• 제목/요약/키워드: Auxiliary devices

검색결과 224건 처리시간 0.032초

넓은 입·출력전압 범위에서 제어 가능한 보조스위치 적용 LLC 공진컨버터 (LLC Resonant Converter with Auxiliary Switches Operating Over A Wide Output Voltage Range)

  • 이지철;김민지;오재성;김은수;국윤상
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.256-264
    • /
    • 2018
  • This paper proposes a three-bridge LLC resonant converter with auxiliary switches for a wide output voltage control range. This converter can be controlled in two ways to achieve a wide controllable output voltage control range of $V_o$ to $3V_o$. The first control mechanism is achieved through the pulse width modulation (PM) of the auxiliary switches and primary switching devices, while the second control mechanism is achieved through the frequency modulation (FM) of the primary switching devices that are configured to operate in the full-bridge switching mode when the auxiliary switches are turned off. The feasibility of using the proposed converter is verified by the results of an experiment with a 2kW prototype.

영전압 스위칭 3-레벨 보조 공진 폴 인버터 (Zero-voltage-switching three level auxiliary resonant commutated pole inverter)

  • 유동욱;원충연;조정구;백주원
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.535-542
    • /
    • 1996
  • A zero voltage switching (ZVS) three level auxiliary resonant commutated pole inverter (ARCPI) is presented for high power GTO inverters. The concept of ARCP for two level inverter is extended to the three inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching (ZCS) which enables use of the low cost thyristors. The proposed ARCPI can handle higher voltage and higher power (1-10MVA) comparing to the two level one. Operation and analysis of the ARCPI are illustrated and the features are compared o those of the snubber circuit incorporated three level inverter. Experimental results with 10kW, 4kHz prototype are presented to verify the principle of operation. (author). refs., figs., tab.

  • PDF

화력발전소 터빈 보조기기 제어 관한 고찰 (A Study on Turbine Auxiliary Devices in a Thermal Power Plant)

  • 정창기;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF

새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성 (Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber)

  • 성치호;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

치위생과와 비치위생과 학생의 잇솔질과 구강위생보조용품의 사용실태 비교연구 (A Comparative Study on for the Use of Auxiliary Oral Hygiene Devices and Tooth Brushing between Dental Hygiene Students and Non-Dental Hygiene Students)

  • 오혜승
    • 치위생과학회지
    • /
    • 제9권1호
    • /
    • pp.121-127
    • /
    • 2009
  • 본 연구는 S보건대학에 재학 중인 치위생과와 비치위생과 재학생 287여명을 대상으로 구강건강향상을 위한 잇솔질과 구강위생보조용품의 사용 실태를 비교 분석하여 다음과 같은 결론을 얻었다. 1. 잇솔질에 관한 특성부분에서 두과 모두 잇솔질 횟수는 하루에 2-3번(p < 0.05), 사용기간은 2-5개월(p > 0.05), 잇솔질 방법은 두 과 모두 안다고 조사되었으나(p > 0.05), 잇솔모의 사용에서는 치위생과는 보통모(51.2%), 비치위생과는 부드러운모(51.5%)로 조사되었다(p > 0.05). 2. 치실고리, 고무치간자극기, 물사출기, 혀세정기에 관한 인지도, 현재사용여부에서 두 과는 유의한 차이를 보이지 않았으나(p > 0.05), 용도이해부분에서 유의한 차이를 보였다(p < 0.05). 3. 전동칫솔, 가그린에 관한 인지도, 현재사용여부에서 두 과는 유의한 차이를 보이지 않았다(p > 0.05).

  • PDF

단일 보조 스위치를 이용한 새로운 ZVZCS PWM DC-DC 컨버터 (New ZVZCS PWM DC-DC Converters with One Auxiliary Swithch)

  • 류승희;이동윤;유상봉;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.188-194
    • /
    • 2000
  • This paper presents new Zero-Voltage-/Zero-Current-Switching (ZVZCS) PWM DC-DC converters. The proposed soft-switching technique achieves ZVS and ZCS simultaneously at both turn-on and turn-off of the main switch and diode by using only one auxiliary switch. Also, the proposed soft-switching technique is suitable for not only minority but also majority carrier semiconductor devices. The auxiliary circuit of the proposed topology is placed out the main power path and therefore, there are no voltage/current stresses on the main switch and diode. The operating principle of the proposed topology is illustrated by a detailed study with a boost converter as an example. Theoretical analysis, simulation and experimental results are presented to explain the proposed schemes.

