• Title/Summary/Keyword: Automated Evaluation

Search Result 504, Processing Time 0.024 seconds

Evaluation of the Manual Method of Liquid-Based Uterine Cervicovaginal Cytology - By The Manual Method Based on $SurePath^{TM}$ Methodology (자궁경부 액상세포검사의 수기 검사법에 대한 고찰 - $SurePath^{TM}$ 검사법을 준용한 수기 검사법으로 -)

  • Park, Jong-Myoung;Jang, Jin-Wook;Lim, So-Yeo;Suh, In-Soo;Lee, Jong-Gi
    • The Korean Journal of Cytopathology
    • /
    • v.15 no.2
    • /
    • pp.86-91
    • /
    • 2004
  • Liquid-Based Uterine Cervicovaginal Cytology is known to be a sensitive and effective screening method for cervical neoplasm $MonoPrep^{TM},\;ThinPrep^{TM},\;and\;SurePath^{TM}$ methods have been recently used as Liquid-Based Uterine Cervicovaginal Cytology techniques, and the $SurePath^{TM}$ method has been used in Sung-Yoon Reference Laboratory since 2003. The goal of Liquid-Based Uterine Cervicovaginal Cytology is to separate cervical epithelial cells from non-target cells, red blood cells and neutrophils. This report describes a study which evaluated cellularity, stainablilty, and cellular changes of epithelial cels in samples processed using a manual technique as compared to samples processed using $SurePath^{TM}$ automated method. The samples processed by means of a manual technique contained a cellularity of epithelial cells similar to that of the samples processed using the $SurePath^{TM}$ automated method. In addition, we compared variable density gradient reagents, including dextran, dextrose, and sucrose, to $SurePath^{TM}$ gradient media in order to evaluate cell fractionation and cellularity of epithelial cells. 10% dextran of gradient media shows good fractionation. The samples processed with 10% dextran demonstrated sufficient cellularity of epithelial cells and shows the fewest cellular changes. In conclusion, using a manual technique on these samples is easier to read than those results obtained using the $SurePath^{TM}$ automated method.

Simulation-based Evaluation of AGV Operation at Automated Container Terminal (시뮬레이션을 이용한 자동화 컨테이너 터미널의 AGV 운영평가)

  • Ha Tae-Young;Choi Yong-Seok;Kim Woo-Sun
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.891-897
    • /
    • 2004
  • This paper provided a simulation model for transport vehicles that carry container from the ship to yard block and vice versa at automated container terminal with a perpendicular yard layout. Usually, the efficiency of container terminal is evaluated by the productivity of container cranes at apron, and the stevedoring system for transport vehicles and yard cranes should be supported enough to improve productivity of container cranes. Especially, transport vehicle is very important factor in the productivity of container cranes and the performance of transport vehicles are changed according to the number and traveling type of vehicles. For these reason, a method that can estimate productivity of transport vehicle is required Finally, we developed the simulation model to analyze the productivity of transport vehicle and presented the productivity of container cranes for a varying operation of transport vehicles.

Government Website Accessibility: Comparison between Korea and the United States (한국과 미국 정부기관의 웹사이트 접근성 평가)

  • Hong, Soon-Goo;Cho, Jae-Hyung;Lee, Dae-Hyung
    • Information Systems Review
    • /
    • v.7 no.1
    • /
    • pp.81-96
    • /
    • 2005
  • Because the web sites are in common today, the access to the web for disabled people and old aging people, what we call accessibility, becomes more important. Even though efforts to reduce the informational gap resulted from the lack of the accessibility have been carried out, the studies in this field in Korea are not still in popular. In this study, previous research on the measurements for the accessibility is reviewed and then a new model measuring accessibility is suggested. To increase the validity of the measurement, both an automated tool and a manual test are employed. First we used the 'A-Prompt', one of the popular automated validation tools and analyzed web sources, and applied manual tests by HPR Screen Reader. With the error rates calculated, the accessibility of the government web sites between Korea and the United States was compared and finally the conclusions were drawn.

