• Title/Summary/Keyword: Arm structure

Search Result 367, Processing Time 0.036 seconds

The Effect of Internal Chills on the Solidified Structure and Chemical Segregation (응고조직 및 성분편석에 미치는 내부냉금의 효과)

  • Kim, Myeong-Han;Jo, Hyeon-Nam;Kim, Jeong-Gyeom;Jo, Hyeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.883-889
    • /
    • 1999
  • The pure Al or-(1,2,3wt%)Cu alloy internal chill with 4,6,8,12 and 15mm ø, respectively, was inserted at the center of a graphite mold with the size of 95mm ø$\times$200mm H. The molten metal with the same composition as the internal chill was poured into the mold at the pouring temperature of $750^{\circ}C$ and the cooling rates, solidified structures and chemical segregation were analyzed. The results represented that there was remarkable increased in cooling rate as well as decrease in grain size, secondary dendrite arm spacing and chemical segregation as the ratio of ingot to internal chill diameter was increased to 8. However there was a considerable drop of the internal chill effect when this ratio exceeded 8, resulting from incomplete melting of internal chills. The optimum ratio for the maximum internal chill effect of pure Al and-(1,2,3wt%)Cu allolys was 8 at the given pouring temperature.

  • PDF

Controlled Synthesis of Hexagonal Boron Nitride on Cu Foil Using Chemical Vapor Deposition

  • Han, Jaehyun;Lee, Jun-Young;Kwon, Heemin;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.630-630
    • /
    • 2013
  • Recently, atomically smooth hexagonal boron nitride(h-BN) known as a white graphene has drawn great attention since the discovery of graphene. h-BN is a III-V compound and has a honeycomb structure very similar to graphene with smaller lattice mismatch. Because of strong covalent sp2bonds like graphene, h-BN provides a high thermal conductivity and mechanical strength as well as chemical stability of h-BN superior to graphene. While graphene has a high electrical conductivity, h-BN has a highly dielectric property as an insulator with optical band gap up to 6eV. Similar to the graphene, h-BN can be applied to a variety of field, such as gate dielectric layers/substrate, ultraviolet emitter, transparent membrane, and protective coatings. However, up until recently, obtaining and controlling good quality monolayer h-BN layers have been too difficult and challenging. In this work, we investigate the controlled synthesis of h-BN layers according to the growth condition, time, temperature, and gas partial pressure. h-BN is obtained by using chemical vapor deposition on Cu foil with ammonia borane (BH3NH3) as a source for h-BN. Scanning Transmission Electron Microscopy (STEM, JEOL-JEM-ARM200F) is used for imaging and structural analysis of h-BN layer. Sample's surface morphology is characterized by Field emission scanning electron microscopy (SEM, JEOL JSM-7100F). h-BN is analyzed by Raman spectroscopy (HORIBA, ARAMIS) and its topographic variations by Atomic force microscopy (AFM, Park Systems XE-100).

  • PDF

Anatomical Study on the Heart Meridian Muscle in Human

  • Park Kyoung-Sik
    • The Journal of Korean Medicine
    • /
    • v.26 no.1 s.61
    • /
    • pp.11-17
    • /
    • 2005
  • This study was carried out to identify the components of the human heart meridian muscle, the regional muscle group being divided into outer, middle, and inner layers. The inner parts of the body surface were opened widely to demonstrate muscles, nerves, blood vessels and to expose the inner structure of the heart meridian muscle in the order of layers. We obtained the following results; $\cdot$ The heart meridian muscle is composed of muscles, nerves and blood vessels. $\cdot$ In human anatomy, the difference between terms is present (that is, between nerves or blood vessels which control the meridian muscle and those which pass near by). $\cdot$ The inner composition of the heart meridian muscle in the human arm is as follows: 1) Muscle H-l: latissimus dorsi muscle tendon, teres major muscle, coracobrachialis muscle H-2: biceps brachialis muscle, triceps brachialis muscle, brachialis muscle H-3: pronator teres muscle and brachialis muscle H-4: palmar carpal ligament and flexor ulnaris tendon H-5: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficialis tendon, flexor digitorum profundus tendon H-6: palmar carpal ligament & flexor retinaculum, flexor carpi ulnaris tendon H-7: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficial is tendon, flexor digitorum profundus tendon H-8: palmar aponeurosis, 4th lumbrical muscle, dorsal & palmar interrosseous muscle H-9: dorsal fascia, radiad of extensor digiti minimi tendon & extensor digitorum tendon 2) Blood vessel H-1: axillary artery, posterior circumflex humeral artery H-2: basilic vein, brachial artery H-3: basilic vein, inferior ulnar collateral artery, brachial artery H-4: ulnar artery H-5: ulnar artery H-6: ulnar artery H-7: ulnar artery H-8: palmar digital artery H-9: dorsal digital vein, the dorsal branch of palmar digital artery 3) Nerve H-1: medial antebrachial cutaneous nerve, median n., ulnar n., radial n., musculocutaneous n., axillary nerve H-2: median nerve, ulnar n., medial antebrachial cutaneous n., the branch of muscular cutaneous nerve H-3: median nerve, medial antebrachial cutaneous nerve H-4: medial antebrachial cutaneous nerve, ulnar nerve H-5: ulnar nerve H-6: ulnar nerve H-7: ulnar nerve H-8: superficial branch of ulnar nerve H-9: dorsal digital branch of ulnar nerve.

