• Title/Summary/Keyword: Apposition

Search Result 85, Processing Time 0.03 seconds

Eyes and Vision of the Bumblebee: a Brief Review on how Bumblebees Detect and Perceive Flowers

  • Meyer-Rochow, V.B.
    • Journal of Apiculture
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2019
  • Bumblebees have apposition compound eyes (one on either side of the head) of about 6,000 ommatidia and three small single-lens ocelli on the frons of their head capsule. The surface of the eye is smooth and interommatidial hairs, as in the honeybee, are not developed. Each ommatidium (approx. 26 ㎛ in diameter) is capped by a hexagonal facet and contains in its centre a 3 ㎛ wide, columnar light-perceiving structure known as the rhabdom. Rhabdoms consist of thousands of regularly aligned, fingerlike microvilli, which in their membranes contain the photopigment molecules. Axons from each ommatidium transmit the information of their photic environment to the visual centres of the brain, where behavioural reactions may be initiated. Since bumblebee eyes possess three classes of spectrally different sensitivity peaks in a ratio of 1:1:6 (UV= 353 nm, blue= 430 nm and green=548 nm) per ommatidium, they use colour vision to find and select flower types that yield pollen and nectar. Ommatidial acceptance angles of at least 3° are used by the bumblebees to discriminate between different flower shapes and sizes, but their ability to detect polarized light appears to be used only for navigational purposes. A flicker fusion frequency of around 110Hz helps the fast flying bumblebee to avoid obstacles. The small ocelli are strongly sensitive to ultraviolet radiation and green wavelengths and appear to act as sensors for light levels akin to a photometer. Unlike the bumblebee's compound eyes, the ocelli would, however, be incapable of forming a useful image.

An effect of immediate orthodontic force on palatal endosseous appliance$(C-Palatal\;Plate^{TM})$ in beagle Dog (성견 구개부 골내고정원 장치에 가해진 즉시 교정력이 주위조직에 미치는 영향)

  • Kim, Su-Jung;Lee, Young-Jun;Chug, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.91-102
    • /
    • 2003
  • This study was performed to investigate the effect of immediate orthodontic force on soft md hard tissues surrounding C-Palatal $Plate^{TM}$ in beagle Dog. Immediately after this appliance was implanted on the midpalate of 4 adult beagle Dogs, 400gm continuous orthodontic force was applied. Experimental animals were euthanized at 8weeks, 18weeks, and 22weeks (including post-removal healing time of 4weeks), and a control animal was euthanized at 8weeks after implantation without orthodontic force application. The appliance and the surrounding tissue were studied radiographically, macroscopically, and histologically. The results were as follows: 1. The lateral radiographs taken after euthanasia showed very slight displacement of the vortical plate in the experimental animals, compared with the control animal. Mobility test of all animals confirmed primary stability without any increase of mobility during experimental period. 2. No pathologic changes were found in the healing condition of covering soft tissue and bone-screw interface in experimental animals as well as a control animal. 3. Osseointegration was achieved in the bone-screw interface in 8weeks after implantation and the amount of osseointegration increased in 18weeks. There was little difference of osseointegration between the compression side and the tension side. 4. In the marginal bone area, slight bone apposition and resorption were found regardless of compression and tension side, while there was no change in the control animal. 5. Both 8week-animal and 18week-animal showed the new bone apposition along the surface of screws which were perforated into the nasal cavity, while the control animal showed no change. 6. After 4weeks of plate removal, the covering epithelium was repaired intactly, while the connective tissue showed loose and irregular rearrangement and the connective tissue capsule remained. The C-Palatal $Plate^{TM}$ manifested sufficient anchorage capacity in the context of histological study as well as clinical outcomes, when immediate orthodontic force was applied after implantation.

Finite Element Analysis of Stress Distribution around the Micro-Patterned Implants (마이크로패터닝을 부여한 임플란트 주변골에서의 하중 분포에 관한 유한요소분석법적 연구)

  • Hur, Bae-Young;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2008
  • Implant requires long lasting, strong osseointegration using bio-mechanical interlocking by bone ingrowth. In regarding the size level for bone ingrowth, the micro-patterning would enhance bone response. Micro-patterning can increase the area contacting the bone tissues. Therefore, it may distribute the load to the surrounding bone tissue, more effectively. This study compared and analyzed the load distributing effect with the shape and number of micro-patterning. For the optimal comparison of threads, the assumptions different from general finite element analysis model were made. It was assumed that the implant was axisymmetric and infinitely long. The implant was assumed to be completely embedded in the infinitely long cortical bone and to have 100% bone apposition. The implant-bone interface had completely fixed boundary conditions and received an infinitely big axial load. The condition of threads were as follows. The reference model 1 had conventional thread. Model 2 had 2 micro-patterns on the upper flank of the thread. Model 3 had 2 micro-patterns on the lower flank of the thread. Model 4 had 2 micro-patterns on the upper and lower flanks of the thread. Model 5 had 3 micro patterns on the upper and lower flanks of the thread. The results were as follows: 1. The thread with micro-patterns distributed stress better than the conventional thread. 2. The thread with micro-patterns on the lower flank distributed stress better than that with micro-patterns on the upper flank. 3. The thread with 3 micro-patterns distributed stress better than that with 2 micro-patterns, However, an area with stress concentration occurred.

