• Title/Summary/Keyword: Arch support

Search Result 142, Processing Time 0.036 seconds

Free Vibrations of Non-Circular Arches with Elastic Supports (탄성지점을 갖는 변화곡률 아치의 자유진동)

  • Oh, Sang-Jin;Kim, Gwon-Sik;Park, Kwang-Kyou
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.340-343
    • /
    • 2007
  • The differential equations governing free, in-plane vibrations of non-circular arches with the translational (radial and tangential directions) and rotational springs at the ends, including the effects of rotatory inertia, shear deformation and axial deformation, are solved numerically using the corresponding boundary conditions. The lowest four natural frequencies for the parabolic geometry are calculated over a range of non-dimensional system parameters: the arch rise to span length ratio, the slenderness ratio, and the translational and rotational spring parameters.

  • PDF

Ontology Mapping and Rule-Based Inference for Learning Resource Integration

  • Jetinai, Kotchakorn;Arch-int, Ngamnij;Arch-int, Somjit
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.2
    • /
    • pp.97-105
    • /
    • 2016
  • With the increasing demand for interoperability among existing learning resource systems in order to enable the sharing of learning resources, such resources need to be annotated with ontologies that use different metadata standards. These different ontologies must be reconciled through ontology mediation, so as to cope with information heterogeneity problems, such as semantic and structural conflicts. In this paper, we propose an ontology-mapping technique using Semantic Web Rule Language (SWRL) to generate semantic mapping rules that integrate learning resources from different systems and that cope with semantic and structural conflicts. Reasoning rules are defined to support a semantic search for heterogeneous learning resources, which are deduced by rule-based inference. Experimental results demonstrate that the proposed approach enables the integration of learning resources originating from multiple sources and helps users to search across heterogeneous learning resource systems.

An Orthodontic Case of Impacted Tooth Treated by Direct Bonding System (Direct Bonding System에 의한 매복치의 교정치험례)

  • Yang, Won-Sik
    • The Journal of the Korean dental association
    • /
    • v.11 no.3
    • /
    • pp.171-175
    • /
    • 1973
  • A 9-year-old girl, in good health, presented a horizontal impaction of the upper left central incisor. History revealed that the patient had been involved in a trauma of the maxillary anterior portion during her childhood. This impacted tooth crown, which was exposed surgically, was bonded by plastic attachments of direct bonding system, and was carefully tried to induce on the dental arch. On the process of the orthodontic treatment the tooth was completely induced and in normal alignment on the arch. The treatment result was very satisfactory; color, vitality, and mobility were normal, periodontal support was good and the cosmetic result was excellent.

  • PDF

Surgical Treatment of Tracheal Stenosis (기관협착증의 외과적 치료)

  • 조경수
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.834-838
    • /
    • 1989
  • Tracheal stenosis is being encountered more frequently as ventilatory support and cuffed tubes are increasingly used for treatment of respiratory failure. We experienced 13 cases of tracheal stenosis treated surgically at department of Thoracic and Cardiovascular Surgery, school of medicine, Kyung Hee university during the 4 years. The causes of tracheal stenosis were prolonged endotracheal intubation 5 cases, tracheostomy 3 cases, tracheal tumor 2 cases, thyroid tumor 1 case and congenital double aortic arch 1 case. The methods used to manage the tracheal stenosis were tracheal resection % end to end anastomosis 8 cases, 2 cases of subglottic stenosis were underwent primary laryngotracheal anastomosis, Lt. aortic arch division 1 case, and stent insertion 2 cases. In two cases, who had 6 cm in length of tracheal stenosis, we were underwent tracheal resection k end to end anastomosis with supralaryngeal release procedure. Postoperative courses were uneventful except one case with tracheal tumor.

