• Title/Summary/Keyword: Arousal Control

Search Result 58, Processing Time 0.026 seconds

Evaluation of the Criteria for the Control of Arousal Level and Effect of Warning Signal (각성도 제어를 위한 평가기준의 설정 및 경고음의 효과분석)

  • 김연호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.79-86
    • /
    • 1997
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds to the change of arousal level was detected by the three elctrode constant current method and separated into two components(SIR, SIL). Relationship between Nz, IRI and arousal level was studied and criteria of arousal level control was decided by the sleep study. Measured data with and without warning signal were compared and analyzed.

  • PDF

Analysis of arousal effects of warning sound and aroma using EDA (EDA를 이용한 경고음과 향기자극의 각성효과 분석)

  • Kim, Youn-Ho;Ko, Han-Woo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.19-22
    • /
    • 1997
  • This paper studies the arousal effects of aroma and warning sound using EDA(Electrodermal Activity:EDA), Aroma stimulus started at Nz value over 1.2. Warning sound was prepared according to the arousal evaluation and control criteria. As a result, the warning sound could be controlled the arousal level in all the mKSS state. Aroma stimulus was able to prevent drowsy more than warning sound in the mKSS 3 state(the first stage of drowsiness). Therefor, aroma stimulus was can be used for arousal control at that state. Futhermore, arousal control was shown to be more effective with presentation of both aroma and warning sounds than each presentation.

  • PDF

Compensation of Arousal Level Criteria by a Modified KSS Scale (수정된 KSS 측도에 의한 각성도 평가기준 보상법)

  • 고한우;김연호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.477-484
    • /
    • 1997
  • In this paper, we proposed the compensation method to evaluate arousal level in different initial arousal states. Arousal level was measured by the relationship between IRI and Nz. Since Nz is affected by BI which is directly proportional to initial arousal state of subjects, the arousal level is underestimated To overcome this problem, we proposed the compensation method using modified Karolinska sleepiness scale, and determined compensation coefficients derived from this scale with five arousal levels. Applying these coefficients to portable arousal monitoring system, the proposed method in this paper could be useful for real-time evaluation and control of arousal level. As a result the developed system can detect and control the arousal state from initial drowsing sate.

  • PDF

Evaluation of arousal level by EDA and fuzzy inference (피부전기 활동과 fuzzy추론에 의한 각성도의 평가)

  • Kim, Yeon-Ho;Ko, Han-Woo;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1856-1859
    • /
    • 1997
  • This paper describes the arousal measurement and the control system using fuzzy logic to prevent drowsy driving. Sugeno's method was used for fuzzy inference in this study. Membership function and rule base were determined form the modfied arousal level criteria. The output of fuzzy inference tracked well the change of subject's arousal level. When IRI(Inter-SIR interval) was under the 60sec, maximum output of three step warning method was medium sound, but that of fuzzy logic system was changed from medium to big. Furthermore, the output of the fuzzy inference was highly correlated with $N_{z}$(r=0.99). Therefore, the fuzzy inference method for evaluation and the control of arousal will be more effective at real driving sityation than three step warning method.ning method.

  • PDF

Portable arousal measurement and analysis system (휴대형 각성도 측정 및 분석 시스템)

  • Ko, H.W.;Kim, Y.H.;Kim, C.J.;Lee, G.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.60-64
    • /
    • 1996
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds the change of arousal level was detected by the three electrode constant current method and separated into two components (SIR, SIL). Relationship between Nz, IRI and arousal level was studied and Criteria of arousal level control was decided by the sleep study.

  • PDF

Portable arousal control system using electrodermal activities (피부 전기활동을 이용한 휴대형 각성도 측정 및 제어 시스템)

  • Ko, Han-Woo;Lee, Woan-Kyu;Kim, Youn-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.55-64
    • /
    • 1996
  • To control arousal level using physiological index, electrodermal activity signal was detected and separated into skin impedance level and response. Arousal state decision and control algorithm was studied to implement and evaluate real time portable arousal control system. The implemented system can detect and control arousal state from initial drowsy state. This system will be applicable to the evaluation of the effect of warning signal, driver's drowsy detecting system, and sleep study.

