• 제목/요약/키워드: Automatic weighing

검색결과 24건 처리시간 0.026초

양식장 물김 이송 및 중량 자동측정 시스템 개발의 경제성 분석 연구 (Economic analysis of the loading-unloading and automatic weighing systems in laver aquaculture industry)

  • 김대현;민은비;강태종;황두진
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.181-187
    • /
    • 2023
  • Laver aquaculture, which occupies a large proportion in the aquaculture industry in Korea, is still highly dependent on human labor. Therefore, it is necessary to study the development of an automatic system to improve the working environment and increase the efficiency of aquaculture production systems. The purpose of this study is to evaluate the economic feasibility of an improved system in a study for the loading-unloading and automatic weighing systems in laver aquaculture industry. Economic analysis of the developed unloading and automatic weighing system were implemented under various conditions to calculate more accurate benefits and costs. As a result of this study, the economic feasibility was found to be very high in the three models: net present value (NPV), benefit-cost ratio (B/C), internal rate of return (IRR). Moreover, the results of sensitivity analysis showed that the economical efficiency of the automatic loading, unloading, and weighing system in laver aquaculture was very high.

A Study on the Optimum Scheme for Determination of Operation Time of Line Feeders in Automatic Combination Weighers

  • Keraita James N.;Kim Kyo-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1567-1575
    • /
    • 2006
  • In an automatic combination weigher, the line feeders distribute the product to several weighing hoppers. The ability to supply appropriate amount of product to the weighing hoppers for each combination operation is crucial for the overall performance. Determining the right duration of operating a line feeder to supply a given amount of product becomes very challenging in case of products which are irregular in volume or specific gravity such as granular secondary processed foods. In this research, several schemes were investigated to determine the best way for a line feeder to approximate the next operating time in order to supply a set amount of irregular goods to the corresponding weighing hopper. Results obtained show that a weighted least squares method (WLS) employing 10 data points is the most effective in determining the operating times of line feeders.

자동 저수와 배수가 가능한 중량 우량계 용 쌍수조 (A Paired Barrel Capable of Automatic Storage and Emptying of Water for a Weighing Raingauge)

  • 임규호;임은옥
    • 대기
    • /
    • 제27권2호
    • /
    • pp.251-258
    • /
    • 2017
  • The standard weighing raingauges have a capacity limit in measuring the amounts of precipitation. Exceptions are those using a siphon to drain the collected water during observations. To reduce the drain time of the siphon type or to overcome the hassles associated with the manual emptying of the bucket for measuring, the most of weighing gauges use a large bucket for storing of rainwater to be measured. To avoid the above-mentioned adverse requirements, we propose a paired barrel for a weighing raingauge. The paired barrel may improve the accuracy of the weighing raingauges by getting rid of their capacity limit and make the gauges smaller in size and lighter in weight than the conventional ones. We showed its proper function and the feasibility of realization by testing a prototype paired barrel.

동하중 측정 신호처리의 개발에 관한 연구 (A study on the development of dynamic weighing measurement system)

  • 박찬원;신형재;이영준;신영균;안광희
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.173-180
    • /
    • 1998
  • A high speed and stable A/D conversion data process is required to weigh a mass on moving conveyer weighing platter. The paper presents a new method to obtain stable and fast automatic weighing A/D conversion data process. Dynamic weighting system which is constructed with dual load cell is realized by the stable A/D conversion data process algorithm using DSP. The proposed method is applied to the real design, and that experimental results showed good performances of the weighing stability.

  • PDF

국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구 (Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards)

  • 남궁재관;공재향
    • 한국공작기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

The Design Method and Error Analysis of Machine Electronic Weighing Burden System controlled by a Computer Automatically

  • Zhang, Zhengou;Lin, Shanling
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.768-778
    • /
    • 1993
  • The system is designed for the production and processing of feed, fertilizer, sugar , and grain. It can be used to weigh and transport automatically their pellet, power or nonstickness materials. In this system, we use discontinuous totalising automatic weighing instruments to weigh materials. It is a closed-cycle control system controlled by industrial controlling computer STD bus. The system used for processing grain and feed can improve the quality of products , carry out scientific management, increase productivity and decrease the intensity of labour

  • PDF

자동배수형 무게식 강수량계 개발 및 강우량 측정 성능검사 (Development of Auto-Empting Type Weighing Precipitation Gauge and Performance Test on Rainfall Measurement)

  • 김상조;손탑
    • 대기
    • /
    • 제22권2호
    • /
    • pp.279-285
    • /
    • 2012
  • The weighing precipitation gauge with auto-empting capability was developed in the R&D project organized by the Research Agency for Climate Science (RACS) and supported by the Korea Meteorological Administration (KMA). This project was initiated in line with the KMA's plan executed since 2010 to introduce the weighing precipitation gauges partly into of their Automatic Weather Station (AWS) network in order to upgrade the quality of precipitation data. The innovative feature of this research is that the auto-empting in weighing precipitation gauge is realized by abrupt rotation of receiving container. The prototype was tested in compliance with the relevant standards of KMA. The results of performance test on rainfall measurement in laboratory verified that the accuracies for 20 mm and 100 mm reference rainfall amount were 0.1 mm and 0.4 mm, respectively in both conditions of auto-empting and no-empting. During the rotation of container for auto-empting, the data was extrapolated smoothly by applying the same precipitation intensity of the previous 10 sec. Consequently, it was found that the auto-empting precipitation gauge developed in this research is quite enough to be used for the operational purpose of accurate measurement with 0.1 mm resolution, regardless of the precipitation intensity.

휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발 (Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users)

  • 장경배;이경완;구도훈
    • 대한임베디드공학회논문지
    • /
    • 제8권1호
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.

로드셀을 이용한 생김 중량측정 방법에 관한 연구 (A study on the measurement method of raw laver weight using load cell)

  • 민은비;강태종;윤은아;김옥삼;황두진
    • 수산해양기술연구
    • /
    • 제59권3호
    • /
    • pp.215-220
    • /
    • 2023
  • This study developed and evaluated a load cell-based automatic weighing system for the automated harvesting of laver (Porphyra tenera) in seaweed aquaculture. The current manual harvesting process was compared with the load cell-based automated system, and quantitative measurements of time, distance, and weight were conducted. The results demonstrated that the load cell-based system reduced the unloading time and increased the throughput compared to the manual method. In addition, statistical analysis confirmed that there was no significant difference from the mean in the weight measurement obtained using the load cell-based system. Based on these findings, the load cell-based automatic weighing system holds potential for efficient production and transactions in laver cultivation, contributing to cost reduction and improving the quality of life for aquaculture workers.

젖소 사양기술의 자동화를 위한 연구 1. 임신유지 여부 및 질병자동진단 시스템개발 (Studies on Automatization of Dairy Cattle Farming 1. Development of Automatic System for Diagnosis of Pregnancy and Diseases)

  • 김용준;유일정;정길도;한병성;김동원;김명순
    • 한국임상수의학회지
    • /
    • 제14권2호
    • /
    • pp.301-307
    • /
    • 1997
  • These studies were performed to provide some basic informations for developing an automatic system in dairy farming cattle in order that the farmers may easily and automatically detect the maintenance of pregnancy and the fact of abortion of the pregnant cows and also to find out the diseased animals with fever. As a method of automatical detection of the maintenance of pregnancy or the fact of abortion, weighing the pregnant cows was conducted from one month-pregnancy to the term using a digital balance. From the first to the 3rd month of pregnancy the body weight of dairy cows was slowly increased (less than 2% per month), then, relatively high increase (3.4% -4.3% per month) from the fourth to the seventh month followed by decrease (3.3%) in the 8th month and very low increase (0.8-0.9%) from the 9th month to the term were shown, resulting in increase of 128.8 kg (25.05%) of body weight to be compared with the first weight. More than 107, increase of body weight to be compared with the first month-weight was denoted from the 61th month of pregnancy and more than 20% increase from the 7th or the 8th month of pregnancy as wells consequently it was presumed that detection of the maintenance of pregnancy is possible from the 4th or the 5th month of pregnancy. It was possible to diagnose a cow aborted at the 6th month by continual weighing the cow from the 1st month of pregnancy. The calved cows showed considerably higher decrease of body weight even in the third week after parturition (p<0.01)to be compared with the body weight near to the term (81.8-102.0 kg, 14-16% decrease). During the same period of 8months, the pregnant cows gained 127.4 kg (24.78% increase), whereas the non-pregnant cows gained 33.0 kg (0.71% increase) to be compared with the first weight showing considerably higher increase of body weight gain in the pregnant cows than the non-pregnant cows (p<0.01). The statistics of body temperatures of dairy cattle were collected from three clinics including the Teaching Hospital of Chonbuk University and the diseases were classified simply by the major symptoms manifested, denoting the highest temperature in respiratory disease ($39.8{\circ}C$) and the lowest in alimentary disease ($39.6{\circ} C$). These informations of body temperatures were expected to be of value for early and automatical detection of the diseased animals with fever when automatic machinery would be established. The results of periodic weighing the body weight of pregnant cows while milking were also expected to be of great use for the farmers to detect the maintenance of pregnancy and the fact of abortion when the automatic system is established in the near future.

  • PDF