References
- Misch CE. Contemporary implant dentistry. 2nd ed. Missouri, USA: Mosby press;1999. p.225-237, 317-328
- Wolff J. Das Gesetz der transformation der Knochen. 1892(abstract only)
- Frost HM. Bone 'Mass' and the 'Mechanostat': A proposal the anatomical record. Anat Rec 1987;219:1-9 https://doi.org/10.1002/ar.1092190104
- Bender IB, Seltzer S. Roentgenographic and direct observation of experimental lesions in bone I. J Endod 2003;29: 702-6 https://doi.org/10.1097/00004770-200311000-00005
- Bender IB, Seltzer S. Roentgenographic and direct observation of experimental lesions in bone II. J Endod 2003;29: 707-12 https://doi.org/10.1097/00004770-200311000-00006
- Cho HH; Kim EK. Experimental study on quantitative evaluation of film-based digital imaging system. J Korean Oral Maxillofac Radiol 1994;24:137-48
- Strid KG, Killebo P. Bone mass determination from microradiographs by computer- assisted videodensitometry. Acta Radiol Diagn 1988;29:465-72 https://doi.org/10.3109/02841858809175022
- Vos MH, Janssen PTM, van Aken J, and Heethaar RM. Quantitative measurement of periodontal bone changes by digital subtraction radiography. J Periodontal Res 1990;25:268-75 https://doi.org/10.1111/j.1600-0765.1990.tb00915.x
- Reddy MS, Jeffcoat KM. Digital subtraction radiography. Dent Clin North Am 1993;37:553-65
- Mol A. Dunn SM. The performance of projective standardization for digital subtraction radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003; 96:373-82 https://doi.org/10.1016/S1079-2104(03)00357-3
- Andressen J, Nielsen HE. Assessment of bone mineral content and bone mass by non-invasive radiologic methods. Acta Radiol Diagn 1984;100:908-11
- Ludlow JB, Soltmann R, Tyndall D, Grady J. Accuracy of quantification of mandibular condyle displacement in digitally subtracted linear tomograms. Dentomaxillofac Radiol 1992;21:81-7
- Hausmann E, Bale WF, Warren SL, van Huysen G. Techniques for assessing alveolar bone mass changes in periodontal disease with emphasis on I-absorptiometry. J Clin. Periodontol 1983;10:455-64 https://doi.org/10.1111/j.1600-051X.1983.tb02178.x
- Steflik DE, Noel C, McBrayer C, Lake FT, Parr GR, Sisk AL, Hanes PJ. Histologic observations of bone remodeling adjacent to endosteal dental implants. J Oral Implantol 1995;21:96-106
- George ER, Chooi GT, Chong HS, Helmut W, Hashim Y. Bone-implant interface around titamium implants under different loading conditions: A histomorphometrical analysis in the Macaca Fascicularis monkeys. J Periodontol 2003;74:1483-90 https://doi.org/10.1902/jop.2003.74.10.1483
- Johnson RB. Effect of altered occlusal function on transseptal ligament and new bone thicknesses in the periodontium of the rat. Am J Anat 1990;187:91-7 https://doi.org/10.1002/aja.1001870110
- Kinoshita Y, Tonooka K, Chiba M. The effect of hypofunction on the mechanical properties of the periodontium in the rat mandibular first molar. Arch Oral Biol 1982;27:881-5 https://doi.org/10.1016/0003-9969(82)90045-0
- Lee MR, Cho LR, Yi YJ, Choi HM, Park CJ. Correlation assessment between resonace frequency analysis and radiographic method according to peri-implant bone change. J Korean Acad Prosthodont 2005; 43:736-44
- Marx RE, Ehler WJ, Peleg M. Mandibular and facial reconstruction: Rehabilitation of the head and neck cancer patient. Bone 1996;19(1 suppl):59-82 https://doi.org/10.1016/S8756-3282(96)00137-8
- Kuroe T, Itoh H, Caputo AA, Nakahara H. Potential for load-induced cervical stress concentration as a function of periodontal support. J Esthet Dent 1999;11:215-22 https://doi.org/10.1111/j.1708-8240.1999.tb00401.x
- Jeon PD, Turley PK, Moon HB, Ting K. Analysis of stress in the periodontium of the maxillary first molar with a three-dimensional finite element model. Am J Orthod Dentofacial Orthop 1999;115: 267-74 https://doi.org/10.1016/S0889-5406(99)70328-8
- Graf H, Grassel H, Aeberhard HJ. A method for the measurement of occlusal forces in three directions. Helv Odont Scand 1974;18:7-11
- Grondahl K, Sunden, Grondahl HG. Interand intraobserver variability in radiographic bone level assessment at Branemark. Clin Oral Impl Res 1998;9: 243-50 https://doi.org/10.1034/j.1600-0501.1998.090405.x
- Jeffoat MK, Reddy MS, Webber RL, Williams RC, Ruttimann UE. Extraoral control of geometry for digital subtraction radiography. J Periodont Res 1987;22: 369-402
- Meijer HJA, Steen WHA, Bosman F. Standardized radiographs of alveolar crest around implant in the mandible. J Prosthet Dent 1992;68:318-21 https://doi.org/10.1016/0022-3913(92)90337-A
- Stanford CM. Issues and considerations in dental implant occlusion: What do we know, and what do we need to find out? J Calif Dent Assoc 2005;33:329-36
- Huh YJ, Jeon IS, Huh MS, Lee SS, Choi SC, Park Tw, Kim JD. A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images. Korean J Oral Maxillofac Radiol 2002; 32:101-11