• Title/Summary/Keyword: Arrays

Search Result 2,107, Processing Time 0.032 seconds

Fabrication of Nanodot Arrays Via Pulsed Laser Deposition Technique Using (PS-b-PMMA) Diblock Copolymer and Anodic Aluminum Oxide Templates (고분자 공중합체와 알루미늄 양극 산화막 템플레이트를 이용한 나노점 배열 형성)

  • Park Sung-Chan;Bae Chang-Hyun;Park Seung-Min;Ha Joeng-Sook
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2006
  • We have fabricated nanodot arrays by using phase separated (PS- b- PMMA) diblock copolymer film and anodic aluminum oxide (AAO) membrane as templates with hexagonal arrays of cylindrical microdomains perpendicular to the substrate. Pulsed laser deposition technique was used to deposit various kinds of materials including Ag, Ni, ZnO, Si:Er, and Co/Pt onto Si substrates. The size and separation of nanodots correspond to those of the templates used, The density of nanodots was estimated to be $6{\times}10^{11}/cm^2$ and $1{\times}10^{10}/cm^2$ when the diblock copolymer and AAO were used, respectively. In particular, the optical properties of ZnO and Si: Er nanodot arrays were investigated and the strong photoluminescence at 380 nm and $1.54{\mu}m$ was observed from ZnO and Si:Er nanodot arrays, respectively.

Quantitative and Rapid Analysis of Transglutaminase Activity Using Protein Arrays in Mammalian Cells

  • Kwon, Mi-Hye;Jung, Jae-Wan;Jung, Se-Hui;Park, Jin-Young;Kim, Young-Myeong;Ha, Kwon-Soo
    • Molecules and Cells
    • /
    • v.27 no.3
    • /
    • pp.337-343
    • /
    • 2009
  • We developed a novel on-chip activity assay using protein arrays for quantitative and rapid analysis of transglutaminase activity in mammalian cells. Transglutaminases are a family of $Ca^{2+}$-dependent enzymes involved in cell regulation as well as human diseases such as neurodegenerative disorders, inflammatory diseases and tumor progression. We fabricated the protein arrays by immobilizing N,N'-dimethylcasein (a substrate) on the amine surface of the arrays. We initiated transamidating reaction on the protein arrays and determined the transglutaminase activity by analyzing the fluorescence intensity of biotinylated casein. The on-chip transglutaminase activity assay was proved to be much more sensitive than the $[^3H]putrescine$-incorporation assay. We successfully applied the on-chip assay to a rapid and quantitative analysis of the transglutaminase activity in all-trans retinoic acid-treated NIH 3T3 and SH-SY5Y cells. In addition, the on-chip transglutaminase activity assay was sufficiently sensitive to determine the transglutaminase activity in eleven mammalian cell lines. Thus, this novel on-chip transglutaminase activity assay was confirmed to be a sensitive and high-throughput approach to investigating the roles of transglutaminase in cellular signaling, and, moreover, it is likely to have a strong potential for monitoring human diseases.

Directional Characteristics of Sleeve-gun Arrays in Marine Seismic Survey (해양 탄성파 탐사에서 슬리브건 배열의 방향 특성)

  • Yoo, Hai-Soo;Yang, Sung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.71-80
    • /
    • 1996
  • Characteristics of sleeve-gun arrays installed on the R/V Onnuri were analyzed and compared with survey data. In the case of cluster array, the beam width in the frequency range up to 814Hz is constant as $179.5^{\circ}$, and rapidly narrows in the frequency range of 814-1631Hz. However, in the case of long and wide arrays, as the frequency increases, the beamwidth decreases. The optimal frequency is 69Hz. the main lobe of vertical inclination has its maximum amplitude at phase angle $0^{\circ}$. The optimal frequency of cluster array which produces little side lobe is less than 1631Hz, and those of long and wide arrays are less than 108Hz. As a result, the cluster array produces a good source for high-resolution seismic survey, while the long and wide arrays are suitable for the survey of deep structures. The final high-resolution seismic section with cluster array was compared with that of long and wide arrays.

