• 제목/요약/키워드: Attenuation Index

검색결과 102건 처리시간 0.023초

Association Between Pelvic Bone Computed Tomography-Derived Body Composition and Patient Outcomes in Older Adults With Proximal Femur Fracture

  • Tae Ran Ahn;Young Cheol Yoon;Hyun Su Kim;Kyunga Kim;Ji Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제24권5호
    • /
    • pp.434-443
    • /
    • 2023
  • Objective: To investigate the association between pelvic bone computed tomography (CT)-derived body composition and patient outcomes in older adult patients who underwent surgery for proximal femur fractures. Materials and Methods: We retrospectively identified consecutive patients aged ≥ 65 years who underwent pelvic bone CT and subsequent surgery for proximal femur fractures between July 2018 and September 2021. Eight CT metrics were calculated from the cross-sectional area and attenuation of the subcutaneous fat and muscle, including the thigh subcutaneous fat (TSF) index, TSF attenuation, thigh muscle (TM) index, TM attenuation, gluteus maximus (GM) index, GM attenuation, gluteus medius and minimus (Gmm) index, and Gmm attenuation. The patients were dichotomized using the median value of each metric. Multivariable Cox regression and logistic regression models were used to determine the association between CT metrics with overall survival (OS) and postsurgical intensive care unit (ICU) admission, respectively. Results: A total of 372 patients (median age, 80.5 years; interquartile range, 76.0-85.0 years; 285 females) were included. TSF attenuation above the median (adjusted hazard ratio [HR], 2.39; 95% confidence interval [CI], 1.41-4.05), GM index below the median (adjusted HR, 2.63; 95% CI, 1.33-5.26), and Gmm index below the median (adjusted HR, 2.33; 95% CI, 1.12-4.55) were independently associated with shorter OS. TSF index (adjusted odds ratio [OR], 6.67; 95% CI, 3.13-14.29), GM index (adjusted OR, 3.45; 95% CI, 1.49-7.69), GM attenuation (adjusted OR, 2.33; 95% CI, 1.02-5.56), Gmm index (adjusted OR, 2.70; 95% CI, 1.22-5.88), and Gmm attenuation (adjusted OR, 2.22; 95% CI, 1.01-5.00) below the median were independently associated with ICU admission. Conclusion: In older adult patients who underwent surgery for proximal femur fracture, low muscle indices of the GM and gluteus medius/minimus obtained from their cross-sectional areas on preoperative pelvic bone CT were significant prognostic markers for predicting high mortality and postsurgical ICU admission.

Influence of time-varying attenuation effect of damage index on seismic fragility of bridge

  • Yan, Jialei;Liang, Yan;Zhao, Boyang;Qian, Weixin;Chen, Huai
    • Earthquakes and Structures
    • /
    • 제19권4호
    • /
    • pp.287-301
    • /
    • 2020
  • Fragility as one of the most effective methods to evaluate seismic performance, which is greatly affected by damage index. Taking a multi span continuous rigid frame offshore bridge as an example. Based on fragility and reliability theory, considering coupling effect of time-varying durability damage of materials and time-varying attenuation effect of damage index to analyze seismic performance of offshore bridges. Results show that IDA curve considering time-varying damage index is obviously below that without considering; area enclosed by IDA of 1# pier and X-axis under No.1 earthquake considering this effect is 96% of that without considering. Area enclosed by damage index of 1# pier and X-axis under serious damage with considering time-varying damage index is 90% of that without considering in service period. Time-varying damage index has a greater impact on short pier when ground motion intensity is small, while it has a great impact on high pier when the intensity is large. The area enclosed by fragility of bridge system and X-axis under complete destruction considering time-varying damage index is 165% of that without considering when reach designed service life. Therefore, time-varying attenuation effect of damage index has a great impact on seismic performance of bridge in service period.

초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석 (Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images)

  • 천혜리;장현철
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.927-934
    • /
    • 2022
  • 본 연구는 간 초음파 영상을 활용하여 정량적인 측정 분석을 통해 조직 내 감쇠 지수, 조직 내 산란 분포지수 값 분석과 함께 초음파 영상 소견 간 일치도를 알아보고자 하였다. 2022년 8월부터 2022년 10월까지 지방간이 의심되어 간 초음파 검사 처방을 받은 45명의 환자를 대상으로 간 초음파 검사를 시행하였다. 연구결과, 초음파 영상 소견과 조직 내 감쇠 지수 간 일치도 분석 결과 Kappa 값이 0.82(p<0.05)로 두 검사 방법 간 매우 높은 일치도를 보였다. 또한, 초음파 영상 소견과 조직 내 산란 분포 지수 간 일치도 분석 결과에서도 Kappa 값이 0.642(p<0.05)로 두 검사 방법 간 높은 일치도를 보였다. 지방간 예측 시 간 초음파 소견 및 정량적인 초음파 검사 기법인 조직 내 감쇠 지수, 조직 내 산란 분포 지수를 활용한다면 지방간 환자의 진행 정도를 판단할 때 도움이 될 수 있을 것으로 생각된다.

