• 제목/요약/키워드: Area dose

검색결과 1,092건 처리시간 0.023초

Analysis of radioactivity levels and hazard assessment of black sand samples from Rashid area, Egypt

  • Abdel-Rahman, Mohamed A.E.;El-Mongy, Sayed A.
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1752-1757
    • /
    • 2017
  • The aim of this study is to evaluate the radioactivity levels and radiological impacts of representative black sand samples collected from different locations in the Rashid area, Egypt. These samples were prepared and then analyzed using the high-resolution gamma ray spectroscopy technique with a high-purity germanium detector. The activity concentration ($A_c$), minimum detectable activity, absorbed gamma dose rate, external hazard index ($H_{ex}$), annual effective dose rate equivalent, radium equivalent, as well as external and internal hazard index ($H_{ex}$ and $H_{in}$, respectively) were estimated based on the measured radionuclide concentration of the $^{238}U$($^{226}Ra$) and $^{232}Th$ decay chains and $^{40}K$. The activity concentrations of the $^{238}U$, $^{232}Th$ decay series and $^{40}K$ of these samples varied from $45.11{\pm}3.1Bq/kg$ to $252.38{\pm}34.3Bq/kg$, from $64.65{\pm}6.1Bq/kg$ to $579.84{\pm}53.1Bq/kg$, and from $403.36{\pm}20.8Bq/kg$ to $527.47{\pm}23.1Bq/kg$, respectively. The activity concentration of $^{232}Th$ in Sample 1 has the highest value compared to the other samples; this value is also higher than the worldwide mean range as reported by UNSCEAR 2000. The total absorbed gamma dose rate and the annual effective dose for these samples were found to vary from 81.19 nGy/h to 497.81 nGy/h and from $99.86{\mu}Sv/y$ to $612.31{\mu}Sv/y$, which are higher than the world average values of 59 nGy/h and $70{\mu}Sv/y$, respectively. The $H_{ex}$ values were also calculated to be 3.02, 0.47, 0.63, 0.87, 0.87, 0.51 and 0.91. It was found that the calculated value of $H_{ex}$ for Sample 1 is significantly higher than the international acceptable limit of <1. The results are tabulated, depicted, and discussed within national and international frameworks, levels, and approaches.

Electron therapy에서의 dose distribution에 관한 연구 (Research of 6MeV electron dose distribution)

  • 제재용;박철우;진성진;박은태
    • 대한방사선치료학회:학술대회논문집
    • /
    • 대한방사선치료학회 2005년도 춘계학술대회 초록집
    • /
    • pp.27-32
    • /
    • 2005
  • 임상에서 일반적으로 행하여지는 전자선은 피부암과 유방암, 두 경부 등의 다양한 부위의 치료에 사용되어진다. 본 연구에서는 6 MeV에서 bolus 사용 시 source surface distance (SSD) setup과 source bolus distance (SBD) setup에 따른 선량분포를 비교하였고 electron field 내에 nipple이 존재하는 경우의 전자선 dose 분포, 그리고 광자선과 전자선을 같이 사용할 경우 junction 부위에서의 dose 분포를 비교하였다. 이러한 모든 실험은 파라핀 phantom과 acryl, film을 이용하여 dosimetry 를 시행하였고 임상에서와 같은 조건으로 setup 한 후 전자선 선량 분포를 확인하였다. Bolus 사용시의 SSD setup과 SBD setup의 경우 $8\%$의 선량분포 차이를 보였다. Nipple이 존재하는 field 내에서는 nipple 만큼 bolus를 제거하여야 균일한 선량 분포를 얻을 수 있음을 확인하였다. 또한 광자선과 전자선을 동시에 사용하는 경우에서는 전자선 field 전체에 bolus를 사용할 때 hot spot과 cold spot을 줄이는 효과를 얻을 수 있었다.