  • PDF

A Study on the Modified Electrode Arrays in Two-Dimensional Resistivity Survey (2차원 전기비저항 탐사를 위한 변형된 전극배열법에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.3
    • /
    • pp.59-69
    • /
    • 2001
  • Five kinds of modified electrode arrays were proposed to overcome the weak points of the commonly used arrays using dipole and/or pole in two-dimensional resistivity surveys. The modified pole-pole array was suggested to overcome the inefficiency caused by distant earthing in pole-pole array. Four kinds of modified arrays using dipole were designed to enhance the signal-to-noise ratio of the conventional dipole-dipole and pole-dipole arrays through boosting up the measured potential difference. In the numerical experiments using the two-dimensional modeling and inversion, the effects of the ambient electrical noise and the resolving power were examined and the results showed the validity of the modified arrays proposed in this study.

  • PDF

Fabrication of Flexible Energy Harvester Based on BaTiO3 Piezoelectric Nanotube Arrays (BaTiO3 압전 나노튜브 어레이 기반의 플렉서블 에너지 하베스터 제작)

  • Seo Young Yoon;Cheol Min Kim;Bitna Bae;Yujin Na;Haksu Jang;Kwi-Il Park
    • Journal of Powder Materials
    • /
    • v.30 no.6
    • /
    • pp.521-527
    • /
    • 2023
  • Piezoelectric technology, which converts mechanical energy into electrical energy, has recently attracted drawn considerable attention in the industry. Among the many kinds of piezoelectric materials, BaTiO3 nanotube arrays, which have outstanding uniformity and anisotropic orientation compared to nanowire-based arrays, can be fabricated using a simple synthesis process. In this study, we developed a flexible piezoelectric energy harvester (f-PEH) based on a composite film with PVDF-coated BaTiO3 nanotube arrays through sequential anodization and hydrothermal synthesis processes. The f-PEH fabricated using the piezoelectric composite film exhibited excellent piezoelectric performance and high flexibility compared to the previously reported BaTiO3 nanotube array-based energy harvester. These results demonstrate the possibility for widely application with high performance by our advanced f-PEH technique based on BaTiO3 nanotube arrays.

A Study of Individual Differences across Numerosity Sensitivity, Visual Working Memory and Visual Attention (수량민감도와 시각작업기억 및 시각적 주의 간 개인차 연구)

  • Kim, Giyeon;Cho, Soohyun;Hyun, Joo-Seok
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.3-18
    • /
    • 2015
  • Numerosity perception is considered as an innate ability of human being where its sensivitiy may widely vary across each individual person. The present study explored the relationship between visual working memory (VWM), visual search efficiency, and numerosity sensitivity. To accomplish this, we calculated each participant's K-value from change detection performance representing one's storage capacity in VWM, slopes of search RTs representing the search efficiency, and discrimination sensitivity for a quantity difference across two sets of dot arrays representing the numerosity sensitivity. The correlational analysis across the measurements revealed that participants with a high VWM capacity better discriminated the numerosity difference in the arrays when the spatial information in the two dot arrays was preserved. In contrast, the participants with high search efficiency discriminated better the difference in the arrays when the spatial information in the arrays was not preserved. The results indicate high VWM-capacity individuals were presumably able to use a strategy of storing the dot arrays by grouping them into a smaller pattern of dot arrays while high search-efficiency individuals were able to use a strategy of rapidly switching their focused attention across the dots in the arrays to count each individual dot. These in sum suggest that individual differences in numerosity sensitivity rely on one's working memory capacity as well as their efficient use of switching focused attention.

THE NUMBER OF CONFIGURATION ON RECTANGULAR ARRAYS

  • Park, Ji Hyun;Jung, Wan Soo;Park, Dae Yeon
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.8 no.1
    • /
    • pp.95-104
    • /
    • 1995
  • In this paper, we derive the formular that the number of configuration on the rectangular arrays is counted by the composite shift operator method.

  • PDF

A Color-Filterless LCD with RGB LED and Lenticular-Lens Arrays

  • Kwon, Jin-Hyuk
    • Journal of Information Display
    • /
    • v.11 no.2
    • /
    • pp.45-48
    • /
    • 2010
  • A direct-lit liquid crystal display that does not use color filters is proposed. A backlight unit that employs compartmentalized RGB LED and lenticular-lens arrays is used instead of color filters to direct the RGB LED lights into the RGB subpixels. The color-filterless LED backlight design, simulation, and experiment results are presented.