  • PDF

Seismic Response of the Arch Structure with Column (하부기둥을 갖는 아치 구조물의 지진응답에 관한 연구)

  • Kang, Joo-Won;Lee, Sang-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.95-102
    • /
    • 2010
  • Spatial structures have the different dynamic characteristics from general rahmen structures and many studies on dynamic behavior of it is conducted. But most studies was conducted about the particular shape of spatial structures and, directly, the usable results of studies are very limited for seismic design of spatial structures with the lower structure. So, this study is conducted about the truss arch structure that the basic dynamic characteristics of spatial structure is inherent in, and the change of its seismic response is analyzed when columns have different length on both ends of it. According to the difference of column's length on both ends, the vertical acceleration response of truss arch structure is affected more than the horizontal acceleration response of it. Therefore, when the stiffness of lower structures that support the upper structure is different, the consideration of the vertical response is significantly required for the seismic design of spatial structures.

  • PDF

Experimental evaluation of the active tension bolt

  • Kim, Sang-Hwan;Song, Ki-Il;Park, Jae-Hyun
    • Geomechanics and Engineering
    • /
    • v.11 no.2
    • /
    • pp.177-195
    • /
    • 2016
  • To secure the stability of geotechnical infrastructures and minimize failures during the construction process, a number of support systems have been introduced in the last several decades. In particular, stabilization methods using steel bars have been widely used in the field of geotechnical engineering. Rock bolt system is representative support system using steel bars. Pre-stressing has been applied to enhance reinforcement performance but can be released because of the failure of head or anchor sections. To overcome this deficiency, this paper proposes an innovative support system that can actively reinforce the weak ground along the whole structural element by introducing an active tension bolt containing a spring unit to the middle of the steel bar to increase its reinforcement capacity. In addition, the paper presents the support mechanism of the active tension bolt based on a theoretical study and employs an experimental study to validate the performance of the proposed active tension bolt based on a down-scaled model. To examine the feasibility of the active tension unit in a pillar, the paper considers a pullout test and a small-scale experimental model. The experimental results suggest the active tension bolt to be an effective support system for pillar reinforcement.

Comparison of plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot (편평족 노인의 계단 하강 보행 시 아치 지지형 인솔 종류에 따른 족저압력 및 균형성 평가)

  • Han, Ki-Hoon;Bae, Kang-Ho;Jung, Ha-gon;Ha, Min-Sung;Choi, Do-Yeol;Lee, Joong-Sook;Yang, Jeong-Ok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.948-955
    • /
    • 2018
  • The purpose of this study was to compare plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot. A total of 14 women elderly were recruited for this study. Pedar-X was used to obtain plantar pressure(peak pressure, mean pressure, and contact area) and COP(distance, displacement, excursion) parameters. One-way ANOVAs were used to compare peak pressure, mean pressure, and contact area, distance of COP, displacement of COP, and excursion of COP. Among the plantar pressure parameters, significant(p<0.05) differences were observed in M3 for the peak pressure, M2, M3, and M4 for the mean pressure, and M2, M3, and M6 for the contact area. Among the COP parameters, distances of COP both in the mediolateral and anteroposterior axes revealed significant(p<0.05) differences. The larger peak pressure values of type A and B insoles were observed as compared to normal insole. The larger peak pressure and shorter COP distance values of type A and B insoles were observed as compared to normal insole.

Determination of the load carrying capacity of closed steel supports used in underground construction and mining

  • Lenka, Koubova;Petr, Janas;Karel, Janas;Martin, Krejsa
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.715-728
    • /
    • 2022
  • Closed steel supports of different shapes are used in mining and underground constructions. The supports are prefabricated from rolled, usually robust, steel profiles. The load carrying capacity of a support is considerably influenced by the active loading and passive forces. The passive forces are induced by interactions between the support and the surrounding rock mass. The analysis herein comprises three parts: The first part consists of structural geometry processing. The second part involves finding the numerical solution of a statically indeterminate structure for a specified load. The third part is calculation of the load carrying capacity and the components of internal forces and deformations. For this, the force method and numerical integration are used. The Winkler model is applied when the support interacts with the surrounding environment. The load carrying capacity is limited by the slip resistance of the connected parts and it is limited by reaching the ultimate state of the profile. This paper serves as a comprehensive reference for the determination of the load carrying capacity of closed steel supports and includes stepwise derivations of the governing formulas.

