• Title/Summary/Keyword: Automated Evaluation

Search Result 504, Processing Time 0.027 seconds

Development of the Atomated Prediction System for Seasonal Tropical Cyclone Activity over the Western North Pacific and its Evaluation for Early Predictability (북서태평양 태풍 진로의 계절예측시스템 자동화 구축 및 조기 예측성의 검증)

  • Jin, Chun-Sil;Ho, Chang-Hoi;Park, Doo-Sun R.;Choi, Woosuk;Kim, Dasol;Lee, Jong-Ho;Chang, Ki-Ho;Kang, Ki-Ryong
    • Atmosphere
    • /
    • v.24 no.1
    • /
    • pp.123-130
    • /
    • 2014
  • The automated prediction system for seasonal tropical cyclone (TC) activity is established at the National Typhoon Center of the Korea Meteorological Administration (KMA) to provide effective operation and control of the system for user who lacks knowledge of the system. For automation of the system, two procedures which include subjective decisions by user are performed in advance, and their output data are provided as input data. To provide the capability to understand the operational processes for operational user, the input and output data are summarized with each process, and the directory structure is reconstructed following KMA's standard. We introduce a user interface using namelist input parameters to effectively control operational conditions which is fixed or should be manually set in the previous version of the prediction system. To operationally use early prediction which become available through the automation, its performances are evaluated according to initial condition dates. As a result, high correlations between the observed and predicted TC counts are kept for all track clusters even though advancing the initial condition date from May to January.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Evaluation of the clinical efficacy of a TW3-based fully automated bone age assessment system using deep neural networks

  • Shin, Nan-Young;Lee, Byoung-Dai;Kang, Ju-Hee;Kim, Hye-Rin;Oh, Dong Hyo;Lee, Byung Il;Kim, Sung Hyun;Lee, Mu Sook;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.237-243
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the clinical efficacy of a Tanner-Whitehouse 3 (TW3)-based fully automated bone age assessment system on hand-wrist radiographs of Korean children and adolescents. Materials and Methods: Hand-wrist radiographs of 80 subjects (40 boys and 40 girls, 7-15 years of age) were collected. The clinical efficacy was evaluated by comparing the bone ages that were determined using the system with those from the reference standard produced by 2 oral and maxillofacial radiologists. Comparisons were conducted using the paired t-test and simple regression analysis. Results: The bone ages estimated with this bone age assessment system were not significantly different from those obtained with the reference standard (P>0.05) and satisfied the equivalence criterion of 0.6 years within the 95% confidence interval (-0.07 to 0.22), demonstrating excellent performance of the system. Similarly, in the comparisons of gender subgroups, no significant difference in bone age between the values produced by the system and the reference standard was observed (P>0.05 for both boys and girls). The determination coefficients obtained via regression analysis were 0.962, 0.945, and 0.952 for boys, girls, and overall, respectively (P=0.000); hence, the radiologist-determined bone ages and the system-determined bone ages were strongly correlated. Conclusion: This TW3-based system can be effectively used for bone age assessment based on hand-wrist radiographs of Korean children and adolescents.

Automatic Detection of Off-topic Documents using ConceptNet and Essay Prompt in Automated English Essay Scoring (영어 작문 자동채점에서 ConceptNet과 작문 프롬프트를 이용한 주제-이탈 문서의 자동 검출)

  • Lee, Kong Joo;Lee, Gyoung Ho
    • Journal of KIISE
    • /
    • v.42 no.12
    • /
    • pp.1522-1534
    • /
    • 2015
  • This work presents a new method that can predict, without the use of training data, whether an input essay is written on a given topic. ConceptNet is a common-sense knowledge base that is generated automatically from sentences that are extracted from a variety of document types. An essay prompt is the topic that an essay should be written about. The method that is proposed in this paper uses ConceptNet and an essay prompt to decide whether or not an input essay is off-topic. We introduce a way to find the shortest path between two nodes on ConceptNet, as well as a way to calculate the semantic similarity between two nodes. Not only an essay prompt but also a student's essay can be represented by concept nodes in ConceptNet. The semantic similarity between the concepts that represent an essay prompt and the other concepts that represent a student's essay can be used for a calculation to rank "on-topicness" ; if a low ranking is derived, an essay is regarded as off-topic. We used eight different essay prompts and a student-essay collection for the performance evaluation, whereby our proposed method shows a performance that is better than those of the previous studies. As ConceptNet enables the conduction of a simple text inference, our new method looks very promising with respect to the design of an essay prompt for which a simple inference is required.

