• Title/Summary/Keyword: Atomic emission

Search Result 646, Processing Time 0.04 seconds

A Study on Cation Extraction and Impurity Separation in Slag (슬래그 내 양이온 추출 및 불순물 분리 연구)

  • Lee, Ye Hwan;Kang, Hyerin;Jang, Younghee;Lee, Si-Jin;Kim, Sung Su
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.311-315
    • /
    • 2019
  • The cation extraction and impurity separation were studied in order to investigate the recyclability of a slag produced from the steel refinery industry. Two types of slag (Slag-A, B) were collected and characterized in this study. The initial characterization by X-ray diffraction (XRD) and X-ray fluorescence (XRF) confirmed the existence of various kinds of ions in the slag such as Ca2+ (30 ~ 40%), Fe3+ (20 ~ 30%), Si4+ (15%), Al3+ (10%), Mn2+ (7%), and Mg2+ (3 ~ 5%). Inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis on the extracted slag using 2 M HCl as a solvent indicated that a higher concentration of Ca2+ was extracted as the S/L ratio was increased. The Ca2+ extraction concentration were found to be 8,940 mg L-1 (Slag-A) and 10,690 (Slag-B) mg L-1 when the S/L ratio for Ca2+ extraction was 0.1. However, the extract was strongly acidic ( < pH 1) at 0.1 S/L. Also the other ions (impurities) were extracted simultaneously in addition to Ca2+. To increase the purity of Ca2+ in order to transform the slag to a high value resource, a pH-swing was conducted. The impurities tended to precipitate at higher rate as the pH was increased. Notably, the Ca2+ rapidly precipitated above a certain pH and at a pH of 10.5, while the selectivity of Ca2+ was over 99%. It is expected that the aqueous solution in which high contents of Ca2+ was selectively dissolved in this study would be suitable for the carbonation process for reducing CO2 and for the production of calcium carbonate.

FILLER LEACHING FROM NANOFILLER-CONTAINED COMPOSITE RESIN IN VARIOUS MEDIA (수종의 저장 용액에서 나노필러를 함유한 복합레진의 필러의 용출량에 관한 연구)

  • Yang, Kyu-Ho;Heo, Su-Kyung;Choi, Nam-Ki;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.62-70
    • /
    • 2009
  • The objective of this study was to measure the leaching of filler (Si, Ba) from nanofiller-contained composites (Palfique Estelite $sigma^{{R}}$ (Tokuyama Dental Corp., Tokyo, Japan), $Z-350^{{R}}$ (3M ESPE, USA), Ceram X duo $E3^{{R}}$, $D3^{{R}}$ (Dentsply, Konstanz, Germany)) under different conditions. The samples used for the study of leachable components were made by insertion of the material into a circular mold, 10 mm in diameter and 3.0 mm high. Each specimen was placed in a disposable polystyrene vial containing 5 mL of distilled water, artificial saliva or 0.1N NaOH and kept in an oven at $37^{\circ}C$. ; water and artificial saliva - 150 days, 0.1N NaOH - 15days. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) was used to determine the amount of Si and Ba in the test solutions. 1. Filler leaching was significantly great in 0.1N NaOH among all samples(p<.0.001). 2. When samples were stored in the distilled water, Estelite showed the lowest amount of Si leaching. When samples were stored in the artificial saliva, Z-350 showed the lowest amount of Si leaching. 3. There were significant differences in filler leaching between 3 storage medias and composite resins(p<.0.001). 4. Si and Ba leaching occurred in greater proportion when samples were stored in the artificial saliva than distilled water. 5. There were significant interactions in monthly filler leaching between leaching in artificial saliva and in distilled water, as well as the interaction between storage medium and filler(p<.0001). These results indicate that a continuous filler leaching of nanofiller-contained composite resins was in storing aqueous solutions under over time.

