• Title/Summary/Keyword: Automatic measuring system

Search Result 356, Processing Time 0.031 seconds

Design of an Automatic Test System for Electronic Equipments in Vehicles (승용차용 전장시험 자동화 시스템 설계)

  • 이창훈;김유남
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.131-138
    • /
    • 2001
  • The performance analysis of an electronic equipment test is very complicate due to the variety o vehicles. In this study, automatic design system for the electronic equipment test has been carried out using the standard load patterns. For the test, standard signal patterns for each item are modeled. The test items can be decided by the user by means of these patterns. Also, engineering software modules are developed and proved to be very efficient for analyzing the test results statistically. Experiments are performed for the test system in the vehicle assembly line. By analyzing the test results, it is found that bad samples can be detected without failure. Also, the engineering software modules provide an analytical tool for the automation of the test process.

  • PDF

Development for Automatic Thickness Measurment System by Digital Image Processing (디지탈 이미지 프로세싱을 이용한 자동두께 측정장치 개발)

  • 김영일;이상길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.395-401
    • /
    • 1993
  • The purpose of this paper is to develop an automatic measuring system based on the digital image processing which can be applied to the in-process measurement of the characteristics of the thin thickness. The derivative operators is used for edge detection in gray level image. This concept can be easiliy illustrated with the aid of object shows an image of a simple light object on a dark background, the gray level profile along a horizontal scan line of the image, and the first and second derivatives of the profile. The first derivative of an edge modeled in this manner is () in all regions of constant gray level, and assumes a constant value during a gray level transition. The experimental results indicate that the developed qutomatic inspection system can be applied in real situation.

  • PDF

An obstacle avoidance system of an unmanned aerial vehicle using a laser range finder

  • Kim, Hyun;Miwa, Masafumi;Shim, Joonhwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.737-742
    • /
    • 2013
  • Recently, unmanned aircrafts for safe measurement in hazardous locations have been developed. In a method of operation of unmanned aircraft vehicles (UAV), there are two methods of manual control and automatic control. Small UAVs are used for low altitude surveillance flights where unknown obstacles can be encountered. Obstacle avoidance is one of the most challenging tasks which the UAV has to perform with high level of accuracy. In this study, we used a laser range finder as an obstacle detector in automatic navigation of unmanned aircraft to patrol the destination automatically. We proposed a system to avoid obstacles automatically by measuring the angle and distance of the obstacle using the laser range finder.

Reliability Engineering Approach to Fatigue Crack Growth Rate Under Random Loading Using DC Eletrical Potential Method (직류전위차법을 이용한 랜덤하중하의 피로균열 진전율에 대한 신뢰성 공학적 연구)

  • Bae, Sung-In
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.473-480
    • /
    • 1996
  • Automatic fatigue crack length measuring system using DC electrical potential method and the system control program for automatic fatigue testing under random load condition were made in this study. And using these system and control program, fatigue tests were executed under constant and random load condition. As the result, the propagation of crack in random loading can be represented Paris equaiton and log normal probability function. But constant and random load test show different crack propagation properties.

Stereo vision distance measurement algorithm using Laser point for Image processing based Automatic car-parking system (영상처리기반 자동주차 시스템을 위한 레이저 포인터를 이용한 스테레오 비전 거리측정 알고리즘)

  • Kim, Yoon-Ho;Lim, Myoung-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.373-376
    • /
    • 2007
  • As a part of automatic car parking, this paper have devised the distance measurement algorism using stereo vision system which measure between object and parking lot. In this simulation, laser pointer is used for detecting edge of designated object and real distance is measured by searching the position of laser pointer and measuring the distance. Which are 1 / 1.5 / 2 / 2.5 / 3m and adjusted correction had applied in order for use in car parking system.

  • PDF

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

Design of Data Processing System for the Automatic Measurement of the Reverberation Time (잔향시간의 자동측정을 위한 데이터 처리 시스템 설계)

  • 이근구
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1984.12a
    • /
    • pp.86-90
    • /
    • 1984
  • In this paper, a method measuring the reverberation time simultaneously on all of the audio frequency range was studied. The system developed in this study is composed of a pink noise generator, filter bank, and microcomputer with graphic display. In the experiment, reverbration time data measured by existing analog method and by the system were compared, and were almost same through the audio frequency. Based on the conclusion, the subject method has more convenience and accuracy with algorithm program development without existing problems and it was found out that this kind of method is widely available for many branches of room accoustics and architectual acoustics.

  • PDF

Quantitative Analysis of Oculomotor System by Automatic Identification Algorithm (자동 판별 알고리즘에 의한 동안계의 정량적인 해석)

  • 장인호;이세현
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.151-158
    • /
    • 1986
  • In this paper, the design and implementation of a microcomputer-based measuring system for quantitative analysis of oculomotor system are described. An algorithm for microcomputer analysis of electro-oculographicaay recorded horizontal saccadic eye movements is presented. From a brief, 4-min recording session detailed statistical information about saccade amplitude, duration, and velocity can be obtained.

  • PDF

Development of Displacement Measuring Sensor for Roll Eccentricity Contro1 at Hot Strip Mill (롤 편심제어를 위한 편심 측정장치 개발)

  • 전종학
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.167-167
    • /
    • 2000
  • This study aims at the development of REC sensor causing the gauge error in the hot strip rolling process, and the improvement of the hydraulic AGC (Automatic Gauge Control) system. The gauge error outbreaks from the various reasons, however, mainly the roll eccentricity is considered to cause a such kind of error. In the study, the REC (Roll Eccentricity Control System) sensor is designed using sensor An On - line test of the system shows the comprehensive effects of controlling the gauge error of the hot strip. On - Line test shows the possibility of enhancing the accuracy for gauge.

  • PDF

Development of an Automatic Expert System for Human Sensibility Evaluation based on Physiological Signal (생리신호를 기반으로 한 자동 감성 평가 전문가 시스템의 개발)

  • Jeong, Sun-Cheol;Lee, Bong-Su;Min, Byeong-Chan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2004
  • The purpose of this study was to develop an automatic expert system for the evaluation of human sensibility, where human sensibility can be inferred from objective physiological signals. The study aim was also to develop an algorithm in which human arousal and pleasant level can be judged by using measured physiological signals. Fuzzy theory was applied for mathematical handling of the ambiguity related to evaluation of human sensibility. and the degree of belonging to a certain sensibility dimension was quantified by membership function through which the sensibility evaluation was able to be done. Determining membership function was achieved using results from a physiological signal database of arousal/relaxation and pleasant/unpleasant that was generated from imagination. To induce one final result (arousal and pleasant level) based on measuring the results of more than 2 physiological signals and the membership function of each physiological signal. Dempster-Shafer's rule of combination in evidence was applied, through which the final arousal and pleasant level was inferred.