• Title/Summary/Keyword: Average of Floor

Search Result 377, Processing Time 0.023 seconds

Depth-dependent Variations in Elemental and Mineral Distribution in the Deep Oceanic Floor Sediments (WP21GPC04) near the Mariana Trench in the Western Pacific Ocean (마리아나 해구에 인접한 서태평양 심해평원의 정점 WP21GPC04에서 수집된 해양 퇴적물의 깊이에 따른 원소 및 광물 분포 변화)

  • Junte Heo;Seohee Yun;Jonguk Kim;Young Tak Ko;Yongjae Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.5
    • /
    • pp.581-588
    • /
    • 2023
  • This study reports depth-dependent elemental distribution and mineral abundance of the oceanic sediment sample (WP21GPC04) near the Mariana Trench collected during the WP21 expedition in 2021. The elemental distribution determined by μ-XRF shows no significant differences with varying depth, with an average SiO2 53.91 wt%, FeO 4.48 wt%, Al2O3 16.56 wt%, MgO 2.56 wt%, CaO 4.79 wt%, Na2O 3.52 wt%, K2O 5.48 wt%, similar to the average chemical composition of global subducting sediments (GLOSS). The mineral abundances analyzed using synchrotron XRD, however, vary with depth. While quartz, mica, and plagioclase were identified at all depths, chlorite was found at shallow depths, and zeolite group minerals, phillipsite and heulandite, showed a gradual change in phase fraction with depth. This suggests a change in sedimentation and alteration environments in the region, or the potential for coexistence emerges due to similar sediment stability. Overall, this study will provide a basis for the future investigations on the evolution of sedimentary environment near the Mariana Trench in the western Pacific Ocean and the phase distribution and the behavior of subducting oceanic sediments, which will affect the lithological and geochemical characteristics of the Mariana susduction system.

Evaluation of Interior Factors in Gyunro-dang and Recommendations for Improvement -In 14 Facilities at Apartment Complex in Seoul- (경로당 실내환경 평가와 개선방안 -서울지역 아파트 단지 내 14개 시설을 중심으로-)

  • 천진희
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.353-362
    • /
    • 2004
  • This research has been done to evaluate the interior environmental factors in Gyungro-dang to suggest the advanced recommendations for them. For this research, the essential interior elements influencing on elderly's behavior were examined with the developed checklist, the lighting and color conditions of main hall at 14 facilities in Seoul area were analysed, and 124 subjects staying at Gyungro-dang were participated in questionaire survey for color preferences. Results showed that 1.The average installation rate of 39 items in checklist was 59%, the mandatory items such as accessible dimension were considered, but several items related to mobility and safety were not properly installed. Therefore not only guiding handrail and floor block to destination but also elimination of obstacles should be reconsidered. 2.The average of illuminances was 289 Lux dose to standard 300 Lux, but lighting quality was too low to support the activities of elderly users. The lighting control devices, combined lighting sources, and suitable lighting techniques should be applied for those facilities. 3.Most facilities were predominantly in warm colors in hue, medium or high value, low saturation, and natural atmosphere with similarity harmony. The color applications in those facilities were not functional, but similar as color preferences for the elderly except overall atmosphere. It is recommendable to include contrast harmony with classic or romantic mood.

  • PDF

Effect of different parities on reproductive performance, birth intervals, and tail behavior in sows

  • Yang, Ka Young;Jeon, Jung Hwan;Kwon, Kyeong Seok;Choi, Hee Chul;Kim, Jong Bok;Lee, Jun Yeob
    • Journal of Animal Science and Technology
    • /
    • v.61 no.3
    • /
    • pp.147-153
    • /
    • 2019
  • A goal for swine farming is the improvement in the number of live-born and weaned piglets per sow. Hence, the effect of parities should consider the correlation between the component traits of reproductive performance, weaning, and duration. Sows were housed in farrowing pens (W 2.2 ${\times}$ D 1.8 ${\times}$ H 1.2 m) on a partially slatted plastic floor. Twenty sows used in this study were between the first and sixth parity in gilts (P1), parity 2-5 (P3), and parity 6-9 (P6). Data collection by parity was classified into three categories: (1) reproduction performance (gestation length, total number of piglets born, number of piglets live born, number of piglets stillborn, total piglet birth weight; (2) weaning traits (weaning period, number of piglets weaning, total piglets weaning weight); (3) duration traits (farrowing duration, placenta expulsion duration, time from last piglet to first placenta, average birth interval, and tail wagging behavior). Gestation length was higher in P6 than P1 and P3 of different parity sows. The maximum value in P1 and P3 was 117 days, but the median value in P6 was 117 days (p < 0.05). The total number of piglets born (p = 0.113), number of piglets live born (p = 0.118), number of still piglets born (p = 0.151), and total piglet birth weight (p = 0.117) were not affected by parity. The number of live piglets was higher than the other parities by an average of $15.6{\pm}2.1$ in P1. The duration of farrowing was the lowest at 22.2 min in P6, but the maximum value was 42.2 min more than other parities (p = 0.355). Weaning traits of sows also did not differ significantly (p > 0.05), but the weaning period from P1 was lower than that of the other parities (p = 0.170). The number of piglets weaned was 10 heads on average in P1, P3, and P6 (p < 0.05). However, the mean values of the total piglet weaning weight (p = 0.377) of P6 (62.0 10.4 kg) were higher than those of P1 (54.9 10.2 kg) and P3 (58.4 13.6 kg). The placenta expulsion duration was higher in P6 than that in P1 and P3 (p = 0.447). The time from the last piglet to first placenta was be lower in P3 than that of the other parities (p = 0.206). The average birth interval was higher in P3 than that of the other parities (p = 0.156). Tail wagging (count) behavior was higher in P6 than in the other parities (p = 0.065). The data showed that the reproduction performance, total piglets born, and weight were higher in the gilts group, and higher in the weaning trait than that in the P6 group. This study examined the relationship between reproductive performance, birth interval and tail motion according to sow parity. Regarding duration, farrowing duration was lower in P6 than that in the other parities, but placenta expulsion and tail wagging were higher in P6 than in the other parities. Therefore, it is possible that the results from these sows could be used as basic data for effective farm management.

