• 제목/요약/키워드: Atmospheric diffusion

검색결과 214건 처리시간 0.025초

單一 排出源大氣汚染 短期모델에 관한 硏究 -Tracer Gas에 의한 擴散實驗- (On the Short Term Air Pollution Dispersion Model for the Single Souce -Diffusion Experiment With Tracer Gas-)

  • 李鍾範;姜寅求
    • 한국대기환경학회지
    • /
    • 제5권2호
    • /
    • pp.84-96
    • /
    • 1989
  • To evaluate the short term air pollution dispersion model, the diffusion experiment was conducted on the flat terrain near Chuncheon. Sulfur hexafluoride $(SF_6)$ gas was used to determine the horizontal spread of plume $(\sigmay)$ for calculated by CRSTER model. Results show that CRSTER model underestimates $\sigma$y because averaging time adjustment is not applied to calculate the $\sigma$y. The scheme that can estimate the atmospheric stability more accurate than Turner method, was presented.

  • PDF

p-n 접합 형성을 위한 반도체 실리콘 웨이퍼 대기압 플라즈마 붕소 확산 가능성 연구 (Study of Boron Doping Feasibility with Atmospheric Pressure Plasma for p-n Junction Formation on Silicon Wafer for Semiconductor)

  • 김우재;이환희;권희태;신기원;양창실;권기청
    • 반도체디스플레이기술학회지
    • /
    • 제16권4호
    • /
    • pp.20-24
    • /
    • 2017
  • Currently, techniques mainly used in semiconductor impurity diffusion processes include furnace thermal diffusion, ion implantation, and vacuum plasma doping. However, there is a disadvantage that the process equipment and the unit cost are expensive. In this study, boron diffusion process using relatively inexpensive atmospheric plasma was conducted to solve this problem. With controlling parameters of Boron diffusion process, the doping characteristics were analyzed by using secondary ion mass spectrometry. As a result, the influence of each variable in the doping process was analyzed and the feasibility of atmospheric plasma doping was confirmed.

  • PDF

크린센터 주변 부지 대기확산에 관한 연구 (A study on the atmospheric diffusion of land around the clean center)

  • 최홍주;전용한
    • Design & Manufacturing
    • /
    • 제15권2호
    • /
    • pp.49-55
    • /
    • 2021
  • In this study, CALPUFF, a three-dimensional atmospheric diffusion model, was used to predict the degree of influence of pollutants generated during clean center operation on surrounding areas. To drive the CALPUFF model, CALMET, a weather field calculation model, was used. Due to the influence of the wind field, air pollutants from the Clean Center diffused in the southeast direction, increasing the distribution area. SOx satisfies atmospheric environmental standards with an annual average value of 0.02 ppm or less NOx satisfies atmospheric environmental standards with an annual average value of 0.03 ppm or less. Dust (PM-10) satisfies atmospheric environmental standards with an annual average value of 50㎍/m3 or less and 24 hours average value of 100㎍/m3 or less. CO satisfies atmospheric environmental standards with an 8 hours average value of 9 ppm or less and an 1 hour average value of 25 ppm or less.

의사스펙트로법에 의한 대기확산현상의 수치모델(2): 실규모의 복잡지형에서의 스펙트로모델 (Numerical Models for Atmospheric Diffusion Phenomena by Pseudospectral Method(2) : Spectral Model for a Hilly Terrain of Real Scale)

  • 김선태
    • 한국대기환경학회지
    • /
    • 제9권3호
    • /
    • pp.242-246
    • /
    • 1993
  • Theoretically, spectral method has the highest accuracy among present numerical methods, but it is generally difficult to apply to complex terrains because of complex boundary conditions. Recently, spectral-element method, basically divide the domain into a set of rectangular subdomain and solve the equation at each subdomain, has been introduced. However, boundary conditions become more complex and requires more computing time, thus spectral-element method is not powerful for all complex terrain problems. In this paper, potential flow theory was intorduced to solve the air flows and diffusion phenomenon in the presence of terrain obstacles. Using the velocity potential-stream line orthogonal coordinate space, the diffusion problems of hilly terrain by pseudospectral method were solved and compared those with no terrain real scale solutions.

  • PDF

미기상 특성에 따른 대기오염 농도분포에 관한 연구 (A Study on the Distribution of Air Pollutant Concentration According to Micrometeorological Characteristics)

  • 김유근;홍정혜;전병일
    • 한국환경과학회지
    • /
    • 제3권1호
    • /
    • pp.31-38
    • /
    • 1994
  • The diffusion of the pollutants released into atmosphere is dependent on its chemical reaction, topography and micrometeorological characteristics. The purpose of the study is to investigate how much micrometeorological characteristics such as stability, wind speed and mixing height affect the diffusion of the air pollutants. For this purpose, this paper let 1) the basic theory be K-theory, 2) eddy diffusivity and wind speed be dependent on mixing height and stability, and 3) Grout method be used for numeric calculation. The result was 1) the more unstable condition, the higher mixing height and the higher wind speed we, the lower pollutants concentration appears, 2) the most intensive effect on the distribution of the pollutant concentration is the atmospheric stability.

