• Title/Summary/Keyword: Auto-fluorescence

Search Result 11, Processing Time 0.027 seconds

Development and Evaluation of Multi-Wavelength Excitation light Source for Fluorescence Imaging to Diagnose Malignancies (악성종양의 형광영상 진단을 위한 다파장 여기광원장치의 개발과 평가)

  • Lim, Hyun-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.113-121
    • /
    • 2009
  • This study aims at designing and evaluating light source devices that can stably generate light with various wavelengths in order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, and 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source, the characteristics of light output and wavelength band were verified. To validate the capability of this device as PDD, the detection of auto-fluorescence using mouse models was performed.

Design and evaluation of light source for photodynamic diagnosis of cancer (광역학적 암진단을 위한 광원장치의 설계 및 평가)

  • Lim, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.73-76
    • /
    • 2007
  • Photodynamic diagnosis(PDD) is a method to diagnose the possibility of cancer, both by the principle that if a photosensitizer is injected into an organic tissue, it is accumulated in the tissue of a malignant tumor selectively after a specific period, and by a comparison of the intensity of the fluorescence of normal tissue with abnormal tissue after investigating the excitation light of a tissue with accumulated photosensitizer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosencitizer, it plays an important role in POD. This study aims at designing and evaluating light source devices that can stably generate light with various kinds of wavelengths In order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-400. The transmission part of the light source was, developed to enhance the efficiency of light transmission. To evaluate this light source device, the characteristics of the light output and wavelength band were verified. To validate the capability of this device as PDD the detection of auto-fluorescence using mouse was performed.

  • PDF

Development of line-scanning two-photon microscopy based on spatial and temporal focusing for tryptophan based auto fluorescence imaging (고속 트립토판 자가형광 이미징을 위한 시공간적 집중 기반의 라인 스캐닝 이광자 현미경 개발)

  • Lee, Jun Ho;Nam, Hyo Seok;Kim, Ki Hean
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.2
    • /
    • pp.41-45
    • /
    • 2013
  • Two-photon microscopy (TPM) is minimally-invasive 3D fluorescence microscopy based on nonlinear excitation, and TPM can visualize cellular structures based on auto-fluorescence. Line-scanning TPM is one of high-speed TPM methods without sacrificing the image resolution by using spatial and temporal focusing. In this paper, we developed line-scanning TPM based on spatial and temporal focusing for auto-fluorescence imaging by exciting the tryptophan. Laser source for this system was an optical parametric oscillator (OPO) and it made near 570 nm femtosecond pulse laser. It had 200fs pulse width and 1.72 nm bandwidth, so that the achievable depth resolution was 2.41um and field of view (FOV) is 10.8um. From the characterization, our system has 3.0 um depth resolution and 12.3 um FOV. We visualized fixed leukocyte cell sample and compared with point scanning system.

Development of Excitation Light Source for Photodynamic Diagnosis of Cancer (광역학적 암진단을 위한 여기 광원장치의 개발)

  • Lim, Hyun-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.49-56
    • /
    • 2007
  • In this paper, the development of excitation light source is proposed for excitation light of the photodynamic therapy of cancer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosensitizer. This study aims at designing and evaluating light source that can stably generate light with various kinds of wavelengths in order to make possible photodynamic diagnosis using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source device by KFDA#s technical reference, the characteristics of the light output and wavelength band were found.

A Review of SERS for Biomaterials Analysis Using Metal Nanoparticles (바이오 물질 분석을 위한 금속 나노입자를 이용한 SERS 분석 연구동향)

