• Title/Summary/Keyword: Assessment guideline

Search Result 653, Processing Time 0.029 seconds

The Study of ABEEK Accreditation Assessment Draft Statement in 2006 (2006년 공학교육 프로그램 인증평가 예비논평서 분석 연구)

  • Kang, So-Yeon;Kim, Mee-Kyoung;Kim, Myoung-Lang;Choi, Keum-Jin
    • Journal of Engineering Education Research
    • /
    • v.10 no.1
    • /
    • pp.77-85
    • /
    • 2007
  • Though accreditation demands considerable ongoing effort on the part of the college, about 10 percent of Korean engineering colleges has been accredited for 5years by ABEEK. It is true that engineering accreditation contributed the Korean engineering education to improve. Many engineering colleges which had prepared the engineering accreditation developed the integrating system for the engineering education, and over 50 engineering education research centers which assisted to programs in accreditation were founded. Also the faculty commitment to quality programs and excellence in teaching, continuous counseling for students, portfolio guiding and continuous quality improvement(CQI) etc. were performed for accreditation preparation. The engineering colleges preparing accreditation has made efforts for satisfying accreditation criteria, but it is difficult of modifying education systems which have been maintained by now. In addition, engineering colleges need guideline how to satisfy standards. The purpose of this study is to analyze draft statement of 4 universities which were evaluated in 2006 and to suggest the minimal resources for engineering colleges to prepare accreditation.

Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators (운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구)

  • Kim, Hyeong-Jin;Chang, Byung-Uck;Byun, Jong-In;Song, Myeong Han;Kim, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.44-51
    • /
    • 2013
  • ICRP recommended that cosmic ray exposure to the pilot and cabin crew would be considered as an occupational exposure due to their relatively high exposure. Since 2012 with the Act No. 10908 (Natural radiation management), the guideline of cosmic ray exposure to the pilot was established in Korea. The applicability of the solid-state nuclear track detector for personal dose assessment of pilot and cabin crew was evaluated. Dose linearity and angle dependence of dosimeters to the neutron were evaluated by $^{252}Cf$ neutron emitting source. The track density has a good agreement with the dose ($r^2$=0.99) and highly dependent on the degree of an angular of the dosimeter to the neutron source. In addition, the dosimeters (SSNTD) were exposed to cosmic ray in an aircraft during its cruising for more than two months in collaboration with Airline Pilots Association of Korea. Although the correlation between the track density from aircraft cruising altitude and expected neutron dose is low, however RSNS dosimeter could be used for personal neutron dosimeter. For application of RSNS as a personal dosimeter for pilot and cabin crew, additional studies are required.

Evaluation of Contamination Level of the Sediments from Chusori and Chudong Areas in Daechung Reservoir (대청호 추소 및 추동 수역 퇴적물의 오염도 평가)

  • Oh, Kyoung-Hee;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.277-284
    • /
    • 2015
  • In order to analyze the contamination level of sediment samples taken from Chusori and Chudong areas in Daechung Reservoir, the particle size and concentrations of organics and nutrients were analyzed and phosphorus fractionation analysis was conducted. The average fraction of silt-sized particles was 92% in the sediments taken from Chudong area and Chusori area at the site adjacent to main current, which was higher than that from the upper Chusori area. The concentrations of total phosphorus in the sediments at Chusori and Chudong area were 999 (${\pm}98$) and 1,123 (${\pm}119$) mg/kg sediment, respectively. The fractions of autochthonous phosphorus, which can be readily eluted by change of environmental conditions, were much higher than those of allochthonous phosphorus, indicating the internal load can contribute the eutrophication in these areas. The concentrations of total nitrogen were over 5,600 mg/kg sediment in all samples, which is the guideline of Contamination Assessment of River and Lake Sediments of the Ministry of Environment, indicating the contamination level of total nitrogen is serious in the sediments. It is concluded that the countermeasures to manage the quality of sediments are required to improve the water quality in the Daechung Reservoir.

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.

Product Review Data and Sentiment Analytical Processing Modeling (상품 리뷰 데이터와 감성 분석 처리 모델링)

  • Yeon, Jong-Heum;Lee, Dong-Joo;Shim, Jun-Ho;Lee, Sang-Goo
    • The Journal of Society for e-Business Studies
    • /
    • v.16 no.4
    • /
    • pp.125-137
    • /
    • 2011
  • Product reviews in online shopping sites can serve as a useful guideline to buying decisions of customers. However, due to the massive amount of such reviews, it is almost impossible for users to read all the product reviews. For this reason, e-commerce sites provide users with useful reviews or statistics of ratings on products that are manually chosen or calculated. Opinion mining or sentiment analysis is a study on automating above process that involves firstly analyzing users' reviews on a product to tell if a review contains positive or negative feedback, and secondly, providing a summarized report of users' opinions. Previous researches focus on either providing polarity of a user's opinion or summarizing user's opinion on a feature of a product that result in relatively low usage of information that a user review contains. Actual user reviews contains not only mere assessment of a product, but also dissatisfaction and flaws of a product that a user experiences. There are increasing needs for effective analysis on such criteria to help users on their decision-making process. This paper proposes a model that stores various types of user reviews in a data warehouse, and analyzes integrated reviews dynamically. Also, we analyze reviews of an online application shopping site with the proposed model.