Estimation of Influence of Milking System Type on Milking Center Effluent Amount and its Characteristics (착유시스템 유형별 세척수의 발생량과 특성)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Yoo, Y.H.;Jeong, M.S.;Han, C.B.;Choi, H.L.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • The purpose of this study was to determine the effect of milking system type on milking center effluent production through the four seasons. Four different types of milking systems (Bucket, Pipeline, Tandem and Herringbone) were estimated, in duplicate, through the different seasons. The following conclusions can be drawn from this study. 1. The quantity of wastewater produced from Tandem and Herringbone milking systems were significantly larger than Bucket milking system (p<0.05). 2. The main wastewater production was from the washing of milking apparatus. Tandem and Herringbone milking systems produced 398.8 and $407.7{\ell}$/day of wastewater, respectively, for apparatus washing. These values were significantly higher than the other milking systems during the summer (p<0.05). 3. The average wastewater production from the various milking systems was $15.4{\ell}$/head/day. The quantity of wastewater production during summer ($16.4{\ell}$/head/day) season was higher than of the other seasons. 4. The highest level of $BOD_5$ ($906.4mg/\ell$) was produced from the washing of the parlor floor and the lowest level of $BOD_5$ ($212.4mg/\ell$) was produced from the washing of the udders of the cows. 5. The pH of dairy wastewater was in the range of $7.3{\sim}8.2$ and the average levels of $BOD_5$, COD, SS, T-N, and T-P were 731.2, 479.0, 751.6, 79.1, $14.7mg/\ell$, respectively. Following conclusions can be drawn from this experiment. The quantities of wastewater production from Bucket, Pipeline, Tandem and Herringbone milking system were 143.9, 487.9, 914.0, and $856.7{\ell}$, respectively. The average wastewater produced from the milking systems was $15.4{\ell}$/head per day. In order to effectively manage on the wastewater from milking systems, dairy farms need to consider the milking system type and farm size when determining the optimum wastewater treatment system.

  • PDF

Properties of Components for the Dapogye of Hipped and Gable Roof Wooden Buildings (합각지붕 사찰 주불전의 규모에 따른 기둥 및 처마부 관계분석 연구)

  • Go, Jung-Ju;Lee, Jeong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3192-3202
    • /
    • 2014
  • This study has its purposes on analyzing specific features of the elements according to scales of 32 main buddhist sancta among wooden temples with gable roof that are nationally designated as cultural assets, and analyzing influences and proportional relations between main and submaterials, so that it could be basic and objective data for restore and repair cultural assets in the future. Results of the study are following. First of all, the average plane proportion of doritong (facade) and yangtong (side) in 3-room building is about 1.31:1, while it is 1.70:1 in 5-room building. Secondly, as a result of analyzing the locational proportion and thickness of pillars at each location, floor room turned out to have wider space between pillars than that of edge room or side room in both cases of 3 and 5-room buildings. In the mean time, for the average thickness of the pillars in 3-room building, it was 491mm for corner pillars, 433mm for general pillars in cases of 3-room building, while it was 595 and 511mm respectively in cases of 5-room building. The reason why corner pillars are 60~80mm thicker than general ones in average, is determined to considered structural stability and optical illusion. For the third, as a result of analyzing the influences on pillar thickness, eaves projection and eaves height according to the scale(dimension) of buildings, 3-room buildings have outstanding correlation as its scale(dimension) goes bigger, while 5-room ones are not very much influenced by its scale(dimension). For the fourth, as a result of the relation between pillars and eaves, both of 3 and 5-room buildings have longer-projected and higher eaves as their pillars go taller; especially height of eaves turns out to have very close relation between length of pillars. In addition to that, both of 3 and 5-room buildings have much projected eaves as the eaves go higher.

