Corrosion of rebar in carbon fiber reinforced polymer bonded reinforced concrete

  • Bahekar, Prasad V.;Gadve, Sangeeta S.
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.247-255
    • /
    • 2019
  • Several reinforced concrete structures that get deteriorated by rebar corrosion are retrofitted using Carbon Fiber Reinforced Polymer (CFRP). When rebar comes in direct contact with CFRP, rebar may corrode, as iron is more active than carbon. Progression of corrosion of rebar in strengthened RC structures has been carried out when rebar comes in direct contact with CFRP. The experimentation is carried out in two phases. In phase I, corrosion of bare steel bar is monitored by making its contact with CFRP. In phase II, concrete specimens with surface bonded CFRP were casted and subjected to the realistic exposure conditions keeping direct contact between rebar and CFRP. Progression of corrosion has been monitored by various parameters: Half-cell potential, Tafel extrapolation and Linear Polarisation Resistance. On termination of exposure, to find residual bond stress between rebar and concrete, pull-out test was performed. Rebar in contact with CFRP has shown substantially higher corrosion. The level of corrosion will be more with more area of contact.

Approaches to Reduce the Contact Resistance by the Formation of Covalent Contacts in Graphene Thin Film Transistors

  • Na, Youngeun;Han, Jaehyun;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.26 no.4
    • /
    • pp.55-61
    • /
    • 2017
  • Graphene, with a carrier mobility achieving up to $140,000cm^2/Vs$ at room temperature, makes it an ideal material for application in semiconductor devices. However, when the metal comes in contact with the graphene sheet, an energy barrier forms at the metal-graphene interface, resulting in a drastic reduction of the carrier mobility of graphene. In this review, the various methods of forming metal-graphene covalent contacts to lower the contact resistance are discussed. Furthermore, the graphene sheet in the area of metal contact can be cut in certain patterns, also discussed in this review, which provides a more efficient approach to forming covalent contacts, ultimately reducing the contact resistance for the realization of high-performance graphene devices.

The effect of Rhemanniae radix extract on allergic contact dermatitis on Mice induced by DNCB (생지황(生地黃) 추출물(抽出物)이 DNCB로 유발(誘發)된 생쥐의 Allergy성(性) 접촉피부염(接觸皮膚炎)에 미치는 영향(影響))

  • Shin Gwang-Sik;Son Jeong-Suk;Kim Dong-Eun;Jeon Won-Jun;Jeong Seung-Hyeon;Sin Gil-Jo;Lee Won-Cheol
    • Herbal Formula Science
    • /
    • v.8 no.1
    • /
    • pp.257-279
    • /
    • 2000
  • Allergic contact dermatitis is a common skin disease resulting from specific immunologic to topically applied various allergen. After Dinitrochlorobenzene (DNCB) secondary sensitization, the ICR mice administered Rhemanniae radix extract (RRE) was observed to ascerstain the effect of RRE on allergic contact dermatitis. Purpose of this study was to investigate contact hypersensitivity assay, abdominal skin morphologic changes. Including mast cells and cell-surface glycoconjugates. The change of interleukin 2 (IL-2) receptor (CD25R). ICAM in abdominal skin, lymph node of inguinal region, and electro microscope-morphologic changes of abdominal skin. The results of this study were as follows: 1. The contact hypersensitivity assay, the ear swelling in the RRE had lesser probability than in the ACD Group. 2. In the general morphologic change of skin, hyperplasia of keratinocytes, distribution of vasculogenesis and epidermal lymphocytes infiltration were decreased in the RRE group compared with the ACD group. In epidermal basal layer and prickle layer, cell damage was decreased in the RRE group compared with the group painted with ACD. 3. MasT-cell in dermis was decreased in the RRE group compared with the group painted with DNCB. 4. Distribution of interlukin-2 Receptior positive cell and ICAM positive cell in dermis was decreased in the RRE Group compared with the ACD group. 5. Distribution of helper T-lymphocyte and cytotoxic T-lymphocite in inguinal nodes was decreased in the RRE group, and was observed well in paracortical area and cortical cord. 6. Distribution of apoptotic cell was appeared in the RRE group compared with the ACD group, in skin, dermis. in inguinal nodes, paracortical area observed well. With above results, the restarint of immunosuppression occuring in Allergic contact dermatitis is resulted in the slow progress the effect of Allergic contact dermatitis, and it is thought that ithis fact has a series of relation with apoptosis.