  • Jang, Eue-Soon
    • Ceramist
    • /
    • v.22 no.3
    • /
    • pp.281-300
    • /
    • 2019
  • Surface enhanced Raman scattering (SERS) was first discovered in 1974 by an unexpected Raman signal increase from Pyridine adsorbed on rough Ag electrode surfaces by the M. Fleishmann group. M. Moskovits group suggested that this phenomenon could be caused by surface plasmon resonance (SPR), which is a collective oscillation of free electrons at the surface of metal nanostructures by an external light source. After about 40 years, the SERS study has attracted great attention as a biomolecule analysis technology, and more than 2500 new papers and 500 review papers related to SERS topic have been published each year in recently. The advantages of biomaterials analysis using SERS are as follows; ① Molecular level analysis is possible based on unique fingerprint information of biomolecule, ② There is no photo-bleaching effect of the Raman reporters, allowing long-term monitoring of biomaterials compared to fluorescence microscopy, ③ SERS peak bandwidth is approximately 10 to 100 times narrower than fluorescence emission from organic phosphor or quantum dot, resulting in higher analysis accuracy, ④ Single excitation wavelength allows analysis of various biomaterials, ⑤ By utilizing near-infrared (NIR) SERS-activated nanostructures and NIR excitation lasers, auto-fluorescence noise in the visible wavelength range can be avoided from in vivo experiment and light damage in living cells can be minimized compared to visible lasers, ⑥ The weak Raman signal of the water molecule makes it easy to analyze biomaterials in aqueous solutions. For this reason, SERS is attracting attention as a next-generation non-invasive medical diagnostic device as well as substance analysis. In this review, the principles of SERS and various biomaterial analysis principles using SERS analysis will be introduced through recent research papers.

NADH Variation and Process Control with NADH Fluorometer in Full Scale Biological Nutrient Removal Process (실규모의 고도처리공정에서 NADH변화 유형과 이를 활용한 공정제어)

  • Kim, Han-Lae;Cho, Jong-Bok;Cho, Il-Hyoung;Lee, Jin-Woo;Chang, Soon-Woong;Lee, Si-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.6
    • /
    • pp.423-432
    • /
    • 2008
  • In this study, we investigated the possibility of auto control and the proper operating factors in the BNR(Biological Nutrient Removal) process using an NADH(Reduced Nicotinamide Adenine Dinucleotide) fluorometer, which characterized the emitted fluorescence when activated by flashes of UV light at 460 nm. In terms of finding adequate operating parameters, results indicted that nitrification efficiency decreased in the controlled DO while denitrification efficiency decreased in the controlled pH. The above results indicated that controlled operating condition after combination with NADH, DO and pH was resonable. Result obtained from the correlation between NADH and pH showed that variation trend of influent loading was similar to those of NADH and pH, and also the variation cycle was repeated on a daily basis. Consequently, this result showed the increase of BOD loading caused the nitrification efficiency to decrease because air-flow, required for nitrification, was reduced, and so the NADH value was increased. From these results, it is possible to use NADH flourimetry to assess the variation of organic load and nitrification efficiency in the case of small change in influent pH such as in sewage and also to handle and operate the load variation in the auto control system using the NADH fluorometer.

물리정수법에 의한 형광 X선분석과 만장굴석주의 연대측정

  • 택훈
    • Proceedings of the Speleological Society Conference
    • /
    • 1993.07a
    • /
    • pp.163-172
    • /
    • 1993
  • Cheju island is situated at about 90km south of southern most tip of the Korean peninsula. Its shape is an ellips with size of 80$\times$40$km^2$, and it is characterized by a symmetrical form whose peak is Mt. Halla (1950m). Major chemical composition of the rock samples from Manjang gul cave is determined by XRF using the fundamental parameter method consisting of fully auto quantitative analysis, semi quantitative analysis (order estimation) and group quantitative analysis. Judging from chemical composition ($SiO_2 = 53.07Wt% Fe_2 O_3=11.34Wt%, MgO=6.48Wt%, Na_2 O=3.07Wt%, K_2 O=1.05Wt%$), this rocks may belong to non alkalic basalt. K-Ar ages of two rocks samples from the Manjang gul cave are also determined. The discrepancy of K-Ar ages is found. They are 0.03Ma and 0.42Ma, respectively. This paper describes some problems experienced in dating young volcanic rocks and then discusses chemical composition, X-ray fluorescence analysis and the age of the formation of a lava tunnel such as Manjang gul cave in cheju Island.

