• Title/Summary/Keyword: Aquifer

Search Result 746, Processing Time 0.028 seconds

Modeling the Groundwater Flow in the Near-field of the Near-surface Disposal System (표층처분시스템 근계영역의 지하수 유동에 대한 모델링 연구)

  • Kim, Jung-Woo;Bang, Je Heon;Cho, Dong-Keun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.119-131
    • /
    • 2020
  • A numerical model was developed using COMSOL Multiphysics to evaluate groundwater flow that causes radionuclide migration in the unsaturated zone of a near-surface disposal facility, which is considered as a domestic low and an intermediate-level radioactive waste disposal facility. Each scenario was modeled by constructing a two-dimensional domain that included the disposal vault, backfill, disposal cover, and unsaturated aquifer. A comparison of the continuous and intermittent rainfall conditions exhibited no significant difference in any of the factors considered except the wave pattern of water saturation. The input data, such as porosity and residual water content of the unsaturated aquifer, were observed to not have a significant effect on the groundwater flow. However, the hydraulic conductivity of the unsaturated aquifer was found to have a significant effect on the groundwater flow. Therefore, it is necessary to assess the hydraulic conductivity of an unsaturated aquifer to determine the extent of groundwater infiltration into the disposal vault.

A Study of Carvernous Limestone Aquifer of Jeon Cheon Basin (전천 석회암 대수층에 관한 연구)

  • 한종상
    • Water for future
    • /
    • v.16 no.3
    • /
    • pp.171-179
    • /
    • 1983
  • In the Jeon Cheon Basin, unconsolidated alluvium and marine clay beds overlying Tertiary conglomerate and impermeable mudstone, and Cambro-Ordovician sedimentary rocks composed of mainly cavernous limestones, and age-unknowned crystalline rocks are occured. Most productive rock is Cambro-Ordovician limestones containing a lot of solution openings and secondary porosities and shows its transmissivity of 1836$m^2$/day and storativity of 1.47 $\times$ $10^{-3}$. The storage of deep seated groundwater in linestone aquifer is estimated about 1059 $\times$ $10^6$ metric tons, being equivalent to 6 years total precipitation of the basin. The safe yield of the groundwater to be abstracted from the aquifer is about 126,000 tons/day. To pump at least 100,000 tons/day of groundwater from the said aquifer, a well field comprising 34 deep wells ranging in depth from 80 to 100 meter and penetrating the cavernous limestone aquifer shall be established at middle and down stream area.

  • PDF

Analysis of a Microbial Community Denitrying Nitrate to Nitrogen Gas in a Nitrate-Contaminated Aquifer

  • Jin-Hun, Kim;Bong-Ho, Son;Su-Yeol, Gwon;Seong-Uk, Eo;Yeong, Kim
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.175-178
    • /
    • 2004
  • Little study has been published specifically addressing the dynamics of nitrate reducing bacteria (NBR) during the bioremediation of nitrate-contaminated aquifer. In our previous study we successfully quantified fumarate-enhanced microbial nitrate reduction rate in a nitrate-contaminated aquifer by using a series of single-well push-pull tests (PPTs). In this study we analyzed the suspended population during PPTs. To monitor changes in the microbial community, PCR amplification of 16S rDNA genes and denaturing gradient gel electrophoresis (DGGE) were used to study the dynamics of the bacterial community in detail. Before the stimulation of NBR, the dominant DGGE bands obtained by PCR were affiliated with V-Proteobacteria consisting of Acinetobacter spp. and Pseudomonas fluorescens. However, as NBR biostimulation proceeded, the dominant patterns of DGGE bands changed, and they were affiliated with Azoarcus denitrificans Td-3 and Flavobacterium xanthum. Azoarcus denitrificans Td-3 is known to completely reduce nitrate to nitrogen gas. The series of single-well push-pull tests in this study should prove useful for conducting rapid, low-cost feasibility assessments for in situ denitrification and provide important information about which microorganisms play a key role in bioremediation of a nitrate contaminated aquifer.

  • PDF

Analysis of Pumping Test Data and The Prediction of Drawdown for Daejong-Chun Area (대종천유역 충적대수층의 수리성 분석 및 수위강하예측에 관한 연구)

  • Choi, Jae-Jin;Sung, Won-Mo;Hahn, Jeong-Sang
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.541-549
    • /
    • 1993
  • The main goal of this paper is to determine hydraulic properties and to predict drawdown for the efficient and stable development of groundwater in the Daejong-Chun area, North of Kyungsang-Do. Based on geological survey and analysis of well logging data conducted in 1991, it is found that the type of aquifer of this area is considered to be an anisotropic unconfined aquifer with saturated thickness of 19.8 m. In order to characterize this aquifer pumping test was conducted, and the resulting drawdown data were utilized for the analysis by applying both type curve matching technique and semi-log straight line method. As a result, the average specific yield of this aquifer is estimated as 32.3%, and the average ratio of $K_H$ to $K_V$ is only 2.7, which means that gravitational effect is not significant factor for this type of aquifer. For the validation of the estimated hydraulic properties, the analytical model which was developed with Newton-Raphson iteration procedure in this study, was employed to generate the drawdown. And, the resulting drawdown was compared against actual drawdown data and it shows the excellent matches. The actual drawdown data for 9 hours of pumping were used for history matching purposes and relatively satisfactory matches were achieved in this match. Then, the model was run by using the tuned parameters that are obtained during history matching stage, and the drawdown was predicted for the next 30 years of pumping with $3,000m^3/day$ of constant pumping rate. Its result indicates that the drawdown was stabilized as 1.41 m from 20 days with $3,000m^3/day$ of constant pumping rate, which is the required amount of water to be safely supplied to this area.

  • PDF

IP Characteristics of Sand and Silt for Investigating the Alluvium Aquifer (충적대수층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.423-431
    • /
    • 2008
  • In general, water-saturated silt or clay alluvium is characterized with relatively low-resistivity. Thus we often encountered the problem that such a low-resistivity layer is misguided to be good aquifer of high-permeability and low-resistivity in the development of groundwater. This research was conducted with an emphasis on the identification of saturated silt or clay layer from the aquifer by performing the laboratory experiment of IP and resistivity methods on the various materials consisting of alluvium aquifer. Silt or clay layer is found to be characterized with the higher chargeability zone, compared to the sand layer. Regarding the mixture of sand and clay, the higher clay volume, the lower resistivity and the higher chargeability. Subsequently chargeability decreases.

Hydrogeologic Parameter Estimation by Using Tidal Method in a Fractured Rock Aquifer (단열암반 대수층에서 조석분석법을 이용한 수리상수 추정)

  • Shim Byoung Ohan;Chung Sang Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.3
    • /
    • pp.27-32
    • /
    • 2004
  • The oceanic tides have an effect on groundwater levels in coastal fractured rock aquifers. The observed groundwater table fluctuations caused by the effective stress through an aquifer are shown as sine curves similar with tidal fluctuation. To estimate a hydrogeologic parameter, tidal method is utilized with groundwater level fluctuations of two monitoring wells. Cross correlation function is used to calculate time lags between observed groundwater levels and tide, and the deeper well shows longer time lag. The storage coefficients calculated by using tidal efficiency and time lag show large differences. The storage coefficients obtained by using time lags are close to the result of slug test, and that of the deeper well shows closer value by slug test. The tidal efficiency is unsatisfied to apply in the tidal method because of an effect of phreatic aquifer and the vertical flow of groundwater through fractured confining bed. This tidal method can be an economical and effective way to define the parameter by considering the location of observation well and hydrogeologic characteristics of a coastal aquifer.

A Review of Methods for Hydraulic Parameters Determination of Aquifer (대수층의 수리상수 결정에 관한 여러 가지 방법의 비교)

  • 김민환
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.3
    • /
    • pp.153-160
    • /
    • 1997
  • In order to use and conserve groundwater efficiently, in the first place the values of transmissivity and storage coefficient have to be correctly estimated. Various methods to determine hydraulic parameters of aquifer were reviewed and the characteristics of the methods were described in this paper. They were compared to obtaine parameters by various methods. An improved method to estimate the hydraulic parameters of aquifer is suggested by the comparison of the previous methods.

  • PDF

2-D Consolidation Numerical Analysis of Multi_Layered Soils (다층 지반의 2차원 압밀 수치해석)

  • 김팔규;류권일;남상규;이재식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.467-474
    • /
    • 2000
  • The application of Terzaghi's theory of consolidation for analysing the settlement of multi-layered soils is not strictly valid because the theory involves an assumption that the soil is homogeneous. The settlement of stratified soils with confined aquifer can be analysed using numerical techniques whereby the governing differential equation is replaced by 2-dimensional finite difference approximations. The problems of discontinuous layer interface are very important in the algorithm and programming for the analysis of multi-layered consolidation using a numerical analysis, finite difference method(F.D.M.). Better results can be obtained by the process for discontinuous layer interface, since it can help consolidation analysis to model the actual ground The purpose of this paper provides an efficient computer algorithm based on numerical analysis using finite difference method(F.D.M) which account for multi-layered soils with confined aquifer to determine the degree of consolidation and excess pore pressures relative to time and positions more realistically.

  • PDF

Hydrogeochemical processes and behavior of nitrate in an dlluvial aquifer: A preliminary result from Cheonan area, Korea

  • Kim, Kyoung-Ho;Yun, Seong-Taek;Choi, Byoung-Young;Kim, Kang-Joo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.97-99
    • /
    • 2004
  • To understand the geochemical processes controlling the distribution of nitrate and other agricultural constituents in an alluvial aquifer, hydrogeological and hydro geochemical studies were carried out in an agricultural area within Cheonan. In this selected field, nitrate concentrations were very wide in range but was locally attenuated significantly down to very low levels (<1.0 mg/L). Abrupt removal of nitrate coincided with the pattern of redox change and thus indicated that geochemical processes occurring during and after recharge events control the behavior and distribution of nitrate and other redox-sensitive chemical species.

  • PDF

Evaluation of Natural Attenuation of Petroleum Hydrocarbons in a Shallow Sand Aquifer: a Modeling Study (자연저감 모델링 연구)

  • 이진용;이명재;이강근;이민효;윤정기
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.128-131
    • /
    • 2001
  • We evaluated natural attenuation of petroleum hydrocarbons in a shallow aquifer using a modeling study. The studied shallow aquifer was severely contaminated with petroleum hydrocarbons, especially toluene, ethylbenzene and xylenes (i.e, TEX). The exact spill history was not known. Therefor we used a contaminant level in May 1999 (the first sampling date of our integrated study) as an initial contaminant concentration. we calibrated required transport parameters using the contamination levels obtained from groundwater analyses in September of 1999. For fate and transport of the petroleum contaminants, five case 2 with sorption and degradation. case 3 with sorption and degradation (half decay constant compared with case 2), case 4 with degradation but no sorption, and case 5 with sorption but no degradation. For sorption and degradation, a linear sorption isotherm and first order irreversible decay was assumed, respectively and no additional contamination source to groundwater is also assumed.

  • PDF