Design and Integrity Evaluation of High-temperature Piping Systems in the STELLA-2 Sodium Test Facility (STELLA-2 소듐 시험 시설 고온 배관 계통의 설계 및 건전성 평가)

  • Son, Seok-Kwon;Lee, Hyeong-Yeon;Ju, Yong-Sun;Eoh, JaeHyuk;Kim, Jong-Bum;Jeong, Ji-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.775-782
    • /
    • 2016
  • In this study, elevated temperature design and integrity evaluation have been conducted using two different piping design codes for the high-temperature piping systems of sodium integral effect test loop for safety simulation and assessment(STELLA-2) being developed by KAERI(Korea Atomic Energy Research Institute). The design code of ASME B31.1 for power piping and French nuclear grade piping design guideline, RCC-MRx RD-3600 were applied, and conservatism of those codes was quantified based on the piping integrity evaluation results. The piping system of Model DHRS, Model IHTS and PSLS are to be installed in STELLA-2. The integrity evaluation results for the three piping systems according to the two design codes showed that integrity of the piping system was confirmed. As a code comparison result, ASME B31.1 was shown to be more conservative for sustained loads while RD-3600 was more conservative for thermal loads compared to B31.1.

Study of Mechanical Characteristics of Electric Cupping Apparatus in Korea for Suggestion of its Assessment Guideline (국내 평가 가이드 라인 제시를 위한 전동식 부항기의 특성 조사에 관한 연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The mechanical properties of Korean electric cupping systems are studied via experimental measurements. The study aimed at establishing the fundamentals of industrialization and systemization of oriental medicine device industry, as well as improving the quality of life for many Koreans. Methods : We reviewed the studies on traditional cupping as well as modern one to fine necessary factors for electric cupping systems. To characterize the mechanical properties of Korean electric cupping systems, we measured the pressure characteristics of commercially available electric cupping system by using an automatic pressure acquisition system and a standard cup. The pumping capability was checked at 40 seconds, and the stability of the suction cup was checked at 600 seconds. We also acquired the noise level of each system in clinical setting. To check the portability of each system, we also measured its physical dimensions. We scrutinized system manuals provided by the system manufacturers. Results : It took less than 5 second to reach the pressure if the connection between the air hose and the vacuum valve of the cupping system was secure. Pressure diminished to no more than 10% for 600s for all systems. Noise levels were 55~70 dB. Increase in pressure was too fast to control for a designated vacuum level except for one product. Conclusions : The Pumping ability of the systems is impressive and reliable. Pressure retention ability of each cup is quite reliable and reproducible. Therefore, their mechanical performances were worthy of recommendation. Some of them had noise level higher than 60 dB and they were bothersome. It was also suggested that the control for low to middle pressure needed to be accomplished by the cupping system.

Development of Guidelines for Setting Up Sensory Integration Rooms in Korea Using the Delphi Method (국내 감각통합치료실 구성을 위한 가이드라인 개발: 델파이 연구)

  • Lee, Chan-Hwa;Hwang, Sun-Mi;Park, Seo-Yul;Chae, Song-Eun;Kim, Jung-Ran
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.18 no.2
    • /
    • pp.1-14
    • /
    • 2020
  • Objective : This study presents guidelines for setting up a sensory integration room by applying the Delphi method. Methods : The Delphi method was applied in a survey of 22 expert panels asked to review sensory integration therapy from May to June 2020 to collect expert opinions. The survey was conducted in two rounds. The first round involved the collection of opinions based on prior research that used a total of 40 assessment tools, 23 closed questions about treatment tools, and 10 questions about the physical environment. Based on the results of the first round, the second was conducted using a process of item deletion and modification. Results : A total of 59 items were selected in the first round of the survey. In the second the contents of these 59 items were analyzed: each item scored .42 or higher, so no items were deleted. The stability of the survey was also calculated and found to be less than 0.5, so no further testing was required. The average content feasibility ratio of the final Delphi survey was .92, stability .15, convergence .36, and consensus .80, showing high agreement. Conclusion : This study is expected to help institutions and clinical therapists who want to create a sensory integration therapy room in their facilities by examining the physical environment, treatment tools, and evaluation tools used in sensory integration therapy rooms and understanding the views on such environments obtained from the clinical site to sensory integration therapists.

Assessment of Future Flood According to Climate Change, Rainfall Distribution and CN (기후변화와 강우분포 및 CN에 따른 미래 홍수량 평가)

  • Kwak, Jihye;Kim, Jihye;Jun, Sang Min;Hwang, Soonho;Lee, Sunghack;Lee, Jae Nam;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.85-95
    • /
    • 2020
  • According to the standard guidelines of design flood (MLTM, 2012; MOE, 2019), the design flood is calculated based on past precipitation. However, due to climate change, the frequency of extreme rainfall events is increasing. Therefore, it is necessary to analyze future floods' volume by using climate change scenarios. Meanwhile, the standard guideline was revised by MOE (Ministry of Environment) recently. MOE proposed modified Huff distribution and new CN (Curve Number) value of forest and paddy. The objective of this study was to analyze the change of flood volume by applying the modified Huff and newly proposed CN to the probabilistic precipitation based on SSP and RCP scenarios. The probabilistic rainfall under climate change was calculated through RCP 4.5/8.5 scenarios and SSP 245/585 scenarios. HEC-HMS (Hydrologic Engineering Center - Hydrologic Modeling System) was simulated for evaluating the flood volume. When RCP 4.5/8.5 scenario was changed to SSP 245/585 scenario, the average flood volume increased by 627 ㎥/s (15%) and 523 ㎥/s (13%), respectively. By the modified Huff distribution, the flood volume increased by 139 ㎥/s (3.76%) on a 200-yr frequency and 171 ㎥/s (4.05%) on a 500-yr frequency. The newly proposed CN made the future flood value increase by 9.5 ㎥/s (0.30%) on a 200-yr frequency and 8.5 ㎥/s (0.25%) on a 500-yr frequency. The selection of climate change scenario was the biggest factor that made the flood volume to transform. Also, the impact of change in Huff was larger than that of CN about 13-16 times.

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.