• Title/Summary/Keyword: Average of Floor

Search Result 376, Processing Time 0.016 seconds

공동주택 평균층수 적용에 따른 경관영향 분석 및 제도운용 개선방안 연구 (A Study on the Improvement of Average Floor Height Ordinance through Analyzing Landscape Impacts of Average Floor Height System Applied to Apartment Buildings in Residential Areas of Seoul)

  • 목정훈;김성훈
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.62-70
    • /
    • 2007
  • The purpose of this research is to suggest an improved method of how to apply and operate an average floor height system to rebuilt or redeveloped apartment buildings in general residential areas of Seoul. This research suggested two research findings by a computer simulation study for analyzing the difference between the average floor height of apartment buildings in experimental sites and the average of floors of buildings near experimental sites. The first finding is that an average floor height system should be applied to apartment buildings with a limitation of maximum height at sites larger than $12,000m^2$ in order to control the difference of the maximum height of buildings between apartment sites and their surroundings. The second finding is that the average floor height system should be operated by an appropriate average floor height ratio at sites greater than $50,000m^2$ in order to harmonize rebuilt or redeveloped apartment buildings with their surroundings.

바닥난방 복사열에 의한 온열감 차이에 대한 실험연구 (An Experimental Study on Difference of Thermal Sensation by Radiant Floor Heating)

  • 최윤정;심현숙;정연홍
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.65-71
    • /
    • 2007
  • The purpose of this study was to analyze the difference of thermal sensation by radiant floor heating as ecological design element. The experimental investigations were carried out in climate chamber, and subjects were 34 college-age females in good health. The experimental variable was radiant heat by floor heating, and experimental controlled conditions were indoor temperature, relative humidity, and air velocity in climate chamber and clothing value and activity of subjects. The results are as follows. (1) Indoor temperature($21{\pm}0.5^{\circ}C$) in climate chamber were maintained as controlling. Clothing values of the subjects were controlled as average 0.73 clo. In the floor heating-off, globe temperature was average $23.2^{\circ}C$(22.4~24.1), but in the floor heating-on, globe temperature was average $24.8^{\circ}C$(23.0~25.5). (2) In the floor heating-off, thermal sensation rating was average -1.03(slightly cool), in the floor heating-on, thermal sensation rating was average +1.03(slightly warm). (3) There were the differences of thermal sensation by radiant floor heating although indoor temperatures were maintained in an equal state. (4) The thermal sensation rating was tending upward according as the globe temperature was getting higher.

중정이 계획된 병동부 바닥면적과 간호동선 평균거리 비교 연구 (A Comparative Study of Floor Area and Average Distance of Nurse Working of Planned Courtyard in Ward)

  • 김제원;양내원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권2호
    • /
    • pp.7-16
    • /
    • 2019
  • Purpose: The courtyard in the ward can light and ventilate in the central space and corridor of the ward. It is possible to improve the disadvantages of the existing double-corridor ward. Also, there is the advantage in that patients are able to contact with nature indoors and cause positive activities. So, the purpose of this study is quantitatively analyze the floor area and the average distance of nurse working of the courtyard in ward. Methods: The subjects are converted through the same criteria setting. And it investigate and analyze the influence of the courtyard in the ward through the analysis of the spatial composition. Result: The factors that affected the floor area increase are the planning courtyard, the corridor type and the dispersion of the medical rooms. The average distance of nurse working is more influenced by the nursing management system of the hospital than by the courtyard. So, It can improve according to the position and number of nurse station. Implications: It can be used as a primary data for courtyard plan in the ward for positive patient environment plan considering the floor area, average distance of nurse working.

바닥충격음 차단성능 평가방법의 상호비교 (Comparison of Rating Methods for the Floor Impact Sound Insulation Performance)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF

국내(國內) 인텔리전트 사무소(事務所) 건물(建物)의 건축계획(建築計劃) 관련지표(關聯指標) 추이(推移) 분석(分析) (An Analysis of the Transition of Architectural Data on the Intelligent Office Building in Korea)

  • 변계성
    • 한국디지털건축인테리어학회논문집
    • /
    • 제2권1호
    • /
    • pp.24-31
    • /
    • 2002
  • The purpose of this study was to analyze the transition on architectural data such as valid indoor length, module, ratio of core, floor height, ceiling height and the type of structured cabling system according to the intelligent building grade through case study of the intelligent office buildings constructed in Korea since 1980. The results of this study were as follows. The average floor height was 3.80m, and it was higher in proportion to the IB grade. The average ceiling height was 2.57m, and it didn't have connection with the IB grade. The module of high frequency in application was $3.0{\times}3.0m$, and it showed 25% in the application frequency. The average valid indoor length was 12.27m. The average ratio of core was 24.49%. The type of high frequency in application for the structured cabling was Access Floor Type, and it showed 31% in the application frequency.

