• 제목/요약/키워드: Asymmetric wedge

검색결과 21건 처리시간 0.027초

6 MV Linac을 이용한 Symmetric field와 Asymmetric field에서 Wedge factor의 비교 고찰 (Intercomparison of Wedge factor for Symmetric field and Asymmetric field used 6MV Linac)

  • 지연상;한재진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.57-60
    • /
    • 1999
  • Therapy equipment have taken progress for Cancer make use of Radiation for the normal tissue system make much of important for shielding. In modern times independent jaw setting to used equipment as possible make use of asymmetric field. Therefore, the asymmetric field be leave out of consideration wedge factor because of with used wedge for the most of part. These experimentation find out have an effect on the dosimetry of out put compared with of the difference between the symmetric field and asymmetic field for the wedge factor.

  • PDF

대칭 및 비대칭 2차원 쐐기의 입수 충격에 관한 실험적 연구 (Experimental Study of Water Impact Loads on Symmetric and Asymmetric Wedges)

  • 김경환;이동엽;홍사영;김영식;김병완
    • 한국해양공학회지
    • /
    • 제28권3호
    • /
    • pp.209-217
    • /
    • 2014
  • In the present study, the water impact loads on two-dimensional symmetric and asymmetric wedges were mainly studied. The impact pressure and force were measured during a vertical drop of the symmetric and asymmetric wedges. The measured pressure was compared with analytic solutions. The measured force at a local area of the wedge was compared with the integrated pressures and analytic solutions. Some findings on symmetric and asymmetrical wedge drops are presented, and the reliability of the force sensor used for the measurement of the local impact force is discussed.

Theoretical Computation of the Capacitance of an Asymmetric Coplanar Waveguide

  • Song, Chan Mi;Kwon, Gina;Lee, Jong Min;Lee, Kang-Yoon;Yang, Youngoo;Hwang, Keum Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.393-399
    • /
    • 2018
  • An electrostatic boundary-value problem of a dielectric-wedge-backed, double-slotted conducting wedge is investigated to analyze an asymmetric coplanar waveguide with an infinite dielectric thickness using the Mellin transform and a mode-matching method. Our theoretical solution based on eigenfunction expansion and residue calculus is a rigorous and fast-convergent series form. Numerical computations are conducted to evaluate the potential field, capacitance, and characteristic impedance for various structures of the asymmetric coplanar waveguide. The computed results show good agreement with the simulated results.

Dynamic Wedge의 조직내 방사선량 분포의 특성 (Dosimetric Characteristics of Dynamic Wedge Technique)

  • 오영택;금기창;추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.323-332
    • /
    • 1996
  • 목적 : 방사선 치료에 있어서 조직내 등선량 분포곡선을 변형시킬 목적으로 쐐기 차폐물이 사용되고 있는데 최근 기존의 고정 쐐기와는 다르게 비대칭적인 콜리메이터인 Independent Jaw에 의해 등선량 분포곡선을 변형시키는 동적 쐐기 기법이 실용화 되고 있으나 아직 그 방사선 물리학적인 특성에 대해서는 잘 알려져 있지 않다. 이에 본 저자는 기존의 고정 쐐기와 비교하여 조직내 방사선량 분포의 특성을 알아보고자 본 연구를 계획하였다. 대상 및 방법 : 물 판톰, 폴리 스타이린 판톰, 평균 유방 모형 판톰을 대상으로 전리함, 필름, TLD 등을 이용하여 동적 쐐기와 고정 쐐기의 선량 분포를 측정하여 비교하였다. 방사선원은 선형 가속기의 6MV x선을 사용하였고 $15{\times}15$ 조사면에서 15, 30, 45도 쐐기를 이용하였다 조직내선량 분포는 전리함과 필름 선량계를 사용하였고, 유방 접선 치료방식에서의 반대편 유방 조사선량은 TLD를 사용하였다. 결과 : 1) 조직내 $\%$심도 선량은 고정 쐐기의 경우 심도 선량 깊이가 깊어지는 방사선의 경화 현상이 뚜렷하였으나 동적 쐐기의 경우에는 발견할 수 없었으며 그 $\%$심도선량은 개방 조사면과 유사하였다. 2) 조직내 등선량 분포 곡선을 보면 동적 쐐기의 경우 고정 쐐기와는 달리 원하는 깊이, 원하는 조사면에서 원하는 쐐기 각도를 얻을 수 있었으며 쐐기 각도를 이루는 등선량 분포 곡선이 고정 쐐기에 비해 더욱 직선적이었다. 3) 산란선량은 동적 쐐기의 경우 개방 조사면과 그 양이 거의 동일하였으며 유방보존술에서의 접선 조사방식의 방사선치료에서 고정 쐐기 대신에 동적 쐐기를 사용함으로써 반대측 유방으로의 피폭선량을 감소시킬 수 있었다. 결론적으로 동적 쫴기 기법은 단순히 고정 쐐기를 대체할 수 있을 뿐만 아니라 고정 쐐기의 단점을 보완해 줄 수 있으며 향후 방사선 치료에 있어서 더 다양한 유용성을 가질 수 있으리라 생각한다.