STUDY ON THE KOREAN CRANIOFACIAL SKELETAL PATTERN BY COUNTERPART ANALYSIS (구조적 대응체 분석법(Counterpart Analysis)에 의한 한국인의 악안면 두개 골격형태에 관한 연구)

  • Sohn, Byung-Wha;Lee, Yoon-Jeong;Yang, Choon-Sik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.509-519
    • /
    • 2000
  • Enlow's counterpart analysis explains the complex with anatomic and developmental characteristics where craniofacial aspect of individuals has been developed. The analysis does not compare individual measurement with the normal value from the average of majority but analyzes by comparison of values that each individual has. This study was to clarify the Korean craniofacial skeletal pattern using Enlow's counterpart analysis considering the fact that the craniofacial skeletal pattern has racial and regional variations. This research will be helpful in the future for growth research and research of the orthognathic surgery. For this study, the samples were consisted of 100 Korean adult subjects(50 males and 50 females) who had normal occlusion and pleasing face. Measurement points and lines were established using Enlow's counterpart analysis and they were statistically evaluated. The results indicated that : 1. The average angle between PCF and PMV was $38.54^{\circ}$ in males and $38.43^{\circ}$ in females, and the average Wits' appraisal was -2.51 in males and -2.3 in females. The ramus alignment(R4) was 1.89 in males and 2.36 in females. 2. It shows that females have a longer ramus than the PCF compared to the males, because there was a significant difference in Ramus/PCF horizontal dimensions (Skeletal A3-B3) between female and male subjects 3. It shows that males have a longer mandibular corpus than the maxilla compared to the females, because there was a significant difference in Maxillary/Mandibular arches(Skeletal A4-B4) between male and female subjects 4. In cranial floor+maxilla/ramus+corpus at A and B points(Al-Bl), which represents difference in total horizontal length between the maxilla and mandible, there was no significant difference between males and females. In conclusions, compared to Caucasian, Korean have more depressed midface, prognathic mandible, and ramus that rotates inferioposterior. Also, we observe that Korean women have target ramus posterior cranial base, as compared with Korean men. Consequently, the total length of maxilla and mandible does not show any difference, because man's mandible is longer than maxilla in comparison with woman's one.

  • PDF

SUBANTRAL AUGMENTATION WITH AUTOGENOUS BONE GRAFT FOR SIMULTANEOUS IMPLANT INSTALLATION (상악동저 점막 거상술을 이용한 인공치아 임프란트 동시 식립술 후 예후에 관한 임상적 연구)

  • Kim, Myung-Jin;Kim, Tae-Young;Hwang, Kyung-Gyun;Yu, Sang-Jin;Myoung, Hoon;Kim, Soo-Kyung;Kim, Jong-Won;Kim, Kyoo-Sik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.644-651
    • /
    • 2000
  • In cases of severe alveolar bony resorption in the edentulous posterior maxillae, implant placement is limited anatomically due to maxillary sinus. If the ridge is atrophic, the various bone grafting methods are required for the ridge augmentation. But the result of the onlay grafting procedure is not always promising. On the posterior maxilla, maxillary sinus mucosa lifting and bone grafting into the sinus floor, subantral augmentation(SA) technique are recommended. Various SA procedures have been developed for implant installation. We perfer to simultaneous block bone graft and implant installation through the residual alveolar ridge into the grafted block bone to fix the grafted bone and to gain the primary stability of the installed fixture. When a sagittal skeletal discrepancy in present due to the severe alveolar bony resorption of the maxilla, the advancement of the maxilla by Le Fort I osteotomy simultaneously with installation of implant fixtures combined with sinus lifting and interpositional bone graft procedure can be indicated. We applied various SA techniques for implant installtion to the 46 edentulous posterior maxillae, and total 154 implants were installed at our department from 1992 to 1999. Various SA techniques were classified in detail and the indications of each techniques were discussed. The changes of residual bony height following SA procedure were studied. The results were as follows. 1. The SA procedure combined with bone graft and simultaneous fixture installation were performed in 41 cases, 126 fixtures were installed and 5 fixtures were removed out of them. Le Fort I osteotomy procedure combined with sinus lifting and interpositional bone graft simultaneous with fixture installation were performed in 5 cases. Total 28 fixtures were installed and 2 fixtures were removed so far. 2. Autogenous block bone graft into sinus floor were performed in 35 cases, autogenous particulated marrow cancellous bone(PMCB) graft in 9 cases, and demineralized human bone powder in 2 cases. The donor site for bone graft were anterior iliac bone in 39 cases, posterior iliac bone in 3 cases and mandibular symphysis in 1 case and mandibular ramus in 1 case. 3. In 9 cases with which SA procedure had been performed with the block bone graft, the change of pre- and postoperative residual bony height were measured using MPR(multiplanar reformatted)-CT. The mean residual bony height was 8.0mm preoperatively, 20.2mm at 6 months following up operation and we gained average 12.2mm alveolar bony height. So, we can recommend this one-stage subantral augmentation and fixture installation technique as a time conserving, safe and useful method for compromised posterior edentulous maxilla.

