• Title/Summary/Keyword: ApEn

Search Result 30, Processing Time 0.026 seconds

Approximate Entropy of hypertension: Effect of Anesthesia (정상혈압환자와 고혈압환자의 마취전후의 근사엔트로피의 비교)

  • Yum, M.K.;Kim, H.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.368-371
    • /
    • 1996
  • Background: Recently, measure of heart rate variability and the nonlinear "complexity" of heart rate dynamics have been used as indicators of cardiovascular health. Several investigators have demonstrated that heart rate variability decreased in aging, congestive heart failure and coronary heart disease. Because hypertensive patients showed alternation of cardiovascular homeostasis, we designed this study to evaluate the effect of anesthesia in hypertensive patients with approximate entropy (ApEn). Methods: With informed consent, eighteen normotensive patients and eighteen hypertensive patients were given no premedication. ECG data were collected from 10 minutes before induction to 15 minutes after induction. Collected ECG data were stored into computer binary files. We calculated ApEn from the collected ECG data. Results: Before induction, ApEn of hypertensive patients was significantly lower than normotensive patients(p<0.05). During induction and maintain of anesthesia, there was no difference of ApEn between two groups. During induction and maintain of anesthesia, in normotensive group, ApEn was significantly lower than that of preinduction(p<0.05). And ApEn during maintain of anesthesia was lower than that of induction(p<0.05). During maintain of anesthesia, in hypertensive group, ApEn was significantly lower than that of preinduction(p<0.05). Conclusions: Before induction, ApTn of hypertensive patients is significantly lower than normotensive patients. As anesthesia was deepened, ApEn of two groups were decreased. Because the baroreflex of hypertensive patients is already decreased, decreasing of ApEn of hypertensive patients during anesthesia is less than that of normotnesive patients.

  • PDF

Relationship between Center of Pressure and Local Stability of the Lower Joints during Walking in the Elderly Women

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • Objective: The purpose of this study was to determine the relationship between center of pressure (CoP) and local stability of the lower joints, which was calculated based on approximate entropy (ApEn) during walking in elderly women. Method: Eighteen elderly women were recruited (age: $66.4{\pm}1.2yrs$; mass: $55.4{\pm}8.3kg$; height: $1.56{\pm}0.04m$) for this study. Before collecting data, reflective marker triads composed of 3 non-collinear spheres were attached to the lateral surface of the thigh and shank near the mid-segment to measure motion of the thigh and shank segments. To measure foot motion, reflective markers were placed on the shoe at the heel, head of the fifth metatarsal, and lateral malleolus, and were also placed on the right anterior-superior iliac spine, left anterior-superior iliac spine, and sacrum to observe pelvic motion. During treadmill walking, kinematic data were recorded using 6 infrared cameras (Oqus 300, Qualisys, Sweden) with a 100 Hz sampling frequency and kinetic data were collected from a treadmill (Instrumented Treadmill, Bertec, USA) for 20 strides. From kinematic data, 3D angles of the lower extremity's joint were calculated using Cardan technique and then ApEn were computed for their angles to evaluate local stability. Range of CoP was determined from the kinetic data. Pearson product-moment and Spearman rank correlation coefficient were applied to find relationship between CoP and ApEn. The level of significance was determined at p<.05. Results: There was a negative linear correlation between CoP and ApEn of hip joint adduction-abduction motion (p<.05), but ApEn of other joint motion did not affect the CoP. Conclusion: It was conjectured that ApEn, local stability index, for adduction/abduction of the hip joint during walking could be useful as a fall predictor.