  • PDF

Fatigue Life Analysis of Rolling Contact Model Considering Stress Gradient Effect (응력 구배 효과를 고려한 구름 접촉 모델의 피로수명해석)

  • Cho, InJe;Yu, YongHun;Lee, Bora;Cho, YongJoo
    • Tribology and Lubricants
    • /
    • v.31 no.6
    • /
    • pp.272-280
    • /
    • 2015
  • Recently, Luu suggested fatigue life equation that uses every term of the Crossland equation with stress gradient effect. Luu’s model, however, has a limit of being unable to coverage small radii that are less than a specified length. Furthermore, rolling model has a very small contact area compared to the rolling element size, and fatigue failure occurs on the small radius such as surface asperity by cyclic loading. Therefore, it is necessary to modify fatigue life equation in order to enable fatigue analysis for a small radius. In this paper, the fatigue life considering a stress gradient effect in rolling contact was obtained using Luu’s modified equation. Fatigue analysis was performed to study the effect of stress gradient on the fatigue life using newly adopted equation and to compare the results with pervious models. In order to do this, a series of simulation such as surface stress analysis, subsurface stress analysis, and fatigue analysis are conducted for two rolling balls of same size that contact each other. Through such a series of processes, the fatigue life can be calculated and equation that is proposed in this paper evaluates the fatigue life in case the contact area is small.

Iodine Doping of Pentacene and its Electrical Properties

  • Rahim, Abdur;Lee, Young-Kyu;Lee, Chi-Young;Lee, Jae-Gab
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.238.2-238.2
    • /
    • 2011
  • Organic thin film transistors (OTFTs) have been attracting considerable attention because of their potential use in low-cost, large area, electronic devices such as flexible displays, biochemical sensors, and smart cards. In past several years, gold/pentacene has been frequently used in OTFTs because of the high mobility of pentacene and the high work function of gold. To improve the performance of the OTFTs contact area doping of pentacene with p-doping materials are well known. In this work we demonstrated selectively contact area doping of pentacene with Iodine vapor. For effective doping elevated pentacene layer under the source-drain area was deposited and exposed to Iodine vapor. We got better electrical performance for elevated pentacene structure rather than planer structure with relatively high field-effect mobility.

  • PDF

A Method of Contact Pressure Analysis between Half-space and Plate (탄성지반과 판의 접촉압력해석에 관한 연구)

  • Cho, Hyun Yung;Cheung, Jin Hwan;Kim, Seong Do;Han, Choong Mok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 1992
  • A method analizing contact pressure between plate and elastic half space is presented by using F.E.M. With the method, the pressure intensities at surface nodes of half space cae be directly calculated by using flexibility matrix of half space. The method is originally presented by Y.K. Cheung et al.(3) Insted of Y.K. Cheung's method, which use a conception of equi-contact pressure area around each surface nodes of half space in the noded rectanqular element area. We use the equi-contact pressure area around the Gaussian integration points of half space surface in the noded isoparametric element area. Numarical examples are presented and compared with other's studies.

  • PDF

Experimental Study of Thermal-mechanical Influence on the Hydraulic Properties of Rock (암반의 수리인자에 미치는 열적.역학적 영향에 대한 실험적 검증)

  • 전석원;홍창우;이주현;강주명;배대석
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.59-67
    • /
    • 2003
  • In this study, the change in hydraulic conductivity according to the changes in the contact area, aperture, confining pressure and temperature was observed to improve the reliability of the analysis of underground water flow. Also, the mechanical and thermal properties of domestic crystalline rocks in a great depth were obtained. It was found that the averaged intial aperture ranged from 544.33${\mu}{\textrm}{m}$ to 898.62${\mu}{\textrm}{m}$ and it followed a log-normal distribution. The hydraulic conductivity decreased with the increase of normal stress on the fracture surface and the hydraulic conductivity decreased as temperature increased. The change in hydraulic conductivity was strongly correlated with the change in contact area. It was verified by experiments that hydraulic conductivity was inversely proportional to the contact area. The measured mechanical and thermal properties were very close to the existing typical properties of domestic granites.

