• Title/Summary/Keyword: Array temperature

Search Result 586, Processing Time 0.036 seconds

Simultaneous Analysis of Bioactive Metabolites from Lonicera japonica Flower Buds by HPLC-DAD-MS/MS (HPLC-DAD-MS/MS를 이용한 금은화 생리활성 물질의 동시분석)

  • Ryu, Sung-Kwang;Jeon, Ju-Eun;Kang, Gyoung-Won;Kang, Sam-Sik;Shin, Jong-Heon
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.446-451
    • /
    • 2008
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) and electrospray ionization mass spectrometry (ESI-MS) was established for the simultaneous determination of chlorogenic acid (1), sweroside (2), luteolin-7-O-glucoside (3), (E)-aldosecologanin (4) and 3,5-dicaffeoylquinic acid (5) from Lonicera joponica flower buds. The optimal chromatographic conditions were obtained on an ODS column (5 ${\mu}m$, 4.6${\times}$150 mm) with the column temperature $25^{\circ}C$. The mobile phase was composed of (A) water with 0.1% formic acid and (B) acetonitrile with 0.1% formic acid using a gradient elution, the flow rate was 0.3 ml/min. Detection wavelength was set at 250 nm. All calibration curves showed good linear regression ($r^2$>0.994) within test ranges. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.05${\sim}$1.95% and 0.15${\sim}$2.26%, respectively, and the overall recoveries of 97.71${\sim}$103.65% for the five compounds analyzed. The verified method was successfully applied to quantitative determination of the three types (phenolic compounds, iridoids and flavonoids) of bioactive compounds in 21 commercial L. japonica flower buds samples from different markets in Korea and China. The analytical results demonstrated that the contents of the five analytes vary significantly with sources.

MOLECULAR GAS AND RADIO JET INTERACTION: A CASE STUDY OF THE SEYFERT 2 AGN M51

  • MATSUSHITA, SATOKI;TRUNG, DINH-V;BOONE, FRDERIC;KRIPS, MELANIE;LIM, JEREMY;MULLER, SEBASTIEN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.439-442
    • /
    • 2015
  • We observed multiple CO transition lines and the HCN(1-0) line at ~ 1" (~ 34 pc) or higher resolution toward the Seyfert 2 nucleus of M51 using the IRAM Plateau de Bure Interferometer (PdBI) and the Submillimeter Array (SMA). All the images show very similar overall molecular gas distribution; there are two discrete clouds at the eastern and western sides of the nucleus, and the western cloud exhibits an elongated distribution and velocity gradient along the radio jet. In addition, high HCN(1-0)/CO(1-0) brightness temperature ratios of about unity have been observed, especially along the radio jet, similar to those observed in shocked molecular gas in our Galaxy. This strongly indicates that the molecular gas along the jet is shocked, that the radio jet and the molecular gas are interacting, and the jet is entraining both diffuse (CO) and dense (HCN) molecular gas outwards from the circumnuclear region. This is the first clear imaging of the outflowing molecular gas entrained by the AGN jet, and showing the detailed physical status of outflowing molecular gas. Since a relatively high HCN(1-0)/CO(1-0) ratio has been observed in the high velocity wing of ultraluminous infrared galaxies, it can also be explained by a similar mechanism to those we describe here.

투명 산화물 트랜지스터

  • Park, Sang-Hui;Hwang, Chi-Seon;Jo, Du-Hui;Yu, Min-Gi;Yun, Seong-Min;Jeong, U-Seok;Byeon, Chun-Won;Yang, Sin-Hyeok;Jo, Gyeong-Ik;Gwon, O-Sang;Park, Eun-Suk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.13.1-13.1
    • /
    • 2009
  • Transparent electronics has attracted many interests, for it can open new applications for consumer electronics, transportation, business, and military. Among them, display backplane, thin film transistor (TFT) array would be the most attractive application. Many researchers have been investigating oxide semiconductors for transparent channel material of TFT since the report for transparent amorphous oxide semiconductor (TAOS) TFT by Hosono group and ZnO TFT by Wager group. Especially, oxide TFTs have been intensively investigated during a couple of years since the first demonstration of ZnO-TFT driving AM-OLED. Many papers regarding the fabrication and performance of oxide TFTs, and active matrix display driven by oxide TFTs have been reported. Now lots of people have confidence in the competitiveness of oxide TFTs for the backplane of AM-Display. Especially, high mobility, uniformity, fairly good stability, and low cost process make oxide TFTs applied even to a large size AM-OLED. Last year, Samsung mobile display, former SID, reported 12" AM-OLED driven by IZGO-TFT and it seems that the remained issue for the mass production is the bias temperature stability. Here, we will introduce the application of oxide TFT and important issue for oxide TFT to be used for the direct printing.

  • PDF

Nitrogen Monoxide Gas Sensing Properties of CuO Nanorods Synthesized by a Hydrothermal Method (수열합성법으로 합성된 산화구리 나노막대의 일산화질소 가스 감지 특성)

  • Park, Soo-Jeong;Kim, Hyojin;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.24 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • We report the nitrogen monoxide (NO) gas sensing properties of p-type CuO-nanorod-based gas sensors. We synthesized the p-type CuO nanorods with breadth of about 30 nm and length of about 330 nm by a hydrothermal method using an as-deposited CuO seed layer prepared on a $Si/SiO_2$ substrate by the sputtering method. We fabricated polycrystalline CuO nanorod arrays at $80^{\circ}C$ under the hydrothermal condition of 1:1 morality ratio between copper nitrate trihydrate [$Cu(NO_2)_2{\cdot}3H_2O$] and hexamethylenetetramine ($C_6H_{12}N_4$). Structural characterizations revealed that we prepared the pure CuO nanorod array of a monoclinic crystalline structure without any obvious formation of secondary phase. It was found from the gas sensing measurements that the p-type CuO nanorod gas sensors exhibited a maximum sensitivity to NO gas in dry air at an operating temperature as low as $200^{\circ}C$. We also found that these CuO nanorod gas sensors showed reversible and reliable electrical response to NO gas at a range of operating temperatures. These results would indicate some potential applications of the p-type semiconductor CuO nanorods as promising sensing materials for gas sensors, including various types of p-n junction gas sensors.

Delayed Mode Quality Control of Argo Data and Its Verification in the Pacific Ocean (태평양 Argo 자료의 지연모드 품질관리 및 검증연구)

  • Yang, Joon-Yong;Kang, Seong-Yun;Go, Woo-Jin;Suh, Young-Sang;Seo, Jang-Won;Suk, Moon-Sik
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1353-1361
    • /
    • 2008
  • Quality control of Argo(Array for Real-time Geostrophic Oceanography) data is crucial by reason that salinity measurements are liable to experience some drift and offset due to biofouling, contamination of sensor and wash-out of biocide. The automated Argo real-time quality control has a limit of sorting data quality, so that WJO program is adopted as standardized method of Argo delayed mode quality control (DMQc) in the world that is a precise quality control method. We conducted DMQC on pressure, temperature and salinity measured by Argo floats in the Pacific Ocean including expert evaluation. Particularly, salinity data were corrected using WJO program. 4 salinity profiles of Argo delayed mode were compared with nearby in situ CTD data and other Argo data in deep layer where oceanographic conditions are stable in time and space. The differences of both salinities were lower than target accuracy of Argo. As compared with the difference of salinities before DMQC, those after DMQC decreased by 60-80 percent. Quality of delayed mode salinity data seemed to be improved correcting salinity data suggested by WJO program.

The design of a scintillation system based on SiPMs integrated with gain correction functionality

  • Lin, Zhenhua;Hautefeuille, Benoit;Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.164-169
    • /
    • 2020
  • Use of SiPM has been considered as an alternative to PMT, because of its compact size, low-operating voltage, non-sensitive to electromagnetic, low costs and so on. The main limitation for the use of SiPM is due to its small sensitive area compared to PMT that limits the light collection, and therefore the sensor energy resolution. In this article we studied the effect of increasing the number of SiPM by connecting them in parallel to increase the active detection area. This allowed us to compare the different energy resolution measurements. 137Cs has been selected as reference to study the energy resolution for 662 keV gamma-rays. Another investigation was to compare the minimum detectable gamma energy under various SiPM configurations. It has been found that the use of 4 SiPM arrays can greatly improve the energy resolution up to 4% than only one SiPM array, meanwhile use of more than 2 SiPM arrays does not increase the energy resolution significantly. Thus we can conclude that for a large area of cylindrical scintillator (3 × 3 inches), the use of SiPMs are limited to a certain number or certai active area depending on the commercial SiPMs, and its cost should be less than traditional PMT for the cost-effective and compact size considerations. It is well known that the gain of SiPM varies with temperature. In this article, we also calibrated gain to guarantee the same position of photoelectric peak in response of different temperatures.