The effect of progressive tensional force on mRNA expression of osteoprotegerin and receptor activator of nuclear factor ${\kappa}B$ ligand in the human periodontal ligament cell (기계적 자극이 치주인대 세포의 osteoprotegerin과 receptor activator of nuclear factor ${\kappa}B$ ligand mRNA 발현에 미치는 영향)

  • Lee, Kie-Joo;Lee, Syng-Ill;Hwang, Chung-Ju;Ohk, Seung-Ho;Tian, Yu-Shin
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.262-274
    • /
    • 2005
  • Tooth movement is a result of mutual physiologic responses between the periodontal ligament and alveolar bone stimulated by mechanical strain. The PDL cell and osteoblast are known to have an influence on bone formation by controlling collagen synthesis and alkaline phosphatase activation. Moreover. recent studies have shown that the PDL cell and osteoblast release osteoprotegerin (OPG) and the receptor activator of nuclear factor ぉ ligand (RANKL) to control the level of osteoclast differentiation and activation which in turn influences bone resorption. In this study. progressively increased, continuous tensional force was applied to PDL cells. The objective was to find out which kind of biochemical reactions occur after tensional force application and to illuminate the alveolar bone resorption and apposition mechanism. Continuous and progressively increased tensile force was applied to PDL cells cultured on a petriperm dish with a flexible membrane The amount of $PGE_2$ and ALP synthesis were measured after 1, 3, 0 and 12 hours of force application. Secondly RT-PCR analysis was carried out for OPG and RANKL which control osteoclast differentiation and MMP-1 -8, -9, -13 aud TIMP-1 which regulate the resolution of collagen and resorption of the osteoid layer According to the results. we concluded that progressively increased, concluded force application to human PDL cells reduces $PGE_2$ synthesis, and increases OPG mRNA expression.

ALVEOLAR BONE CHANGES AROUND THE NATURAL TEETH OPPOSING THE POSTERIOR IMPLANTS IN MANDIBLE (임플랜트로 수복된 하악 구치부에 대합되는 자연치 주변의 골변화)

  • Jung, Won-Mo;Kim, Dae-Gon;Yi, Yang-Jin;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.263-273
    • /
    • 2007
  • Statement of problem: Alteration of tooth function is assumed to be changed by stress/strain on the adjacent alveolar bone, producing changes in morphology similar to those described for other load-bearing bones. When teeth are removed, opposing teeth will not be functioned. When edentulous area is restored by implant prostheses, opposing teeth will be received physiologic mechanical stimuli. Purpose: The aim of this study was to evaluate the bone changes around the teeth opposing implant restoration installed mandibular posterior area. Material and method: Eight patients who had mandibular posterior edentulous area were treated with implants. Radiographs of the opposing teeth were taken at implant prostheses delivery(baseline), 3 months, and 6 months later. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of opposing teeth. Direct digital image was obtained. Gray values of region of interest at each digital image were measured and compared according to time lapse. Repeated measured analysis of variance and post-hoc Scheffe's test were performed at the 95% significance level. Results: Alveolar bone changes around the natural teeth opposing the posterior implant in mandible showed statistically significant difference compared to control group(P<0.05). And gray values of alveolar bone around the teeth opposing implants were increased. There were no statistically significant differences of alveolar bone changes between crestal group and middle group and between mesial group and distal group according to time lapse(P>0.05). There were no statistically significant differences of alveolar bone changes among mesial-crestal group, mesial-middle group, distal-crestal group, distal-middle group, and control group(P>0.05). Conclusion: Alveolar bone around the natural teeth opposing the implant prosthesis showed gradual bony apposition.

In Vitro Development of Porcine Oocytes Following Intracytoplasmic Injection of Round Spermatid (원형정자 미세주입에 의한 돼지 난자의 체외 배 발달)

  • Shin J. S.;Kim, C.;S. J. Uhm;Kim, N. H.;Lee, H. T.;K. S. Chung
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.4
    • /
    • pp.395-403
    • /
    • 1998
  • In this study we determined fertilization processes and developmental ability of porcine oocytes following injection of round spermatid in the presence and absence of artificial activation. Electrical stimulation at 2 h before spermatid injection significantly increased the incidence of normal fertilization as compared to those following injection without stimulation or with stimulation immediately after injection. The incidences of two pronuclear formation and apposition were not different in oocytes between following intracytoplasmic spermatid and spermatid nucleus injection. Indirect immunocyto chemistry and laser scanning confocal microscopy study revealed that microtubuels were organized from the oocyte cortex following round spermatid injection, and this seemed to move both male and female pronuclei into the oocyte center. At 6 days following injection blastocoele formation was seen in the eggs following round spermatid (25%) and round spermatid nucleus injection (27%). However, none of oocytes developed to the blastocyst stage at 6 days following sham injection. The average cell numbers of blastocysts at 8 days following injection of spermatid and spermatid nucleus were 87 to 99. These results suggested that either round spermatid or it's nudeus can be used to produce viable embryos by injection into unfertilized oocytes in the pig.