  • PDF

대기중 이산화황 관측 방법들의 실측 비교 연구 (An Intercomparison of Atmospheric SO$_{2}$ Measurement Techniques)

  • 김경렬;이동수;이강웅
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.587-591
    • /
    • 1996
  • An intercomparison experiment was implemented to assess the uncertainties and precisions om atmospheric SO$_{2}$ measurement techiques including a pulsed fluorescence (P-F), a diffusion-scrubber /ion chromatography (D-I), and a mist-chamber/ion chromatography (M-I). Each of those three techniques was investigated by researchers at Seoul National University, Yonsei University, and Hankuk University of Foreign Studies, respectively. The concentrations of atmospheric SO$_{2}$ were determined concurrently using three independent measurement techniques at the Seoul National University campus, Korea during Nov.22 to Dec.2, 1995. While the results from the P-F and D-I techinques showed the very close agreements (within +-5%) throughout the experiment period, M-I technique showed systematically smaller values (up to 30%) than the other two techniques. Although sources of larger discrepancy between different techniques were mot identified, the lower SO$_{2}$ values of the M-I method may be related to the errors associated with sample collection effciency, mass flow rate measurements, and standardization of ion chromatography.

  • PDF

티타늄 합금의 표면 처리에 있어 표면 거칠기에 대한 레이저 유도 플라즈마 분광분석법 측정 적용 연구 (Laser-Induced Plasma Spectroscopy Measurement on Surface Roughness in Surface Treatment of Titanium Alloys)

  • 김지훈;김주한
    • 한국기계가공학회지
    • /
    • 제19권2호
    • /
    • pp.9-17
    • /
    • 2020
  • In this study, the surface changes of titanium alloy using laser surface treatment and the surface analysis using laser-induced plasma spectroscopy were carried out. The laser surface treatment induced changes in surface roughness and the diffusion of atmospheric elements. Excessive melting or less melting caused roughness changes, but when moderate levels of energy were applied, a smoother surface could be obtained than the initial surface. In the process, the diffusion of atmospheric elements took place. To analyze the diffusion of atmospheric elements with respect to surface morphology, the surfaces were re-shaped with grinding. In this experimental conditions, the effect of plasma formation by surface roughness was identified. Compensated plasma signals for the material properties were obtained and analysed by removing the background plasma signal.

쌍극자전하분포를 가진 정전섬유를 이용한 대전된 초미립자의 집진 (Ultrafine Particle Collection Using an Electret Fiber with a Dipole Charge Distribution)

  • 이명화;오타니 요시오;김종호;김신도
    • 한국대기환경학회지
    • /
    • 제21권2호
    • /
    • pp.145-153
    • /
    • 2005
  • An electret fiber with a dipole charge distribution was used to capture charged ultrafine particles in this study. Brownian diffusion and Coulombic force are the dominant collection mechanisms in the electret filtration of charged ultrafine particles. The interaction between Brownian diffusion and Coulombic force for the deposition of ultrafine particles onto a dipolarly charged fiber is studied by solving the convective diffusion equation including Coulombic force as an external force, and the numerical results are compared with the experimental data. As a result, it is shown that there is a negative interaction between Brownian diffusion and Coulombic force, i.e., Coulombic capture efficiency is reduced with decreasing Pe. These results suggest that Brownian diffusion and Coulombic capture efficiency, $\eta$$_{CD}$ is not a simple sum of Brownian diffusion efficiency, $\eta$$_{D}$ and Coulombic capture efficiency, $\eta$$_{C}$.

대기 혼합층 발달 과정의 모형 실험과 수치 해석 (Laboratory Experimentals and Numerical Analysis for Development of a Atmospheric Mixed Layer)

  • 이화운
    • 한국환경과학회지
    • /
    • 제2권1호
    • /
    • pp.17-26
    • /
    • 1993
  • The layer that is directly influenced by ground surface is called the atmospheric boutsdary layer in comparison with the free atmosphere of higher layer. In the boundary layer, the changes of wind, temperature and coefficient of turbulent diffusion in altitude are large and have great influences an atmospheric diffusion. The purpose of this paper is to express the structure and characteristics of development of mixed layer by using laboratory experiment and numerical simulation. Laboratory experiment using water tank are performed that closely simulate the process of break up of nocturnal surface inversion above heated surface and its phenomena are analyzed by the use of horizontally averaged temperature which is observed. The result obtained from the laboratory experiment is compared with theoretical ones from ; \textsc{k}-\varepsilon numerical model. The results are summarized as follows. 1) The horizontally averaged temperature was found to vary smoothly with height and the mixed layer developed obviously being affected by the convection. 2) The mean height of mixed layer may be predicted as a function of time, knowing the mean initial temperature gradient. The experimental values are associated well with the theoretical values computed for value of the universal constant $C_r$= 0.16, our $C_r$ value is little smaller than the value found by Townsend and Deardoru et al.

  • PDF

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.