  • PDF

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

Dietary Intakes, Serum Concentrations, and Urinary Excretions of Fe, Zn, Cu, Mn, Se, Mo, and Cr of Korean Young Adult Women (일부 젊은 성인여자의 Fe, Zn, Cu, Mn, Se, Mo 및 Cr의 식사섭취, 혈청농도 및 소변배설)

  • Kim, Kyune-Hee;Lim, Hyeon-Sook
    • Journal of Nutrition and Health
    • /
    • v.39 no.8
    • /
    • pp.762-772
    • /
    • 2006
  • This study was conducted to investigate dietary intakes, serum concentrations, and urinary excretions of iron (Fe), zinc (Zn), copper (Cu), manganese (Mn), selenium (Se), molybdenum (Mo), and chromium (Cr) of Korean young adult women. A total of 19 apparently healthy young adult women aged in their twenties or thirties participated voluntarily. One-tenth of all foods they consumed for 3 consecutive days were collected, all urine excreted for the same 3 days was gathered, and fasting venous blood was withdrawn for the trace mineral analyses. Of the food, blood, and urine samples, the contents of Zn, Cu, Mn, Se, Mo, and Cr were analyzed by inductively coupled plasma-mass spectroscopy (ICP-MS) and that of Fe by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) after wet digestion. The intake of Fe, $6.94{\pm}2.18mg$, did not meet the estimated average requirement (EAR) for Korean women aged 20-29 years old. On the contrary, the intakes of Zn ($9.35{\pm}4.95mg$), Cu ($1.18{\pm}0.26mg$), and Mn ($3.69{\pm}0.69mg$) were sufficient for each respective EAR. However, some of the subjects did not take the EAR for Zn. The Se intake, $41.93{\pm}9.28{\mu}g$, however, was almost similar to the EAR for Se. Although there are no references for Mo and Cr, the intakes of these minerals ($134.0{\pm}49.1\;and\;136.5{\pm}147.9{\mu}g$, respectively) seemed to be excessively sufficient. Serum Fe concentration, $88.7{\pm}36.8{\mu}g/dL$, seemed to be a little bit lower than its reference median but within its normal range. Approximately one-fourth of the subjects were in anemic determined by Hb and Hct and below the deficiency serum level of Fe, $60{\mu}g/dL$. In addition, serum Se concentration, $3.73{\pm}0.60{\mu}g/dL$, was also below its reference median and normal range. However, serum concentrations of Zn ($99.6{\pm}30.6{\mu}g/dL$) and Mo ($0.25{\pm}0.10{\mu}g/dL$) were fairly good compared to each reference median. The status of Cu could be determined as good although its serum concentration ($91.6{\pm}14.6{\mu}g/dL$) was slightly below its reference median. Since there are no decisive reference values, it was not easy to evaluate serum concentrations of Mn ($0.93{\pm}0.85{\mu}g/dL$) and Cr ($8.60{\pm}7.25{\mu}g/dL$). But Mn and Cr status seemed to be adequate. Urinary Fe excretion, $4.48{\pm}1.98{\mu}g/dL$, was pretty much lower than its reference and that of Se, $2.45{\pm}1.17{\mu}g/dL$, was also lower than its average. On the other hand, those of Zn ($42.95{\pm}20.47{\mu}g/dL$) and Cu ($5.68{\pm}1.50{\mu}g/dL$) were flirty good. In case of Mn, urinary excretion, $0.31{\pm}0.09{\mu}g/dL$, was much greater than its reference. Urinary excretions of Mo ($7.48{\pm}2.95{\mu}g/dL$) and Cr ($1.37{\pm}0.41{\mu}g/dL$) were very higher compared to each reference. The results of this study revealed that Korean young adult women were considerably poor in Fe status, a bit inadequate in Se status, partly inadequate in Zn status, and flirty good in Cu, Mn, Mo and Cr status. However, there was a problem of excessive intakes of Mo and Cr. It, therefore, should be concerned to increase the intakes of Fe, Se and Zn but to decrease Mo and Cr consumption for young adult women.

