• Title/Summary/Keyword: Ascending aorta

Search Result 263, Processing Time 0.028 seconds

Bentall Operation in a Patient with a Unicommissural Unicuspid Aortic Valve

  • Park, Sung Joon;Lee, Jae Hoon;Chung, Eui Suk
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.368-371
    • /
    • 2019
  • A unicuspid aortic valve is a rare congenital malformation that frequently presents with valvular dysfunction and dilatation or aortic aneurysm, requiring combined aortic valve surgery and aortic repair. Some patients show severe valve calcification extending into the interventricular septum, possibly resulting in damage to the conduction system during debridement for valve replacement. We present a rare case of severe aortic stenosis with a unicommissural unicuspid aortic valve diagnosed by preoperative transesophageal echocardiography in a 36-year-old man. After composite graft replacement of the aortic valve, aortic root, and ascending aorta, a permanent pacemaker was placed because of postoperative complete heart block.

Early and Midterm Results of Hybrid Endovascular Repair for Thoracic Aortic Disease (흉부대동맥 질환에서 시행된 하이브리드 혈관내 성형술의 중단기 성적)

  • Youn, Young-Nam;Kim, Kwan-Wook;Hong, Soon-Chang;Lee, Sak;Chang, Byung-Chul;Song, Seung-Jun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.490-498
    • /
    • 2010
  • Background: A hybrid procedure using an open surgical extra-anatomic bypass of aortic arch vessels and thoracic endovascular aortic repair (TEVAR) is less invasive than open surgery, and provides a suitable proximal landing zone. Here we report our experience with a hybrid TEVAR procedure at a single center. Material and Method: We retrospectively reviewed consecutive patients with thoracic aortic disease who received a hybrid TEVAR procedure between August 2008 and January 2010. Patients' data were prospectively collected and mean follow-up was $10.8{\pm}5.5$ months (range 3~20). Result: Nine patients (7 males and 2 females) with a mean age of $63.8{\pm}15.8$ years (range 38~84) underwent a hybrid procedure. Five patients had an arch or a proximal descending aortic aneurysm, two had a dissecting aneurysm of the descending aorta, and two had an aneurysm of the ascending arch and descending aorta. Mean expected mortality calculated by logistic EuroSCORE was 21%. Six patients underwent debranching and rerouting from ascending aorta to arch vessels, 2 had carotid-carotid bypass grafting, and 1 underwent carotid-axillary bypass grafting. Mean operation time was $221.4{\pm}84.0$ min (range 94~364). Deployment success of endovascular stent grafting was 100% with no endoleak on completion angiography. There was no mortality, and a small embolism in the branch of the right opthalmic artery in one patient. During follow-up, one intervention was required for the endoleak. Actuarial survival at 20 months was 100%. Conclusion: Early and mid-term results are encouraging and suggest that hybrid TEVAR procedures are less invasive and safer and represent an effective technique for treating thoracic aortic disease.

Composite Graft Aortic Root Replacement with Coronary Button Reimplantation: The Early and Mid-Term Results (Composite graft를 이용한 대동맥근부 치환술: Button 술식의 중단기 결과)

  • 나찬영;백만종;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.356-364
    • /
    • 2002
  • Background: This study was undertaken to investigate the outcome of composite graft aortic root replacement using coronary button reimplantation technique for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and September 2001, 54 patients having aortic root replacement with a composite valve graft using direct coronary button reimplantation were reviewed retrospectively. Left ventricular dysfunction was present in 14 patients(25.9%), aortic regurgitation in 48(89%), and Marfan's syndrome in 17(31.5%). The indications for operation were annuloaortic ectasia in 29 patients(53.7%), aortic dissection in 11(20.4%), aneurysms of the ascending aorta involving aortic root in 12(22.2%), and aortitis in 2(3.7%). Six patients(11.1%) had previous cardiac or ascending aortic operations. Concomitant procedures were arch replacement in 21 patients(38.9%), coronary artery bypass graft in 7(13%), mitral valve repair or replacement in 4(7.4%), and others in 6. The mean time of circulatory arrest, total bypass, and aortic crossclamp were 18 $\pm$ 9 minutes, 177 $\pm$ 42 minutes, and 127 $\pm$ 31 minutes, respectively. Result: There was 1 early death(1.9%). Mean follow-up was 24.6$\pm$ 19.5 months. There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage. The Kaplan-Meier survival rate was 98.0 $\pm$ 2.0% and 93.1 $\pm$ 5.1% at 1 and 6 years, respectively. Two patients required reoperation owing to a false aneurysm at the root anastomosis site and a malfunction of prosthetic aortic valve(3.8%). Staged operation for dissection of the remaining thoracoabdominal aorta was performed in 1 patient. The freedom rate from reoperation was 97.8 $\pm$ 2.0% and 65.3 $\pm$ 26.7% at 1 and 6 years, respectively.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