Heart Rate Variability and Lipid Profile in Patients with Major Depressive Disorder (주요우울장애 환자에서의 심박변이도와 혈중 지질 농도와의 연관성)

  • Ahn, Eun-Jung;Choi, Jin-Sook;Jang, Yong-Lee;Lee, Hae-Woo;Sim, Hyun-Bo
    • Sleep Medicine and Psychophysiology
    • /
    • v.19 no.1
    • /
    • pp.27-34
    • /
    • 2012
  • Objectives: The analysis of heart rate variability (HRV) is a useful non-invasive tool to investigate the autonomic nerve function. Previous studies on the relationship between HRV and depression have been reported controversial results. Similarly, the correlation between the serum lipids and depression is debatable. The purpose of this study is to examine the relationship between heart rate variability, lipid profile and depression. Methods: A total of 42 patients with major depressive disorder (MDD) and 32 age and sex-matched normal subjects who had no previous history of major medical and mental illnesses were recruited for this study. A structured-interview was used to assess the general characteristics and psychiatric illness. HRV measures were assessed by time-domain and frequency-domain analyses. Psychological symptoms were measured using the Hamilton rating scale for anxiety (HAM-A), Hamilton rating scale for depression (HAM-D). In addition, the evaluation for lipid profile was performed by blood test. Results: In serum lipid profile test, MDD group showed higher cholesterol ($197.68{\pm}42.94$ mg/dL vs. $176.85{\pm}34.68$ mg/dL, p=0.044), TG ($139.45{\pm}92.54$ mg/dL vs. $91.4{\pm}65.68$ mg/dL, p=0.018), LDL ($130.03{\pm}33.18$ vs. $106.62{\pm}27.08$, p=0.004) level than normal control group. In HRV time domain analyses, the standard deviation of the NN interval (SDNN) was decreased in MDD group than normal control group, but was not significant ($32.82{\pm}14.33$ ms vs. $40.36{\pm}21.40$ms, p=0.078). ApEn (Approximate Entrophy) was significantly increased in MDD group than normal control group ($1.13{\pm}0.11$ vs. $0.91{\pm}0.18$, p<0.001). ApEn was correlated with LDL level (r=0.277, p=0.028), HAM-D scores (r=0.534, p<0.001) and HAM-A scores (r=0.470, p<0.001). Conclusions: MDD patients showed increased ApEn, one of the HRV measurement. And this ApEn was correlated with LDL, HAM-D and HAM-A scores. In this study, the analysis of ApEn would be a useful test of MDD.

Complexity Comparison of Center of Pressure between Fallers and Non-fallers during Gait (보행 시 낙상 유무에 따른 압력중심점의 복잡성 비교)

  • Park, Sang Kyoon;Ryu, Sihyun;Kim, Jongbin;Yoon, Sukhoon;Ryu, Jiseon
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.2
    • /
    • pp.113-119
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the effect of the falls on the center of pressure (CoP) complexity during gait using non-linear approximate entropy (ApEn). Method: 20 elderly women with experience of falling ($age=72.55{\pm}5.42yrs$; $height=154.40{\pm}4.26cm$; $body\;weight=57.40{\pm}6.21kg$; $preferred\;gait\;speed=0.52{\pm}0.17m/s$) and 20 elderly women with no experience of falling ($age=71.90{\pm}2.90yrs$; $height=155.28{\pm}4.73cm$; $body\;weight=56.70{\pm}5.241kg$; $preferred\;gait\;speed=0.56{\pm}0.13m/s$) were recruited for the study. While they were walking at their preferred gait speed on a treadmill (instrumented dual belt treadmills, Bertec, USA) with a force plate CoP data were collected for the 20 strides. The complexity of the CoP was analyzed using the ApEn technique. Results: The ApEn of the medial-lateral CoP in the fallers showed smaller about 16% compared to the non-fallers (p<.05). The ApEn of the antero-posterior CoP of the fallers showed smaller about 12% compared to the non-fallers, but the difference was not statistically significant. Conclusion: Based on the results of this study, the reduction of the medio-lateral CoP complexity in the elderly gait would be an index to determine the potential fall.