  • PDF

방사선치료용 열가소성 플라스틱 마스크의 산란선 감소를 위한 마스크 변형에 관한 연구 (A Study of Thermoplastic Masks Deformation for Reducing Scattered Ray in Radiation Therapy)

  • 이성민;이준영;김재현;정경환;서정민
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.63-69
    • /
    • 2023
  • 두·경부 방사선치료에서 환자자세 고정과 재현성을 위하여 사용하는 열가소성플라스틱 마스크는 피부와 밀착되어 산란선을 유발한다. 고정용구 마스크에서 발생되는 산란선으로 인한 피부선량의 증가를 확인하기 위하여 고정용구의 피부밀착 부위를 감소시킴에 따른 산란선의 감소를 CT 스캔한 이미지를 이용하여 전산화치료계획 시스템을 통해 확인하였다. 또한 고정용구의 커버 부위 감소에 따른 셋업의 재현성문제를 확인하기 위하여 DRR과 CT영상을 이용하여 셋업의 차이를 확인하였다. 고정용구로 커버하는 부위를 감소시킴에 따라 피부표면의 선량은 유의하게 감소하였으며 얼굴 전체를 커버하여 고정하지 않아도 재현성에 재현성에 큰 차이가 없음을 확인하였다.

중대사고시 격납건물여과배기계통(CFVS)적용으로 인한 사고영향과 결과 고찰 (A Study on the Effect of Containment Filtered Venting System to Off-site under Severe Accident)

  • 전주영;권태은;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.244-251
    • /
    • 2015
  • 본 연구에서는 격납건물의 건전성을 유지시켜 원전 주변의 오염범위를 축소할 수 있는 격납건물 여과배기계통(containment filtered venting system, CFVS)에 초점을 맞추고, 동 설비의 설치 전 후의 피해규모를 분석하여 여과장치의 효용성을 분석하였다. 본 연구에 사용된 코드는 확률론적 영향평가 코드인 MACCS2 이며, 평가에 이용한 사고선원항은 신고리 원자력발전소 1&2 호기의 확률론적 안전성 평가 보고서의 결과를 활용하였다. 주어진 총 19 개의 사고선원항 중 선정된 3 개의 방출군에 대하여 CFVS 적용 전후의 주민이 받는 유효선량과 갑상선선량을 산출하였다. 선량평가 결과는 거리에 따른 선량으로 산출되었으며, IAEA 주민보호조치 권고 기준인 갑상선방호약품 복용 및 방호조치가 필요한 갑상선선량과 유효선량을 초과하는 거리를 기준으로 비교하였다. STC-3, STC-4, STC-6 의 거리에 따른 유효선량은 전 범위(0~35 km)에서 95~99 % 내외의 감소율을 확인할 수 있었으며, 갑상선 선량의 경우 약 96~98 % 내외의 수준으로 유효선량과는 선량감소에서의 비슷한 경향이 있음을 확인 하였다. CFVS 를 적용한 후 대피 및 소개가 취해지는 유효선량 기준값을 초과하는 거리는 모든 방출군에 대하여 평균 1 km 내외로 평가되었다. 특히 STC-4 의 경우 26 km 에서 1.2 km 로 유효 선량을 초과하는 범위가 타 방출군에 비하여 대폭 줄어든 것을 확인할 수 있었다. 갑상선선량 기준값 초과거리의 경우 CFVS 를 적용한 후의 피해범위는 2~3 km 수준으로 산출되었다. 또한 갑상선선량 평가결과는 유효선량의 경우와 같이 STC-4 에서의 피해범위가 대략 50 km 줄어들어 CFVS 적용으로 가장 큰 효과를 보았다.

디지털 심혈관조영장치의 기하학적 특성에 따른 선량 감소 (Reduction of Radiation Dose according to Geometric Parameters from Digital Coronary Angiography)

