• Title/Summary/Keyword: Autoclave Test

Search Result 114, Processing Time 0.031 seconds

Moisture Diffusion Analysis for Bendable Electronic Module Under Autoclave Test Condition (유연성 전자모듈에 대한 오토클레이브 시험조건에서의 습기확산해석)

  • Han, Chang-Woon;Oh, Chul-Min;Hong, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.523-528
    • /
    • 2012
  • A bendable electronic module is developed for a mobile application by using a low-cost roll-to-roll manufacturing process. In the module, a thin silicon chip is embedded in a polymer-based encapsulating adhesive between flexible copper clad polyimide layers. A set of tests are conducted for the purpose of qualification: thermal shock, high temperature storage, and autoclave tests. During the autoclave test, delamination occurs at many places within the module layers. To investigate the failure mechanism, moisture diffusion analysis is conducted for the interior of the module under the autoclave test condition. For the analysis, the hygroscopic characteristics of the encapsulating materials are experimentally determined. Analysis results indicate the moisture saturation process in the interior of the module under the autoclave test condition.

The Study on the Surface Properties of Concrete Tile According to the Autoclave Curing (오토클레이브 양생에 따른 콘크리트 마감재의 표면특성에 관한 연구)

  • Choi Sun-Mi;Jung Ji-Yong;Jung Eun-Hye;Kawg Eun-Gu;Kim Jin-man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.77-80
    • /
    • 2005
  • The surface of concrete tiles is weak in moisture that it occurrenced efflorescence, but in the former study we found that it is possible to ensure moisture stability of concrete surface by autoclaving. So this study is to discuss the moisture stability and Physical Properties of high-strength glossy concrete according to time and temperature of autoclave curing. As the results, by increasing time and temperature of autoclave curing, compressive strength and surface hardness increased and glossiness decreased. In the case to 3 hour and $180^{\circ}C$ of autoclave curing, there is not effloescences in mosture stability test.

  • PDF

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

Development of Micro Displacement Extensometer for Environmental Fatigue Test in a High Temperature and High Pressure Autoclave (고온고압 환경피로실험 오토클래이브 내부용 미소변위 측정장치 개발)

  • Jeong, Ill-Seok;Ha, Gak-Hyun;Kim, Tae-Ryong;Jeon, Hyun-Ik;Kim, Young-Sin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.368-371
    • /
    • 2008
  • An extensometer system to measure strain and displacement of cylindrical fatigue specimen in a autoclave of high temperature and high pressure environment has been developed by KEPRI. The extensometer reads the displacement caused by fatigue loads at the target length of the specimen installed inside the autoclave. The performance of the extensometer were tested at 15MPa, $315^{\circ}C$ of a operating pressurized water reactor. Two LVDT's of magnet type were connected to the extensometer and used for converting the fatigue displacement to electronic signal. The device is being used for developing environmental fatigue curve of CF8M cast austenitic stainless steel (CASS) in the test condition of low cycle and low strain. This paper introduces the background and results of the development.

  • PDF

Morphological aspect of the attached bacteria by the sterilization method of the ultrasonic scaling tip (소독멸균 방법에 따른 초음파 스케일링 팁에 부착된 세균의 양상)

  • Nam, Seoul-Hee;Kim, Yu-rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.713-718
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the bacterial morphology attached on ultrasonic scaler tips using no cleansing solution, alcohol cotton, liquid chemical disinfecting agent, and autoclave method. Methods: Scaling tip was applied to the mouth and the ultrasonic scaler tips were assigned to four groups. Group 1 was control group with no cleansing solution. Group 2 was treated with alcohol cotton. Group 3 was treated with 2% green Y-Na solution in liquid chemical disinfecting agent, and Group 4 was sterilized by autoclave method. Live bacteria were observed by phase contrast microscopy. The scanning electron microscopy(SEM) revealed the morphological characteristics of scaler surface. The type of attached bacteria were analyzed using SPSS 21.0 program. The data were analyzed by one-way analysis of variance(ANOVA) and Tukey's post-hoc test. Results: The types of sterilization methods had influences on the bacterial viability. The numbers of cocci, bacilli, spiral form bacteria, and filamentous bacteria was observed in $89.00{\pm}3.60%$, $29.67{\pm}3.51%$, $3.33{\pm}0.57%$ and $1.67{\pm}0.57%$ in control group, $31.67{\pm}3.51%$, $63.33{\pm}4.04%$, $2.00{\pm}1.00%$ and $1.67{\pm}0.57%$ in alcohol cotton group, $69.67{\pm}4.50%$, $12.33{\pm}2.51%$, 0% and 0% in liquid chemical disinfecting agent group, and 0.0%, 0.0%, 0.0% and 0.0% in autoclave method group. The clean surface of ultrasonic scaler tip was shown on SEM by autoclave method. Conclusions: The most effective sterilization method of ultrasonic scaler tip was the autoclave method. Autoclave method is the most effective sterilization method and can reduce the cross-infection in the dental clinic.

