• Title/Summary/Keyword: Atmospheric environment

Search Result 7,259, Processing Time 0.03 seconds

Interlaboratory Study of Sampling and Analysis Techniques for Ambient VOCs under Field Conditions (현장중심의 동시측정을 통한 환경대기 중 휘발성유기화합물의 측정방식 비교 연구)

  • 김기현;김조천;이강웅;허귀석;이병규
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.685-691
    • /
    • 2000
  • In order to provide basis for an accurate concentration determination of volatile organic compounds(VOCs) in air, four different institutions participated in simultaneous measurements of several VOC species under the experimental scheme of the Measurement and Analysis Division(MAD) of the Korea Society for Atmospheric Environment(KOSAE). Two types of experiments were undertaken by collecting and analyzing ambient air samples from the 7th floor of Natural Science Building, Han Tang University during two day periods of the late May 1998. The first typer of experiment was conducted as five consecutive experiments at 2-hour intervals by two institutions. On the other hand. the second type of experiment was performed as two -10hr sampling by three different institutions. The data obtained from different type of experiments were examined using various statistical approaches. In general, the results of these experiments indicated that the VOC data produced by a number of Korean institutions be fairly agreeable.

  • PDF

Study on moisture transport in concrete in atmospheric environment

  • Zhang, Weiping;Tong, Fei;Gu, Xianglin;Xi, Yunping
    • Computers and Concrete
    • /
    • v.16 no.5
    • /
    • pp.775-793
    • /
    • 2015
  • Moisture transport in concrete in atmospheric environment was studied in this paper. Based on the simplified formula of the thickness of the adsorbed layer, the pore-size distribution function of cement paste was calculated utilizing the water adsorption isotherms. Taking into consideration of the hysteresis effect in cement paste, the moisture diffusivity of cement paste was obtained by the integration of the pore-size distribution. Concrete is regarded as a two-phase composite with cement paste and aggregate, neglecting the moisture diffusivity of aggregate, then moisture diffusivity of concrete was evaluated using the composite theory. Finally, numerical simulation of humidity response during both wetting and drying process was carried out by the finite difference method of partial differential equation for moisture transport, and the numerical results well capture the trend of the measured data.

Comparing Meteorological Fields and Their Impacts on Carbon Bond Mechanism-IV Modeling

  • Lee, Hwa-Woon;Lee, Soon-Hwan;Kim, Heon-Sook
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.449-450
    • /
    • 2003
  • Performance of photochemical models and their response to emission controls are heavily dependent on the inputs to the model. Two key inputs to these models are accurate meteorological and emissions data. But they can contain significant errors which contribute to uncertainties in photochemical simulation (Kumar and Russell, 1996; Sistla et al., 1996; Pielke and Uliase, 1998; Barna and Lamb, 2000; Nelson L. Seaman, 2000: Hogrefe et al., 2001; Biswas et al., 2001).(omitted)

  • PDF

Comparison Study of Numerical Simulations Associated with Emission Conditions during Asian Dust Events

  • Kim, Yoo-Keun;Song, Sang-Keun;Jeong, Ju-Hee
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.518-519
    • /
    • 2003
  • Many studies of Asian dust have been undertaken to investigate dust sources, their transport and deposition mechanisms, their optical and chemical properties, and their physical characteristics. These studies have used meteorological parameters, optical thickness, and mineral compositions derived from satellite images, lidar, sunphotometer, and other ground-based instruments in East Asia (Chun et al., 2001; Murayama et al., 2001). (omitted)

  • PDF

The Reconstruction of Atmospheric Particle Size Distributions Using Optical Sensing Data and Some Regularization Methods l : Direct Methods (광측정 데이터와 최적화 방법들을 이용한 대기입자 크기분포 복원)

  • Kim, Seok-Seong;Yeon, Kyu-Hwang;Kim, Duck-Hyun
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.213-214
    • /
    • 2003
  • Atmospheric particles have a great deal of influences on the climate and the air quality, which change the living and industrial environments of a specific area. Especially, the suspended dusts and aerosols can often have a harmful influences on workers' health, equipments at working places. For this reasons, the measurement of atmospheric particle size distributions is of considerable current interest. (omitted)

  • PDF

Vertical Change in Extinction and Atmospheric Particle Size in the Boundary Layers over Beijing: Balloon-borne Measurement

  • Chen, Bin;Shi, Guang-Yu;Yamada, Maromu;Zhang, Dai-Zhou;Hayashi, Masahiko;Iwasaka, Yasunobu
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.3
    • /
    • pp.141-149
    • /
    • 2010
  • Aerosol size and number concentration were observed in the atmospheric boundary layer over Beijing (from near the ground to 1,200 m) on March 15 (a clear day) and 16 (a dusty day), 2005. The results were further compared with lidar measurements in order to understand the dependency of extinction on the particle size distribution and their vertical changes. The boundary layer atmosphere was composed of several sub-layers, and a dry air layer appeared between 400 and 1,000 m under the influence of dust event. In this dry air layer, the concentration of the fine-mode particles (diameter smaller than $1.0\;{\mu}m$) was slightly lower than the value on the clear day, while the concentration of coarse-mode particles (diameter larger than $1.0\;{\mu}m$) was remarkably higher than that on the clear day. This situation was attributed to the inflow of an air mass containing large amounts of Asian dust particles and a smaller amount of fine-mode particles. The results strongly suggest that the fine-mode particles affect light extinction even in the dusty atmosphere. However, quantitatively the relation between extinction and particle concentration is not satisfied under the dusty atmospheric conditions since laser beam attenuates in the atmosphere with high concentration of particles. Laser beam attenuation effect becomes larger in the relation between extinction and coarse particle content comparing the relation between extinction and fine particle content. To clarify this problem technically, future in situ measurements such as balloon-borne lidar are suggested. Here extinction was measured at 532 nm wavelength. Measurements of extinction at other wavelengths are desired in the future.

Performance indicator of the atmospheric corrosion monitor and concrete corrosion sensors in Kuwait field research station

  • Husain, A.;Al-Bahar, Suad Kh.;Salam, Safaa A. Abdul
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.981-994
    • /
    • 2016
  • Two field research stations based upon atmospheric corrosivity monitoring combined with reinforced concrete corrosion rate sensors have been established in Kuwait. This was established for the purpose of remote monitoring of building materials performance for concrete under Kuwait atmospheric environment. The two field research sites for concrete have been based upon an outcome from a research investigation intended for monitoring the atmospheric corrosivity from weathering station distributed in eight areas, and in different regions in Kuwait. Data on corrosivity measurements are essential for the development of specification of an optimized corrosion resistance system for reinforced concrete manufactured products. This study aims to optimize, characterize, and utilize long-term concrete structural health monitoring through on line corrosion measurement and to determine the feasibility and viability of the integrated anode ladder corrosion sensors embedded in concrete. The atmospheric corrosivity categories supported with GSM remote data acquisition system from eight corrosion monitoring stations at different regions in Kuwait are being classified according to standard ISO 9223. The two nominated field sites where based upon time of wetness and bimetallic corrosion rate from atmospheric data where metals and rebar's concrete are likely to be used. Eight concrete blocks with embeddable anodic ladder corrosion sensors were placed in the atmospheric zone adjacent to the sea shore at KISR site. The anodic ladder corrosion rate sensors for concrete were installed to provide an early warning system on prediction of the corrosion propagation and on developing new insights on the long-term durability performance and repair of concrete structures to lower labor cost. The results show the atmospheric corrosivity data of the environment and the feasibility of data retrieval of the corrosion potential of concrete from the embeddable sets of anodic ladder corrosion sensors.