  • PDF

Management for Raw Surface of Forehead Flap Using Artificial Collagen Membrane (이마피판에서 피판 노출면의 인조 콜라겐막을 이용한 관리)

  • Kim, Da-Arm;Oh, Sang-Ha;Seo, Young Joon;Yang, Ho Jik;Jung, Sung Won
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.46-49
    • /
    • 2012
  • Purpose: The forehead flap is the workhorse in nasal reconstruction, which provides a similar skin color, texture, structure, and reliability. There are some disadvantages, including donor site morbidities, 2- or 3-stage operations, and postoperative management after initial flap transfer. Furthermore, there has been little attention to the exposed raw surface wound, after the first stage of an operation. This article describes the authors' modification to overcome this problem, using artificial collagen membrane. Methods: An Artificial collagen membrane is composed of an outer silicone membrane and an inner collagen layer. After a forehead flap elevation, the expected raw surface was covered by an artificial collagen membrane with 5-0 nylon suture. A simple dressing, which had been applied to the site, was changed every 2 or 3 days in an outpatient unit. At 3 weeks postprocedure, a second stage operation was performed. Results: With biosynthetic protection of the raw surface, there were no wound problems, such as infection or flap loss. Thus, the patient was satisfied due to an effortless management of the wound and a reduction in pain. Conclusion: The application of an artificial collagen membrane to the raw under-surface of the flap could be a comfortable and a protective choice for this procedure.

Design of an Economic Service Robot Hand Based on Biomimetics and TRIZ (생체 모방학과 트리즈를 이용한 보급형 서비스 로봇 핸드의 설계)

  • Ko, Hun-Keon;Cho, Chang-Hee;Kim, Kwon-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1741-1747
    • /
    • 2010
  • This work presents a study on the design of an economic service robot hand for tele-presence manipulators. The conceptual design of new robot hand is derived from biomimetics approach. Guided by the analysis of human arm' musculoskeletal structure, the fingers are actuated by cables and actuators in the forearm. High tension in the cables is achieved by screw-nut mechanism driven by DC motors. A set of combination springs is incorporated in each of the screw-nut mechanism for easy control of gripping force. The first prototype revealed difficulties with finger control and coupling problem between gripping force and wrist movement. The solutions to these problems have been derived from the contradiction analysis of TRIZ. The second design has been verified by tests on various objects with different weight and shape for full range of wrist motion.

Thermodynamic Studies on Complexes for Dibenzo-16-crown-5 Sulfur Lariat Ether with Metal Ions (Dibenzo-16-crown-5 Lariat Ether와 금속이온과의 착물형성에 관한 연구)

  • Cho, Moon Hwan;Lee, Sang Chul;Cho, Jae Hoon;Kim, Eung Tae;Rhee, Chang Hwan;Choi, Young Sup;Lee, Jong Chan
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.443-448
    • /
    • 1998
  • The thermodynamic parameters for the interaction of metal ions with dibenzo-16-crown-5 and its derivatives have been determined by solution calorimetry in methanol at 25$^{\circ}C$. Thermodynamic properties of log K, ${\Delta}H$, and $T{\Delta}S$ have been determined for the complexation of metal cations by dibenzo-16-crown-5 and its derivatives. Dibenzo-16-crown-5 and its derivatives have been studied as metal cations carrier in bulk liquid membrane (BLM) and supported liquid membrane (SLM) system. $Ag^+$ has been much more transported using dibenzo-16-crown-5 derivatives as carriers and several other metal cations have been small transported using carrier in BLM and SLM system. Ligand structure, the length of side arm, donor atom, stability constant, and carrier concentration are also important parameters in the transport of cations.

  • PDF

Eccentric Axial Loading Test for Concrete-Encased L-section Columns using 800MPa Steel and 100MPa Concrete (800MPa 강재 및 100MPa 콘크리트를 적용한 ㄱ형 강재 매입형 합성기둥의 편심압축실험)

  • Kim, Chang-Su;Park, Hong Gun;Lee, Ho Jun;Choi, In Rak
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.209-222
    • /
    • 2013
  • Eccentric axial loading test was performed for concrete-encased columns using 800MPa steel and 100MPa concrete. To maximize the contribution of the high-strength steel, L-shaped steel sections were placed at four corners, and connected to each other by lattices, links, or battens. Compared to a H-section of the same area, the moment-arm and strain of the L-sections are increased. Also, the corner L-sections provide good lateral confinement to concrete core. The test results showed that the peak strength and effective flexural stiffness of the L-section columns were increased by more than 1.4 times those of the H-section column.