  • PDF

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

Changes in Aboveground Biomass and Nutrient Accumulation of the Korean-pine (Pinus koraiensis) Plantation by Stand Age at kangwondo Province (강원도(江原道) 지방(地方) 잣나무 인공림(人工林)의 임령변화(林齡變化)에 따른 지상부(地上部) 현존량(現存量)과 양분축적(養分蓄積))

  • Yi, Myong-Jong
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.2
    • /
    • pp.276-285
    • /
    • 1998
  • The aboveground biomass and nutrient content (N, P, K, Ca and Mg) of Pinus koraiensis S. et Z., aged 9, 22, 34, 46, 66 years, were measured in the Experiment Forest of Kangwon National University of Kangwondo province. The site index of the stands ranged from 13.5 to 14.2. Allometric equations (logY=alogX+b, where Y, X is ovendry mass and DBH, respectively) relating dry weights of stem, branches and needles to diameter at breast height (DBH) were developed to estimate aboveground tree biomass. Total above ground tree biomass increased with stand age from $21.8t\;ha^{-1}$ in the 9-year-old stand to $130t\;ha^{-1}$ in the 66-Year-old stand. Aboveground biomass was allocated as follows : stem> branch > foliage, except for the 9-year-old stand which had a greater proportion of foliage biomass than branch biomass. As stand age increased, an increasing proportion of annual biomass increment was allocated to stems. The aboveground biomass of shrubs and herbs ranged from 0.4 to $3.9t\;ha^{-1}$ and from 0.05 to $0.6t\;ha^{-1}$, respectively. No relationship was found between aboveground understory biomass and stand age. The mass of woody debris and forest floor varied between 0.59 to $1.54t\;ha^{-1}$ and 6.0 to $21.63t\;ha^{-1}$, respectively. Nutrient accumulation in aboveground tree biomass increased with stand age and was in the order of N > Ca > K > P > Mg. Average rates of nutrients accumulation in biomass were greatest in the early stages of stand development, and less marked as stand aged. The nutrient concentrations in different tree components decreased in the order of needle > branch > stem. There were no detectable trends in nutrient content of the forest floor and mineral soils with stand age. Understory vegetation contributed little to the nutrient pool of these Korean pine ecosystems. Mineral soil contained the Breast proportion of nutrient capital of the various ecosystem compartments.

  • PDF

An Analysis of the Difference in Awareness on Visual Landscape Control Elements among the Expert Groups (경관제어요소에 관한 전문가집단 간 인식차이 분석)

  • Cho, You-Kyung;Kong, Eun-Mi;Kim, Young-Ook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.2
    • /
    • pp.29-39
    • /
    • 2011
  • Recent interests in the quality of urban space have raised awareness on the role and importance of landscape planning. Although laws and guidelines are officially ready to be imposed as for landscape planning, we do not have concrete materials that can be utilized in the course of practices. The aim of this paper in this regard is to disclose the possible difference in awareness on 'visual landscape control elements' among experts engaged with urban space planning. The expert groups are distinguished to three which are for a planning, design and engineering and the survey is made by questionnaires. The results are analyzed through basic technology statistics in SPSS and independent-sample t-test provided. The survey is done by tens of 'control elements' and the result is that specially, group 1 and group 2 in mixed landscape has the most discrepancy in awareness on those elements but relatively, they has less discrepancy in awareness on compare with other groups through all landscape area. In case of artificial landscape and mixed landscape in 'landscape controled area', the result for comparing between G1 and G2 is that there are the most discrepancy in awareness which are 7 control elements. In case of mixed landscape in 'landscape promoted area', there are 4 control elements for discrepancy in awareness between G2 and G3 which is quite different. The control elements which show the most discrepancy in awareness is height, floor space and building to land ratio in order. The shape elements has only discrepancy in awareness for comparing between G1 and G2 of artificial landscape in 'landscape controled area'. In terms of the average evaluation score of the appropriateness of these control elements, G1 seems to appreciate the role of these elements in systematic landscape planning more than the other group does. In other words, relatively low scores are given by G2 as for the overall functionality of visual landscape control elements. The texture, floor space and building of land ratio has low evaluation score for all area and types. It means that it should reverify for appropriateness of performance for landscape planning as visual landscape control elements.