A Study on Radiation Dose and Image Quality using Dual Energy Computed Tomography ECG Gating High Pitch Chest Pain Protocol Mode (이중 에너지 전산화 단층촬영 ECG Gating High Pitch Chest Pain Protocol 모드를 이용한 방사선량과 영상 품질에 관한 연구)

  • Kim, Gyeong-Rip;Sung, Soon-Ki;Kim, Chang-Hyeun;Kwak, Jong-Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.7-13
    • /
    • 2022
  • This study compared the aortic root image by using the ECG gating and non-ECG gating methods. We observed the presence or absence of progression of the aortic root image in the images examined by the high pitch (flash) chest pain protocol method and in the patients tested without ECG gating by the conventional method. The AAPM phantom was scanned by using high pitch (flash) chest pain protocol and general chest pain protocol. CTDI values were compared. By ECG gating, the blurring of ascending aorta was significantly reduced compared to the existing non-ECG gating test method, and the image quality of the aortic root was improved. Within the parametar range that did not show differences in noise, uniformity, and high contrast resolution, CTDI values were lower when tested with the high-pitch chest pain protocol. It was found that there is an advantage in dose reduction, and if it is applied and applied to diagnostic fields such as dissection using the dose reduction mode in the cardiac field, it is a very important test for patients who need rapid diagnosis and prompt treatment as well as a dramatic reduction in exposure dose. It is presumed to be a method.

Acute Aortic Injury after Nuss Bar Removal -A case report- (너스바 제거 후 발생한 급성 대동맥 손상 -치험 1예-)

  • Lee, Yang-Haeng;Park, Jae-Min;Han, Il-Yong;Yoon, Young-Chul;Hwang, Youn-Ho;Cho, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.11 s.268
    • /
    • pp.868-871
    • /
    • 2006
  • Nuss operation as a method for correction of pectus excavatum is safe and satisfactory, but its complication presents pneumothorax, displaced bar, wound infection, pericarditis, pleural effusion, hemothorax, cardiac injury etc. We report a rare case of acute ascending aortic rupture after displaced and adhered Nuss bar removal. The patient was a 30-years old man who received Nuss operation 3 years ago. Nuss bar was removed without resistance but massively bled at both operation wound, so immediately femoro-femoral CPB and median sternotomy was done and repaired proximal aortic arch under deep hypothermic total circulatory arrest. The patient was discharged without complication at postoperative 13 day.

Endovascular Aortic Balloon Clamping for Various Heart Disease (대동맥 내 풍선 차단법을 이용한 여러 가지 심장수술)

  • Choi, Jin-Ho;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • Background: Conventional ascending aortic cross clamping is often limited. This study was carried out to evaluate the safety and efficacy of an endovascular aortic clamping technique with an intraaortic balloon catheter. Material and Method: From April 2004 to January 2007, surgery with endoaortic clamping was performed in seven patients. A retrograde access perfusion (RAP) catheter was used in six patients and a Pruitt's balloon catheter in two patients. The indication for the operation was a retrosternal pseudoaneurysm of the aortic root in six patients, diffuse calcification of the ascending aorta with aortic regurgitation in 2 patients and an atrial septal defect in one patient. Five patients had at least two prior cardiac surgeries. Result: Successful insertion of the catheter and endoaortic clamping was achieved in all patients. Conclusion: The endovascular aortic clamping technique with a balloon catheter was a useful alternative method for patients in whom conventional cardiac surgery was limited.

