• Title/Summary/Keyword: Attenuation Index

Search Result 102, Processing Time 0.024 seconds

Association Between Pelvic Bone Computed Tomography-Derived Body Composition and Patient Outcomes in Older Adults With Proximal Femur Fracture

  • Tae Ran Ahn;Young Cheol Yoon;Hyun Su Kim;Kyunga Kim;Ji Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.5
    • /
    • pp.434-443
    • /
    • 2023
  • Objective: To investigate the association between pelvic bone computed tomography (CT)-derived body composition and patient outcomes in older adult patients who underwent surgery for proximal femur fractures. Materials and Methods: We retrospectively identified consecutive patients aged ≥ 65 years who underwent pelvic bone CT and subsequent surgery for proximal femur fractures between July 2018 and September 2021. Eight CT metrics were calculated from the cross-sectional area and attenuation of the subcutaneous fat and muscle, including the thigh subcutaneous fat (TSF) index, TSF attenuation, thigh muscle (TM) index, TM attenuation, gluteus maximus (GM) index, GM attenuation, gluteus medius and minimus (Gmm) index, and Gmm attenuation. The patients were dichotomized using the median value of each metric. Multivariable Cox regression and logistic regression models were used to determine the association between CT metrics with overall survival (OS) and postsurgical intensive care unit (ICU) admission, respectively. Results: A total of 372 patients (median age, 80.5 years; interquartile range, 76.0-85.0 years; 285 females) were included. TSF attenuation above the median (adjusted hazard ratio [HR], 2.39; 95% confidence interval [CI], 1.41-4.05), GM index below the median (adjusted HR, 2.63; 95% CI, 1.33-5.26), and Gmm index below the median (adjusted HR, 2.33; 95% CI, 1.12-4.55) were independently associated with shorter OS. TSF index (adjusted odds ratio [OR], 6.67; 95% CI, 3.13-14.29), GM index (adjusted OR, 3.45; 95% CI, 1.49-7.69), GM attenuation (adjusted OR, 2.33; 95% CI, 1.02-5.56), Gmm index (adjusted OR, 2.70; 95% CI, 1.22-5.88), and Gmm attenuation (adjusted OR, 2.22; 95% CI, 1.01-5.00) below the median were independently associated with ICU admission. Conclusion: In older adult patients who underwent surgery for proximal femur fracture, low muscle indices of the GM and gluteus medius/minimus obtained from their cross-sectional areas on preoperative pelvic bone CT were significant prognostic markers for predicting high mortality and postsurgical ICU admission.

Influence of time-varying attenuation effect of damage index on seismic fragility of bridge

  • Yan, Jialei;Liang, Yan;Zhao, Boyang;Qian, Weixin;Chen, Huai
    • Earthquakes and Structures
    • /
    • v.19 no.4
    • /
    • pp.287-301
    • /
    • 2020
  • Fragility as one of the most effective methods to evaluate seismic performance, which is greatly affected by damage index. Taking a multi span continuous rigid frame offshore bridge as an example. Based on fragility and reliability theory, considering coupling effect of time-varying durability damage of materials and time-varying attenuation effect of damage index to analyze seismic performance of offshore bridges. Results show that IDA curve considering time-varying damage index is obviously below that without considering; area enclosed by IDA of 1# pier and X-axis under No.1 earthquake considering this effect is 96% of that without considering. Area enclosed by damage index of 1# pier and X-axis under serious damage with considering time-varying damage index is 90% of that without considering in service period. Time-varying damage index has a greater impact on short pier when ground motion intensity is small, while it has a great impact on high pier when the intensity is large. The area enclosed by fragility of bridge system and X-axis under complete destruction considering time-varying damage index is 165% of that without considering when reach designed service life. Therefore, time-varying attenuation effect of damage index has a great impact on seismic performance of bridge in service period.

Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images (초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석)

  • Hye-Ri, Chun;Hyon-Chol, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2022
  • This study attempted to find out the degree of agreement between ultrasound image findings along with analysis of attenuation index and scatter distribution index values within tissues through quantitative measurement analysis using liver ultrasound images. From August 2022 to October 2022, liver ultrasound was performed on 45 patients who were suspected of having fatty liver and who received a prescription for liver ultrasound. As a result of the study, as a result of analyzing the agreement between the ultrasound image findings and the tissue attenuation index, the Kappa value was 0.82 (p<0.05), showing a very high agreement between the two examination methods. In addition, as a result of the agreement analysis between the ultrasound image findings and the scatter distribution index in the tissue, the Kappa value was 0.642 (p<0.05), showing high agreement between the two examination methods. At the time of fat liver prediction, the use of liver ultrasound findings and quantitative ultrasonography techniques, such as intra-tissue attenuation index and intra-tissue scatter distribution index, may be helpful in determining the degree of progression of fatty liver patients.

In-line Variable Attenuator Based on the Evanescent Wave Coupling Between a Side-polished Single-mode Fiber and an Index Matched Dielectric Plate

  • Kim, Kwang-Taek;Kim, Hyo-Kyeom
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.17-20
    • /
    • 2004
  • An in-line variable attenuator has been proposed and demonstrated exploiting a side-polished single-mode (SM) fiber evanescently coupled with an index matched dielectric plate. The attenuation can be controlled by fine mechanical sliding of the index matched dielectric plate. We have achieved 49 ㏈ dynamic range and very low excess loss of 0.2 ㏈ at 1550 nm wavelength. The measured polarization dependent losses (PDL) were 0.1, 0.2, and 0.4 ㏈ at 10, 20, and 30 ㏈ attenuation, respectively. Wavelength sensitivity was measured to be -0.017/nm ㏈ at 20 ㏈ attenuation.

Depth estimation for surface-breaking cracks in steel-fiber reinforced concrete using ultrasonic surface waves

  • Ahmet S. Kirlangic;Zafer Iscan
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.4
    • /
    • pp.373-388
    • /
    • 2022
  • A USW based diagnostic procedure is presented for estimating the depth of surface-breaking cracks. The diagnosis is demonstrated on seven lab-scale SFRC beam specimens, which are subjected to the CMOD controlled three-point bending test to create real bending cracks. Then, the recorded multiple ultrasonic signals are examined with the signal processing techniques, including wavelet transform and two-dimensional Fourier transform, to investigate the relationships between the crack depth and two diagnostic indices, namely the attenuation coefficient and dispersion index (DI). Finally, the reliabilities of these indices for depth estimation are verified with the visually measured crack depths as well as the crack features obtained with a digital image processing algorithm. It is found that the DI outperforms the attenuation coefficient in depth estimation, where this index displays good agreement with the visual inspection for 86% of the inspected specimens.

Impact Characteristics of Multi-Density Insoles for DM Shoes (당뇨화 다밀도 안창의 충격특성)

  • 금영광;정임숙;강성재;김영길;김명웅;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Impact characteristics of six DM(Diabetes Mellitus) shoe insole materials (Podian, Plastazote black, Plastazote white, Flexible PU foam, Podialene 200 blue and Podia flex) and three multi-density insoles (AP, OS and PW insoles) were determined in the present study, using a self-designed impact measurement system. The coefficient of restitution, the median frequency and the attenuation index were calculated for each material, based on impact forces and linear accelerations. Podian revealed the superiority in the coefficient of restitution and the attenuation index. The median frequency of the Flexible PU foam was the smallest. Results also showed that the heel region was the most impact-attenuated among other areas in the insole. OS insole showed the better characteristics in the coefficient of restitution and the median frequency. but there was no significant difference in the attenuation index. Similar impact characteristics were found in all areas in PW insole. since it was basically of the same dual-density polyurethane.