In-line Variable Attenuator Based on the Evanescent Wave Coupling Between a Side-polished Single-mode Fiber and an Index Matched Dielectric Plate

  • Kim, Kwang-Taek;Kim, Hyo-Kyeom
    • Journal of the Optical Society of Korea
    • /
    • 제8권1호
    • /
    • pp.17-20
    • /
    • 2004
  • An in-line variable attenuator has been proposed and demonstrated exploiting a side-polished single-mode (SM) fiber evanescently coupled with an index matched dielectric plate. The attenuation can be controlled by fine mechanical sliding of the index matched dielectric plate. We have achieved 49 ㏈ dynamic range and very low excess loss of 0.2 ㏈ at 1550 nm wavelength. The measured polarization dependent losses (PDL) were 0.1, 0.2, and 0.4 ㏈ at 10, 20, and 30 ㏈ attenuation, respectively. Wavelength sensitivity was measured to be -0.017/nm ㏈ at 20 ㏈ attenuation.

Depth estimation for surface-breaking cracks in steel-fiber reinforced concrete using ultrasonic surface waves

  • Ahmet S. Kirlangic;Zafer Iscan
    • Structural Monitoring and Maintenance
    • /
    • 제9권4호
    • /
    • pp.373-388
    • /
    • 2022
  • A USW based diagnostic procedure is presented for estimating the depth of surface-breaking cracks. The diagnosis is demonstrated on seven lab-scale SFRC beam specimens, which are subjected to the CMOD controlled three-point bending test to create real bending cracks. Then, the recorded multiple ultrasonic signals are examined with the signal processing techniques, including wavelet transform and two-dimensional Fourier transform, to investigate the relationships between the crack depth and two diagnostic indices, namely the attenuation coefficient and dispersion index (DI). Finally, the reliabilities of these indices for depth estimation are verified with the visually measured crack depths as well as the crack features obtained with a digital image processing algorithm. It is found that the DI outperforms the attenuation coefficient in depth estimation, where this index displays good agreement with the visual inspection for 86% of the inspected specimens.

당뇨화 다밀도 안창의 충격특성 (Impact Characteristics of Multi-Density Insoles for DM Shoes)

  • 금영광;정임숙;강성재;김영길;김명웅;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.31-36
    • /
    • 2003
  • 본 논문에서는 일정한 충격하중을 제공하여 충격특성을 정량적으로 측정할 수 있는 시스템을 개발하고 당뇨화 안창의 소재에 대한 감쇠지수, 중앙주파수, 반발계수 등을 통하여 6종류의 당뇨화 소재와 3종류의 다밀도 당뇨화 안창의 충격특성을 측정하였다. Podian, Plastazote black, Plastazote white, Flexible PU foam, Podialene 200 blue, Podia flex 소재 중에서 감쇠지수와 반발계수는 Podian이 우수하였으며, Flexible PU foam 소재의 중앙주파수가 가장 작음을 알 수 있었다. 3종의 다밀도 안창인 AP 안창, OS 안창, PW 안창을 각각 세 부위로 나누어 안창의 종류와 부위별 충격특성을 비교한 결과 발뒤꿈치 부분이 충격완화 효과가 가장 우수함을 확인할 수 있었다. 반발계수와 중앙주파수에서는 OS 안창이 AP 안창보다 충격완화 효과가 우수함을 보였으나, 감쇠지수는 서로 유사한 견과를 보였다. PW 안창은 두 겹의 폴리우레탄이 전체에 분포되어 있으므로 부위별로 유사한 충격흡수정도를 나타내었다.