Evaluation of Negative Results of BacT/Alert 3D Automated Blood Culture System

  • Kocoglu M. Esra;Bayram Aysen;Balcl Iclal
    • Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.257-259
    • /
    • 2005
  • Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (BPA) and anaerobic (BPN) media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in $5\%$ sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four $(2.6\%)$ of the 904 subcultures grew on the subculture media. The majority $(83.3\%)$ of these were determined to be gram-positive microorganisms. Fourteen $(58.3\%)$ were coagulase-negative staphylococci, two $(8.3\%)$ were Bacillus spp., one $(4.2\%)$ was Staphylococcus aureus, and one $(4.2\%)$ was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two $(8.3\%)$ vials. Gram-negative microorganisms comprised $12.5\%$ of the subcultures, of which two $(8.3\%)$ were found to be Pseudomonas aeruginosa, and one $(4.2\%)$ was Pseudomonas fluorescens. The other isolate $(4.2\%)$ was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

Development of Automated Inversion Method for HWAW Method Using Genetic Algorithm (유전자 알고리즘을 이용한 HWAW 방법을 위한 자동화 역산 방법의 개발)

  • Park, Hyung-Choon;Hwang, Hea-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.8
    • /
    • pp.55-63
    • /
    • 2012
  • The evaluation of shear modulus (or shear wave velocity) profile of the site is very important in various fields of geotechnical engineering and various surface wave methods have applied to determine the shear wave velocity profiles and showed good performance. Surface wave methods evaluate the dispersion curve in the field and determine the shear wave velocity profile through the inversion process. In this paper, the automated inversion process using the genetic algorithm is developed for HWAW method which is one of surface wave methods recently developed. The proposed method uses the error function based on the wavelength domain dispersion curve and can determine the reliable shear wave velocity profile not only in shallow depth but also in deep depth. To estimate the validity of the proposed method, numerical simulations and field test were performed and the proposed method was applied to determine the shear wave velocity profiles. Through the numerical simulations and field applications, the promising potential of the proposed method was verified.

AGV Dispatching with Stochastic Simulation (확률적 시뮬레이션 기반 AGV 배차)

  • Choe, Ri;Park, Tae-Jin;Ryu, Kwang-Ryel
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.837-844
    • /
    • 2008
  • In an automated container terminal, various factors affect the operation of container handling equipment such as quay cranes and AGVs, and thus calculating the exact operation time is nearly infeasible. This uncertainty makes it difficult to dispatch AGVs well. In this paper, we propose a simulation-based AGV dispatching algorithm When dispatching an AGV to an operation, the proposed algorithm conducts multiple stochastic simulation for the succeeding AGV operations for the predetermined period to collect stochastic samples of the result of the dispatching. In the stochastic simulation, the uncertainty of crane operations is represented as a simple probability distribution and the operation time of a crane is determined according to this. A dispatching option is evaluated by the total delay time of quay cranes which is estimated by averaging the quay crane delay of each simulation In order to collect a sufficient number of samples that guarantee the credibility of the evaluation, we devised a high-speed simulator that simulates AGV operation The effectiveness of the proposed algorithm is validated by simulation experiments.

Evaluation of a multi-stage convolutional neural network-based fully automated landmark identification system using cone-beam computed tomography-synthesized posteroanterior cephalometric images

  • Kim, Min-Jung;Liu, Yi;Oh, Song Hee;Ahn, Hyo-Won;Kim, Seong-Hun;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.77-85
    • /
    • 2021
  • Objective: To evaluate the accuracy of a multi-stage convolutional neural network (CNN) model-based automated identification system for posteroanterior (PA) cephalometric landmarks. Methods: The multi-stage CNN model was implemented with a personal computer. A total of 430 PA-cephalograms synthesized from cone-beam computed tomography scans (CBCT-PA) were selected as samples. Twenty-three landmarks used for Tweemac analysis were manually identified on all CBCT-PA images by a single examiner. Intra-examiner reproducibility was confirmed by repeating the identification on 85 randomly selected images, which were subsequently set as test data, with a two-week interval before training. For initial learning stage of the multi-stage CNN model, the data from 345 of 430 CBCT-PA images were used, after which the multi-stage CNN model was tested with previous 85 images. The first manual identification on these 85 images was set as a truth ground. The mean radial error (MRE) and successful detection rate (SDR) were calculated to evaluate the errors in manual identification and artificial intelligence (AI) prediction. Results: The AI showed an average MRE of 2.23 ± 2.02 mm with an SDR of 60.88% for errors of 2 mm or lower. However, in a comparison of the repetitive task, the AI predicted landmarks at the same position, while the MRE for the repeated manual identification was 1.31 ± 0.94 mm. Conclusions: Automated identification for CBCT-synthesized PA cephalometric landmarks did not sufficiently achieve the clinically favorable error range of less than 2 mm. However, AI landmark identification on PA cephalograms showed better consistency than manual identification.