Underwater Optical Image Data Transmission in the Presence of Turbulence and Attenuation

  • Ramavath Prasad Naik;Maaz Salman;Wan-Young Chung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Underwater images carry information that is useful in the fields of aquaculture, underwater military security, navigation, transportation, and so on. In this research, we transmitted an underwater image through various underwater mediums in the presence of underwater turbulence and beam attenuation effects using a high-speed visible optical carrier signal. The optical beam undergoes scintillation because of the turbulence and attenuation effects; therefore, distorted images were observed at the receiver end. To understand the behavior of the communication media, we obtained the bit error rate (BER) performance of the system with respect to the average signal-to-noise ratio (SNR). Also, the structural similarity index (SSI) and peak SNR (PSNR) metrics of the received image were evaluated. Based on the received images, we employed suitable nonlinear filters to recover the distorted images and enhance them further. The BER, SSI, and PSNR metrics of the specific nonlinear filters were also evaluated and compared with the unfiltered metrics. These metrics were evaluated using the on-off keying and binary phase-shift keying modulation techniques for the 50-m and 100-m links for beam attenuation resulting from pure seawater, clear ocean water, and coastal ocean water mediums.

A New Evaluation Model for Natural Attenuation Capacity of a Vadose Zone Against Petroleum Contaminants (유류 오염물질에 대한 불포화대 자연 저감능 등급화 기법 개발)

  • Woo, Heesoo;An, Seongnam;Kim, Kibeum;Park, Saerom;Oh, Sungjik;Kim, Sang Hyun;Chung, Jaeshik;Lee, Seunghak
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.spc
    • /
    • pp.92-98
    • /
    • 2022
  • Although various methods have been proposed to assess groundwater vulnerability, most of the models merely consider the mobility of contaminants (i.e., intrinsic vulnerability), and the attenuation capacity of vadose zone is often neglected. This study proposed an evaluation model for the attenuation capacity of vadose zone to supplement the limitations of the existing index method models for assessing groundwater vulnerability. The evaluation equation for quantifying the attenuation capacity was developed from the combined linear regression and weighted scaling methods based on the lab-scale experiments using various vadose zone soils having different physical and biogeochemical properties. The proposed semi-quantifying model is expected to effectively assess the attenuation capacity of vadose zone by identifying the main influencing factors as input parameters together with proper weights derived from the coefficients of the regression results. The subsequent scoring and grading system has great versatility while securing the objectivity by effectively incorporating the experimental results.

Fabrication and Characterization of Sol-Gel Ternary Titanium Silicate Waveguides

  • Junmo Koo;Han, Sang-Soo;Bae, Byeong-Soo
    • The Korean Journal of Ceramics
    • /
    • v.2 no.2
    • /
    • pp.89-94
    • /
    • 1996
  • Aluminum and zinc titanium silicate sol-gel films were fabricated for application of waveguide and the effect of additions of ZnO and $Al_2O_3$ to binary titanium silicate films was investigated. During firing, the films are densified as they shrunk and their refractive index increases in the range of 1.58-1.83 depending on the film composition. The attenuation of the waveguides is not sensitive to changes in composition except for zinc titanium silicate waveguides which have substantially higher attenuation. However, the increase in the attenuation with aging of the waveguides depend upon the composition of waveuides. The addition $Al_2O_3$ or the reduced $SiO_2$ content in the composition appears to slow the deterioration of the waveguides due to the formation of more stable bonds and increased acidity on the film surface. Also, the wavelength dependence of the attenuation of the waveguides varies with composition. The attenuation of the waveguides except for the $65SiO_2{\cdot}35TiO_2$ composition are not Rayleigh scatter limited, suggesting the absorption loss of the waveguides due to the effects of residual carbon and structural defects in the films.

  • PDF

Optical Properties of Plastic Fiber Made from a Transparent Polymethylmethacrylate (투명한 PMMA 로 된 플라스틱 섬유의 광학적 성질)

  • Hee-Ju Chae;Yasuhiro Koike
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.431-435
    • /
    • 1989
  • The refractive index, refractive-index distribution, birefringence, and the attenuation of the plastic fiber prepared from the transparent PMMA prerod were measured in accordance with continuous heat drawing temperature($T_d$). The refractive indices were decreased with $T_d$ elevation but the refractive-index distribution from the center of fiber to periphery was higher at lower $T_d$. The steep decrease of gradient index was only at the periphery of higher $T_d$. Birefringence was observed only below $220^{\circ}C$ and ranged $5{\times}10^{-4}$ to $6{\times}10^{-4}$. No birefringence was observed above $220^{\circ}C$. An elevation of $T_d$ brought about a monotonous decrease in the attenuation of the fiber.

  • PDF