• Title/Summary/Keyword: Assembly Design

Search Result 1,646, Processing Time 0.026 seconds

Design of Radio Frequency Test Set for TC&R RF Subsystem Verification of LEO and GEO Satellites (저궤도 및 정지궤도위성의 TC&R RF 서브시스템 검증을 위한 RF 시험 장비 설계)

  • Cho, Seung-Won;Lee, Sang-Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.674-682
    • /
    • 2014
  • Radio Frequency Test Set (RFTS) is essential to verify Telemetry, Command & Ranging (TC&R) RF subsystem of both Low Earth Orbit (LEO) and Geostationary Earth Orbit (GEO) satellite during Assembly Integration & Test (AI&T). The existing RFTS was specialized for each project and needed to be modified for each new satellite. The new design enables RFTS to be used in various projects. The hardware and software was designed considering this and therefore it could be directly used in other projects within a similar test period without modification or inconvenience. It will be also easily controlled, modified, and managed through the extension in modularization according to each function and the use of COTS (commercial on-the-self) and this will improve system reliability. A more reliable RF test measurement is also provided in this new RFTS by using an accurate reference clock signal.

A Study on Effects of EGCG and Design Parameter for Drug-Eluting Biodegradable Polymer Stents (약물-용출 생분해성 고분자 스텐트를 위한 EGCG와 디자인 파라미터의 영향에 대한 연구)

  • Jung, T.G.;Lee, J.H.;Lee, J.J.;Hyon, S.H.;Han, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.111-116
    • /
    • 2013
  • Finite element analysis(FEA) has been extensively applied in the analyses of biomechanical properties of stents. Geometrically, a closed-cell stent is an assembly of a number of repeated unit cells and exhibits periodicity in both longitudinal and circumferential directions. This study concentrates on various parameters of the FEA models for the analysis of drug-eluting biodegradable polymeric stents for application to the treatment of coronary artery disease. In order to determine the mechanical characteristics of biodegradable polymeric stents, FEA was used to model two different types of stents: tubular stents(TS) and helicoidal stents(HS). For this modeling, epigallocatechin-3-O-gallate (EGCG)-eluting poly[(L-lactide-co-${\varepsilon}$-caprolactone), PLCL] (E-PLCL) was chosen as drug-eluting stent materials. E-PLCL was prepared by blending PLCL with 5% EGCG as previously described. In addition, the effects of EGCG blending on the mechanical properties of PLCL were investigated for both types of stent models. EGCG did not affect tensile strength at break, but significantly increased elastic modulus of PLCL. It is suggested that FEA is a cost-effective method to improve the design of drug-eluting biodegradable polymeric stents.

OECD/NEA BENCHMARK FOR UNCERTAINTY ANALYSIS IN MODELING (UAM) FOR LWRS - SUMMARY AND DISCUSSION OF NEUTRONICS CASES (PHASE I)

  • Bratton, Ryan N.;Avramova, M.;Ivanov, K.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.313-342
    • /
    • 2014
  • A Nuclear Energy Agency (NEA), Organization for Economic Co-operation and Development (OECD) benchmark for Uncertainty Analysis in Modeling (UAM) is defined in order to facilitate the development and validation of available uncertainty analysis and sensitivity analysis methods for best-estimate Light water Reactor (LWR) design and safety calculations. The benchmark has been named the OECD/NEA UAM-LWR benchmark, and has been divided into three phases each of which focuses on a different portion of the uncertainty propagation in LWR multi-physics and multi-scale analysis. Several different reactor cases are modeled at various phases of a reactor calculation. This paper discusses Phase I, known as the "Neutronics Phase", which is devoted mostly to the propagation of nuclear data (cross-section) uncertainty throughout steady-state stand-alone neutronics core calculations. Three reactor systems (for which design, operation and measured data are available) are rigorously studied in this benchmark: Peach Bottom Unit 2 BWR, Three Mile Island Unit 1 PWR, and VVER-1000 Kozloduy-6/Kalinin-3. Additional measured data is analyzed such as the KRITZ LEU criticality experiments and the SNEAK-7A and 7B experiments of the Karlsruhe Fast Critical Facility. Analyzed results include the top five neutron-nuclide reactions, which contribute the most to the prediction uncertainty in keff, as well as the uncertainty in key parameters of neutronics analysis such as microscopic and macroscopic cross-sections, six-group decay constants, assembly discontinuity factors, and axial and radial core power distributions. Conclusions are drawn regarding where further studies should be done to reduce uncertainties in key nuclide reaction uncertainties (i.e.: $^{238}U$ radiative capture and inelastic scattering (n, n') as well as the average number of neutrons released per fission event of $^{239}Pu$).

Hot-Fire Test of a Turbopump for a 30 Ton Class Engine in Real Propellant Environment (30톤급 엔진용 터보펌프 실매질 고온시험)

  • Hong, Soon-Sam;Kim, Jin-Sun;Kim, Dae-Jin;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-17
    • /
    • 2009
  • Hot-fire test of a turbopump for a gas generator cycle rocket engine of 30 ton class was carried out in real propellant environment. Liquid oxygen and kerosene were used for the oxidizer pump and the fuel pump, respectively, while hot gas produced by the gas generator was supplied to the turbine. A part of the propellant discharged from the pumps was provided to the gas generator. The turbopump was run stably at both on-design and off-design conditions, satisfying all the performance requirements. This paper describes one of the test cases, where the turbopump was run for 120 seconds at three different operating modes in one test. In terms of performance characteristics of pumps and turbine, the results from turbopump assembly test using real propellant showed a good agreement with those from the turbopump component tests using simulant working fluid.