Analysis of Bending characteristics of Autoclave Forming CFRP Structural Members

  • Kim, Jung-Ho;Kim, Ji-Hoon
    • Journal of Korea Foundry Society
    • /
    • v.28 no.4
    • /
    • pp.175-178
    • /
    • 2008
  • 우주선, 항공기, 수송차량 등은 기능은 집적 다양화 그리고 성능의 고도와 됨에 따라 에너지 효율성을 위해 구조부재의 경량화가 중요성은 증가되고 있다. 경량화 구조부재 재료 중에는 알루미늄 합금, 세라믹, 복합재료 등이 개발되어 우주선, 항공기, 수송차량 구조부재에 적용하기 위한 많은 연구가 이루어지고 있다. 이들 중, 20세기 초 알루미늄합금이 초 경량화 구조부재로서 많이 이용되었다. 본 논문에서는 경량화 재료 중 이방성을 가지는 복합재료를 구조부재에 적용하였다. 그러나 구조부재에 적용되기 위한 이방성 복합 재료는 강한 충격 이후 취성의 특징 때문에 하중과 흡수에너지가 급속히 감소하는 단점을 가지고 있다. 그래서 이방성 복합재료의 각 층간을 완전히 접합하여 성질이 매우 우수한 부재를 제작할 수 있는 Autoclave 성형법으로 제작하였다. 이방성 복합재료 중 CFRP를 설계 메커니즘 변수에 따라 Autoclave 성형을 하고 하중과 흡수에너지가 높음 평가하기 위해 굽힘실험을 하였다.

A Study on Durability of High Strength Concrete (고강도(高强度)콘크리트의 내구성(耐久性)에 관한 연구(研究))

  • Kim, Saeng Bin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.9-19
    • /
    • 1981
  • Using superplasticizer or the methods of autoclave curing is the most typical and practical of the ways to make high strength concrete. In this study the high strength concrete piles by way of centrifugal forming and hand compacting, are put to the freezing and thawing test after the process of autoclave curing, water curing after steam curing, or stand water curing. And the relation of such piles to durability, the rate of strength decrease, and the rate of weight variation is shown. The durability of those test piles throughout freezing and thawing test proves to be comparatively sufficient in the above-mentioned curings when the piles contain a proper quantity of air. But it is also acknowledged that without A.E agent, the high strength concrete piles of autoclave curing is higher than those of the other curing in strength, but lower in modulus of dynamic elasticity and their durability factor after the test is much lower.

  • PDF

A Study on the aging characteristics of Suspension insulators (현수애자의 경년변화 특성에 관한 연구)

  • 송일근;김상준;김주용;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 1996
  • This paper describes thermal-mechanical performance and ultimate mechanical-strength test for the purpose of aging analysis of suspension insulator. The temperature of insulator surface according to the aging of suspension insulator was rised about 2[$^{\circ}C$] to 7~8[$^{\circ}C$] difference comparing with the atmospheric temperature. The autoclave expansion of portland cement at the specimen that had much puncture insulator(autoclave measuring value : 0.37[%]) was higher than those of a little puncture insulator (autoclave measuring value : 0.1[ %] ). Quality standard and mechanical-strength of used suspension insulator deteriorate more remarkably than those of new suspension insulator. It is required that thermal-mechanical performance test standard be revised in the future.

  • PDF

A Study on the Reliability of Cooling Water Systems Using R436B (대체냉매 R436B를 적용한 정수기 냉각수 시스템 신뢰성 평가에 관한 연구)

  • Nam, Hyun-Kyu;Bai, Sangeun;Bai, Cheol-Ho;Ko, Jung-Su;Jin, Byung-Joo;Oh, Ju-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.438-442
    • /
    • 2013
  • The alternative refrigerant R436B is applied, to assess the application feasibility for a commercial cooling water system. The characteristic stability was verified by Sealed glass tube test and Autoclave test. R436B is chemically stable with the compressor material. The Oil miscibility test shows the usual compressor oil mixed well with R436B. Through the life acceleration test, the cooling performance is maintained. Though slight changes in oil and capillary tube diameter were found, they were within the permitted range. R436B should be applied to commercial cooling water systems as a simple replacement for the usual refrigerant.

Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel (CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성)

  • Jeong, Il-Seok;Ha, Gak-Hyun;Kim, Tae-Ryong;Jeon, Hyun-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.2
    • /
    • pp.177-185
    • /
    • 2008
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor (PWR). The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside a small autoclave. So the magnet type LVDT#s were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. Displacement of the fatigue specimen gauge length calculated by FEM (finite element method) used to modify the measured displacement and fatigue life at the shoulders. A series of low cycle fatigue life tests in air and PWR conditions simulating the cyclic strain hardening effect verified that the FEM modified fatigue life was well agreed with the simulating test results. The process and method developed in this study for the environmental fatigue test inside the small sized autoclave would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.