Cancer Risk Assessment Due to Natural and Fallout Activity in Some Cities of Pakistan

  • Ahad A.;Matiullah Matiullah;Bhatti Ijaz A.;Orfi S.D.
    • Journal of Radiation Protection and Research
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2006
  • The measured mean activities of $^{226}Ra,\;^{232}Th,\;^{40}K\;and\;^{137}Cs$ in the soil of Bahawalpur, Bahawalnagar and Rahimyar Khan Bistricts were 32.9, 53.6, 647.4 and 1.8 Bq $kg^{-1}$. The average absorbed dose rate calculated from these activities was 74.3 nGy $h^{-1}$ and the mean annual effective dose rate was found to be 0.46 mSv $y^{-1}$. Absorbed doses to different body organs were derived from annual effective doses using tissue weighting factors. Radiation induced fatal cancer risks were assessed by using ICRP 60 Model. Estimations incurred 184deaths per year due to cancer.

촬영조건에 의한 환자 피폭선량의 자동계산 프로그램 (The patient dose calculation model on the Exell program)

  • 김정민;석진용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권2호
    • /
    • pp.35-38
    • /
    • 2002
  • 의료피폭에 관한 관심과 함께 촬영록(촬영조건)을 기록하는 일은 단순히 환자기록이 아니라 피폭선량을 예측하는 방법으로 이용될 수 있다. 그러나 각 장비마다 출력의 차이가 있어서 장치의 출력을 실험을 통하여 구하고 그 출력을 엑셀 프로그램상에서 3차 수식화하여 그 계수를 구함으로서 촬영조건을 입력함과 동시에 피부 입사선량을 구할 수 있는 방법을 고안하였다.

  • PDF

우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량 (Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea)

  • 이광용;이병영;이정은;이현구;정승환;김병우;김혁주;김동섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.401-410
    • /
    • 2009
  • 목 적 : 골반 및 요추 엑스선검사는 진단 엑스선검사 중 생식선을 포함하고 있고 환자가 받는 방사선량이 많은 검사로서 우리나라에는 골반 및 요추 엑스선검사에서의 환자선량 권고량이 마련되어 있지 않다. 따라서 국내 의료기관에서의 골반 및 요추 엑스선검사 시 환자가 받는 방사선량을 측정 평가하고 골반 및 요추 엑스선검사에서 환자의 방사선 방어 최적화를 위한 환자선량 권고량을 확립한다. 방 법 : 전국 125개 의료기관에서 골반 전후면 촬영, 요추 전후면 및 측면 촬영시 촬영조건과 진단영상정보를 조사 분석하고 환자가 받는 입사표면선량을 유리선량계를 사용하여 측정 평가한다. 환자가 받는 방사선량 중 제3사분위값에 해당하는 선량값을 의료기관에 권고할 골반 및 요추 엑스선검사에서의 환자선량 권고량으로 확립한다. 결 과 : 전국 125개 의료기관에서 골반 및 요추 엑스선검사 시 진단영상정보를 조사하고 환자가 받는 입사 표면선량을 측정한 결과 골반 전후면 엑스선검사에서는 관전압이 60~97 kVp, 평균 75 kVp를 사용하였고, 관전류-시간곱(mAs)는 8~123 mAs, 평균 29.7 mAs를 사용하였다. 요추 전후면 및 측면 엑스선검사에서는 관전압을 각각 65~100 kVp, 평균 78 kVp와 70~109 kVp, 평균 87 kVp를 사용하였고, mAs도 각각 10~100 mAs, 평균 35.2 mAs와 8.9~300 mAs, 평균 64.1 mAs를 사용하였다. 골반 및 요추 엑스선검사에서의 환자가 받는 입사표면선량을 측정한 결과, 골반 전후면 엑스선검사에서는 최소값 0.59 mGy, 최대값 12.69 mGy, 평균값 2.88mGy이었으며, 제1사분위값은 1.91 mGy, 중앙값은 2.67 mGy, 제3사분위값은 3.42 mGy이었다. 요추 전후면 엑스선검사에서는 최소값 0.64 mGy, 최대값 23.84 mGy, 평균값 3.68 mGy이었으며, 제1사분위값은 2.41 mGy, 중앙값은 3.40 mGy, 제3사분위값은 4.08 mGy이었다. 요추 측면 엑스선검사에서는 최소값 1.90 mGy, 최대값 45.42 mGy, 평균값 10.08 mGy이었으며, 제1사분위값은 6.03 mGy, 중앙값은 9.09 mGy, 제3사분위값은 12.65 mGy이었다. 결 론 : 우리나라의 의료기관에서 골반 전후면 엑스선검사에서 의료기관에 권고할 환자선량 권고량은 3.42 mGy, 요추 전후면 엑스선검사에서는 4.08 mGy, 요추 측면촬영에서는 12.65 mGy로 세계보건기구 등 6개 국제기구가 공동으로 권고한 골반 전후면 검사 10 mGy, 요추 전후면 검사 10 mGy 및 요추 측면 검사 30 mGy 보다는 낮았다.

