• Title/Summary/Keyword: Average Dose

Search Result 1,095, Processing Time 0.03 seconds

Dose Estimation Model for Terminal Buds in Radioactively Contaminated Fir Trees

  • Kawaguchi, Isao;Kido, Hiroko;Watanabe, Yoshito
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, biological alterations in the natural biota, including morphological changes of fir trees in forests surrounding the power plant, have been reported. Focusing on the terminal buds involved in the morphological formation of fir trees, this study developed a method for estimating the absorbed radiation dose rate using radionuclide distribution measurements from tree organs. Materials and Methods: A phantom composed of three-dimensional (3D) tree organs was constructed for the three upper whorls of the fir tree. A terminal bud was evaluated using Monte Carlo simulations for the absorbed dose rate of radionuclides in the tree organs of the whorls. Evaluation of the absorbed dose targeted 131I, 134Cs, and 137Cs, the main radionuclides subsequent to the FDNPP accident. The dose contribution from each tree organ was calculated separately using dose coefficients (DC), which express the ratio between the average activity concentration of a radionuclide in each tree organ and the dose rate at the terminal bud. Results and Discussion: The dose estimation indicated that the radionuclides in the terminal bud and bud scale contributed to the absorbed dose rate mainly by beta rays, whereas those in 1-year-old trunk/branches and leaves were contributed by gamma rays. However, the dose contribution from radionuclides in the lower trunk/branches and leaves was negligible. Conclusion: The fir tree model provides organ-specific DC values, which are satisfactory for the practical calculation of the absorbed dose rate of radiation from inside the tree. These calculations are based on the measurement of radionuclide concentrations in tree organs on the 1-year-old leader shoots of fir trees. With the addition of direct gamma ray measurements of the absorbed dose rate from the tree environment, the total absorbed dose rate was estimated in the terminal bud of fir trees in contaminated forests.

Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery (척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가)

  • Dong‑Jin Kang;Geon Oh;Young‑Joo Shin;Jin-Kyu Kang;Jae-Yong Jung;Boram Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.527-533
    • /
    • 2023
  • The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.

The Effect of Scattering Dose on the Thyroid During Mammography (Mammography시 Thyroid에 미치는 산란선량에 관한 연구)

  • Lee, Mi-Hwa;Dong, Kyung-Rae;Park, Seo-Joo;Whang, Sun-Kwang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.826-830
    • /
    • 2010
  • This study examined the effect of the scattering dose on the thyroid during a mammography examination. One hundred subjects for a mammography examination were enrolled in this study. The average glandular dose (AGD) and thyroid scattering dose (TSD) were measured. Statistical analysis was carried out using the percentage, t-test and co-variance. The mean radiation exposure to the breast and thyroid was $1.08{\pm}0.16$ and $0.14{\pm}0.04$ mGy, respectively. The percentage TSD to the AGD was 31.19%. There was no difference between the Rt. and Lt., and CC to MLO, and radiation dose to the TSD was 13.78% of the breast. Therefore, the volume of radiation exposure to the thyroid was 54.12% in a single routine mammography examination. These results suggest that the TSD was increased by increasing radiation dose to the breast. A thyroid protector is considered necessary to decrease the level of radiation exposure.

A Study on Regional Irradiation Dose of Radiological Technologists (방사선사의 지역별 피폭선량에 관한 연구)

  • Jung Hong-Ryang;Kim Jeong-Koo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.281-286
    • /
    • 2005
  • This research is to measure the irradiation dose in radiological technologists with 623 radiological technologists working at 44 general hospitals in 16 cities and states nation-wide, during one month from July to August 2003. Questionnaires were used to analyze the dose, while existing data from measurements taken in 5 years was used to analyze amounts of radiation dose level. Average annual irradiation dose level was $1.73{\pm}0.10mSv$ in 5 years from 1998 to 2002. Annually, 2000 had the highest level With $1.80{\pm}0.15mSv$, While 1998 was lowest with $1.36{\pm}0.12mSv$, but a long-term solution needs to be worked out since there is a possibility of chronic exposure due to the nature of the work. The results of present research shows that the radiological technologists are effecting managing irradiation dose.