ESTIMATION OF RHYTHMIC VARIATIONS IN R-R INTERVAL DURING SLEEP

  • Han, J.M.;Lee, J.M.;Nam, Y.H.;Park, H.J.;Park, K.S.;Jeong, Do-Un
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.195-196
    • /
    • 1998
  • Nonlinear energy operator(NEO) is usually used to estimate energy content of linear oscillator. We applied the modified nonlinear energy operator (MNEO) to detect R-peak of ECG and analyzed variation of R-R interval during sleep with nonlinear methods, piecewise correlation dimension and approximate entropy (ApEn) which estimate complexity of time series. ApEn applied to R-R interval reveals trends as sleep state changes.

  • PDF

A Study on the Quantitative Regularity Measures That Are Suitable for Biological Signal Analysis - Standard Data and 24 Hour R-R interval Analysis

  • Nam, Y.H.;Lee, J.M.;Han, J.M.;Park, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.197-198
    • /
    • 1998
  • We tested the capability of Pointwise Correlation Dimension(PD2), Approximate Entropy (ApEn) and LZ complexity, as alternative measures of a biological signal. For this purpose, we analyzed standard data and a healthy child's 24-hour heart rate variability. Our conclusion is as follows. First, PD2, ApEn and LZ complexity can be used for discerning chaotic attractor, white noise, and periodic signal. Second, these measures show different characteristics on day and night. Third, these measures can be used for detecting time-varying characteristics of biological signals.

  • PDF

Finite element modeling of manufacturing irregularities of porous materials

  • Gonzalez, Fernando J. Quevedo;Nuno, Natalia
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.1
    • /
    • pp.1-14
    • /
    • 2016
  • Well-ordered porous materials are very promising in orthopedics since they allow tailoring the mechanical properties. Finite element (FE) analysis is commonly used to evaluate the mechanical behavior of well-ordered porous materials. However, FE results generally differ importantly from experimental data. In the present article, three types of manufacturing irregularities were characterized on an additive manufactured porous titanium sample having a simple cubic unit-cell: strut diameter variation, strut inclination and fractured struts. These were included in a beam FE model. Results were compared with experimental data in terms of the apparent elastic modulus (Eap) and apparent yield strength (SY,ap). The combination of manufacturing irregularities that yielded the closest results to experimental data was determined. The idealized FE model resulted in an Eap one order of magnitude larger than experimental data and a SY,ap almost twice the experimental values. The strut inclination and fractured struts showed the strongest effects on Eap and SY,ap, respectively. Combining the three manufacturing irregularities produced the closest results to experimental data. The model also performed well when applied to samples having different structural dimensions. We recommend including the three proposed manufacturing irregularities in the FE models to predict the mechanical behavior of such porous structures.

The Study of Driving Fatigue using HRV Analysis (HRV 분석을 이용한 운전피로도에 관한 연구)

  • 성홍모;차동익;김선웅;박세진;김철중;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • The job of long distance driving is likely to be fatiguing and requires long period alertness and attention, which make considerable demands of the driver. Driving fatigue contributes to driver related with accidents and fatalities. In this study, we investigated the relationship between the number of hours of driving and driving fatigue using heart rate variability(HRV) signal. With a more traditional measure of overall variability (standard deviation, mean, spectral values of heart rate). Nonlinear characteristics of HRV signal were analyzed using Approximate Entropy (ApEn) and Poincare plot. Five subjects drive the four passenger vehicle twice. All experiment number was 40. The test route was about 300Km continuous long highway circuit and driving time was about 3 hours. During the driving, measures of electrocardiogram(ECG) were performed at intervals of 30min. HRV signal, derived from the ECG, was analyzed using time, frequency domain parameters and nonlinear characteristic. The significance of differences on the response to driving fatigue was determined by Student's t-test. Differences were considered significant when a p value < 0.05 was observed. In the results, mean heart rate(HRmean) decreased consistently with driving time, standard deviation of RR intervals(SDRR), standard deviation of the successive difference of the RR intervals(SDSD) increased until 90min. Hereafter, they were almost unchanging until the end of the test. Normalized low frequency component $(LF_{norm})$, ratio of low to high frequency component (LF/HF) increased. We used the Approximate Entropy(ApEn), Poincare plot method to describe the nonlinear characteristics of HRV signal. Nonlinear characteristics of HRV signals decreased with driving time. Statistical significant is appeared after 60 min in all parameters.