  • PDF

이동형 치과 X선 발생장치의 공간선량 분포 (Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment)

  • 한경순;안성민
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.254-258
    • /
    • 2015
  • 치과병의원에서 사용하고 있는 이동형 치과 X선 발생장치를 이용하여 두경부 마네킹에 X선을 조사할 때 주변의 공간선량을 측정하고, 동일한 방법으로 고정형 X선 발생장치에 적용하여 측정된 공간선량을 상호 비교하며, 더불어 기기 및 위치별 공간선량을 비교 분석한 결과는 다음과 같다. 이동형 X선 발생장치의 평균 공간선량은 $37.51{\mu}Sv$로 고정형 X선 발생장치의 $10.77{\mu}Sv$보다 매우 높았다(p<0.001). 이동형 X선 발생장치의 기기별 공간선량은 $17.77{\mu}Sv$부터 $68.90{\mu}Sv$까지 큰 차이를 나타냈다(p<0.05). 위치별로는 직전 위치가 $54.14{\mu}Sv$로 가장 높았고, 직우 위치가 $13.60{\mu}Sv$로 가장 낮았으며, 직좌와 직후 위치는 $42.12{\mu}Sv$, $40.18{\mu}Sv$로 유사하였다(p<0.01). 이상의 결과를 통해 이동용 치과 X선 발생장치는 이동 불가능한 환자만을 대상으로 제한적으로 시행하여야 하며, 반드시 환자와 술자 모두 납 방어복을 착용하여 방사선 피폭을 최소화해야 할 것이다.

2002년 국내 방사선 작업종사자의 직업군별 피폭선량 (Occupational Radiation Exposure in Korea: 2002)

  • 정제호;권정완;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제30권4호
    • /
    • pp.175-183
    • /
    • 2005
  • 2002년 기준으로 국내 52733명의 방사선 작업종사자에 대해 5개 대분류와 28개의 세분류 카테고리로 나눈 직업군별 연간 피폭선량의 분포를 분석하였다. 진단용 X선 분야(치과용 포함) 종사자의 선량 통계는 식품의약품안전청이 제공하였으며 기타 종사자의 선량자료는 한국방사성동위원소협회가 제공하였다. 직업군에 따른 선량준위별, 연령별 성별 종사자수와 연간 평균선량을 분석한 결과 거의 80% 정도의 종사자들이 연간 1.2mSv 이하로 피폭하는 것으로 나타났다. 방사선작업 종사자의 총 집단선량은 66.4man-Sv로 나타났고 평균 선량은 1.26mSv였다. 직업군별로는 체내 핵의학 분야와 비 파괴검사 분야 종사자가 다른 분야에 비해 평균선량이 현저히 높게 나타났다. 진단용 X선 분야 종사자에게서 연간 20mSv 이상 피폭자 수가 상당하여 이에 대한 추가 분석이 필요한 것으로 나타났다. 16기의 원자력발전소 작업종사자 중에는 20mSv를 초과하는 종사자가 한명도 없는 것으로 나타났다. 연령별로 30대 종사자 수가 가장 많았고 20대 종사자의 선량이 상대적으로 높았다. 여성이 전체 작업종사자의 20%정도를 차지하고 있었으며 평균 피폭선량은 남성의 반 정도인 것으로 나타났다.