  • PDF

가변형 쐐기필터의 선량분포에 관한 특성 (Characteristics of dose distribution for virtual wedge)

  • 김부길;김진기
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.125-131
    • /
    • 2001
  • 방사선을 이용한 치료기인 의료용 선형가속기에 부착하여 선량분포 조절에 사용하는 가변형 쐐기필터(virtual wedge)의 선량분포 특성를 분석하고 쐐기각의 자료를 비교하여 가변형 쐐기필터 적용에서 오는 선량분포의 변화를 알아보고자 하였다. 기준전리함인 단일채널 PTW-UNIDOS과 3차원 선량계측시스템인 RFA-7 그리고 실험적으로 구성된 다중채널 검출기의 특성실험을 통하여 선량분포도 및 쐐기각을 구하고 이를 이용하여 실험적 검출시스템의 측정인자를 보정하였다. 가변형 쐐기필터의 쐐기각은 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ 에서 고정형 쐐기필터에 비교하여 1$^{\circ}$ 이내로 안정하였고, 60$^{\circ}$ 경우는 6 MV에서 1.2$^{\circ}$, 10WV 에서 2.2$^{\circ}$ 의 변화를 보였다. 측정에너지 영역 6, 10 MV 의료용 광자선을 적용하여 선량백분율과 빔평탄도 측정결과 검출기의 신뢰도가 평균 $\pm$2.1 % 이내였다. 고정형 쐐기필터를 이용한 쐐기각 변화율방법 적용시 방사선치료 과정에서 나타나는 선량오차 및 정상조직의 피폭을 줄이고 장비의 과도한 부하를 감소시키며 가변형 쐐기필터의 다양한 치료방법의 적용을 모색할 수 있었다. 가변형 쐐기필터 이용과 측정된 선량분포의 특성 분석으로 기존 고정형 쐐기필터 이용방법 및 기능을 보완하였고 실험적으로 구성된 계측시스템 측정장비의 대체방법 보정으로 가변형 쐐기필터의 다양한 치료방법적용과 보조물 사용에 따른 정확성과 효율을 높이는데 유용하리라 사료된다.

  • PDF

SUS304N 코일 웨지 인발 공정의 설계, 제조 및 평가 (Process Design, Fabrication, and Evaluation of Cold Drawn SUS304N Coil Wedge)

  • 정중은;김세종;배성준;남궁정;김성민;김성인;이광석
    • 소성∙가공
    • /
    • 제28권4호
    • /
    • pp.212-218
    • /
    • 2019
  • In this study, the first drawing die for the production of coil wedge is redesigned in order to enhance properties such as dimensional accuracy, dimensional uniformity, non-magnetism, and residual stress. The equivalent strain distribution is observed to be asymmetric at certain corners of the product and un-filling of material is also observed at the same location, based on the results of FEM simulation for the current drawing process. Additionally, a relatively huge amount of deformation is concentrated on the surface of the reference product leading to an increase in magnetic component and surface residual stress. After re-designing the cross-section of the first drawing step process conformed to relatively higher amount of reduction ratio, reduction of both surface residual stress and the volume fraction of magnetic component could be achieved for the finally-drawn coil wedge product.

열간 조압연에서 비대칭압연 해석 (Analysis of Asymmetric Plate Rolling in Roughing Mill)

  • 박해두;정진환;배원병
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2000년도 추계학술대회 논문집
    • /
    • pp.13-16
    • /
    • 2000
  • In the hot strip mill, a bad threading and shape of strip strip in the finishing mill was caused by asymmetric rolling In roughing min. Mathematical analysis for camber control of roughing mill in hot strip rolling has been developed. Each equation in the camber control model was derived from geometrical characteristics of camber mechanism. The model can predict variables such as wedge, side slippage and roll force difference etc. from a measured camber value and then find an optimum roll gap condition for minimizing camber in the next pass.

