• 제목/요약/키워드: Artificial teeth movement

검색결과 18건 처리시간 0.019초

총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구 (A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE)

  • 권긍록;최대균
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구 (A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE)

  • 권긍록;박남수;최대균
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

Gothic arch tracing technique에 비교된 Simple tracing에 관한 연구 (A Comparative study of Simple Tracing with Gothic Arch Tracing)

  • 배봉진
    • 대한치과기공학회지
    • /
    • 제2권1호
    • /
    • pp.25-27
    • /
    • 1980
  • In the process of arranging artificial teeth the simple atracing technique was shown to be more precise and convenient for general use in dental clinic than gothic arch tracing. The simple tracing technique had some advantages over other ones in that they were very useful to check protrusive, lateral and central occlusion of mandible movement, and it was very easy to transfer the oral condition and mandible movements precisely onto the articulator. Also the technique was more effective than when using wax bite in that the functional movement range has shifted to 0.2 - 0.4mm form central occlusion.

  • PDF

총의치 교합면 형태가 하악골 응력 분포에 미치는 영향에 관한 삼차원 유한요소분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES UNDER COMPLETE DENTURES WITH VARIANT ARTIFICIAL TEETH FORMS AND OCCLUSAL PATTERNS)

  • 이철규;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.351-384
    • /
    • 1993
  • Complete denture occlusion must be developed to function efficiently and with the least amount of trauma to the supporting tissues. For the preservation of supporting tissues, it is imperative to reduce to a minimum the functional stress induced by dentures. The magnitude of the horizontal component of functional stress contributed by various occlusal teeth forms has not been studied. This study was aimed to investigate the influence of different occlusal teeth forms on the mode of distribution of the stresses in the mandibular tissue, and the displacement of lower dentures during the variant functional movement of mandible for this study three dimensional finite element analysis was used. FEM models were created using commercial software Super Sap for IBM 32 bit computer. The model was composed of 3380 brick elements and 4346 nodes. The results were as follows. 1. The magnitude of stress was similar between two models in centric occlusion, in the case of anatomic model, the stress was concentrated on the buccal side of alveolar ridge beneath the bicuspids. 2. During the protrusive movement, the increasing of stress from the posterior to anterior part of mandible was seen in the case of anatomic model. 3. During the lateral movement, the stress of anatomic model was greater than that of nonanatomic model. 4. The stress of anatomic model was concentrated on the anterior region of residual ridge during the lateral movement. 5. In the case of anatomic model the anterior part of denture was displaced severely at the centric and lateral position, but the denture of nonanatomic model was displaced minutely at the protrusive and lateral position.

  • PDF

의치주위조직(義齒周圍組織)의 기능인상(機能印象) 채득법에 의한 0$^{\circ}$ 구치(臼齒)의 Full Denture 제작법(製作法) ("A Study of Farbricating Full Denture, Which is Used Functional Imp and Zero-degree Artificial Poster Teeth")

  • 김의남
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.33-40
    • /
    • 1985
  • When full denture is being fabricated, pronounciation, recovery of aesthetics of function and mastificatory function should be satisfies for patients. To satisfy for the function of denture, following is the difference between this new way of fabricating and formerly one of it. 1. The size of fabricating tooth which is harmony of original oral structure for patients is deaded by manufacturing labial index and artificial tongue. 2. By the use of artificial tongue and labial index, the arranges of artificial tooth is to become harmony of oral structure. 3. Formation of gingival decided functional impression which is used by impression paste, is harmony of oral structure. Therefore, this full denture can be satisfied with pronouncing oral function of recovery of aesthetics as well as mastificatory through physiological movement of oral tissue not disturbed with anything but cooperated drastically. In manufacturing of this full denture, both dentist and dental technician under cooperation need to proceed the work on the base of importance of communication.

  • PDF

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

성인 구순구개열 환자에서 Multidisciplinary 치료로 기능성 교합을 형성한 증례 (Multidisciplinary Treatment Approach in a Secondary Cleft Lip and Palate Patient for Functional Occlusal Rehabilitation)

  • 이지나
    • 대한구순구개열학회지
    • /
    • 제15권1호
    • /
    • pp.29-38
    • /
    • 2012
  • A 20 year-old cleft lip and palate patient came for occlusal rehabilitation, but the constricted maxilla and early loss of posterior teeth called for an unusual treatment modalities. Distraction osteogenesis in the edentulous areas followed by artificial bone graft, dental implant along with orthodontic tooth movement were planed. Multidisciplinary treatment enabled both esthetic and functional oral rehabilitation of this patient.

