• Title/Summary/Keyword: Average of Floor

Search Result 377, Processing Time 0.022 seconds

The Association Between Lameness and Fertility in Dairy Cattle (젖소의 파행증이 번식효율에 미치는 영향)

  • 남치주;연성찬;장광호;김영찬;조명래;서강문;정종태
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.369-374
    • /
    • 1999
  • One hundred forty cows that have claw disorder have been used to study the association between lameness and reproductive disorders. Weak estrus owing to ovarian hypoplasia (41.4%) followed by follicular cyst (39.3%) was more frequent than any other disorders. Two hundred ninety-four cows have been used to study the association between lameness and calving to first service and calving to conception intervals depending on lactations, claw disease and floor conditions. And a comparison of number of services per conception between cows with lameness and cows free from lameness was carried out. The calving to first service intervals were significantly increased from average 78 to 102.5 days and calving to conception intervals were significantly increased from 109.6 to 150.6 days in cows with lameness. The calving to first service and calving to conception intervals were not significant different between lactations in cows with lameness. In comparison of calving to first service and calving to conception intervals in cows with lameness depending on claw disease and floor conditions, there was no significant difference. The average number of services per conception was increased from 1.73 to 2.57 in cows with lameness. Service numbers were more frequent during second lactation (3.0 services) but there was no significant difference between lactations in cows with lameness. Therefore, it is likely that the management of lameness is important factor on proper health control of cows and the cows with lameness show decreased fertility.

  • PDF

A study on the Characteristics of Structural Proportion of Pillar and 'Kong-po' in 'Main Hall of Royal Palace(正殿)' of the Royal Palace (궁궐(宮闕) 정전(正殿)에서 기둥과 공포의 구조적(構造的) 비례특성(比例特性)에 관한 연구(硏究))

  • Park, Eon-Kon;Choi, Hyo-Sik
    • Journal of architectural history
    • /
    • v.14 no.1 s.41
    • /
    • pp.71-87
    • /
    • 2005
  • 4 royal palaces are currently remained from capital city (Seoul) of 'Cho-Sun(朝鮮)' period. In these palaces, 'Main hall of Royal Palace(正殿)' is the center of the Royal Palaces. The 'Main hall of Royal Palace' of the Royal Palace was the best building of that time. Therefore there were many studies about the 'Main hall of Royal Palace'. But these studies were individual studies of these 'Main hall of Royal Palace'. Therefore, this study is to analyze and compare 4 'Main hall of Royal Palace' of the Royal palaces. It is to study the proportion regarding the Diameter of the pillar, the Height, the pillar and pillar Interval's Distance, and the arrangement of 'Kong-Po(bracket sets)'. With these studies, it is to prove that the 'Main hall of Royal Palace' is the building which high construction technique of this time is expressed. Result of this study is as followings; First, the proportion of pillar height(H) to its diameter(D) average from H=8.0 to 8.5D. Only the Myeong-Jeong-Jeon omitted the 'Go-Ju(高柱)' in the 'Toi-Kan (退間)' to place Ea-Jwa(御座). Second, Second, the proportion of diameter of the pillar of 'Eoi-Bu-Pyeong-Ju(外部平柱)' and 'Nae-Jin-Go-Ju(內陣高柱)' average D1(Diameter of 'Eoi-Bu-Pyeong-Ju') =0.91D2 (Diameter of 'Nae-Jin-Go-Ju'). In regards to the height, the single floor 'Main hall of Royal Palace' and double floor 'Main hall of Royal Palace' seems to be different. The height proportion of the double floor 'Main hall of royal palace' is H1(Height of 'Eoi-Bu-Pyeong-Ju')=0.34H2(Height of 'Nae-Jin-Go-Ju') and single floor 'Main hall of Royal Palace' has a proportion of H1=0.62H2. Third, in Geun-Jeong-Jeon, with the proportion of height and diameter of the pillar, interval's distance between pillars and diameter, the pillar interval distance and height, of 'Ea-kan(御間)' from the 'Toi-Kan' is different from 'Main hall of Royal Palace'. This is because the structure of 'Toi-Kan' of Geun-Jeong-Jeon is not stable. In order to reinforce this, 'Gui-Go-Ju(隅高柱)' of the Geun-Jeong-Jeon jut out $4{\sim}7%$ more compared to In-Jeong-Jeon. Fourth, when comparing double floor 'Main hall of royal palace' of Geun-Jeong-Jeon and In-Jeong-Jeon, based on distance of 'Eoi-Bu-Pyeong-Ju' and 'Nae-Jin-Go-Ju' of lower level, the 'Sang-Bu-Pyeong-Ju(上部平柱)' of Geun-Jeong-Jeon jut out $4{\sim}7%$ more compared to the In-Jeong-Jeon and also It becomes thicker. Fifth, the arrangement of 'Kong-Po' on the front row of 'Gan(間)' had to do with the change of side 'Gan'. Even though the Geun-Jeong-Jeon and the In-Jeong-Jeon were double floors, the arrangement of the 'Kong-Po' is different because the number of side bay is different.