Simultaneous Determination of Three Compounds in Ejung Tang by HPLC-DAD and LC-ESI-MS (HPLC를 이용한 이중탕 중 3종 활성성분의 동시분석법 확립)

  • Lee, Bo-Hyoung;Ma, Jin-Yeul;Weon, Jin-Bae;Yang, Hye-Jin;Yun, Bo-Ra;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • An accurate and sensitive analysis method was established for simultaneous determination of three bioactive compounds (glycyrrhizin, 6-gingerol and ginsenoside Rg3) in the Ejung Tang with high-performance liquid chromatography (HPLC)-photodiode array detection (DAD)-electrospray ionization (ESI)-Mass spectrometry (MS). The optimizing chromatographic separations a were acquired by an $C_{18}$ column ($5{\mu}m$, $4.6I.D{\times}250mm$, SHISHEDO) using gradient elution with water comprising 0.1% TFA(trifluoroacetic acid) and acetonitrile at a performing temperature of $35^{\circ}C$. Flow rate was 1.0 ml/min. A detection UV wavelength set at 205 nm and 250 nm. The three compounds were identified by electrospray ionization mass spectrometry. All calibration curves indicated great linear regression within test ranges ($R^2>0.9997$). The established method provided acceptable precision and accuracy. The relative standard deviations (RSDs) of intra-day and inter-day were less than 2.00% and 3.00%, respectively. The recoveries were found to range from 94.49 to 101.10% for the three compounds analyzed. These results showed that this method was effective and reliable for quality control of Eiung-Tang.

Simultaneous Analysis of Bioactive Metabolites from Rehmannia glutinosa by HPLC-DAD-MS/MS

  • Won, Tae-Hyung;Ryu, Sung-Kwang;Kang, Sam-Sik;Shin, Jong-Heon
    • Natural Product Sciences
    • /
    • v.16 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) and electrospray ionization mass spectrometry (ESI-MS) was established for the simultaneous determination of five representative metabolites of the iridoid and phenolic classes from Rehmannia glutinosa. The optimal chromatographic conditions were obtained on an ODS column (5 mm, $4.6{\times}250\;mm$) with the column temperature at $25^{\circ}C$. The mobile phase was composed of water and acetonitrile using a gradient elution with the flow rate 0.3 mL/min. Detection wavelength was set at 205 nm. All calibration curves showed good linear regression ($r^2$ > 0.997) within test ranges. Limits of detection (LOD) and quantitation (LOQ) values were lower than 0.123 and $0.373\;{\mu}g/mL$, respectively. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.09 - 0.76% and 0.16 - 1.41%, respectively, and the overall recoveries of 99.03 - 102.67% for all of the compounds analyzed. In addition, effectiveness of diverse extraction methods was compared to each other for the development of standard analytic method. The verified method was successfully applied to the quantitative determination of five representative metabolites in twenty-one commercial Rehmannia glutinosa samples from different markets in Korea and China. The analytical results showed that the contents of the five analytes vary significantly with sources.

Pixel-level Current Mirroring Injection with 2-step Bias-current Suppression for 2-D Microbolometer FPAs (이차원 마이크로볼로미터 FPA를 위한 이 단계 바이어스 전류 억제 방식을 갖는 픽셀 단위의 전류 미러 신호취득 회로)

  • Hwang, Chi Ho;Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.36-43
    • /
    • 2015
  • A pixel-level readout circuit is studied for 2-dimensional microbolometer focal plane arrays (FPAs). A current mirroring injection (CMI) input circuit with 2-step current-mode bias suppression is proposed for a pixel-level architecture with high responsivity and long integration time. The proposed circuit has been designed using a $0.35-{\mu}m$ 2-poly 4-metal CMOS process for a $320{\times}240$ microbolometer array with a pixel size of $50{\mu}m{\times}50{\mu}m$. The proposed 2-step bias-current suppression has sufficiently low calibration error with wide calibration range, and the calibration range and error can be easily optimized by controlling some design parameters. Due to high responsivity and a long integration time of more than 1 ms, the noise equivalent temperature difference (NETD) of the proposed circuit can be improved to 26 mK, which is much better than that of the conventional circuits, 67 mK.

Application of hydrogeological and geophysical methods to delineate leakage pathways in an earth fill dam (사력댐 누수경로 파악을 위한 수리지질과 지구물리 방법의 적용)

  • Song Sung-Ho;Song Yoonho;Kwon Byung-Doo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.92-96
    • /
    • 2005
  • Comprehensive field surveys, including various hydrogeological and geophysical methods, were carried out to appraise the applicability of those methods to a leakage problem at the Sandong earth fill dam in southwestern Korea. The methods applied in the fold site were tracer tests, monitoring of drawdown and leakage with discharge of reservoir water, electrical resistivity surveys using the dipole-dipole array, self-potential (SP), and temperature logging methods. The leakage pattern in the reservoir wall was demonstrated by hydrogeological methods and was further clarified by the geophysical surveys. Leakage turned out to be through the right abutment of the reservoir wall. In this study, we conformed that the electrical resistivity method is effective in detecting the zones favorable to leakage, and SP methods are useful for delineating the leakage pathways themselves, because leaks generate strong streaming-potential anomalies.