  • PDF

총의치의 납의치 상에서 치은 형성 시행 후에 나타나는 시간에 따른 인공 치아 이 동에 대한 평가 (Complete denture artificial teeth arrangement deformation in wax denture after festooning: deformation over time)

  • 이세한;곽영훈;김희중
    • 구강회복응용과학지
    • /
    • 제34권4호
    • /
    • pp.262-269
    • /
    • 2018
  • 목적: 치은 형성 후 인공치아의 이동에 대하여 평가를 시행하였다. 연구 재료 및 방법: 10벌의 동일한 치아배열과 치은의 외형을 가진 납의치를 이용하여 실험하였다. 이 납의치 상에서 치은 형성을 시행하였고, 10분 간격으로 120분 간 모델 스캔을 시행하여 치아 간 거리를 측정하였다. SPSS Ver. 22. 0를 이용하여 통계학적 분석을 시행하였다. 결과: 치은 형성 후 평균적으로 치아 사이의 거리가 0.0999 mm에서 0.1787 mm로 나타났다. 인공치아 이동의 변화율에 대해서는 40 - 50분과 50 - 60분 사이와 50 - 60분과 60 - 70분 사이에서 통계학적으로 유의한 차이가 관찰되었고, 그 이후에는 변화율의 유의한 차이가 없었다. 결론: 120분 간 측정한 결과 인공치아의 이동이 관찰되었고, 60 - 70분 이후에는 시간에 따른 평균 이동량의 변화가 관찰되지 않았다. 이를 종합하면, 치은 형성 후 60분 이상 경과된 시점에서 교합에 대한 재평가를 시행한 후에 최종 의치를 제작하는 것이 필요하다.

상악 제1 및 제2소구치의 발치공간 폐쇄기전에 대한 3차원 유한요소 해석의 비교 연구 (Comparison of finite element analysis of the closing patterns between first and second premolar extraction spaces)

  • 고신애;임원희;박선형;전윤식
    • 대한치과교정학회지
    • /
    • 제37권6호
    • /
    • pp.407-420
    • /
    • 2007
  • 교정 치료에서 발치공간 폐쇄는 치열을 이루는 모든 치아의 연속적인 이동으로 이루어지므로 그 기전은 복잡하다. 특히 전치부 치축을 적절히 유지하면서 구치부 고정원을 조절하는 과정은 정교함을 요하기 때문에 입체적 분석을 통한 치아이동 양상에 대한 이해가 필요하다. 지금까지의 유한요소 분석은 초기 응력분포를 관찰하여 치아 이동양상을 예측해 보는데 그쳤지만 이러한 양상만으로 정확한 치아이동 결과를 추정하는 데에는 한계가 있었다. 따라서 본 연구에서는 3차원 유한요소 모델을 이용하여 상악 제1소구치 및 제2소구치 발치공간 폐쇄 시 전치부와 구치부의 입체적인 이동 양상을 단계별로 비교하여 그 기전을 규명하고자 하였다. 자연치의 크기 및 형태를 갖는 상악 치아들과 브라켓, 교정용 호선 및 치조골부를 3차원 레이저 스캐너로 스캐닝한 후 사면체 요소의 유한요소 모델을 제작하였다 $0.017"{\times}0.025"$ 스테인레스 강 호선에 제작된 bull 루프 후방에 $10^{\circ}$ gable bend를 부여하고 한 번에 2 mm씩 12회 활성화시켜 발치공간을 폐쇄시켰다. 그 결과 제1소구치를 발치한 경우 제2소구치 발치에 비해 전치부의 후방 이동량이 많았으며 구치부의 전방 이동량은 더 적게 나타났다. 전치부에서는 제f, 2소구치 발치 모두 비슷한 미약한 정출을 동반하였고 치축의 변화량은 제1소구치 발치에서 더 크게 나타났다. 또한 제2소구치 발치 시 고정원의 협측 이동량이 더 크게 나타났다

Space supervision을 이용한 치성 정중선 변위의 교정 (CORRECTION OF DENTAL MIDLINE DEVIATION BY MEANS OF SPACE SUPERVISION)

  • 김수연;최영철;박재홍;최성철;김광철
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.700-708
    • /
    • 2007
  • 상하악 중절치 간의 정중선 변위는 골격성 변위, 치성 변위 및 골격성과 치성의 복합적 변위 등으로 구분된다. 그 중치성 정중선 변위는 치열의 발육시기에 따라 다양한 방법으로 치료 방법을 선택할 수 있다. 특히 혼합치열의 초기에는 치열 내에 존재하는 공간의 조건, 인접 영구치의 맹출 시기 또는 맹출 방향에 따라 영구 절치들의 위치가 자발적으로 변화, 개선될 수 있다. 따라서 이러한 치아의 생리적 이동을 이용하여 특별한 교정장치의 이용 없이 치열 내에서 치아의 배열을 개선시킬 수 있다. 본 증례보고에서는 특히 유견치의 발거 시기 및 좌우 유치의 발거 순서 등을 이용하여 치성 정중선 불일치를 개선시킨 증례들을 보고하고자 한다.

  • PDF