Effect of Pulmonary Arterial Size on Postoperative Right Ventricular Pressure in Tetralogy of Fallot (활로씨 4 증후군에 폐동맥크기가 수술후 우심실압력에 미치는 영향)

  • 김용진
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.828-841
    • /
    • 1988
  • To predict the postoperative hemodynamic status of right ventricle preoperatively, a retrospective analysis was undertaken to determine the influence of pulmonary artery size on postoperative right ventricular pressure in 32 consecutive patients with tetralogy of Fallot who underwent total correction between July, 1987 to June, 1988 at the Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital. We have related the ratio of the postrepair peak systolic pressure in the right ventricle and the systemic systolic arterial pressure[PRV/Ao] to the preoperative cineangiographic measurement of pulmonary arterial tree, expressed as pulmonary artery index[PAI], the ratio of diameter of the right pulmonary artery to diameter of ascending aorta[r.PA/A.Ao], the ratio of right and left pulmonary artery to diameter of descending aorta[r.I.PA/D.Ao] There was tendency that the postrepair PRV/Ao seems to be related to the preoperative diameter of right and left pulmonary artery, but there were no statistically significant correlation with PAI, r.PA/A.Ao, r.l.PA/D. Ao to the ratio of the postoperative peak systolic right ventricular pressure and systemic systolic arterial pressure[PRV/Ao]. There was tendency to decrease the postoperative right ventricular pressure[PRV/Ao] about 11.2%[P < 0.025] within several hours than immediately after repair, but after then, there was no change of right ventricular pressure[PRV/Ao] significantly. There was good correlation of pressure change between the immediate and late postrepair right ventricular pressure[48 hour], and the derived linear regression line was; y=0.68534 0.1994[r=0.57294, P < 0.001]. There was no operative death due to residual high right ventricular pressure[PRV/Ao >0.75] related to hypoplastic pulmonary arterial development, thus we expect, for symptomatic patients even infants, that complete repair can be attempted when the pulmonary artery index[PAI] is over 108mm2/BSA, RPA/AAo is over 0.35, RPA LPA/D. Ao is over 1.36.

  • PDF

The analysis of 18F-FDG PET/CT Images According to the Time Flow (시간흐름에 따른 18F-FDG PET/CT의 영상 분석)

  • Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.47-51
    • /
    • 2012
  • PET/CT is taken 1 hour after $^{18}F$-FDG(F-18-fluoro-2-deoxy-D-glucose) injection. However, these would be often delayed for more than 2 or 3 hours due to equipment fault or unexpected situation. In the study, SUV(standardized uptake value) were measured from got image over time according to the parts of the body. As a result, there were great and small decrease in liver(middle of the right hepatic lobe), fat(Lt pelvis), lung (Rt upper lobe), aorta(ascending aorta level) of the body in delayed image, and ${\Delta}$SUVmax was increase of 37% in bone only(L5 vertebral body) of the body. ${\Delta}$SUVmax was increase of 37.6% in lesion, and the contrast degree was greater because of uptake increase in lesion and uptake decrease in the normal body.

Profound Hypothermia and Circulatory Arrest for Aneurysm Surgery (대동맥류 수술시의 초저체온법및 완전 순환차단에 관한 임상고찰)

  • Baek, Wan-Ki;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.511-517
    • /
    • 1992
  • From January 1988 to December 1990, 18 adult patients with aortic disease underwent surgical repair using hypothermia and total circulatory arrest. The age at operation ranged from 17 years to 64 years[mean 45.2$\pm$10.7 years]. We disease entities included aortic dissection in 12, aortoannuloectasia in 3 and thoracic aortic aneurysm in 3 cases. Partial cardiopulmonary bypass via femoral vessels along with surface cooling was used upon the induction of deep hypothermia[18~20oC]. Modified Bentall operation was performed in 7 cases, ascending aorta replacement in 6, graft interposition in descending thoracic aorta in 3 and others in 2 cases. The circulatory arrest was maintained for periods of 2 minutes to 86 mimutes[mean 34.7$\pm$5.0 minutes]. Overall hospital mortality was 27.8%[5/18]: brain damage was responsible for the death of 2 patients. 4 patients out of 13 survivors experienced postoperative neurologic dysfunction, which was proved to be self-limited except one case showing left hemiparesis. 12 patients were followed up postoperatively with the mean follow-up period 22.7$\pm$10.1 months. There was no death. No new neurologic problems were observed during follow-up period. All but one patient showing recurrent dissection and aortic regurgitation are in exellent clinical condition. These clinical data suggests that the principle of deep hypothermia and total circulatory arrest can be applied rather safely in adult patients, especially in the treatment of patients with aortic disease, it can be a valuable adjunct with better clinical results.

  • PDF