Underwater Optical Image Data Transmission in the Presence of Turbulence and Attenuation

  • Ramavath Prasad Naik;Maaz Salman;Wan-Young Chung
    • 융합신호처리학회논문지
    • /
    • 제24권1호
    • /
    • pp.1-14
    • /
    • 2023
  • Underwater images carry information that is useful in the fields of aquaculture, underwater military security, navigation, transportation, and so on. In this research, we transmitted an underwater image through various underwater mediums in the presence of underwater turbulence and beam attenuation effects using a high-speed visible optical carrier signal. The optical beam undergoes scintillation because of the turbulence and attenuation effects; therefore, distorted images were observed at the receiver end. To understand the behavior of the communication media, we obtained the bit error rate (BER) performance of the system with respect to the average signal-to-noise ratio (SNR). Also, the structural similarity index (SSI) and peak SNR (PSNR) metrics of the received image were evaluated. Based on the received images, we employed suitable nonlinear filters to recover the distorted images and enhance them further. The BER, SSI, and PSNR metrics of the specific nonlinear filters were also evaluated and compared with the unfiltered metrics. These metrics were evaluated using the on-off keying and binary phase-shift keying modulation techniques for the 50-m and 100-m links for beam attenuation resulting from pure seawater, clear ocean water, and coastal ocean water mediums.

유류 오염물질에 대한 불포화대 자연 저감능 등급화 기법 개발 (A New Evaluation Model for Natural Attenuation Capacity of a Vadose Zone Against Petroleum Contaminants)

  • 우희수;안성남;김기범;박새롬;오성직;김상현;정재식;이승학
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권spc호
    • /
    • pp.92-98
    • /
    • 2022
  • Although various methods have been proposed to assess groundwater vulnerability, most of the models merely consider the mobility of contaminants (i.e., intrinsic vulnerability), and the attenuation capacity of vadose zone is often neglected. This study proposed an evaluation model for the attenuation capacity of vadose zone to supplement the limitations of the existing index method models for assessing groundwater vulnerability. The evaluation equation for quantifying the attenuation capacity was developed from the combined linear regression and weighted scaling methods based on the lab-scale experiments using various vadose zone soils having different physical and biogeochemical properties. The proposed semi-quantifying model is expected to effectively assess the attenuation capacity of vadose zone by identifying the main influencing factors as input parameters together with proper weights derived from the coefficients of the regression results. The subsequent scoring and grading system has great versatility while securing the objectivity by effectively incorporating the experimental results.

Fabrication and Characterization of Sol-Gel Ternary Titanium Silicate Waveguides

  • Junmo Koo;Han, Sang-Soo;Bae, Byeong-Soo
    • The Korean Journal of Ceramics
    • /
    • 제2권2호
    • /
    • pp.89-94
    • /
    • 1996
  • Aluminum and zinc titanium silicate sol-gel films were fabricated for application of waveguide and the effect of additions of ZnO and $Al_2O_3$ to binary titanium silicate films was investigated. During firing, the films are densified as they shrunk and their refractive index increases in the range of 1.58-1.83 depending on the film composition. The attenuation of the waveguides is not sensitive to changes in composition except for zinc titanium silicate waveguides which have substantially higher attenuation. However, the increase in the attenuation with aging of the waveguides depend upon the composition of waveuides. The addition $Al_2O_3$ or the reduced $SiO_2$ content in the composition appears to slow the deterioration of the waveguides due to the formation of more stable bonds and increased acidity on the film surface. Also, the wavelength dependence of the attenuation of the waveguides varies with composition. The attenuation of the waveguides except for the $65SiO_2{\cdot}35TiO_2$ composition are not Rayleigh scatter limited, suggesting the absorption loss of the waveguides due to the effects of residual carbon and structural defects in the films.

  • PDF

투명한 PMMA 로 된 플라스틱 섬유의 광학적 성질 (Optical Properties of Plastic Fiber Made from a Transparent Polymethylmethacrylate)

  • 채희주
    • 대한화학회지
    • /
    • 제33권4호
    • /
    • pp.431-435
    • /
    • 1989
  • 완전히 불순물을 제거한 투명한 polymethylmethacrylate(PMMA)의 prerod를 제조하여 연속 열연신하여 얻은 플라스틱 섬유의 연신온도($T_d$)에 따른 굴절율, 굴절율분포, 복굴절율 및 전송손실율을 측정하였다. $T_d$가 높을수록 다소 낮은 굴절율을 보였으나, 섬유의 중심에서 주변으로 감에 따른 굴절율분포는 오히려 낮은 $T_d$에서가 현저했고, 높은 $T_d$에서는 주변에서만 급격한 굴절율의 강하를 보였다. 또한 $T_d$가 220$^{\circ}C$ 미만에서는 복굴절을 ${\Delta}$n = $5{sim}6{\times}10^{-4}$을 보이고 그 보다 높은 온도의 $T_d$에서는 이러한 현상이 나타나지 않았다. Attenuation은 높은 $T_d$일수록 낮은 값을 보였다.

  • PDF