Effects of Head-Up Tilt on Nonlinear Properties of Heart Rate Variability in Young and Elderly Subjects

  • Jin, Seung-Hyun;Kim, Wuon-Shik;No, Ki-Yong
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.1
    • /
    • pp.14-22
    • /
    • 2005
  • In the present study, our aim is to investigate whether responses to the head-up tilt (HUT) on nonlinear properties of heart rate variability (HRV) in young and elderly subjects are different or not. Thirteen young-healthy subjects ($24.5{\pm}3.7$ years) and 18 old-aged healthy subjects ($74.5{\pm}7.4$ years) participated in this study. An electrocardiogram (ECG) in the supine posture, at $0^{\circ}$, and in the standing posture, at $70^{\circ}$ of head-up tilt, was recorded. Detrended fluctuation analysis (DFA) and approximate entropy (ApEn), measures of short-/long-term correlation properties and overall complexity of heart rate (HR) respectively, along with spectral components of HR variability (HRV) were analyzed for both the supine and HUT postures. We observed that the short-term fractal exponent ${\alpha}_1$ increased during HUT posture (F(1, 29) = 39.79, P = 0.000), especially, the young subjects showed a significantly higher values compared to the elderly subjects. ApEn significantly decreased (F(1, 29) = 8.61, P = 0.006) during HUT posture. HUT posture decreased the complexity in HR dynamics and increased short-term fractal exponent values in young subjects but not in elderly subjects. These results imply that there are differences of response to HUT on nonlinear properties between young and elderly subjects.

  • PDF

Inhibitory Effect of 3-(4-Hydroxyphenyl)-1-(thiophen-2-yl) prop-2-en-1-one, a Chalcone Derivative on MCP-1 Expression in Macrophages via Inhibition of ROS and Akt Signaling

  • Kim, Mi Jin;Kadayat, Taraman;Um, Yeon Ji;Jeong, Tae Cheon;Lee, Eung-Seok;Park, Pil-Hoon
    • Biomolecules & Therapeutics
    • /
    • v.23 no.2
    • /
    • pp.119-127
    • /
    • 2015
  • Chalcones (1,3-diaryl-2-propen-1-ones), a subfamily of flavonoid, are widely known to possess potent anti-inflammatory and anti-oxidant properties. In this study, we investigated the effect of 3-(4-Hydroxyphenyl)-1-(thio3-(4-Hydroxyphenyl phen-2-yl)prop-2-en-1-one (TI-I-175), a synthetic chalcone derivative, on endotoxin-induced expression of monocyte chemoattractant protein-1 (MCP-1), one of the key chemokines that regulates migration and infiltration of immune cells, and its potential mechanisms. TI-I-175 potently inhibited MCP-1 mRNA expression stimulated by lipopolysaccharide (LPS) in RAW 264.7 macrophages without significant effect on cell viability. Treatment of cells with TI-I-175 markedly prevented LPS-induced transcriptional activation of activator protein-1 (AP-1) as measured by luciferase reporter assay, while nuclear factor-${\kappa}B$ (NF-${\kappa}B$) activity was not inhibited by TI-I-175, implying that TI-I-175 suppressed MCP-1 expression probably via regulation of AP-1. In addition, TI-I-175 treatment significantly inhibited LPS-induced Akt phosphorylation and led to a significant decrease in reactive oxygen species (ROS) production by LPS, which act as up-stream signaling events required for AP-1 activation in RAW 264.7 macrophages. Taken together, these results indicate that TI-I-175 suppresses MCP-1 gene expression in LPS-stimulated RAW 264.7 macrophages via suppression of ROS production and Akt activation.