  • PDF

Estimating Rainfall Interception Loss of Decomposed Floor in a Deciduous Forest Using Rainfall Simulation Experiments (인공강우실험에 의한 활엽수 부후낙엽층의 강우차단손실량 추정)

  • Ahn, Byungkyu;Choi, Hyungtae;Lee, Qiwen;Im, Sangjun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.3
    • /
    • pp.181-187
    • /
    • 2014
  • Forest floor is one of most distinctive features of forest ecosystem, which provides plants and soil microbes with nutrients, and controls hydrologic condition within the floor by intercepting water during a rainfall event and evaporates back into the atmosphere. In this study rainfall interception loss by decomposed forest floor of a deciduous forest has been experimentally estimated using rainfall simulation experiments. Litter-decomposing fungi were incubated on deciduous forest floor samples for the experiment purposes. On a deciduous floor, a $4.22mm{\cdot}kg^{-1}{\cdot}m^2$ of rain was intercepted immediately before rain ceased. Minimum values of interception loss ranged from 1.62 to $2.41mm{\cdot}kg^{-1}{\cdot}m^2$, with an average of $1.87mm{\cdot}kg^{-1}{\cdot}m^2$. Mann-Whitney test showed that decomposing fungi on the forest floor influenced on rainfall interception capacity.

A Study on the Floor Plan Type and the Spatial Composition of Standard Mental Health Centers in Seoul (서울시 기초정신건강증진센터의 평면유형 및 소요공간구성에 관한 연구)

  • Lim, Yen Jung;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.45-55
    • /
    • 2014
  • Purpose: The purpose of this study is to provide data on the basis for architectural planning of floor plan type and spatial composition by analysing standard mental health centers in Seoul. Methods: Data were collected through literature research, field surveys, and expert interviews to 22 standard mental health centers in Seoul. Results: The results of this study could be summarized as follows; Firstly, Mental Health Center is divided into five types according to the location. Location types of mental health center were 'Director type', 'Health center connection type', 'Public facilities connection type', 'Complex center connection type' and 'Commercial Facilities connection type'. Secondly, Depending on the type of management a mental health center is divided into two types. Types are 'Complex type' and 'Independent type'. Average area of 'Complex type' is $192.99m^2$ and 'Independent type' is $266.87m^2$. This difference affects the various spaces. Implications: It is necessary to give and architectural suggestion of mental health center in response to the proposal of the system.

Development of Relative Calibration Method for Measurement of Radon and Application (라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.243-250
    • /
    • 1997
  • A relative-calibration-method of solid-state-track-detector for measurement of radon in air has been developed, and the concentration of radon in each room of a 15th-floor-apartment was measured by using the relative calibrated SSTD. There is a tendency to decrease the concentration of radon when the floor is higher, but the main factor to reduce the concentration of radon in room appeared to be ventilation rate. Average concentration of radon of the 15th-floor-apartment was $1.50{\pm}0.51pCi/l$, and the highest and the lowest concentration of radon were $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$ respectively.

  • PDF

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

A Study on the Size of the Public Libraries in Korea (우리나라 공공도서관의 규모에 관한 연구)

  • Kim, Young-Seok
    • Journal of Korean Library and Information Science Society
    • /
    • v.44 no.2
    • /
    • pp.377-398
    • /
    • 2013
  • In terms of expanding the infrastructure of public libraries, building many small-size libraries is more efficiency than building a small number of big size libraries. Korean public libraries have been built in big-size in compare to the public libraries in the developed countries. This study aims to analyse why the majority of the Korean public libraries have been built in middle and large size and the floor space of 791 public libraries were examined. It was revealed that the average floor space of 791 public libraries is $2,495m^2$. The study aims to find what policy on library building should be considered to expand effectively the infrastructure of public libraries.

Change master cast by hardening method to position of tray after impression taking (인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화)

  • Lee, Jung Ae
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar (상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구)

  • Yoon Hae-Rym;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF

A Study on the Water Consumption of the Spring Chinese Cabbage in Greenhouse (온실재배 봄배추의 소비수량에 대한 고찰)

  • 윤용철;이종창;서원명;이근후
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.411-417
    • /
    • 1999
  • This study was performed to figure out an optimum water environment and to obtain the fundamental data related with saving labor and water consumption for the chinese cabbage being grown in greenhouse . The productivity of cabbage cultivated in boty pots and floor were compared to each other in the aspects of height and weight depending on the soil saturation levels. Obtained results are as follows. ; In case of pot cultivation , the height as well as weight of cabbage in 80% soil saturation level(P80) were measured to be larger than those in the other 2 soil saturation leves (P100 and P60). The weight of floor cultivated cabbages were relatively larger than that of pot cultivated ones. In accordance with saturation ration, the general trend of water consumption rate was maximum in P80 and was decreased in the order of P80 , P100 and P60. And the average indoor temperature as well as the plant growth rate were found to be closely related with water consumption rate.

  • PDF