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

Hydrothermal Alteration around the Tofua Arc (TA) 25 Seamounts in Tonga Arc (통가열도 TA 25 해저산의 열수변질)

  • Cho, Hyen Goo;Kim, Dong-Ho;Koo, Hyo Jin;Um, In Kwon;Choi, Hunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.169-181
    • /
    • 2014
  • Korea government has consistently investigated the development of economic mineral deposits in the Tofua volcanic arc, Tonga since 2008 for the secure of sea floor mineral resources. We studied the composition and distribution of minerals formed by hydrothermal activity around TA 25 seamounts of the Tofua volcanic arc, Lau Basin, Tonga, using X-ray diffraction analysis, scanning electron microscopy, X-ray fluorescence spectrometry, and inductively coupled plasma atomic emission spectrometry. We used 7 core samples and 9 surface sediment samples. Barite, sphalerite, and clinoclase are present in the most volcanic vent area. Gypsum, smectite, and kaolin mineral are distributed in vent A area, chalcopyrite, pyrite, smectite, and kaolin mineral are in vent B and C area, and gypsum, chalcopyrite, pyrite, and goethite are in vent D area. From the study of clay fraction, smectite and few kaolinite are detected in the most studied area except inner part of caldera, which suggest that argillic alteration are dominant in the volcanic vent areas. Various sulfide or arsenide minerals were found in the hydrothermal vent B, C, and D. The mineralogy and geochemistry suggest higher hydrothermal activities in volcanic vent B, C, and D compared to vent A and inner caldera area. Therefore higher probabilities of massive sulfide deposits may occur in hydrothermal vent B, C, and D.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Blood Lead, Manganese, Aluminium and Silicon Concentrations in Korean Adults (한국인의 연, 망간, 알루미늄 및 실리콘의 혈중 농도)

  • Kim, Jung-Man;Ahn, Jung-Mo;Kim, Won-Sul;Kim, Jung-Il;Shin, Hai-Rim;Jung, Kap-Yeol;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.157-164
    • /
    • 2000
  • Objectives : This study was peformed to determine the reference values of blood lead, manganese, aluminium, and silicon in healthy adults. Methods : The subjects were 132 (67 male and 65 female), and classified to three age groups $(\leq39,\;40\sim49,\;and\;50\leq)$. Blood lead, manganese and aluminium were analyzed by atomic absorption spectrophotometer, and blood silicon was analyzed by direct current plasma optical emission spectrometer. Results : Blood lead levels(geometric mean, S.D) were (3.49, 1.70) ${\mu}g/dL$ in male and (3.04, 1.65) ${\mu}g/dL$ in female, but the difference is not significant, and there was no significant difference between age groups. Mean blood manganese level was $0.99{\pm}0.41{\mu}g/dL$, and there was no significant difference between sex or age groups. Mean blood aluminium level was $0.59{\pm}0.35{\mu}g/dL$, and there was no significant difference between sex or age groups. Mean blood silicon level was $54.41{\pm}27.64{\mu}g/dL$ in male and $43.34{\pm}23.51{\mu}g/dL$ in female, and the level in male was significantly higher than that in female (p<0.05). There was significant difference between age groups, and the oldest showed the highest level in male (p<0.05), but no significant difference between age groups in female. Conclusions : Authors hope that this study would provide basic data for determining reference values and evaluating health effects.