  • 강영한;조평곤
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.277-284
    • /
    • 2013
  • 심혈관 촬영 시 선량감소를 위해 실무자가 조절 가능한 기하학적 특성을 살펴보고, 각 특성에 따른 유효선량을 비교해 보았다. 인체 모형 팬텀을 이용하여 투시촬영과 영화촬영을 시행하였고, 선량의 측정은 심혈관 장치의 DAP meter를 이용하여 DAP 값을 유효선량으로 환산하였다. 먼저 영화촬영은 투시촬영에 비해 기하학적 특성 전반에 걸쳐서 선량이 약 6-7배 높았다. FPS mode에 따른 선량은 FPS를 낮게 설정할수록 선량이 70%까지 감소하였다. 선관 각도에 따른 선량은 LAO $45^{\circ}$+Caudal $30^{\circ}$이 가장 높게 측정되었고, 조사야 조절장치를 많이 적용할수록 선량은 감소하였다. X-선관과 영상증배관의 거리가 10 cm 멀어질수록 투시촬영과 영화촬영에서 각각 선량이 25-35%까지 증가하였다. FOV가 확대될수록 선량이 1.21-2배 증가하였고, 테이블과 영상증배관 거리가 10cm 멀어질수록 선량은 1.11-1.25배 까지 증가하였다. 따라서 본 연구에서 실험한 기하학적 특성인 FPS mode, 선관 각도, 조준기, 선관과 영상증배관 거리, 테이블과과 영상증배관 거리, FOV 영상 확대 등은 중재적 시술 시 실무자가 수시로 조절 가능한 인자이며, 각 특성에 따라 선량 감소 효과를 기대할 수 있다.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석 (A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy)

  • 문성권;윤선민
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.39-49
    • /
    • 2010
  • 목 적: 좌측 유방의 방사선치료에 있어, 3 빔 또는 5 빔을 이용한 세기변조방사선치료(intensity modulated radiation therapy, IMRT)와 다중빔조사영역 치료기법(multistatic fields techniques, MSF) 사이의 선량학적 차이를 분석하고자 하였다. 대상 및 방법: 개선된 선량 균일성을 만들 수 있는 가능성을 지닌 두 종류의 방사선치료 기술을 서로 비교 분석하였다. 첫째, 다중빔조사영역치료로 주조사야와 소조사야를 동시에 사용하여 치료하였다. 둘째, 고정된 다엽 조준기를 사용하는 IMRT로, 3 빔 또는 5 빔을 이용하였다. 유방보존술 후 방사선치료를 받은 16명의 초기 좌측 유방암 환자들을 대상으로 방사선치료계획들을 세운 다음, 이들을 선량학적 측면에서 비교 분석하였다. 결 과: $V_{95}$와 선량균일지수의 평균값은, 이 세 치료 사이에 통계학적으로 유의한 차이가 없었다. 방사선처방선량의 110% 이상을 받는 극심한 열점은 세 치료 모두에서 관찰되지 않았다. 동측 폐와 심장의 피폭 선량측정인자들에 대한 Tukey 검정에서, 세기변조방사선치료가 다중빔조사영역치료에 비해 저선량 영역의 피폭 선량을 유의하게 증가시킨 반면, 오히려 고선량 영역에서는 다중빔조사영역치료가 방사선 피폭을 약간 증가시켰다. 결 론: 선량 균일성 개선을 위해, 통상적인 쐐기기법 대신, 세기변조방사선치료보다 쉽게 계획되고 실시 될 수 있는 다중빔조사영역치료의 적용은 초기 좌측 유방암의 방사선치료 기술로 적합하다고 생각한다.

디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화 (Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography)

  • 권순무;김부순;박형준;강영한
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.535-540
    • /
    • 2015
  • X선 조사야(X-ray beam field)는 X선관 앞에 부착된 선속제한기구(beam limiting device)인 조리개(collimator)에 의해 조절된다. 조리개는 1차 X선을 조절하여 환자의 피폭선량을 감소시키고 산란선량을 감소시켜 영상의 화질을 향상시키는 중요한 기능을 한다. 그러나 유방촬영장치의 조리개에 대해서 따로 규정되어 있지 않으며 상업화된 장치에서는 조사야가 사각형으로 조절되는 조리개를 사용하고 있다. 최근 디지털 유방촬영장치의 보급이 확대되고 있으나 film/screen방식에서부터 적용되던 사각형으로 조사야가 조절되는 조리개가 사용되고 있다. 따라서 본 연구에서는 디지털 유방촬영에서 조사야 조절 사용에 대한 실태조사 후 유방의 크기와 모양에 따라 조사야를 조절할 수 있는 다엽조리개를 제작 후 적용했을 때 영상의 화질변화와 평균유선선량, 면적선량 값의 변화를 알아보았다. 사각형으로 조사야가 조절되는 조리개와 비교하여 다엽 조리개를 적용한 영상에서 통계적으로 유의한 차이가 없었으며 DAP값 또한 50.72% 감소되었다. 따라서 디지털 유방촬영장치에서 조사야를 최적화하기 위한 자동조사야조절장치 개발이 환자 피폭선량 감소에 도움이 될 것으로 판단된다.