  • PDF

비정질 강섬유 혼입 바닥난방시스템의 열성능 평가 (Thermal performance prediction of amorphous steel fibers mixed into the floor heating system)

  • 조현;방승기
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.130-135
    • /
    • 2016
  • 본 연구에서는 비정질 강섬유 혼입 바닥몰탈을 이용한 바닥난방시스템과 일반 몰탈을 사용한 바닥난방시스템의 열성능을 비교 평가하기 위하여 시뮬레이션을 실시하였다. 시뮬레이션은 온수공급온도를 변화시켰으며 다음과 같은 결론을 얻었다. 바닥의 표면온도, 실내의 공기온도 등을 검토 결과 강섬유온돌을 사용할 경우에는 실내공기를 기준으로 하면 강섬유온돌이 일반온돌에 비해 7~9%에 가까운 열효율이 상승되었으며, 바닥의 온도를 기준으로 하면 2~4% 온도상승이 일어나는 것으로 나타났다.

현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험 (Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method)

  • 신훈;백건종;송민정;장길수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.581-586
    • /
    • 2008
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of 31.5Hz - 500Hz is more correspondent to psycho-acoustic response than that of measurement frequency of 63Hz - 500Hz which is for KS F 2863-2, existing rating method.

  • PDF

현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험 (Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method)

  • 신훈;김선우;장길수
    • 한국소음진동공학회논문집
    • /
    • 제19권3호
    • /
    • pp.282-287
    • /
    • 2009
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of $31.5\;Hz{\sim}500\;Hz$ is more correspondent to psycho-acoustic response than that of measurement frequency of $63\;Hz{\sim}500\;Hz$ which is for KS F 2863-2, existing rating method.

아파트단지의 특성에 따른 열병합발전도입의 경제성 비교연구 (Economic Feasibility Study for Providing Co-generation System in various Type of Apartment Complexes)

  • 기우봉;김광호
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.27-37
    • /
    • 2007
  • This study is to analyse the feasibility for providing Co-generation plant in Apartment Complex for 4 typical Apartment Complexes located Seoul metropolitan area, The selected complexes are three midium-large size Apartment[nearby 35pyoug of floor area] and one complex of small size Apartment[below 25 pyoung of floor area] for comparison. The necessary data for the study were collected with visitation of each site. The study showed very positive result for the three medium-large size Apartment Complexes of which the average floor area is more than 25 pyoungs, while negative result for the Complex of which average floor area is less than 25 pyoungs. Other than floor size it was found that the electric consumption density also influence the economic feasibility. In study the unit fixed cost of the energy produced from Co-generation plant is one third of the unit variable cost[fuel cost] and it seems better to select high thermal efficiency machine for Co-generation plant even with some higher cost of the plant.

  • PDF

실내 자율주행 로봇을 위한 3차원 다층 정밀 지도 구축 및 위치 추정 알고리즘 (3D Multi-floor Precision Mapping and Localization for Indoor Autonomous Robots)

  • 강규리;이대규;심현철
    • 로봇학회논문지
    • /
    • 제17권1호
    • /
    • pp.25-31
    • /
    • 2022
  • Moving among multiple floors is one of the most challenging tasks for indoor autonomous robots. Most of the previous researches for indoor mapping and localization have focused on singular floor environment. In this paper, we present an algorithm that creates a multi-floor map using 3D point cloud. We implement localization within the multi-floor map using a LiDAR and an IMU. Our algorithm builds a multi-floor map by constructing a single-floor map using a LOAM-based algorithm, and stacking them through global registration that aligns the common sections in the map of each floor. The localization in the multi-floor map was performed by adding the height information to the NDT (Normal Distribution Transform)-based registration method. The mean error of the multi-floor map showed 0.29 m and 0.43 m errors in the x, and y-axis, respectively. In addition, the mean error of yaw was 1.00°, and the error rate of height was 0.063. The real-world test for localization was performed on the third floor. It showed the mean square error of 0.116 m, and the average differential time of 0.01 sec. This study will be able to help indoor autonomous robots to operate on multiple floors.