  • PDF

물리정수법에 의한 형광 X선분석과 만장굴석주의 연대측정

  • 택훈
    • Proceedings of the Speleological Society Conference
    • /
    • 1994.11a
    • /
    • pp.108-109
    • /
    • 1994
  • Cheju island is situated at about 90km south of southern most tip of the Korean peninsula. Its shape is an ellips with size of 80$\times$$40km^2$, and it is characterized by a symmetrical form whose peak is Mt. Halla (1950m). Major chemical composition of the rock samples from Manjang gul cave is determined by XRF using the fundamental parameter method consisting of fully auto quantitative analysis, semi quantitative analysis (order estimation) and group quantitative analysis. Judging from chemical composition ($SiO_2=53.07Wt% Fe_2O_3=11.34Wt%, MgO=6.48Wt%, Na_2O=3.07Wt%, K_2O=1.05Wt%$), this rocks may belong to non alkalic basalt. K-Ar ages of two rocks samples from the Manjang gul cave are also determined. The discrepancy of K-Ar ages is found. They are 0.03Ma and 0.42Ma, respectively. This paper describes some problems experienced in dating young volcanic rocks and then discusses chemical composition, X-ray fluorescence analysis and the age of the formation of a lava tunnel such as Manjang gul cave in cheju Island.

  • PDF

물리정수법에 의한 형과 X 선분석과 만장굴석주의 연대측정

  • ;Hong, Si-Hwan
    • Journal of the Speleological Society of Korea
    • /
    • v.20 no.21
    • /
    • pp.34-43
    • /
    • 1989
  • Cheju island is situated at about 60km south of southern most tip of the Korean peninsula. Its shape is an ellips with size of 80*40$\textrm{km}^2$, and it is characterized by a symmetrical form whose peak is Mt. Halla(1950m). Major chemical composition of the rock samples from Manjang gul cave is determined by XRF using the fundamental parameter method consisting of fully auto quantitative analysis, semi quantitative analysis (order estimation) and group quantitative analysis. Judging from chemical composition (SiO$_2$ = 53.07Wt%, Fe$_2$O$_3$ = 11.34Wt%, MgO=6.48Wt%, Na$_2$O=3.07Wt%, $K_2$O=1.05Wt%), this rocks from the Manjang gul cave are also determined. The discrepancy of K-Ar ages is found. They are 0.03 Ma and 0.42Ma, respectively. This paper describes some problems experienced in dating young volcanic rocks and then discusses chemical composition, X-ray fluorescence analysis and the age of the formation of a lava tunnel such as Manjang gul cave in cheju Island.

  • PDF

Automatic Skin Basal Cell Carcinoma Detection Using Protophorphyrin IX((PpIX) Fluorescence Image (PpIX 형광영상을 이용한 피부 기저세포암 자동검출)

  • Yu, Hong-Yeon;Jun, Do-Young;Kim, Min-Sung;Hong, Sung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.47-54
    • /
    • 2008
  • In this paper, we propose an auto-detection algorithm of basal cell carcinoma(BCC) from the protophorphyrin IX(PpIX) fluorescence image induced by appling the methyl 5-aminolaevulinate(MAL) ointment-induced protophorphyrin IX(PpIX) to the skin tumour area and then shining the wood lamp on the area. The proposed algorithm first generates 3 mask areas-tumor area, suspected tumor area and tumor free area and then applies local watershed algorithm to the turner and the suspected tumor areas to make small watershed regions that include similar luminance value pixels. Next, small watershed regions are merged by hierarchical queue based fast region merging that uses the difference between the average luminance values of adjacent watershed regions as a region merging criterion and finally BCC regions are detected. 50 tissue samples are acquired from the tumour regions of 10 patients with BCC that are extracted by using the proposed algorithm and are performed pathological examination by expert dermatologist. Experiment result shows the rate of tumor detection from BCC lesion using presurgical in vivo of MAL-indeuced PpIX fluorescence has high sensitivity 94.1% and relatively high specificity 82.6%.