  • PDF

모재/중간층/박막의 H/E ratio 구배에 따른 Cr계 경질 박막의 기계적 특성에 관한 연구

  • Kim, Hoe-Geun;Song, Myeon-Gyu;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.135-135
    • /
    • 2018
  • 천이금속 질화물 코팅은 우수한 기계적 특성들로 인해 공구 코팅으로 많이 사용 되어왔다. 그 중에서도 특히 Cr계 경질 코팅은 높은 경도와 낮은 표면조도, 우수한 마찰특성 등 뛰어난 기계적 특성을 나타내므로 공구 코팅으로의 적용 가능성이 크다. 그러나 최근 공구산업의 발전으로 인해 공구가 더욱 가혹한 환경에서 사용됨에 따라, 공구의 수명을 향상시키고 보호하기 위해 코팅의 높은 밀착력이 요구되고 있으며, 모재와 코팅 사이에 중간층을 합성함으로써 공구의 밀착력을 향상시키는 연구가 활발히 진행되고 있다. 이전 연구에서 모재/중간층/코팅간의 경도와 탄성계수 비율(H/E ratio)의 구배가 코팅의 밀착력에 큰 영향을 미치는 것으로 확인되었다. 그러므로, WC 모재와 Cr계 코팅의 중간값의 H/E ratio를 갖는 중간층의 합성을 통해 코팅의 밀착력을 향상시킬 수 있을 것으로 판단된다. 본 연구에서는, 코팅의 밀착력을 향상시키기 위해 다양한 중간층을 증착한 CrZrN, CrAlN 코팅을 비대칭 마그네트론 스퍼터링 장비를 이용하여 합성하였다. 모재로는 디스크 형상의 WC-6wt.%Co 시편을 사용하였고 Cr, Zr, Si, Al single 타겟을 이용하여 Cr, CrN, CrZrN, CrZrSiN 등의 중간층이 증착된 코팅을 합성했다. 코팅의 합금상, 경도 및 탄성계수, 미세조직 및 조성, 표면 조도을 확인하기 위해 X-ray diffractometer (XRD), Fischer scope, field-emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), atomic force microscopy를 사용하였고, 코팅의 밀착 특성을 분석하기 위해 scratch tester와 optical microscopy (OM)를 이용하였다. 코팅의 내열성을 확인하기 위해 코팅을 furnace에 넣어 공기중에서 500, 600, 700, 800, 900, $1,000^{\circ}C$로 30분 동안 annealing 한 후에 nano-indentation을 사용하여 경도를 측정하였다. CrZrN 및 CrAlN 코팅을 나노 인덴테이션으로 분석한 결과, 모든 코팅의 경도(33.4-35.8 GPa)와 탄성계수(384.1-391.4 GPa)는 중간층의 종류에 상관없이 비슷한 값을 보인 것으로 확인됐다. 그러나, 코팅의 마찰계수는 중간층의 종류에 따라 다른 값을 보였다. CrZrN 코팅의 경우 CrN 합금상 중간층을 갖을 때 가장 낮은 값을 보였으며, CrAlN 코팅의 경우 CrN/CrZrSiN 중간층을 증착하였을때 마찰계수는 0.34로 CrZrN 중간층을 증착하였을 때(0.41)에 비해 낮은 값을 보였다. 또한, 코팅의 마모율 및 마모폭도 비슷한 경향을 보인 것으로 보아, CrN/CrZrSiN 중간층을 합성한 CrAlN 코팅의 내마모성이 상대적으로 우수한 것으로 판단된다. 코팅의 밀착력의 경우도 마찰계수와 비슷한 경향을 보였다. 이것은 중간층의 H/E ratio가 코팅의 내마모성에 미치는 영향에 의한 결과로 사료된다. H/E ratio는 파단시의 최대 탄성 변형율로써, 모재/중간층/코팅의 H/E ratio 구배에 따라 코팅 내의 응력의 완화 정도가 변하게 된다. WC 모재 (H/E=0.040)와 CrAlN 코팅(H/E=0.089) 사이에서 CrN, CrZrSiN 중간층의 H/E ratio는 각각 0.076, 0.083으로 모재/중간층/코팅의 H/E ratio 구배가 점차 증가함을 확인 할 수 있었고, 일정 응력이 지속적으로 가해지면서 진행되는 마모시험중에 CrN과 CrZrSiN 중간층이 WC와 CrAlN 코팅 사이에서 코팅 내부의 응력구배를 완화시키는 역할을 함으로써 CrAlN 코팅의 내마모성이 향상된 것으로 판단된다. 모든 코팅을 열처리 후 경도 분석 결과, CrN/CrZrSiN 중간층을 증착한 CrAlN 코팅은 $1,000^{\circ}C$까지 약 28GPa의 높은 경도를 유지한 것으로 확인 되었고, 이는 CrZrSiN 중간층 내에 존재하는 SiNx 비정질상의 우수한 내산화성에 의한 결과로 판단된다.

  • PDF

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF