of the fovea meridian (165.5 ± 18.3 ㎛) was significantly thicker than that of the other meridians (p < 0.05). The average RPE-ONL of the fovea, optic disc, yellow field, and red field were 91.2 ± 5.2 ㎛, 87.7 ± 5.3 ㎛, 87.6 ± 6.5 ㎛, and 91.4 ± 3.9 ㎛, respectively. RPE-INL and RPE-ONL thickness of the red field meridian did not change significantly with measurement location (p > 0.05). Conclusions: Measured data could be used as normative references for diagnosing pigeon retinopathies and further research on avian fundus structure.

Implementation of the F-B function comparison on the body movement

  • Kim, Jeong-Lae;Hwang, Kyu-Sung;Nam, Yong-Seok
    • International journal of advanced smart convergence
    • /
    • 제3권1호
    • /
    • pp.20-24
    • /
    • 2014
  • To compare body signal, was designed the F-B function system on the body movement for the comfortable state. To detect subject of the normal state, was decided on the base of physical signal in the body movement. There are to detect the condition of Vision, Vestibular, Somatosensory and CNS. Vision condition was verified a variation of greater average (Vi-${\Phi}_{AVG-AVG}$) was presented slightly greater at $17.424{\pm}9.65$ unit. Vestibular condition was identified a variation of slightly greater average (Ve-${\Phi}_{AVG-AVG}$) was presented at $9.068{\pm}1.478$ unit. Somatosensory condition was checked a variation of smaller average (So-${\Phi}_{AVG-AVG}$) was presented slightly smaller at $2.79{\pm}0.419$ unit. CNS condition was confirmed a variation of diminutive smaller average (C-${\Phi}_{AVG-AVG}$) was presented slightly larger at $0.557{\pm}0.153$ unit. As the model depends on the F-B function system of body movement, average values of these perturbation were computed F-B function comparison data. These systems will be to infer a data algorithm and a data signal processing system for the evaluation of the stability.

여성이 경험하는 월경전 불편감 (Pre-Menstruation Discomforts Experienced by Women)

  • 김은하;김신정
    • 여성건강간호학회지
    • /
    • 제7권4호
    • /
    • pp.631-641
    • /
    • 2001
  • This study is to investigate women have pre menstruation discomfort, The period of this research was almost one month (from 25, August 2001 to 25, October 2001). The PAF (Premenstrual assessment form), which was made by Park, Myonng-Wha, used for this study. The confidence rate is Crombach's $\alpha$= .9773. Correcting research papers are analyzed by SPSS 7.5 program and normal feature of the subject is divided by frequency, percentage, mean, standard deviation, t-test and ANOVA. The results of this study are as follows; 1. The average age of the subjects is 26.47 age. 220 subjects(44.6%) have gastroenteric trouble like, enteritis, stomachache, laxity. 278 subjects usually have caffeine drink in routine life. 123 subjects(24.9%) have controlled their diet. The average age of the first plowing is 13.55 ages and distribution is between 10 years and 20 years. The average of the uncomfortable point is 2.84. The way to reduce the uncomfortable feeling on the menstruation is taking relax time. 2. All subjects have experienced pre menstruation discomfort, even the degree uncomfortable feeling is different. Through eighteenth categories on the research papers, average point 2.21 were calculated and many subjects have fatigue ($2.89{\pm}1.0614$) and normal physical uncomfortable ($2.84{\pm}1.0633$) and undercurrent water symptom and unsuitability ($2.45{\pm}0.9857$). 3. According to the result of this study, that shows statistical difference; age (F=2.56. p=.037). marriage (t=2.60, p=.009) the number of children(t=2.83, p=.005), stress level(F=13.03, p=.000) job(F=3.91, p=.020). monthly income(t=2.14. p=.032) uncomfortable degree on the menstruation (F=19.121, p=.000), use of contraceptive appliance or pill(t=-2.20, p=.043), schooling (F=3.30, p=.038). Further research is need to understand pie menstruation discomforts, the variables associated with them. And nursing intervention has to considered in program to reduces of pre-menstruation discomforts.

  • PDF

뇨중 연 분석의 정확성 및 정밀성에 미치는 최적 전처리법 (Accuracy and Precision according to Optimal Preparation by Analysis of Urine Lead)

  • 장봉기;정은희;박종안;손부순;이종화
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.91-101
    • /
    • 2001
  • In order to propose a optimum method increasing accuracy and reproducibility in analysis of urine lead levels, we compared matrix modifier addition method and microwave digestion method. The results were as follows ; 1. Where the concentration of $Pd(NO_3)_2$(matrix modifier) was $50mg/{\ell}$, and ashing temperature was $900^{\circ}C$, the results were optimum. In case of matrix modifier addition method, the average coefficient of variation (CV) of normal man was 24.1%, and lead worker was 7.9%. The average urine lead levels of standard were $10.42\mu{g}/{\ell}$ and $19.89\mu{g}/{\ell}$ , the accuracies compared to reference values were 97.0% and 92.6%, respectively. 2. Microwave digestion temperature($160~180^{\circ}C$), time(15~25min) and the ratio of urine/ashing acid(1:1~4:1) did not significantly affect lead absorbance and background absorbance. Therefore we set up a optimum analytical conditions as follows: temperature, $160^{\circ}C$; time, 15min; the ratio of urine/ashing acid, 4:1. after samples were digested by the above analytical conditions, lead absorbance and background absorbance was measured at $450^{\circ}C$ as ashing temperature. The average coefficient of variation (CV) of normal man was 12.4%, and lead worker was 6.2%. The average urine lead levels of standard urine were $10.66\mu{g}/{\ell}$ and $23.31\mu{g}/{\ell}$, the accuracies compared to reference values were 99.3% and 103.9%, respectively. From the results, we suggest that microwave digestion method is a more favorable method than matrix modifier addition method because of easiness to reduce organic matter, possibility to analysis at low temperature and accuracy.

  • PDF

한국재래산양(韓國在來山羊)의 발정주기중(發情週期中) 혈장(血漿) progesterone 농도변화(濃度變化)와 조기임신진단(早期姙娠診斷)에의 응용(應用) (Changes of plasma progesterone concentrations during the estrous cycle and its application to early pregnancy diagnosis in Korean native goats)

  • 최한선;박영준;강병규;박범준;손창호
    • 대한수의학회지
    • /
    • 제32권2호
    • /
    • pp.259-265
    • /
    • 1992
  • A study was conducted to improve the reproductive performance of Korean native goats. The length of estrous cycle and plasma progesterone concentrations during each cycles were determined by both radioimmunoassay and estrus behaviours, and the results were used in the early pregnancy diagnosis. The estrous cycles were classified into the short(l8 days or shorter, average 16.7 days), normal(19 to 22 days, average 20.9 days) and long(23 days and longer, average 23.8 days)cycle. The average length of the 19 estrous cycles was 20.8 days. Plasma progesterone concentrations in 12 normal cycles were the lowest(0.10 ng/ml) at estrus, remained high from 6 to 16 days(range : 4.43~7.93 ng/ml) and drastically decreased thereafter to reach minimal concentrations at the next estrus. Plasma progesterone concentrations were measured for early pregnancy diagnosis at 0, 10 and 20 days after mating in the 12 Korean native goats. Plasma progesterone concentrations in the pregnant goats at 20 days after mating were significantly higher than in the non-pregnant goats(p<0.001). Of the 12 goats, 10 were confirmed pregnancy by both progesterone concentrations and kidding. The accuracy of the pregnancy diagnosis based on plasma progesterone concentrations was 100% for positive as well as for negative.