  • PDF

Evaluation of Arousal Level to Prevent Drowsy Driving by Fuzzy Inference (졸음운전 방지를 위한 fuzzy 추론에 의한 각성도의 평가)

  • Kim, Y. H.;Ko, H. W.;Lyou, J.
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.491-498
    • /
    • 1997
  • This paper describes the arousal measurement and control system using fuzzy logic to prevent drowsy driving. Sugeno's method was used for fuzzy inference in this study. Arousal evaluation and control criteria were modified from result of Nz-IRI analysis depending on arousal sate. Membership function and rule base of fuzzy inference were determined from the modified arousal level criteria When lRl (Inter-SIR Interval) was shorter than 60sec, outputs of both methods were changed from small to big, but output of three step warning method was same level until the next warning range. Since output of fuzzy inference tracked well the change of subject's arousal level, problems of three step warning method could be overcome by fuzzy inference method Furthermore, the output of the fuzzy inference was highly correlated with Nz(r = 0.99). Therefore, the fuzzy inference method for evaluation and the control of arousal will be more effective at real driving situation than three step warning method.

  • PDF

Comparison and The Evaluation of Criteria for Arousal Level Control (SIC에 의한 각성도 제어를 위한 평가기준의 설정 및 비교)

  • Ko, H.W.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.372-376
    • /
    • 1996
  • This paper describes the criterias to evaluate arousal states of subject and these are applied to contort arousal level. Correction factor was introdued to compensate under or over evaluated Nz due to the different initial basal skin impedance. These criteria and correction factor were worked well to increase the arousal level.

  • PDF

The Literature Review on the Relation between the Modulation of Arousal and the Suck/Swallow/Breathe(SSB) Synchrony (각성조절과 빨기/삼키기/숨쉬기의 조화(Suck/Swallow/Breathe Synchrony)와의 연관성에 관한 고찰)

  • Kim, In-Sun;Lee, Ji-Young;Hwang, Jee-Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.1 no.1
    • /
    • pp.61-72
    • /
    • 2003
  • The suck/swallow/breathe(SSB) synchrony, serving as the earlist primary motor mechanism, is the rhythmical, coordinated pattern of sucking, swallowing and breathing. The development of an intact SSB is an important precursor for further sensorimotor and cognitive development including speech and language development, state regulation, postural control, feeding, eye/hand coordination and social/emotional development. Arousal means a neurological mechanism for preparing one's body to orienting stimulus. Its levels are regulated with an interaction of the reticular formation, the limbic system, the hypothalamus and the autonomic nervous system. General strategies such as blowing, sucking, chewing, munching and licking to effectively modulate arousal state are related to SSB. The SSB synchrony is an important treatment principle for children with sensory integration disorder and problems with the modulation of arousal. The purpose of this article is to review concepts of SSB synchrony and the underlying relation between the modulation of arousal and SSB synchrony.

  • PDF

A Study Concerning Analysis of Arousal State of locomotive Engineering During Operating Train (열차 운행 중인 기관사의 각성상태 분석에 관한 연구)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Lee, Jae-Ho;Lim, Min-Gyu;Baek, Jong-Hyen;Song, Yong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.891-898
    • /
    • 2012
  • The study for the passenger's comfortableness of vehicles and the arousal of car drivers has been done widely. On the other hand, there are few studies for the locomotive engineers. Human error means that the mistakes made by human, recently it receives attention in the field of safety engineering and human engineering. Comparing the operating condition of train with car, because of the simplification of the visual stimulus, the arousal level on the train goes down easily. The arousal level down makes judgement down, the accident risk from human error is getting bigger. In this study, we measured bio-signals(ECG, EDA, PPG, respiration and EEG) from 6 locomotive engineers to evaluate their arousal state while they operated the train. Also we recorded the 3 axes acceleration signal showing the vibration state of train. Also, the existence of tunnels were simultaneously measured. At the station section where the train speed goes down, the size of vector's sum decreases because of reduced vibration. Beta component in EEG tends to increase at the entering point of each station and tunnel. It is due to the arousal reaction and tension growth. The mean SCR(skin conductance response) was more increased in neutral section. As the button control movement (body movement) increases in the neutral section, it is appeared that SCR increase. RR interval tends to gradually increase during train operation for 1 hour 40 minutes. However, It tends to sharply decrease at the stop station because strong concentration needed to stop train on the exact point. The engineer's arousal reaction can be checked through analysing the bio-signal change during train operation. Therefore, if this analysing result is adopted to the sleepiness prevention caution system, it will be useful for the safety train operation.