  • PDF

Accuracy of Dose Estimation in High Dose Rate Intracavitary Radiotherapy of Carcinoma of the Uterine Cervix (자궁경부암 고선량율 강내치료의 치료선량 정확도에 관한 연구)

  • Huh, Seung-Jae;Ha, Sung-Whan;Chai, Kyu-Young
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.137-140
    • /
    • 1987
  • In brachytherapy of uterine conical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. The post-treatment calculated point A dose was not much different from the pretreatment planned dose (500 cGy). The $average{\pm}standard$ deviation was $500\pm18cGy$ and 84 percent of 82 intracavitary radiotherapy was within the range of $500\pm25cGy$.

  • PDF

Performing angiographic intervention with a femoral entry shield: Element analysis microscopy and hand dose reduction for interventional radiologist

  • Law, Martin;Ng, Dickon H.L.;Yoon, Do-Kun;Djeng, Shih-Kien
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1318-1322
    • /
    • 2021
  • To unveil and delineate the elements applicable to the radiation protection of a femoral entry shield, calculate its mass attenuation coefficient, and demonstrate its dose reduction efficacy for interventional radiologist performing transarterial embolization (TAE) of ruptured hepatocellular carcinoma (rHCC). The lead equivalency of the shield was firstly validated. Electron microscopy was used to confirm the femoral entry shield being lead-free and to analyze the elemental content, with which the mass attenuation coefficient of the shield was calculated. An adult phantom, irradiated at the upper abdomen to simulate the TAE of rHCC, was used together with a dosimeter attached to the palm of a hand phantom. The dose rates at the hand phantom were measured, with the rHCC clinical protocol, without and with the femoral entry shield placed over the right femoral access site of the adult phantom. Without using the shield, the average hand dose rate was measured to be 0.325 µSv/sec. While using the shield, it was determined to be 0.110 µSv/sec. There was significant 66% dose reduction to the hand dose of IRs performing angiographic intervention with the femoral entry shield.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Influence of a Single Dose of Fe Dextran Administration with Organic Trace Mineral Supplementation on the Performance of Piglets

  • Acda, S.P.;Joo, J.W.;Kim, W.T.;Shim, Y.H.;Lee, S.H.;Chae, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.10
    • /
    • pp.1469-1474
    • /
    • 2002
  • This study was designed to evaluate the influence of a single or double dose of Fe dextran with organic trace mineral supplementation on the performance of piglets from dams fed diets with either inorganic (ITM) or organic trace minerals (OTM). It also determined the effect of the source of the trace minerals on the reproductive performance of sows. The trace mineral premixes were prepared using metal proteinates and the corresponding inorganic salts for the OTM and the ITM, respectively. Each mineral premix provided 100 ppm Fe/175 ppm Fe, 35 ppm Cu/170 ppm Cu, 90 ppm Zn/120 ppm Zn, and 40 ppm Mn/35 ppm Mn when added at 0.20% in sows /weaned pigs' diets, respectively. The first dose of Fe dextran was administered to piglets at 3 d and the second dose at 10 d after birth. One dose of Fe dextran supplied 100 mg of Fe. A total of 16 gestating sows (Landrace${\times}$Yorkshire) in parities 2 to 4 were randomly allocated to four treatments: 1) diet with ITM/one dose of Fe dextran to piglets, 2) diet with ITM/two doses of Fe dextran to piglets, 3) diet with OTM/one dose of Fe dextran to piglets, and 4) diet with OTM/two doses of Fe dextran to piglets. The total born alive, weaned, body weight at birth and at weaning were not affected by the sow's dietary treatment. Although organic trace mineral supplementation tended to increase the milk Fe content (p<0.10) at 7 d postpartum, piglets in all treatments performed equally from birth to weaning. The double doses of Fe dextran neither improved the average daily gain (ADG) nor influenced the survival of piglets from birth to weaning (21 d). Results suggest that a single dose of Fe dextran given to suckling pigs is adequate to sustain their needs for growth throughout the lactation period (21 d). Furthermore, there was a 21% improvement in both the ADG and the average daily feed intake (ADFI) (p<0.05) in weaned pigs fed diets with OTM. Cu and Fe in the liver (p<0.01), and Zn in both the bone (p<0.01) and the serum (p<0.01) were higher in piglets fed OTM than in those fed ITM. It would be concluded that single dose of Fe dextran administration with organic trace mineral supplementation show similar growth performance compared to 2 dose Fe dextran administration with inorganic mineral supplementation in young pigs.

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.