  • PDF

도시에 거주하는 여자노인의 영양상태와 건강상태에 관한 조사연구 (A Study on the Nutritional Status and Health Condition of Elderly Women Living in Urban Community)

  • 김혜경
    • Journal of Nutrition and Health
    • /
    • 제22권3호
    • /
    • pp.175-184
    • /
    • 1989
  • This survey was carried out to obtain the information concerning nutritional status, including factors of food intake and health condition of elderly women living in Ulsan city. Main results were as follows. 1) Dietary intake data showed the average daily intake of energy, protein, vitamin A, riboflavin and ascorbic acid were lower than Korean recommended dietary allowances (RDA). According to the percentage of RDA, Vitamin A was the nutrient found to be least sufficient. 2) Among the various influencial factors, pocket money, meal-mate, skip meal and health concern influenced on nutrient intake considerably. A meal condition score based on influencial factors, showed significant correlations with all nutrient intake(P<0.001). A health score based n the subjects complains about health condition, showed significant correlations with intake of energy, carbohydrate, thiamin, and niacin(P<0.05). 3) Average hight was below Korea reference, while average body weight of subjects was close to Korean reference. Average body mass index was 23.0. 4) The average systolic and diastolic blood pressure was 140mmHg/88mmHg, the proportion of hypertension was 32.4 percent. The average hemglobin concentration was 12.7g/dl, only 6.7 percent of subjects were anemic. Serum cholesterol concentration was normal range(140~220mg/dl) in all subjects.

  • PDF

EMAT를 이용한 판재의 소성이방성 평가 (Evaluation of Plastic Anisotropy in the Steel Sheets Using EMAT)

  • 안봉영;김영길;이승석
    • 비파괴검사학회지
    • /
    • 제17권4호
    • /
    • pp.270-277
    • /
    • 1997
  • 소성이방성은 판재의 가공성을 결정하는 중요한 인자로써 주로 기계적인 인장시험에 의해 측정되고 평가되어 왔다. 압연 방향에 대하여 상대적인 방향으로 진행하는 초음파의 속도로부터 집합조직의 결정분포함수를 구할 수 있으며, 결정분포함수의 계수인 결정방위계수는 소성이방성의 평균값들과 상관 관계를 갖는다. 본 실험에서는 초음파 속도로 구한 결정방위계수와 압연강판의 소성이방성을 비교하여 서로의 상관 관계를 구하였으며, 측정결과 average normal anisotropy, $\bar{\gamma}$${\pm}0.082$, average planar anisotropy, ${\Delta}r$${\pm}0.096$의 편차 내에서 예측 가능하였다. 초음파 속도 측정에는 공진주파수측정법이 적용되었고, 초음파의 송수신에는 EMAT가 이용되었다.

  • PDF

인위적인 이갈이가 교근의 Silent Period에 미치는 영향에 관한 연구 (THE EFFECT OF EXPERIMENTAL BRUXISM ON THE MASSETERIC SILENT PERIOD)

  • 성무경;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.205-212
    • /
    • 1987
  • The purpose of this study was to investigate the duration of the silent period of the masseter muscle in normal subjects after experimental bruxism. The material for this study consisted of 9 male subjects with an age range of 22-24 years who showed normal occlusion clinically and were free from any history or symptoms of temporomandibular joint dysfunction. A jaw-jerk was stimulated by tapping the mandibular symphysis during maximal voluntary clenching with a solenoid-driven hammer. And three separate silent period records were made from the left masseter muscle at the following times: at normal state, after experimental bruxism, 1 week after bruxism. The following conclusions were obtained: 1. The average value of the duration of masseteric silent period during maximal voluntary clenching was $33.62{\pm}1.86msec$ when tap force of approximate 650g was applied at normal state. 2. After experimental tooth grinding for 30 minutes, the duration of masseteric silent period increased to $46.29{\pm}4.40msec$. 3. Comparing the duration of silent period measured at normal state with that measured after 1 week, the duration of silent period showed reproducibility.

  • PDF