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안 (Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement)

  • 문재승;신민용;안성철;유문곤;김수근
    • 한국의료질향상학회지
    • /
    • 제20권1호
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

영·유아의 입사피부선량 측정을 위한 몬테카를로 시뮬레이션 (Monte Carlo Simulation for the Measurement of Entrance Skin Dose on Newborn and Infants)

  • 김상태
    • 한국콘텐츠학회논문지
    • /
    • 제12권6호
    • /
    • pp.346-352
    • /
    • 2012
  • 성인과 달리 영 유아에게 행해지는 방사선 검사 시 투여되는 방사선량의 평가는 활발하게 이루어지지 않고 있다. 따라서 영 유아의 방사선 검사 시 피폭되는 정도를 나타내는 지표로서 입사피부선량을 측정하고 Geant4를 이용한 몬테카를로 시뮬레이션을 통한 결과값을 비교하여 입사피부선량 측정의 재현성을 높이고 다양한 지오메트리 구현의 가능성을 증명하였다. 몬테카를로 시뮬레이션 결과값은 입사피부선량을 선량보정을 위한 정규인자를 통해 추정하였고 단위 X선 조사영역크기로 표준화한 결과 영 유아에게 있어 일회의 방사선 촬영 당 평균 입사피부선량은 $78.41{\mu}Gy$ 였으며 선량계를 통한 측정값과 몬테카를로 시뮬레이션값의 백분율 오차는 최대 -4.77%로 나타났다. 몬테카를로 시뮬레이션을 통한 입사피부선량 평가 방법은 의료기관에서 실제 진단을 위해 내원한 환아를 대상으로 한 입사피부선량 평가의 어려움을 대체할만한 수단으로서의 가능성을 보여준다.

Initial Dosimetry of a Prototype Ultra-High Dose Rate Electron-Beam Irradiator for FLASH RT Preclinical Studies

  • Hyun Kim;Heuijin Lim;Sang Koo Kang;Sang Jin Lee;Tae Woo Kang;Seung Wook Kim;Wung-Hoa Park;Manwoo Lee;Kyoung Won Jang;Dong Hyeok Jeong
    • 한국의학물리학회지:의학물리
    • /
    • 제34권3호
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: FLASH radiotherapy (RT) using ultra-high dose rate (>40 Gy/s) radiation is being studied worldwide. However, experimental studies such as preclinical studies using small animals are difficult to perform due to the limited availability of irradiation devices and methods for generating a FLASH beam. In this paper, we report the initial dosimetry results of a prototype electron linear accelerator (LINAC)-based irradiation system to perform ultra-high dose rate (UHDR) preclinical experiments. Methods: The present study used the prototype electron LINAC developed by the Research Center of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Korea. We investigated the beam current dependence of the depth dose to determine the optimal beam current for preclinical experiments. The dose rate in the UHDR region was measured by film dosimetry. Results: Depth dose measurements showed that the optimal beam current for preclinical experiments was approximately 33 mA, corresponding to a mean energy of 4.4 MeV. Additionally, the average dose rates of 80.4 Gy/s and 162.0 Gy/s at a source-to-phantom surface distance of 30 cm were obtained at pulse repetition frequencies of 100 Hz and 200 Hz, respectively. The dose per pulse and instantaneous dose rate were estimated to be approximately 0.80 Gy and 3.8×105 Gy/s, respectively. Conclusions: Film dosimetry verified the appropriate dose rates to perform FLASH RT preclinical studies using the developed electron-beam irradiator. However, further research on the development of innovative beam monitoring systems and stabilization of the accelerator beam is required.

양방사선 골밀도 측정 장치의 공간산란선량분포측정 (Bone Density Spatial Distribution of Radiation Dose Measurement)

  • 김선칠;원도연;박창희;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF