• Title/Summary/Keyword: Automatic wave detection

Search Result 54, Processing Time 0.023 seconds

Automatic Seismic P-wave Detection Algorithm Using Variations of Impact Momentum (충격 추진력 변화를 이용한 지진 P파 자동 검출 알고리즘)

  • Choi, Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.884-891
    • /
    • 2018
  • In this paper, we propose an automatic earthquake P-wave detection algorithm based on the variations of the impact momentum derived from the seismic acceleration signals. The amount of change in the impact momentum induced by the acceleration refers to the influence of buildings or facilities on the earthquake, The proposed algorithm can effectively detect the seismic P-wave by simultaneously considering the amplitude and the frequency change of the seismic wave when the earthquake occurs. Computer simulations using the observed seismic signals were performed to evaluate the validity of the induced impact momentum variation and the superiority of the proposed algorithm.

Fixed and Moving Automatic FOD Detection Test using Radar and EO Camera (소형 Radar와 EO 카메라를 이용한 고정형 및 이동형 FOD 자동탐지 시험)

  • Kim, Young-Bin;Kim, Sung-Hee;Park, Myung-Kyu;Park, Kwang-Gun;Kim, Min-su;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.479-484
    • /
    • 2020
  • Foreign object debris (FOD) is a generic term for all substances that may pose a threat to aircraft operations on a runway. In the past, FOD detection and collection methods using human resources were very inefficient in terms of efficiency and economics, so it is essential to develop an unmanned FOD detection system suitable for domestic use. In this paper, the fixed FOD automatic detection system and mobile FOD automatic detection system using EO camera and radar were studied and developed at the Taean airfield of Hanseo University, and fixed and mobile method were operated to confirm that automatic FOD detection in the runway of the airfield is possible regardless of illumination and weather conditions.

Performance Comparison and Test of Fixed FOD Automatic Detection System and Moving FOD Automatic Detection System (고정형 이물질(FOD) 자동 탐지 시스템과 이동형 이물질 자동 탐지 시스템의 성능 비교 및 시험)

  • Kim, Sung-Hee;Hong, Jae-Beom;Park, Kwang-Gun;Choi, In-Kyu;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.6
    • /
    • pp.495-500
    • /
    • 2019
  • Foreign object debris (FOD) is a generic term for various metals and non-metal foreign object and materials with potential hazards to aircraft operations. Since the method of manual FOD detection and collection in the aircraft moving area is very low in efficiency and economic efficiency, it is essential to develop to FOD automatic detection system suitable for domestic environment. This paper is the result of the performance comparison test results of the two systems for the combined operation of each optimal detection time and 95% accuracy above 100 m for complex operation using the fixed FOD automatic detection system and the mobile FOD system using EO/IR camera and radar at Taean Airfield Hanseo University. It is expected that FOD can be performed unattended through continuous R & D.

A Belay Prevention Algorithm of Cardiac Depolarization Wave Detection for Pacemakers or Automatic Implantable Cardioverter/Defibrillator (AICD) (이식용 심장박동기(Pacemaker) 및 심장 세동제거기 (AICD)를 위한 심장 탈분극파 검출지연 방지 알고리즘)

  • Kim, J.K.;Park, C.K.;Han, S.H.;Cho, B.S.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1063-1066
    • /
    • 1999
  • The delay of cardiac depolarization wave detection in the conventional pacemakers or AICD (automatic implantable cardioverter/ defibrillator, or ICD) has been overlooked. However, it is known that the delay may cause hemodynamic problems and may prevent the proper operation of a new automatic feature, automatic capture verification, that is to be appeared in the near-future devices. In order to reduce the effects of the delay, a delay prevention algorithm was developed and tested by applying three human electrograms. The algorithm set the sensing threshold just above the measured noise level to reduce the detection delay. It is found that the low threshold was able to reduce the delay by 20msec(average) In most cases. The implementation results showed reliability and efficacy of the algorithm, and the algorithm could be applicable to the existing hardware and software of the conventional pacemakers and AICD without any significant modifications.