Morphometric Study on the Arterial Palmar Arch of the Hand (손바닥 동맥활에 관한 형태계측 연구)

  • Park, Bong Kwon;Jang, Soo Won;Choi, Seung Suk;Ahn, Hee Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.691-701
    • /
    • 2009
  • Purpose: Deviations of arterial palmar arches in the hand can be explained on the embryological basis. The purpose of this study was to provide new information about palmar arches through cadaver's dissection. The values of the location and diameter in these vessels were analyzed in order to support anatomical research and clinical correlation in the hand. Methods: The present report is based on an analysis of dissections of fifty - three hands carried out in the laboratory of gross anatomy. A reference line was established on the distal wrist crease to serve as the X coordinate and a perpendicular line drawn through the midpoint between middle and ring fingers, which served as the Y coordinate. The coordinates of the x and y values were measured by a digimatic caliper, and statistically analyzed with Student's t - test. Results: Complete superficial palmar archs were seen in 96.2 % of specimens. In the most common type of males, the superficial arch was formed only by the ulnar artery. In the most common type of females, the superficial arch was formed anastomosis between the radial artery and the ulnar artery. The average length of the superficial and deep palmar arch is $110.3{\pm}33.0mm$ and $67.9{\pm}14.0mm$ respectively. Regarding the superficial palmar arch, ulnar artery starts $-16.1{\pm}5.1mm$ on X - line, and $2.5{\pm}24.5mm$ on Y - line. Radial artery appears on palmar side $7.7{\pm}3.2mm$ on X - line, and $20.9{\pm}10.9mm$ on Y - line. But radial artery starts on $6.3{\pm}3.6mm$ on X - line, and $3.4{\pm}5.1mm$ on Y - line. Digital arteries of superficial palmar arch starts on $6.1{\pm}3.7mm$, $33.9{\pm}8.8mm$ on index finger, $1.8{\pm}3.4mm$, $40.1{\pm}7.3mm$ on middle finger, $-3.2{\pm}4.9mm$, $42.6{\pm}7.0mm$ on ring finger, and $-8.9{\pm}5.1mm$, $42.5{\pm}80mm$ on little finger in respective X and Y coordinates. Radial artery of deep palmar arches measured at the palmar side perforating from the dorsum of hand. It's coordinates were $9.7{\pm}4.8mm$ on X - line, $21.7{\pm}10.2mm$ on Y - line. Ulnar artery was measured at hypothenar area, and it's coordinates were $-20.4{\pm}6.3mm$ on X - line, and $30.6{\pm}7.4mm$ on Y - line. Conclusions: Anatomically superficial palmar arch can be divided into a complete and an incomplete type. Each of them can be subdivided into 4 types. The deep palmar arch is less variable than the superficial palmar arch. We believe these values of the study will be used for the vascular surgery of the hand using the endoscope and robot in the future.

Evaluation of Reinforcement Tension in RC Beams without stirrup using Truss Model (트러스 모델을 이용한 스터럽이 없는 철근콘크리트보의 주철근력 평가)

  • Rhee Chang Shin;Lee Seung Hyun;Kim Dae Joong;Kim Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.407-410
    • /
    • 2005
  • This paper describes an evaluation of reinforcement tension in RC beams using the variable truss models. The models were examined with the beam test results by Kim, Kim and White. Consequently, a fixed inclination $\theta$ at the support un-explains global state of internal force flow in cracked reinforced concrete beams subjected to shear and bending. Accordingly, we must introduce the arch factor for development of consistent model in reinforced concrete beams subjected to shear and bending

  • PDF