  • PDF

Design and Applications of Graphics Interface on Personal Computer (개인용 컴퓨터상의 그래픽스 인터페이스 설계와 응용)

  • Kim, Jin-Han;Kyung, Chong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.1
    • /
    • pp.113-121
    • /
    • 1989
  • A software interface called CGI-K including device driver routines and graphics primitives for the grphic board "K" was designed, implemented in the Design Automation Laboratory of KAIST and installed on IBM PC/AT, using assembly and C language supported by TMS 34010 grphics processor. Several algorithms generating the graphics primitives such as box, circle, pie chord are proposed. The drawing speed of CGI-K on the graphic board K was found out to be three to ten times faster than that of the EGA for several examples. A 2-D graphics editor called GRIM (graphics input and modification) and a 3-dimensional graphics renderer called IPCHE which can draw 3-D objects were developed as two major application programs running on CGI-K. The graphics primitives supported in GRIM include polygon, box, circle, and ace. The IPCHE receives a 3-D objects data file and displays the 3-D object on the screen with hidden surface removal, shading, and perspective scaling.

  • PDF

Design of Bridge Transport System with Equal Incremental Telescopic Motion (동일신축 텔레스코픽모션을 갖는 천정이동장치 설계)

  • Yoon, Kwang-Ho;Lee, Hyo-Jik;Lee, Jong-Kwang;Park, Byung-Suk;Kim, Ki-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.227-235
    • /
    • 2010
  • This paper introduces the design of a bridge transport system with a telescopic tube for positioning equipment to perform remote handling tasks in a radioactive facility. It consists of an extensible and retractable telescopic tube assembly for z-direction motion, a cabling system for management of power and signal cables, and a trolley system for transverse motion and accommodating servo drives. The working environment for the bridge transport system with the telescopic tube requires strict geometrical constraints, including a short height, short telescopic tube length when retracted, and a long stroke. These constraints were met by solving a nonlinear programming problem involving the optimal dimensions. This paper introduces a cabling system for effective management of cables with changeable lengths to accommodate telescopic motions and a selection guide for servo drives that are sufficient to drive the system.

An Integrative Review of Depression Related to Intervention Studies for Women in Korea Journals (국내 여성우울 중재연구에 관한 분석-통합적 고찰)

  • Choi, Eun Young;Lee, Eun Hee;Hyun, Hye Jin;Byeon, Mi Kyeong
    • Women's Health Nursing
    • /
    • v.21 no.4
    • /
    • pp.284-296
    • /
    • 2015
  • Purpose: The aim of this study was to provide basic data on the intervention for depression program development and application by analyzing the depression intervention studies for women that were published in Korea Journal (2000~2014). Methods: The research method used was the integrative review. Nine studies were reviewed from the Nursing Articles and National Assembly Library of which 41 studies were from 126 research papers that met the inclusion criteria and analyzed using MINORS (Methodological Index for Non-Randomized Studies) and according to general characteristics. Results: There were non-equivalent control group pre-post test design (78%) in research design. 44% of articles in sample size were 14~26 participants and measuring tools were used CES-D (29%), BDI (I & II, 22%), GDSSF-K (22%). In quality of research according to MINORS, most of the papers got 2 scores except for the items of sample size calculation standard. Even though the similar intervention program were reported, the results could not compare because of diverse contents, duration, methods, and measuring tool with intervention program. As the results, aroma, massage, and counseling programs seemed to have significant effects of depression alleviation. Conclusion: The standard tailored program and measuring tool for depression alleviation of women was needed to develop.

A Case Study of Simulation for the Design of Crankshaft Line in an Automotive Engine Shop (자동차 엔진공장의 크랭크샤프트 라인설계를 위한 시뮬레이션 사례연구)

  • Moon, Dug-Hee;Xu, Te;Shin, Woo-Young
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.2
    • /
    • pp.1-12
    • /
    • 2008
  • The major components of an engine are the cylinder block, cylinder head, crankshaft, connecting rod, and camshaft, which are more popularly known as the 5 C's. Thus, the engine shop usually consists of six sub-lines, including five machining lines and one assembly line. The flow line is the typical concept of the layout when the engineer designs the engine shop. This paper introduces a simulation study regarding the new crankshaft machining line in a Korean automotive factory. The major factors for designing the machining line are considered, and their effects on the system performance are evaluated with a three-dimensional(3D) simulation model that is developed with $QUEST^{(R)}$. The initial layout is analyzed using the simulation model, and we suggest some ideas for improvement.

  • PDF

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

A Study on the Improvement of Spot Welding Quality of Wire Cu Alloy by Taguchi Method for Dynamic Characteristics (동특성 다구찌 기법을 통한 Cu합금 와이어의 스폿용접 품질향상 연구)

  • Suk, Ho-sam;Kim, Yeun-sung;Yoo, Choon-burn
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.1003-1020
    • /
    • 2017
  • Purpose: The purpose of this study is to find the optimum working conditions for spot welding of wire Cu alloys to achieve high-level quality. The parts subject to spot welding are brush card assemblies, which are the main module of the electric movement method of the car seat. Methods: In this study, the signal-to-noise ratio(SN ratio) and the loss function [L(y)] are used as Taguchi method for dynamic characteristics. Results: The results of the study are as follows. First, the analysis of variance using SN ratio showed 6 significant factors(p = 0.1% or less) among 7 factors except press force. Second, the optimal design of the dynamic characteristics is the tip exchange cycle: 50,000 ea., the welding time is 110 ms, the pressing force is 11 kgf/cm2, the rise time is 40 ms, and the tip dressing is 3,000 ea., Tip angle is 12o and electric current is 1,800 A. Conclusion: The validity of the spot welding process of the manufacturer's brush card assembly was verified and proved to be consistent with the study results. The results of this study are expected to standardize the welding conditions and guarantee the quality level required by the customers.