Evaluation Of LoRaWAN In A Highly Dense Environment With Design Of Common Automated Metering Platform (CAMP) Based On LoRaWAN Protocol

  • Paul, Timothy D;Rathinasabapathy, Vimalathithan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.5
    • /
    • pp.1540-1560
    • /
    • 2022
  • Latest technological innovation in the development of compact lower power radios has led to the explosion of Internet of Things. With Wi-Fi, Zigbee and other physical layer protocols offering short coverage area there was a need for a RF protocol that had a larger coverage area with low power consumption. LoRa offers Long Range with lower power consumption. LoRa offers point to point and point to multipoint connections. with Single hop communication in place the need for routing protocols are eliminated. LoRa Wide Area Network stack can accommodate thousands of nodes under a single LoRa gateway with a single hop communication between the end nodes and LoRaWAN gateway. This paper takes an experimental approach to analyze the basic physical layer parameters of LoRa and the practical coverage offered by a LoRaWAN under highly dense urban conditions with variable topography. The insights gained from the practical deployment of the LoRaWAN network, and the subsequent performance analysis is used to design a novel public utility monitoring platform. The second half of the papers is designing a robust platform to integrate both existing wired sensor water meters, current and future generation wireless water meters. The Common Automated Metering Platform is designed to integrate both wired sensors and wireless (LoRaWAN and Wi-Fi) supported water meters. This integrated platform reduces the number of nodes under each LoRaWAN gateway and thus improves the scalability of the network. This architecture is currently designed to accommodate one utility application but can be modified to integrate multi-utility applications.

Automated Breast Ultrasound System for Breast Cancer Evaluation: Diagnostic Performance of the Two-View Scan Technique in Women with Small Breasts

  • Bo Ra Kwon;Jung Min Chang;Soo Yeon Kim;Su Hyun Lee;Soo-Yeon Kim;So Min Lee;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.25-32
    • /
    • 2020
  • Objective: To comparatively evaluate the scan coverage and diagnostic performance of the two-view scan technique (2-VST) of the automated breast ultrasound system (ABUS) versus the conventional three-view scan technique (3-VST) in women with small breasts. Materials and Methods: Between March 2016 and May 2017, 136 asymptomatic women with small breasts (bra cup size A) suitable for 2-VST were enrolled. Subsequently, 272 breasts were subjected to bilateral whole-breast ultrasound examinations using ABUS and the hand-held ultrasound system (HHUS). During ABUS image acquisition, one breast was scanned with 2-VST, while the other breast was scanned with 3-VST. In each breast, the breast coverage and visibility of the HHUS detected lesions on ABUS were assessed. The sensitivity and specificity of ABUS were compared between 2-VST and 3-VST. Results: Among 136 breasts, eight cases of breast cancer were detected by 2-VST, and 10 cases of breast cancer were detected by 3-VST. The breast coverage was satisfactory in 94.1% and 91.9% of cases under 2-VST and 3-VST, respectively (p = 0.318). All HHUS-detected lesions were visible on the ABUS images regardless of the scan technique. The sensitivities and specificities were similar between 2-VST and 3-VST (100% [8/8] vs. 100% [10/10], and 97.7% [125/128] vs. 95.2% [120/126], respectively), with no significant difference (p > 0.05). Conclusion: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.

Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging

  • Bo Ra Kwon;Jung Min Chang;Soo-Yeon Kim;Su Hyun Lee;Sung Ui Shin;Ann Yi;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1210-1219
    • /
    • 2020
  • Objective: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). Materials and Methods: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. Results: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). Conclusion: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.