• Title/Summary/Keyword: Application Conditions

Search Result 5,963, Processing Time 0.036 seconds

DSP based SRM Drive System for EPS Application (DSP 기반의 EPS용 SRM 구동 시스템 개발)

  • Kim, Bong-Chul;Ahn, Young-Ju;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.13-15
    • /
    • 2003
  • This paper presents a design and characteristics analysis of a SRM drive for EPS application. A rack mounted EFS system is considered in this paper. A conventional driving room space and mechanical structure are suggested in design stage. In the restricted design conditions, motor parameters are determined for sufficient torque and speed. For the smooth torque generation and simple circuit of power system, 12/8 motor drive is considered. With FEM and magnetic circuit analysis designed motor is simulated to meet the requirement of specifications. Effectiveness of the suggested SRM drive for EPS application is verified by the manufactured prototype motor drive tests.

  • PDF

A Study on Application of Fatigue Correction Factor for Environmental Fatigue Evaluation of Pressurizer Surge Line (가압기 밀림관 환경피로평가를 위한 피로보정계수 적용에 관한 연구)

  • Yang, Jun-Seog;Park, Chi-Yong;Kang, Seon-Ye
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1151-1157
    • /
    • 2009
  • Nuclear power plants applying for the continued operation over design life are required to address the effects of reactor water environment in fatigue design requirement of the ASME Code. Reactor water environmental effects are generally evaluated by calculating fatigue correction factors on fatigue usage. This paper describes the application for pressurizer surge line of environmental fatigue correction factors and the strain rate impact in the application. From this paper, the environmental fatigue correction factors resulted from the assumption of a step change in temperature are especially compared with those calculated from the data measured during plant startup. As a conclusion of this paper, the design transient conditions applied to the fatigue design may be conservative in case of the environmental fatigue evaluation.

A Study of Economic ESS Utilization Based on Supplement Control Plan for Stable Wind Energy Extraction (풍력발전의 전력공급 안정화를 위한 ESS 보조제어 기법과 경제적 용량 산정 연구)

  • Jung, Seungmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.22-28
    • /
    • 2018
  • In case of developing a combined system by a number of distributed resources with storage device, a number of application suggests a huge capacity can derive operational flexibility both power supply issues or when unexpected situation imposed. However, it is important to determine a resonable energy capacity because the device have many controversial cost issues in current power system industry. An ESS application which focusing essentially required points can induce appropriate storage capacity that required in economic operation. In this paper, a curtailment supporting algorithm based on storage device is introduced, and applied in the capacity calculation method. The main algorithm pursues handling minor exceeding quantities which can cause mechanical load at blade; This paper tries to include it for configuring hybrid algorithm with pitch control. Several fluctuating conditions are utilized in simulation to reflect critical situation. The analyzing process focuses on the control feasibility with applied capacity and control method.

A Study on the Evaluation of Brinell Standard Hardness Tester and Automatic Indentation Measurement System (브리넬 경도 표준 시험기 및 압입 자국 자동 측정장치의 특성 평가에 대한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.4
    • /
    • pp.294-302
    • /
    • 1999
  • Evaluation of Brinell standard hardness tester was carried out to secure its application as a national standard for Brinell hardness. Accuracies and reliabilities in load application, indenter diameter and indentation measurement were tested through evaluation of these components. The accuracies of load application for various loading conditions were within the limit of ISO and KS specifications. Errors in the indentation measurement due to the difference in personnel characters were successfully removed by utilising automatic indentation measurement system. In overall, the tester and the indentation measuring system were found to be eligible as a national standard of Brinell hardness.

  • PDF

Development of a 3-D Visualization Application for Management of Substation Equipment

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.38-44
    • /
    • 2009
  • This paper presents a new windows application based on 3-D graphics and Text-To-Speech (TTS) for effective management of substation equipment. When problems in a power system occur, inexperienced power system operators may have difficulty in understanding the situation as well as finding suitable countermeasures quickly. This paper addresses an effective scheme to visualizing power system equipment under normal and abnormal conditions using 3-D graphics and animations. In addition, the state variations and the order of maintenance priority of substation equipment are represented by TTS and intuitive methods. The proposed system can help power system operators to more quickly understand the state of power system equipment, and it can provide operators with the suitable countermeasures for minimizing damage caused by equipment problems.

Performance Improvement Design and Characteristics Analysis of SRM for EPS Application (EPS 적용을 위한 SRM의 효율향상 설계 및 특성)

  • Kim Bong-Chul;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.58-60
    • /
    • 2004
  • This paper presents a design and characteristics analysis of an SRM drive for EPS application. A rack mounted EPS system is considered in this paper. In the unrestricted design conditions, motor parameters are determined for sufficient torque and speed with some restrictions. For the smooth torque generation and simple circuit of power system, 12/8 motor drive is considered. With FEM and magnetic circuit analysis, redesigned motor is simulated to meet the requirement of specifications. Effectiveness of the suggested SRM drive for EPS application is verified by redesigned motor drive tests.

  • PDF

Design and Drive Characteristics of SRM for EPS Application (EPS용 SRM의 설계 및 운전특성)

  • 안진우;손익진;이동희
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.587-594
    • /
    • 2003
  • This paper presents a design and characteristic analysis of an SRM drive for EPS(Electrically Power Steering) application. A rack mounted EPS system is considered in this paper. A conventional driving room space and mechanical structure are considered in a design stage. In the restricted design conditions, motor parameters are determined for sufficient torque and speed. For the smooth torque generation and simple circuit of power system, 12/8 motor drive is considered. With FEM and magnetic circuit analysis, designed motor is simulated to meet the requirement of specifications. Effectiveness of the suggested SRM drive for EPS application is studied by the drive tests of a prototype motor.

Performance Comparison between Inverse Class-F and Class-F Amplifiers Based on the Waveform Analysis

  • Yang, Youn-goo;Woo, Young-Yun;Kim, Bum-man
    • Journal of electromagnetic engineering and science
    • /
    • v.2 no.1
    • /
    • pp.5-10
    • /
    • 2002
  • We have analized the inverse class-F and class-F amplifiers using their waveforms. From the analytic equations derived from the analysis, we have calculated tole efficiencies, output powers, DC power dissipations, and optimum fundamental load impedances of the inverse class-F and class-F amplifiers. We also have compared them for various operation conditions, which include the same peak current, saute DC power dissipation, same fundamental RF output power, and same fundamental load impedance with different Ron(on-resistance). These analyses have clearly shown the performance limitations, advantages, and guide to the optimized design of the inverse class-F amplifiers.

The signal analysis of PD in DS for GIS (GIS 단로기 내부의 부분방전 신호분석)

  • Kim, Jong-Seo;Kim, Jin-Tea;Cheon, Min-Ou;Park, No-Bong;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.679-682
    • /
    • 2004
  • GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized accordingly. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this analysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected signals with the application of neural network algorithm.

  • PDF

Analysis of trouble signal of inner DS for GIS (GIS 단로기 내부의 이상신호 분석)

  • Kim, Jong-Seo;Lee, Eun-Suk;Park,, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1207-1210
    • /
    • 2004
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this analysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm

  • PDF