Comparative Evaluation of Cardiac Output using Echocardiography in Beagle Dogs (비글견에서 심초음파를 이용한 심박출량 측정에 관한 비교 연구)

  • Park, Kitae;Yeon, Seongchan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.384-390
    • /
    • 2012
  • Echocardiographic measurements of cardiac output, including the modified Simpson's method, Automated Contour Tracking(ACT) method, and left ventricular outflow method are well described methods of evaluating cardiac function due to its reliability and the benefits of its non-invasive technique in human medicine. The purpose of this study was to evaluate the accuracy of an echocardiography estimate of cardiac output in isoflurane-anesthetized beagle dogs and was to compare the ACT method to the other methods used in measurement of cardiac output. In healthy beagle dogs, cardiac output results by echocardiography estimate methods showed an excellent correlations with those by the thermodilution method (The modified Simpson's method : r = 0.815, $r^2=0.665$, y = 0.434x + 0.311 ; ACT method : r = 0.86, $r^2=0.748$, y = 0.391x + 0.242 ; ventricular outflow method : r = 0.691, $r^2=0.478$, y = 0.593x + 0.242). Among the results obtained, the ACT method showed the highest correlation coefficient. In conclusion, our study demonstrated that echocardiography estimate methods did not prove to be suitable in accurately measuring absolute cardiac output values but showed an excellent correlation with thermodilution method. Therefore, by using the measurement of cardiac output as supplemental data, echocardiography estimate methods can be used for detection and correction of hemodynamic disturbances during emergency and anesthesia in veterinary practice.

Application of an Automated Time Domain Reflectometry to Solute Transport Study at Field Scale: Transport Concept (시간영역 광전자파 분석기 (Automatic TDR System)를 이용한 오염물질의 거동에 관한 연구: 오염물질 운송개념)

  • Kim, Dong-Ju
    • Economic and Environmental Geology
    • /
    • v.29 no.6
    • /
    • pp.713-724
    • /
    • 1996
  • The time-series resident solute concentrations, monitored at two field plots using the automated 144-channel TDR system by Kim (this issue), are used to investigate the dominant transport mechanism at field scale. Two models, based on contradictory assumptions for describing the solute transport in the vadose zone, are fitted to the measured mean breakthrough curves (BTCs): the deterministic one-dimensional convection-dispersion model (CDE) and the stochastic-convective lognormal transfer function model (CLT). In addition, moment analysis has been performed using the probability density functions (pdfs) of the travel time of resident concentration. Results of moment analysis have shown that the first and second time moments of resident pdf are larger than those of flux pdf. Based on the time moments, expressed in function of model parameters, variance and dispersion of resident solute travel times are derived. The relationship between variance or dispersion of solute travel time and depth has been found to be identical for both the time-series flux and resident concentrations. Based on these relationships, the two models have been tested. However, due to the significant variations of transport properties across depth, the test has led to unreliable results. Consequently, the model performance has been evaluated based on predictability of the time-series resident BTCs at other depths after calibration at the first depth. The evaluation of model predictability has resulted in a clear conclusion that for both experimental sites the CLT model gives more accurate prediction than the CDE model. This suggests that solute transport at natural field soils is more likely governed by a stream tube model concept with correlated flow than a complete mixing model. Poor prediction of CDE model is attributed to the underestimation of solute spreading and thus resulting in an overprediction of peak concentration.

  • PDF

Closed Static Chamber Methods for Measurement of Methane Fluxes from a Rice Paddy: A Review (벼논 메탄 플럭스 측정용 폐쇄형 정적 챔버법: 고찰)

  • Ju, Okjung;Kang, Namgoo;Lim, Gapjune
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.2
    • /
    • pp.79-91
    • /
    • 2020
  • Accurate assessment of greenhouse gas emissions is a cornerstone of every climate change response study, and reliable assessment of greenhouse gas emission data is being used as a practical basis for the entire climate change prediction and modeling studies. Essential, fundamental technologies for estimating greenhouse gas emissions include an on-site monitoring technology, an evaluation methodology of uncertainty in emission factors, and a verification technology for reductions. The closed chamber method is being commonly used to measure gas fluxes between soil-vegetation and atmosphere. This method has the advantages of being simple, easily available and economical. This study presented the technical bases of the closed chamber method for measuring methane fluxes from a rice paddy. The methane fluxes from rice paddies occupy the largest portion of a single source of greenhouse gas in the agricultural field. We reviewed the international and the domestic studies on automated chamber monitoring systems that have been developed from manually operated chambers. Based on this review, we discussed scientific concerns on chamber methods with a particular focus on quality control for improving measurement reliability of field data.

Evaluation of the Effectiveness of Surveillance on Improving the Detection of Healthcare Associated Infections (의료관련감염에서 감시 개선을 위한 평가)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The development of reliable and objective definitions as well as automated processes for the detection of health care-associated infections (HAIs) is crucial; however, transformation to an automated surveillance system remains a challenge. Early outbreak identification usually requires clinicians who can recognize abnormal events as well as ongoing disease surveillance to determine the baseline rate of cases. The system screens the laboratory information system (LIS) data daily to detect candidates for health care-associated bloodstream infection (HABSI) according to well-defined detection rules. The system detects and reserves professional autonomy by requiring further confirmation. In addition, web-based HABSI surveillance and classification systems use discrete data elements obtained from the LIS, and the LIS-provided data correlates strongly with the conventional infection-control personnel surveillance system. The system was timely, acceptable, useful, and sensitive according to the prevention guidelines. The surveillance system is useful because it can help health care professionals better understand when and where the transmission of a wide range of potential pathogens may be occurring in a hospital. A national plan is needed to strengthen the main structures in HAI prevention, Healthcare Associated Prevention and Control Committee (HAIPCC), sterilization service (SS), microbiology laboratories, and hand hygiene resources, considering their impact on HAI prevention.

A Study on Real-Time SOC Structure Behavior Evaluation System using Big Data (Big data를 이용한 실시간 SOC 구조물 거동분석 시스템 연구)

  • Jung-Youl Choi;Jae-Min Han;Dae-Hui Ahn;Jee-Seung Chung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.691-695
    • /
    • 2023
  • Currently, the utilization of measurement results of the automated measurement system is very low and is at the level of providing only fragmentary measurement results. In this study, we are going to study a structure behavior analysis 3D display system with high precision and reliability for automated measurement data obtained by constructing big data by transmitting massive data values measured in real time to the cloud and using a Python-based algorithm. As a result of the study, as a system that can evaluate the behavior of a structure to a manager in real time, it provides analysis data in real time without significant restrictions regardless of the type of measurement data and sensor, and derived it as a 3D display. In addition, it was analyzed that the manager could grasp the behavior graph of the structure in real time and more easily judge the derivation of the weak part of the structure through data analysis. In the future, by analyzing the behavior of structures in three dimensions using past and present data, it is expected that more effective measurement results can be obtained in terms of repair, reinforcement, and maintenance of realistic structures.

A Combat Effectiveness Evaluation Algorithm Considering Technical and Human Factors in C4I System (NCW 환경에서 C4I 체계 전투력 상승효과 평가 알고리즘 : 기술 및 인적 요소 고려)

  • Jung, Whan-Sik;Park, Gun-Woo;Lee, Jae-Yeong;Lee, Sang-Hoon
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.2
    • /
    • pp.55-72
    • /
    • 2010
  • Recently, the battlefield environment has changed from platform-centric warfare(PCW) which focuses on maneuvering forces into network-centric warfare(NCW) which is based on the connectivity of each asset through the warfare information system as information technology increases. In particular, C4I(Command, Control, Communication, Computer and Intelligence) system can be an important factor in achieving NCW. It is generally used to provide direction across distributed forces and status feedback from thoseforces. It can provide the important information, more quickly and in the correct format to the friendly units. And it can achieve the information superiority through SA(Situational Awareness). Most of the advanced countries have been developed and already applied these systems in military operations. Therefore, ROK forces also have been developing C4I systems such as KJCCS(Korea Joint Command Control System). And, ours are increasing the budgets in the establishment of warfare information systems. However, it is difficult to evaluate the C4I effectiveness properly by deficiency of methods. We need to develop a new combat effectiveness evaluation method that is suitable for NCW. Existing evaluation methods lay disproportionate emphasis on technical factors with leaving something to be desired in human factors. Therefore, it is necessary to consider technical and human factors to evaluate combat effectiveness. In this study, we proposed a new Combat Effectiveness evaluation algorithm called E-TechMan(A Combat Effectiveness Evaluation Algorithm Considering Technical and Human Factors in C4I System). This algorithm uses the rule of Newton's second law($F=(m{\Delta}{\upsilon})/{\Delta}t{\Rightarrow}\frac{V{\upsilon}I}{T}{\times}C$). Five factors considered in combat effectiveness evaluation are network power(M), movement velocity(v), information accuracy(I), command and control time(T) and collaboration level(C). Previous researches did not consider the value of the node and arc in evaluating the network power after the C4I system has been established. In addition, collaboration level which could be a major factor in combat effectiveness was not considered. E-TechMan algorithm is applied to JFOS-K(Joint Fire Operating System-Korea) system that can connect KJCCS of Korea armed forces with JADOCS(Joint Automated Deep Operations Coordination System) of U.S. armed forces and achieve sensor to shooter system in real time in JCS(Joint Chiefs of Staff) level. We compared the result of evaluation of Combat Effectiveness by E-TechMan with those by other algorithms(e.g., C2 Theory, Newton's second Law). We can evaluate combat effectiveness more effectively and substantially by E-TechMan algorithm. This study is meaningful because we improved the description level of reality in calculation of combat effectiveness in C4I system. Part 2 will describe the changes of war paradigm and the previous combat effectiveness evaluation methods such as C2 theory while Part 3 will explain E-TechMan algorithm specifically. Part 4 will present the application to JFOS-K and analyze the result with other algorithms. Part 5 is the conclusions provided in the final part.