  • PDF

Automatic Detection of Slow-Wave Sleep Based on Electrocardiogram (심전도를 이용한 서파 수면 자동 검출 알고리즘 개발)

  • Yoon, Hee Nam;Hwang, Su Hwan;Jung, Da Woon;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.211-218
    • /
    • 2014
  • The objective of this research is to develop an automatic algorithm based on electrocardiogram (ECG) to estimate slow-wave sleep (SWS). An algorithm is based on 7 indices extracted from heart rate on ECG which simultaneously recorded with standard full night polysomnography from 31 subjects. Those 7 indices were then applied to independent component analysis to extract a feature that discriminates SWS and other sleep stages. Overall Cohen's kappa, accuracy, sensitivity and specificity of the algorithm to detect 30s epochs of SWS were 0.52, 0.87, 0.70 and 0.90, respectively. The automatic SWS detection algorithm could be useful combining with existing REM and wake estimation technique on unattended home-based sleep monitoring.

Automatic FOD Detection Test Using EO/ IR Laser Light Camera (EO / IR Laser Light 카메라를 이용한 FOD 자동탐지 시험)

  • Shin, Hyun-Sung;Hong, Gyo-Young;Hong, Jae-Beom;Choi, Young-Soo;Kim, Yun-Seob
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.638-642
    • /
    • 2017
  • FOD is a generic term for substances with potential threats that can pose a fatal risk to aircraft. Therefore, FOD should be noted in all areas of the airport. Especially, the method of detecting and collecting FOD in runway and aircraft movements is very low efficiency and economical efficiency of airport operation, so it is essential to develop FOD automatic detection system suitable for domestic environment. As part of the aviation safety technology development project, the development of an automatic detection system for foreign matter in the moving area of the aircraft inside the airport is underway. In this paper, it is confirmed that EO / IR camera is used for detection of foreign objects at Taean Airfield of Hanseo University. EO camera is used during the day and IR camera is used at night.

Automatic P300 Detection using ICA with Reference (Reference를 갖는 ICA를 이용한 자동적 P300 검출)

  • Park, Heeyoul;Park, Seungjin
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.193-195
    • /
    • 2003
  • The analysis of EEG data is an important task in the domain of Brain Computer Interface (BCI). In general, this task is extremely difficult because EEG data is very noisy and contains many artifacts and consists of mixtures of several brain waves. The P300 component of the evoked potential is a relatively evident signal which has a large positive wave that occurs around 300 msec after a task-relevant stimulus. Thus automatic detection of P300 is useful in BCI. To this end, in this paper we employ a method of reference-based independent component analysis (ICA) which overcomes the ordering ambiguity in the conventional ICA. We show here. that ICA incorporating with prior knowledge is useful in the task of automatic P300 detection.

  • PDF

Design of Arrhythmia Automatic Diagnostic System Using Decision Table (판정테이블을 이용한 부정맥 자동진단 시스템 설계에 관한 연구)

  • 정기삼;이재준
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.63-70
    • /
    • 1991
  • Design of Arrhythmia Automatic Diagnostic System Using Decision Table We have developed an arrhythmia automatic diagnostic system using decision table which is based on the criteria of Minnesota code. This system is divided into two Parts. One is wave detection algorithm using significant point extraction method, the other is arrhythmia diag- nostic algorthm. The proposed system allows physicians to diagnose more accurately by pro- viding the objective information about a lot of computer -processed ECG data.

  • PDF

A Study on the Defect Detection of Silicon-Chip Surrounding by Ultrasonic Wave - Automatic Determination Method of Threshold Value by Image Processing - (초음파를 이용할 실리콘 칩 주위의 결함 검출에 관한 연구 - 화상처리에 의한 threshold value의 자동 결정법 -)

  • 김재열;박환규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.87-94
    • /
    • 1991
  • This Paper is to aim the microdefect evaluation of semiconductor Package into a quantitative from NDI's image processing of ultrasonic wave. Accordingly, for the detection of delamination between the Joining condition of boundary microdefect of semiconductor packaga the result from sampling original image, histogramming, binary image or image processing of multinumerloal value is such as the follows. ([) The least limitation from the microdefect detection of the semiconductor package by surveying high ultrasonic wave seems to be about 0.8 $\mu\textrm{m}$ in degree. (2) A result of applying the image processing of multinumerical value to the semiconductor package it was possible to devide the Category into the effectiveness.

  • PDF

A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis (맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구)

  • Lee, J.Y.;Lee, J.W.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF