• Title/Summary/Keyword: Average of Floor

Search Result 378, Processing Time 0.027 seconds

Study on the Utilization of Sawdust Bedding Barn for Dairy Cows II. Comparision of utilization efficiency of the different depth of sawdust bedding for dairy cows (착유우의 톱밥발효우사 이용 연구 제2보 :착유우 톱밥발효우사의 톱밥상 처리방법에 따른 이용효과 비교)

  • 권두중;권응기;정석근;한정대;정석찬;강승원;강상열;정형섭;장학주
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.117-124
    • /
    • 1995
  • This study was carried out to investigate the effect of depth of sawdust bedding and ground material in dairy cattle barn. Treatment included the concrete floor with a 10cm or 30cm sawdust and the earth floor with a 30cm sawdust. Eighteen cows were assigned to 3 pens with 16.5㎥/head bedding area. The results obtained were as follows : 1. The temperature of sawdust bed was highest in the earth floor with 30cm sawdust, and the moisture content of sawdust bed was highest in the concrete floor with 10cm sawdust bed. 2. Cows defecate feces 9.2, 8.7 and 9.3 times a day in 10cm sawdust on concrete floor(10S+C), 30cm sawdust on concrete floor(30S+C) and 30cm sawdust on non concrete floor(30S+ NC) respectively. In average, they excreta 9.1 times/day(85.8%) in the sawdust beds and 1.5 times/day(14.2%) in the feeding alley. 3. The ratio of daily water amount deposited vapor to total water amount deposited in sawdust beds was 74.0%, 61.5% and 47.1% in 10S+C, 30S+C and 30S+NC respectively. 4. N.P.K contents in the sawdust beds were higher for 10S+C compared with other treatments. 5. When 30cm of sawdust was applied on the earth ground NO$_3$-N contents in the sawdust bed was 37.7, 14.1 and 15.0ppm in depth of 30, 60 and 90cm under the ground, respectively, indicating some possibility of water pollution.

  • PDF

A Experimental Research on Stair Ascent Evacuation Support for Vulnerable People (안전약자 상층 대피 지원에 관한 실험적 연구)

  • Lee, Ji Hyang;Lee, Hyo Jeong;Kwon, Jin Suk;Park, Sang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.90-97
    • /
    • 2019
  • This study is aiming to compare stair ascent transportation speed and physical burden of evacuation supporters according to the types of stair ascent transportation for vulnerable people experimentally. In this study, we measured heart rate of the supporters to indicate physical burden during the transportation. The subjects of this experiment were male students, age of 20-26. Experimental conditions were the ways of stair transportation and the weight of vulnerable people. The types of stair transportation were giving a piggyback ride and carrying a wheelchair. Each experimental trial was video-recorded for measurement of ascent speed and observing supporters movement. As a result of the experiment, as for the ascent transportation speed by piggyback ride from the first floor to the fourth floor, the average speed of the light case is 31 seconds and for the heavy case is 43 seconds. When it comes to the average speed of wheelchair transportation's average speed the light case is 1 minute and 11 seconds and the heavy case is 1 minute and 49 seconds. Therefore, it was indicated that when the weight of a vulnerable people is lighter, the transportation speed is faster. The heart rates of evacuation supporters are different depending on transportation methods or individual's condition but as repetitive transportation increases, they tend to reach the maximum heart rates.

Litterfall and Nutrient Input via Litterfall in Pinus densiflora Forest at Mt. Worak National Park (월악산 소나무림의 낙엽생산과 낙엽을 통한 영양염류 이입량)

  • NamGung, Jeong;Mun, Hyeong-Tae
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.3
    • /
    • pp.261-265
    • /
    • 2009
  • Litter production, nutrient concentration of each component of litterfall and amount of nutrients input to forest floor via litterfall were investigated for three years from May 2005 through April 2008 in Pinus densiflora forest at Mt. Worak National Park. Amount of litterfall in 2005, 2006, 2007 were 3.070, 3.066, 3.099 ton $ha^{-1}yr^{-1}$, respectively. Average amount of litterfall for three years was $3.078{\pm}0.018\;ton\;ha^{-1}yr^{-1}$. Average percentage of leaf litter, branch and bark, reproductive organ and the miscellaneous for three years were 61.9, 10.4, 5.2, 22.5%, respectively. Average amount of N, P, K, Ca and Mg returned to forest floor via litterfall for three years in this P. densiflora forest were 18.014, 0.878, 4.240, 7.349 and 2.172 kg $ha^{-1}yr^{-1}$, respectively.

A Survey on the Current Illumination Environment of Cosmetic Shops (화장품 매장의 조명환경 실태조사)

  • Kim, Hyun-Ji;An, Ok-Hee;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.1
    • /
    • pp.71-75
    • /
    • 2001
  • This study investigates the relationship between size of cosmetic shops, size of showcases, sorts and arrangement of light source, floor plan, and illuminance measured of interior space. From this result, the average space size of cosmetic shops were $623.2{\times}512.9{\times}258.1cm$(width, length, height), the average space size of showcases were $273.3{\times}53.8{\times}89.5cm$ (width, depth, height). The light source was most frequently used fluorescent lamp, and illuminance was the most highest nearby main showcase, and average illuminance were 722[Ix], uniformity were 0.3.

  • PDF

Evaluation on Flexural Performance for Light-Weight Composite Floor with Sound Reduction System (층간소음 대응형 경량합성바닥판에 대한 휨성능 평가)

  • Bae, Kyu Woong;Lee, Sang Sup;Park, Keum Sung;Heo, Byung Wook;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.241-250
    • /
    • 2014
  • The purpose of this study is to propose structural technologies on the light-weight composite floor systems in the unit modular and to evaluate structural performance of the composite floor through flexural experiments. The flexural experiments were carried out on total nine specimens(each three type in shape) using steel flat deck and truss deck. From the results of test, all specimens showed the same failure patterns which exhibited deflection at the center of the specimens due to flexural deformation before concrete crushing at the upper of specimens. Also, we know that the proposed floors satisfied in serviceability and would be safe sufficiently. The ratio of experimental yield load by theoretical nominal load was the distribution of 0.86 to 1.27 with an average 1.04. Coefficient of variation in distribution showed good agreement.

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

The Effect of Stage diffusers on the Stage Acoustics in a Concert Hall (콘서트홀에서 무대음향에 대한 확산체의 영향)

  • Lee Chung-Hwa;Jeon Jin-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.171-177
    • /
    • 2005
  • The effect of diffusers on Early Stage Support (ST1) in a concert hall was investigated at 8 positions in a 1:25 stage scale model. Experiments were carried out when the stage floor was covered with and without absorption cloth to investigate the effect of stage floor reflection (absorption coefficient - 0.6 at 500Hz). To find out the effect of stage wall. three types of wall diffusers were used. As a result. absorption cloth on stage floor reduced the ST1 values at high frequency. but the average value of ST1 was not changed. Three types of stage wall diffusers were revealed as unaffecting. but it was observed that the ST1 values varied to positions of stage. The ST1 values were evenly distributed when hemisphere diffusers were used. Therefore. the use of floor absorption did not have much effect on the ST1 values, and the diffusers had some effect on the distribution of the ST1 values.

A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System (가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구)

  • Yoon, Seong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.

Analysis of The Low Floored Bus Effect on Elderly People (교통약자를 위한 저상버스도입의 효과에 대한 연구 - 노년층을 중심으로 -)

  • Kim, Ji Young;Rhee, Jong Ho;Oh, Seung Hwoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1D
    • /
    • pp.29-34
    • /
    • 2008
  • The Korean society has been changed to the aging one. The number of elderly people has been in creasing rapidly. For their social and economic activity, more convenient transport services have to be offered. Specifically, increasing mobility is one of the most urgent policies for them. One action of the policy in Seoul has introduced low floor buses since 2003. This paper shows how low floor buses affect on passengers' boarding and alighting time through the field survey. In the analysis of the survey results it has been found that the low floor buses can reduce average boarding time by 0.8 sec, especially, by 1.1 sec (about 36%) for elderly passengers. These outcomes expect total bus operating hours as well as headways could be reduced, and operating cost and passengers' waiting time could be saved.

Comparison of Litter Production and Nutrient returned to Forest Floor according to Forest Fire Type and Recovery (산불유형과 회복정도에 따른 낙엽생산량과 임상으로 이입되는 영양염류 함량)

  • Kim, Jung-Sup;Yang, Keum-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • This study has compared the different types of forest fire sites and the unburned site at Samcheuk-si Gangwon-do by assessing the amount of litter production, nutrient concentration returned to forest floor from July 2007 through October 2010. The research showed that the average amounts of litterfall produced in the unburned site, the crown fire site(C-1), the crown fire site(C-3) and the ground fire site(G-2) were $7.74{\pm}2.56$, $1.17{\pm}0.67$, $2.97{\pm}0.44$ and $2.92{\pm}0.42ton{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. In the unburned site, the average amounts of total nitogen(T-N), total phosphorus(T-P), potassium(K), calcium(Ca) and magnesium(Mg) returned to the forest floor were $22.20{\pm}12.43$, $1.16{\pm}0.46$, $2.68{\pm}1.44$, $16.22{\pm}4.69$ and $1.36{\pm}0.32 kg{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively whereas those in the crown fire site(C-1) were $3.73{\pm}2.31$, $0.10{\pm}0.09$, $0.27{\pm}0.20$, $2.75{\pm}2.58$ and $0.24{\pm}0.27 kg{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. This study showed that the nutrient content returned to forest floor was higher in the following order: unburned site(Un) > crown fire site(C-3) > ground fire site(G-2) > crown fire site(C-1).