  • PDF

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

EPET-WL: Enhanced Prediction and Elapsed Time-based Wear Leveling Technique for NAND Flash Memory in Portable Devices

  • Kim, Sung Ho;Kwak, Jong Wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권5호
    • /
    • pp.1-10
    • /
    • 2016
  • Magnetic disks have been used for decades in auxiliary storage devices of computer systems. In recent years, the use of NAND flash memory, which is called SSD, is increased as auxiliary storage devices. However, NAND flash memory, unlike traditional magnetic disks, necessarily performs the erase operation before the write operation in order to overwrite data and this leads to degrade the system lifetime and performance of overall NAND flash memory system. Moreover, NAND flash memory has the lower endurance, compared to traditional magnetic disks. To overcome this problem, this paper proposes EPET (Enhanced Prediction and Elapsed Time) wear leveling technique, which is especially efficient to portable devices. EPET wear leveling uses the advantage of PET (Prediction of Elapsed Time) wear leveling and solves long-term system failure time problem. Moreover, EPET wear leveling further improves space efficiency. In our experiments, EPET wear leveling prolonged the first bad time up to 328.9% and prolonged the system lifetime up to 305.9%, compared to other techniques.

치과내원 환자의 구강위생용품 인지와 이용에 관한 조사 (A Study on the Awareness and Use of Oral Hygiene Supplies by Dental Patients)

  • 양귀예;정선락;장지언
    • 보건의료산업학회지
    • /
    • 제9권4호
    • /
    • pp.91-103
    • /
    • 2015
  • Objectives : The purpose of this study was to examine the effects of sociodemographic characteristics on usage patterns of oral hygiene supplies of patients visiting a dental clinic. Methods : A questionnaire survey was administered to 592 patients visiting a dental clinic based in Daegu from December 2, 2013 through December 31, 2013. Statistical analysis was done with IBM SPSS Statistics 20.0. Results : For awareness of oral toothbrushes, electric toothbrushs had the highest ratio(67.6%), and for awareness of auxiliary oral hygiene devices, dental floss had the highest ratio (77.7%). For toothbrushes used, interdental brushes had the highest user ratio(34.3%), and for using auxiliary oral hygiene devices, dental floss had the highest ratio(37.7%). Age had an influence on the awareness of oral hygiene devices. Gender and Age had influence on the use of oral hygiene devices. Of the total respondents, 34.6% citied "do not need to do that" as the reason for not using oral hygiene supplies, followed by "do not know" (34%) and "it is tiresome" (30.4%). Conclusions : To effectively improve oral health status, a good motivation method necessary to promote the use of oral hygiene supplies.

산업용 열병합발전시스템에서 진화 알고리즘을 이용한 합리적 운전계획 수립에 관한 연구 (A Rational Operation Scheduling Using Evolutionary Algorithm on Industrial Cogeneration System)

  • 최광범;정지훈;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.494-501
    • /
    • 2000
  • This paper describes a strategy of a daily optimal operational scheduling in cogeneration system for paper mill. The cogeneration system selected to establish the scheduling consists of three units and several auxiliary devices. One unit generates electrical and thermal energy using the back pressure turbine. The rest two units generate the energy using the extraction condensing turbine. Three auxiliary boilers, two waste boilers and three sludge incinerators operate to supply energy to the loads with three units. The cogeneration system is able to supply enough the thermal energy to the thermal load, however it can not sufficiently supply the electrical power to the electrical load. Therefore the insufficient electric energy is compensated by buying electrical energy from utility. When the operational scheduling is performed considering the environmental problem. This paper shows the simulation results for daily operational scheduling obtained using the evolutionary algorithm. This results reveal that the proposed modeling and strategy can be effectively applied to cogeneration system for paper mill.

  • PDF