  • PDF

Microscopic Study of the Pig Peri-implantation Embryos (전자현미경에 의한 착상 전후 돼지수정란의 형태학적 변화에 관한 연구)

  • 김진회;백청순;이훈택;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.18 no.2
    • /
    • pp.141-150
    • /
    • 1994
  • Morphological features of the interaction between the hatching blastocyst and implantation in pig were studied by electron microscopy. The observations extended from late blastocyst stage to the completion of trophoblastic erosion of the epithelium and early decidual transformation of the epithelium and early decidual transformation of the stromal cells. Between day 7 and 17 of pregnancy, blastocysts from 0.3 to 12 mm in diameter were flushed from the uterine horns of Dutch Landrace pigs. On the 7th of development in the pig blastocyst, the blastocyst shedded of the zona pellucida established the tips of microvilli and with bleb-like cytoplasmic protrusions of the epithelial cells. From day 11 on in pig embryo, the bilayered trophoblast undergoes a dramatic phase of elongation so that the initially spherical expanded blastocyst becomes tubular. In pig, close apposition to the uterine wall beg-ins at about 12 $^1$/$_2$ days and then attachment occurred during the afternoon of the 16th or 18th day post coitum. At this stage, embryonic loss compared with corpus luteum number is up to 40% of ovulated oocytes. Therefore, the implantation failture of these embryos may be mainly caused by morphological abnormality and failture of zona shedding.

  • PDF

Aberrant Microtubule Assembly and Chromatin Configuration of Homan Oocytes Which Failed to Complete Fertilization Following In Vitro Fertilization and Intracytoplasmic Sperm Injection (일반적 수정과 세포질내 정자주입법에 의해 수정에 실패한 인간난자의 미세소관과 염색체의 형태이상)

  • Chung, H. M.;Kim, N. H.;Kim, J. W.;J. M. Lim;Park, C.;J. J. Ko;K. Y. Cha;Kim, J. M.;K. S. Chung
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.2
    • /
    • pp.143-154
    • /
    • 2000
  • Most eggs initiated the fertilization processes but arrested at specific stages. The stages included failure of the oocyte to exit from the meiotic metaphase-II with or without sperm penetration, failure of appropriate sperm aster formation, inability to form proper male and female pronuclei, failure of suitable pronuclear apposition, and failure to form proper number of either male or female pronuclei. Various images of defective microtubule organization and chromatin configuration during IVF and ICSI procedures were observed. We discussed the data with previous research results during normal fertilization in humans and other mammals. In conclusion, various aberrant patterns in microtubule assembly and chromatin configuration, which were assessed in the present study, could be used as criteria to improve assisted reproductive technology in clinics. However, further cellular and molecular characterization is needed to clarify these aberrant patterns of cytoskeletal assembly.

  • PDF

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

CONDYLAR ADAPTATION UNDER LATERAL DEVIATION OF THE RABBIT MANDIBLE (가토의 하악골 측방 변위에 의한 하악과두 변화)

  • Park, Hae-Sung;Park, Young-Ju;Ahn, Byoung-Keun;Rhee, Gun-Joo;Park, Jun-Woo;Lee, Young-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.446-454
    • /
    • 2000
  • Condylar process of mandible is an important and fuctionally versatile part of the mandible. There were quite large amount of investigations on the functional and anatomical adaptation of the temporomandibular joint(TMJ) to the surrounding tissues. But controversies on the mechanism of functional adaptation of the joint still exist. In this research, we investigated changes in the TMJ by the lateral deviation of the maxillary incisor to shift the mandible right, and bone the undecalcified microscopic sections with fluorescent microscope and von Kossa staining with bright field microscope. Results were as follows: 1. Lateral deviation rendered shifting and tilting of the mandible, There were, compressions in the right joint and opening of the left joint space at early stage. At the same time, both condyles shifted slightly to anterior. 2. After $2{\sim}4$ weeks, left condyle showed anterior displacement and compressions in the joint space. Right condyle showed only slight shift to the anterior. 3. Regardless of the direction of the lateral shift, anterior bite plate compressed both condyle heads until 2 weeks. 4. There are bone resorptions in the anterior aspect of the condyle head and apposition of posterior border. Bone remodeling were observed between 3 and 4 weeks. 5. After 8 weeks of the experiment, there were little differences in condylar morphology between experimental and control group, though slight shifting and compression were still present in the experimental group. Lateral deviation of mandible evoked active remodeling of the TMJ until functional and anatomical reconstruction of TMJ position was achieved.

  • PDF