뇌 및 척수조사시 치료기법의 변화가 선량분포에 미치는 영향 (The Effect of Dose Distribution under Treatment Techniques on Cerebrospinal Irradiation)

  • 이승철;김영재
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.21-28
    • /
    • 2016
  • 본 연구에서는 CSI 치료시 Standard Technique과 Simple Technique을 비교하여 조사야 접합부의 고선량(hot spot) 또는 저선량(cold spot)이 발생되는 부위의 체적을 분석하고 이에 따른 방사선 치료 유용성을 평가하고자 한다. 연구 목적에 동의한 환자를 대상으로 CT Simulator를 이용하여 환자의 두개부에서 골반부 까지 영상을 획득하였다. Standard Technique 의 경우 조사야 접합부의 이동을 실시하며 Simple Technique은 접합부에서 조사야를 고정하여 치료계획을 수립 후 분석하였다. 분석결과 Standard Technique의 경우에는 조사야 접합부분에 대한 고선량(hot spot)의 영역이 발생 되었으며, Simple Technique은 Standard 기법 보다 선량이 균등하게 나타났다. Standard Technique 과 Simple Technique의 CI 지수는 각 1.6~3, 1.6~1.87, CN의 경우는 0.32~0.53, 0.46~0.51, HI는 0.11~0.33, 0.2~0.26의 분포를 나타났다. 즉, 인접 조사야가 접합하는 조사야 부분의 선량 분포는 Standard Technique에 비해 균등하게 나타났으며, CI, CN, HI 지수를 비교한 결과 Simple Technique에서 균등한 선량 분포가 나타나 CSI 치료에서 Simple Technique의 적용은 적합하다고 판단된다.

치과 파노라마 촬영에서 공간선량률 분석 (Analysis of the Spatial Dose Rates during Dental Panoramic Radiography)

  • 고종경;박명환;김용민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.509-516
    • /
    • 2016
  • 저선량 장시간(15초 내외) X선을 조사하는 치과 파노라마 촬영장치는 교육 목적의 사용에는 원자력안전법의 규제를 받으며, 이에 따라 방사선안전 설비(경보장치, 인터록)를 설치해야 한다. 본 연구에서는 치과 파노라마 촬영에서 방사선량 및 공간선량률을 측정하여 방사선안전 설비의 실효성을 확인하고 방사선작업종사자 및 수시출입자 등의 방사선방호를 위한 기초자료를 제공하고자 하였다. 치과 파노라마 전용팬텀의 직접 피폭부위인 치아와 간접 피폭부위인 수정체와 갑상선에서 유리선량계 소자(GD-352M)를 부착한 후 X선을 3회 반복 조사하여 형광유리선량계 시스템으로 선량을 판독하였다. 팬텀 절치부를 중심으로 한 수평면을 $45^{\circ}$ 각도로 분류하여 7방향으로 구획하여 각 방향마다 30, 60, 90, 120 cm의 거리에서 공간선량률을 측정하였다. 직접 피폭부위는 최대 $984.5{\mu}Gy$가 측정되었다. 공간선량률은 30 cm에서 가장 높게 나타났으며, 120 cm로 거리가 증가할수록 선량이 감소하였다. 방향에 따라서는 30 cm 거리에서 회전 시작부위의 공간선량률이 $3,840{\mu}Sv/h$로 가장 낮은 부위인 $778{\mu}Sv/h$에 비해 4배 차이가 났다. 방사선작업종사자가 위치할 수 있는 60 cm 거리에서의 공간선량률은 평균 $408{\mu}Sv/h$로 측정되었다. 보수적인 관점에서 방사선관리구역 내에 의도하지 않은 피폭이 발생하는 경우를 대비하여 피폭선량 예측이 가능하도록 공간선량률에 대한 방사선안전 교육이 필요하지만, 현재 의료법에 의해 의료기관에서는 설치하지 않아도 되는 인터록 등의 설비는 교육용 치과 파노라마 촬영실의 공간선량률이 낮은 것을 감안할 때 원자력안전법에서 의무화 되어 있는 것은 과한 규제로 사료된다.