  • PDF

선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구 (Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools)

  • 이병용;나상균;최은경;김종훈;장혜숙;김미화
    • Radiation Oncology Journal
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 1997
  • 목적 :동적 쐐기 조사면 측정을 다중 검출기 시스템과 같은 특수한 장치없이 보편적인 방사선 측정 방법을 사용하여 시행할 수 있는 방법을 고안, 수행하였다. 대상 및 방법 : $15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ}$의 동적 쐐기각(dynamic wedge angle)과 6MV와 15MV인 광자선을 발생시키는 선형 가속기(CL 2100 C/D)를 이용하여 wedge transmission factor 및 percentage depth dose(PDD, 선량 프로파일을 측정하였다. Wedge transmission factor는 6MV, 15MV인 광자선과 $15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ}$의 4개의 동적 쐐기각에 대해서 $4\times4cm^2-20\times20cm^2$까지 1-2cm간격의 정사각형 조사면과 Y-field가 4cm, 20cm일 때 여러개의 X-field에 대한 각각의 직사각형 조사면에서 측정하였다. 또한 동적 쐐기의 구간별 치료표(Segmented Treatment Table, STT)값을 이용하여 wedge factor를 계산해 내었다. PDD는 필름 dosimetry로 구하였는데 개방 조사면에 대해 전리함과 필름으로 PDD를 구한 후 필름의 환산값을 알아내어 쐐기 조사면에 대한 필름 dosimetry로 PDD를 구하여 필름 환산값으로 전리함을 통해 얻을 수 있는 실제 PDD를 구하였다. 선량 프로파일은 비대칭 정지 조사면을 선택적으로 전리함을 이용하여 측정하고 이때 얻은 측정치인 소구간 프로파일과 STT를 이용하는 선량 분포 중칩 방식으로 구하였다. 결과 : wedge transmission factor의 측정치와 STT를 이용하여 구한 계산치를 비교한 결과 실험 오차 범위내에서 거의 일치하였다. 또한 직사각형 조사면에서의 wedge transmission factor 변화를 측정한 결과 동일한 Y-field에 대해서 직사각형 조사면은 정사각형 조사면에서의 wedge factor와 같았다. PDD는 필름 방사선 측정값의 보정으로 개방 조사면에서 PDD와 동적 쐐기 조사면에서 PDD 사이의 차이는 무시될 수 있다. 그리고 전리함의 측정으로부터 중칩 방식으로 얻어진 동적 쫴기의 선량 프로파일은 필름 dosimetry로 얻은 동적 쐐기의 선량 프로파일과 비교한 결과 최대 2% 이내 정확도의 허용 오차 영역에 들어옴을 볼 수 있었다. 결론 :동적 조사면의 특성으로 동적 쐐기 측정에서의 정보 수집을 위하여 모든 조사면에서의 방대한 측정과 그로인한 장시간의 소비, 또한 동적 쐐기 측정을 위한 특수한 장치가 필요하지만 보편적으로 사용하는 측정 장치, 즉 단일 검출기와 필름 방사선 측정 방법으로 충분히 용이하게 행할 수 있었다.

  • PDF

Enhanced Dynamic Wedge를 사용한 Mapcheck에서의 선량분포 평가 (Evaluation of the dose distribution in Mapcheck using Enhanced Dynamic Wedge)

  • 강수만;장은성;이병구;정봉재;신정섭;박철우
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.343-349
    • /
    • 2012
  • 세기조절방사선치료(intensity modulated radiation therapy ; IMRT)는 주변 정상장기 선량을 최소화하면서 종양에 집중적으로 고선량을 조사할 수 있는 장점으로 인하여 최근 그 사용이 급격히 증가하고 있다. 기능강화 동적쐐기 (enhanced dynamic wedge; EDW) 사용 시 기하학적 변화에 따른 Mapcheck에서의 선량분포를 측정 평가하고자 한다. Clinac ix에서 IMRT를 이용하여 EDW angle($10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$), field size(asymmetric field), depth 변화(1,5 cm, 5 cm)에 따른 선량분포를 검증하기 위해 Mapcheck위에 고체팬텀을 올려놓고 6 MV, 10MVX-ray로 100MU를 조사하였다. 6MV, 10MV의 에너지를 사용하여 기하학적변화에 따라 최대선량깊이(1.5 cm)와 5 cm 깊이에서 심부 선량백분율(percentage depth dose; PDD)은 치료계획장치에서 계산한 값의 차이가 최대 0.6%로 1%미만의 값으로 나타났다. 심부선량백분율은 조사야 중앙에서 최대선량깊이의 선량을 100%로 보았을 경우, 2.4%에서 7.2%의 범위에 있다. 또한 심부선량백분율 차이의 최대값은 Y2-OUT 방향에서 4.1%로 나타났고 Y1-IN 방향으로 1.7%로 나타났다. 동적쐐기를 사용하여 환자를 치료할 경우, 조사야 주변부의 불필요한 피폭을 유발하여 산란되는 선량을 줄이기 위하여 기능 강화 동적쐐기를 사용하는 것이 바람직할 것으로 사료된다. 특히 임상에서 환자를 치료할 경우, 쐐기의 toe방향 선량이 heel방향 선량보다 높다는 것을 염두에 두고 치료를 수행해야 할 것으로 사료된다.