Posterior dental compensation and occlusal function in adults with different sagittal skeletal malocclusions

  • Hwang, Soonshin;Choi, Yoon Jeong;Jung, Sooin;Kim, Sujin;Chung, Chooryung J.;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.50 no.2
    • /
    • pp.98-107
    • /
    • 2020
  • Objective: The aim of this study was to compare posterior tooth inclinations, occlusal force, and contact area of adults with different sagittal malocclusions. Methods: Transverse skeletal parameters and posterior tooth inclinations were evaluated using cone beam computed tomography images, and occlusal force as well as contact area were assessed using pressure-sensitive films in 124 normodivergent adults. A linear mixed model was used to cluster posterior teeth into maxillary premolar, maxillary molar, mandibular premolar, and mandibular molar groups. Differences among Class I, II, and III groups were compared using an analysis of variance test and least significant difference post-hoc test. Correlations of posterior dental inclinations to occlusal function were analyzed using Pearson's correlation analysis. Results: In male subjects, maxillary premolars and molars had the smallest inclinations in the Class II group while maxillary molars had the greatest inclinations in the Class III group. In female subjects, maxillary molars had the smallest inclinations in the Class II group, while maxillary premolars and molars had the greatest inclinations in the Class III group. Occlusal force and contact area were not significantly different among Class I, II, and III groups. Conclusions: Premolar and molar inclinations showed compensatory inclinations to overcome anteroposterior skeletal discrepancy in the Class II and III groups; however, their occlusal force and contact area were similar to those of Class I group. In subjects with normodivergent facial patterns, although posterior tooth inclinations may vary, difference in occlusal function may be clinically insignificant in adults with Class I, II, and III malocclusions.

Analysis of Foot Pressure according to the Work Postures on Fire Fighters (소방대원들의 작업자세에 따른 족저압력 분석)

  • Son, Sung Min;Roh, Hyo Lyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.88-94
    • /
    • 2013
  • The purpose of this study is to find out the difference of foot pressure according to the firefighter's work postures for providing the basic information to prevent Musculoskeletal disorders. This study was conducted by 9 male firefighters. Work postures were selected for rescuee handling, fire hose and hydraulic rescue equipment work postures. These were divided into 3 position, "High", "Middle" and the postures of taking out and letting down hydraulic rescue equipment were analyzed as starting point and end point respectively. Foot Pressure was used to analyze contact area, peak pressure, and maximum force in terms of work postures, and compared between fire hose and hydraulic rescue equipment work postures. The results of foot pressure are as follows. According to the results of rescuee handling work postures, one person handling posture showed wide contact area and foot pressure showed the highest at right foot. Accoridng to the (High), (Middle), (Low) postures of fire hose, the results didn't show the difference among the contact area, peak pressure and maximum force. As the results of hydraulic rescue equipment work postures, (Low) postures showed the highest in terms of the right foot of contact area, peak pressure and maximum force and (High) postures showed the highest in left foot. The increase of foot pressure lead to be inconvenience of low extremity and muscle fatigue for maintaining postural control cause pain. Thus, it is necessary to design insole-equipped working shoe for reduce the impulse and effect of foot during the rescuee handling work which standing out as foot pressure.

Comparison of the Contact Area, Maximum Pressure, Maximum Average Pressure and Maximum Force between Functional Insoles and General Insoles (기능성 인솔과 일반 인솔의 발에 대한 접촉 면적, 최대 압력, 최대 평균압력 및 최대 힘 비교)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.431-441
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the changes in the contact area, maximum pressure, maximum mean pressure, and maximum force of functional insoles and general insoles when walking. Methods: Foot pressure was measured by the ignition of functional insoles and general insoles on Company N shoes. The foot pressure was measured using a precision pressure distribution meter (Pedar - X mobile system, Novel, Germany). Each insole sensor contained 99 independent cells and was inserted between the foot and the shoe. A wireless Bluetooth-type program was used to measure the pressure detected by the measuring insoles. In order to eliminate adaptation and fatigue caused by wearing the guide during the experiment, sufficient rest was taken between each experiment, and the wearing order was randomly selected. Results: Functional insole significantly increased the forefoot and midfoot (medial, lateral) (p<0.05), while total foot, forefoot, and rearfoot peak pressure significantly decreased (p < 0.05) compared to the general insole. Conclusion: In the functional insole, a high contact area was measured inside, even in the middle of the foot, leading to a proper change in foot pressure. It was confirmed that the contact area was reduced and dispersion occurred well. In addition, it was found that the maximum pressure in the front and back of the entire foot was reduced, so the weight pressure dispersion in the functional insole was evenly distributed, and the maximum average pressure change was similar.