A Study on the Control of Cast Microstructure in the Aluminum Casting/Forging Process (알루미늄 주조/단조 공정에서 주조조직 제어에 관한 연구)

  • Bae, Won-Byong;Kang, Chung-Yun;Lee, Young-Seok;Lee, Sung-Mo;Hong, Chang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.9
    • /
    • pp.41-47
    • /
    • 1999
  • The scale of dendritic structure of a cast preform plays a key role in determining the mechanical properties of cast/forged products. In this study, casting experiments are carried out to reduce dendrite arm spacing (DAS) to smaller than 20 ${\mu}$m by increasing cooling rate of the mold and then to spheriodize dendritic structures by addition of alloying elements such as Zr and Ti-B. From the casting experiments, appropriate casting conditions for producing the cast preform of a motorcycle connecting rod are obtained. To obtain fine microstructures of the cast preform, mold temperature must set to be low whilst cooling rate being high. When cooling rate is 10 $^{\circ}C$/s, the size of DAS is 17.4 ${\mu}$m. And the degree of spheriodization of a grain in the cast preform is described by aspect ratio, which is defined as the ratio of major and minor radii of an elliptical grain. When 0.5% Zr and 0.24 % Ti+B are added to the molten aluminum alloy, the best aspect-ratio 0.75 is obtained. After forging the cast preform of a motorcycle connecting rod, the microstructure and mechanical properties of the cast preform are compared with those of the cast/forged product. Cast/forged products are superior in microstructure and in mechanical properties such as ultimate strength, elongation, and hardness.

  • PDF

Latissimus Dorsi Transfer in Brachial Plexus Injury for the Elbow Flexion (상완 신경총 손상후 주관절 근력 회복을 위한 광배근 전이술)

  • Han, Chung-Soo;Chung, Duke-Whan;Soh, Jae-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1998
  • The incidence of brachial plexus injury is increasing because of the development of motor vehicle but the the results of treatment was reported poor due to its complex anatomical structure and changes of function and sensory during the recovery after trauma. But the results of treatment has been improved by the recently introduced high sensitive diagnostic method that can evaluate accurately the site and extent of the injury and treatment method. Restoration of the elbow flexion is the most important goal of treatment after brachial plexus injury and nerve graft, neurotization and muscle transfer were used for methods of treatment. From December 1992 to May 1994, the author performed 6 cases of latissimus dorsi transfer at the same side for the improvement of elbow flexion in the patients of brachial plexus injury. There were 5 cases of male, one case of female and average age was 22 years old. The causes of injury were traffic accident in 3 cases, gun shot injury, falldown and birth injury in each one case and in all cases, the type of injury were upper arm type. The average follow up period were 1 year 5 months ranging from 12 months to 4 years 5 months. In all cases, active elbow flexion was impossible before operation and average muscle power was grade I. We analysed the active range of motion, muscle power and the functional results. At the last follow up, range of active elbow flexion was average $124^{\circ}$ and flexion contracture was average 11 degrees and the average of muscle power was grade IV. In the functional analysis, there were two cases of excellent, three cases of good and 1 case of fair. There was no complications including wound infection, vascular compromise and donor site problem. The results of latissimus dorsi transfer for improvement elbow flexion in the patients of brachial plexus injury is one of the useful mettled for the restoration of elbow flexion.

  • PDF

Gold Shell Nanocluster Networks in Designing Four-Branch (1×4) Y-Shape Optical Power Splitters

  • Ahmadivand, Arash;Golmohammadi, Saeed
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.274-282
    • /
    • 2014
  • In this study, closely spaced Au nanoparticles which are arranged in nanocluster (heptamer) configurations have been employed to design efficient plasmonic subwavelength devices to function at the telecommunication spectrum (${\lambda}$~1550 nm). Utilizing two kinds of nanoparticles, the optical properties of heptamer clusters composed of Au rod and shell particles that are oriented in triphenylene molecular fashion have been investigated numerically, and the cross-sectional profiles of the scattering and absorption of the optical power have been calculated based on a finite-difference time-domain (FDTD) method. Plasmon hybridization theory has been utilized as a theoretical approach to characterize the features and properties of the adjacent and mutual heptamer clusters. Using these given nanostructures, we designed a complex four-branch ($1{\times}4$) Y-shape splitter that is able to work at the near infrared region (NIR). This splitter divides and transmits the magnetic plasmon mode along the mutual heptamers arrays. Besides, as an important and crucial parameter, we studied the impact of arm spacing (offset distance) on the guiding and dividing of the magnetic plasmon resonance propagation and by calculating the ratio of transported power in both nanorod and nanoshell-based structures. Finally, we have presented the optimal structure, that is the four-branch Y-splitter based on shell heptamers which yields the power ratio of 23.9% at each branch, 4.4 ${\mu}m$ decaying length, and 1450 nm offset distance. These results pave the way toward the use of nanoparticles clusters in molecular fashions in designing various efficient devices that are able to be efficient at NIR.