• 제목/요약/키워드: Auto-connected transformer

검색결과 9건 처리시간 0.029초

단권변압기 탭 절환 방식에 의한 이중 접속 변형전류형 인버터의 고주파 저감 (Reduction Harmonics in Double Connected Modified Current Source Inverter by Switching Taps on Auto Transformer)

  • 이공희;한우용
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권2호
    • /
    • pp.69-76
    • /
    • 1994
  • An effective method for reducing the harmonics in double connected modified current source inverter[MCSI] by switching taps on auto transformer is presented in this paper. The proposed system operates as like a 24 step MCSI by adding only tap changing auxiliary circuit which consists of several taps and static switching elements to the 12 step multiple inverter, which is double connected three-phase six-step MCSI with an auto transformer. The basic theories of the proposed inverter systems for analyzing the output waveforms are described. And to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and the tap changing control angle of auto transformer are decided by digital simulation and its validity is verified by experiment. Although the construction of the proposed inverter is very simple, it is clarified that the output waveform of the inverter is almost the same as that of the conventional 24 step multiple inverter under the optimum condition.

  • PDF

개방-델타 단권선 변압기를 이용한 새로운 다중 펄스 정류기 시스템 (New Multi-pulse Rectifier Systems Using An Open-Delta Auto-Connected Transformer)

  • 강문식;우병옥
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.278-285
    • /
    • 1999
  • This paper proposes new 12 and 24-pulse rectifier systems using an open-delta auto-connected transformer. This approach employs two static converters to operate it at higher than utility line frequencies and to provide multi-pulse operation. By operating magnetic components at a higher frequency, higher power density can be achieved. A unique feature of the proposed approach is that the magnetic components for the dc-side are also exposed to a higher frequency and these components too are reduced in size. The switching frequency and its harmonic components are absent in the utility input line current. The VA ratings of the transformer and static converter are 0.236/0.292 [pu] and 0.11/0.18 [pu] in 12 and 24-pulse rectifier system, respectively. A finer grade of steel or alternatives can be deployed to increase performance and reduce size further. Analysis, simulations, simulations, design example, and experimental results for a 480[V], 10{kVA] prototype system are presented.

  • PDF

탭 변환 단권변압기 기반 LVRT/HVRT 시험장비의 임피던스 설계 (Impedance design of tap changing auto transformer based LVRT/HVRT test device)

  • 백승혁;김동욱;윤영두;김성민
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.216-224
    • /
    • 2020
  • 본 논문은 계통 연계 기준인 Low Voltage Ride Through(LVRT) 및 High Voltage Ride Through(HVRT) 기능을 평가하기 위한 시험 장비의 임피던스 설계 방법을 제안한다. LVRT/HVRT 시험 장비는 계통 연계 규정에 명시되어 있는 계통 사고 전압을 일정시간 동안 발생시킬 수 있어야 하며 설계 사양에 맞게 사고전류의 크기를 제한해야 한다. 본 논문에서는 LVRT/HVRT 동작 시 탭 변환 단권변압기 시험 장비의 등가 모델을 기반으로 계통 연계 규정을 만족하기 위한 단권변압기의 임피던스를 설계한다. 제안하는 설계 방법을 이용하여 LVRT/HVRT 시험 시 요구되는 다양한 사고전압을 출력할 수 있는 시험장비의 설계를 위한 탭 간의 임피던스 설계 과정을 설명한다. 제안하는 설계 방법의 타당성을 검증하기 위하여, 10MVA급 LVRT/HVRT 시험 장비의 설계 과정을 설명하고 시뮬레이션을 통하여 확인하였다.

이중 여자 플라이백 기반 고압 SMPS 설계 (High Voltage SMPS Design based on Dual-Excitation Flyback Converter)

  • 양희원;김승애;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제20권2호
    • /
    • pp.115-124
    • /
    • 2017
  • This paper aims to develop an SMPS topology for handling a high range of input voltages based on a DC-DC flyback converter circuit. For this purpose, 2 capacitors of the same specifications were serially connected on the input terminal side, with a flyback converter of the same circuit configuration serially connected to each of them, so as to achieve high input voltage and an effect of dividing input voltage. The serially connected flyback converters have the transformer turn ratio of 1:1, so that each coil is used for the winding of a single transformer, which is a characteristic of doubly-fed configuration and enables the correction of input capacitor voltage imbalance. In addition, a pulse transformer was designed and fabricated in a way that can achieve the isolation and noise robustness of the PWM output signal of the PWM controller that applies gate voltage to individual flyback converter switches. PSIM simulation was carried out to verify such a structure and confirm its feasibility, and a 100W class stack was fabricated and used to verify the feasibility of the proposed high voltage SMPS topology.

A Zigzag Connected Auto-Transformer Based 24-Pulse AC-DC Converter

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.235-242
    • /
    • 2008
  • In this paper, a 24-pulse AC-DC converter is designed, modeled, simulated, and developed to feed non-isolated varying loads. The proposed AC-DC converter configuration consists of an auto-transformer based on zigzag connection to overcome current harmonic problems in AC mains. It improves power quality at AC mains and it meets IEEE-519 standard requirements at varying loads. A set of power quality indices on input AC mains and on DC buses for a load fed from 6-pulse and 12-pulse AC-DC converters is also given to compare their performance. It is observed that input current total harmonic distortion(THD) of less than 8% is possible with the proposed topology of AC-DC converter at varying loads.

3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과 (Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구 (A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System)

  • 김현동;조규정;허승훈;김철환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

정류기 부하와 무정전전원장치 사이에 발생되는 Current Harmonic 저감 (Reduction of Current Harmonic Occurred form between Uninterruptible Powers Supply and Rectifier Load)

  • 곽철훈;반한식;최규하;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.41-44
    • /
    • 1999
  • The main purpose of the UPS is to supply independent and stable power to connected equipment. In installing and operating the UPS system, songle module, three phase UPS in more benefit than multi module, songle phase UPS in the point of volume and cost. However, when supplying Rectifier with output power form three phase UPS, by connecting auto-transformer, occurred harmonic and ripple current makes output filter damaged and leads to nonlinear current coasted by unbalance load. Therefor, in this paper the aim of concentring compound-wound transformer and harmonic filter is supplying liner current by reducing harmonic and ripple current and improving unbalance in voltage and distortion in current wave.

  • PDF

AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구 (A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method)

  • 김민석;최승혁;이종우
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.