• 제목/요약/키워드: Aortic disease

검색결과 463건 처리시간 0.022초

Epidemiologic Profile of Patients With Valvular Heart Disease in Korea: A Nationwide Hospital-Based Registry Study

  • You-Jung Choi;Jung-Woo Son;Eun Kyoung Kim;In-Cheol Kim;Hyung Yoon Kim;Jeong-Sook Seo;Byung Joo Sun;Chi Young Shim;Se-Jung Yoon;Sahmin Lee;Sun Hwa Lee;Jun-Bean Park;Duk-Hyun Kang
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.51-61
    • /
    • 2023
  • BACKGROUND: Valvular heart disease (VHD) is a common cause of cardiovascular morbidity and mortality worldwide; however, its epidemiological profile in Korea requires elucidation. METHODS: In this nationwide retrospective cohort study from the Korean valve survey, which collected clinical and echocardiographic data on VHD from 45 medical centers, we identified 4,089 patients with VHD between September and October 2019. RESULTS: The aortic valve was the most commonly affected valve (n = 1,956 [47.8%]), followed by the mitral valve (n = 1,598 [39.1%]) and tricuspid valve (n = 1,172 [28.6%]). There were 1,188 cases of aortic stenosis (AS) and 926 cases of aortic regurgitation. The most common etiology of AS was degenerative disease (78.9%). The proportion of AS increased with age and accounted for the largest proportion of VHD in patients aged 80-89 years. There were 1,384 cases of mitral regurgitation (MR) and 244 cases of mitral stenosis (MS). The most common etiologies for primary and secondary MR were degenerative disease (44.3%) and non-ischemic heart disease (63.0%), respectively, whereas rheumatic disease (74.6%) was the predominant cause of MS. There were 1,172 tricuspid regurgitation (TR) cases, of which 46.9% were isolated and 53.1% were associated with other valvular diseases, most commonly with MR. The most common type of TR was secondary (90.2%), while primary accounted for 6.1%. CONCLUSIONS: This report demonstrates the current epidemiological status of VHD in Korea. The results of this study can be used as fundamental data for developing Korean guidelines for VHD.

Clinical Implication of Aortic Wall Biopsy in Aortic Valve Disease with Bicuspid Valve Pathology

  • Kim, Yong Han;Kim, Ji Seong;Choi, Jae-Woong;Chang, Hyoung Woo;Na, Kwon Joong;Kim, Jun Sung;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • 제49권6호
    • /
    • pp.443-450
    • /
    • 2016
  • Background: Although unique aortic pathology related to bicuspid aortic valve (BAV) has been previously reported, clinical implications of BAV to aortopathy risk have yet to be investigated. We looked for potential differences in matrix protein expressions in the aortic wall in BAV patients. Methods: Aorta specimens were obtained from 31 patients: BAV group (n=27), tricuspid aortic valve (TAV) group (n=4). The BAV group was categorized into three subgroups: left coronary sinus-right coronary sinus (R+L group; n=13, 42%), right coronary sinus-non-coronary sinus (R+N group; n=8, 26%), and anteroposterior (AP group; n=6, 19%). We analyzed the expression of endothelial nitric oxide synthase (eNOS), matrix metalloproteinase (MMP)-9, and tissue inhibitor of matrix metalloproteinase (TIMP)-2. Results: Based on the mean value of the control group, BAV group showed decreased expression of eNOS in 72.7% of patients, increased MMP-9 in 82.3%, and decreased TIMP in 79.2%. There was a higher tendency for aortopathy in the BAV group: eNOS $(BAV:TAV)=53%{\pm}7%:57%{\pm}11%$, MMP-9 $(BAV:TAV)=48%{\pm}10%:38%{\pm}1%$. The AP group showed lower expression of eNOS than the fusion (R+L, R+N) group did; $48%{\pm}5%$ vs. $55%{\pm}7%$ (p=0.081). Conclusion: Not all patients with BAV had expression of aortopathy; however, for patients who had a suspicious form of bicuspid valve, aortic wall biopsy could be valuable to signify the presence of aortopathy.

전달함수를 이용한 대동맥 맥파 추정 및 증강점 검출 알고리즘 개선에 관한 연구 (Estimation of the Central Aortic Pulse using Transfer Function and Improvement of an Augmentation Point Detection Algorithm)

  • 임재중
    • 전자공학회논문지SC
    • /
    • 제45권3호
    • /
    • pp.68-79
    • /
    • 2008
  • 대동맥 증강지수는 심실의 부하뿐만 아니라 대동맥의 탄력성을 직접적으로 나타낼 수 있는 장점 때문에 동맥의 경직도를 평가하는 지표로 주목받고 있다. 하지만, 정확한 대동맥 증강지수를 계산하기 위해서는 직접 카테터를 피험자에 삽입하여 측정해야 하기 때문에 임상에 적용하기에는 한계가 존재한다. 이러한 문제점 때문에 전달함수를 이용하여 요골 동맥 맥파로부터 대동맥 맥파를 간접적으로 추정하는 방법이 이용되고 있다. 본 논문에서는 전달함수를 구하기 위하여 Millar 카테터를 이용한대동맥 맥파와 토노메트릭 방식의 압력센서를 이용하여 요골동맥 맥파를 측정하였다. 또한, 기존의 증강점 검출 알고리즘 대신단계적으로 미분 차수를 증가시키면서 증강점을 검출하는 새로운 알고리즘을 제안하였다. 10차 ARX 모델을 이용하여 전달함수를 구현하였으며, 잔차 분석을 통하여 모델을 검증하였다. 증강점 검출 알고리즘 검증을 위하여 네 가지 종류의 합성파를 만들어 제안된 알고리즘이 기존 알고리즘 보다 더 정확한 결과를 나타내는 것을 확인할 수 있었다. 본 연구는 쉽게 측정할 수 있는 요골동맥 맥파를 이용하여 대동맥의 경직도를 평가할 수 있는 방법을 제시하였으며 이를 통하여 다양한 심혈관 질환의 조기 진단에 기여할 수 있을 것이다.

대동맥 근부치환술에 대한 Cabrol 술식의 성적 (The Results of using the Cabrol Technique for Aortic Root Replacement)

  • 김정원;이종태;조준용;김규태;김근직
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.573-579
    • /
    • 2008
  • 배경: 대동맥근부의 여러 질환에 있어서 인공판막도관을 이용한 대동맥근부 치환술은 현재 가장 보편적으로 사용되고 있으며, 여러 가지 변형 방법이 소개되고 있다. 그 중 13년간 Cabrol 술식을 이용하여 본원에서 대동맥근부 치환술을 시행하였던 환자들을 대상으로 수술 결과를 분석, 평가하였다. 대상 및 방법: 1994년 1월부터 2006년 12월까지 본원에서 Cabrol 술식을 적용한 25예를 조사 대상으로 하였다. 환자들의 평균연령은 $43.7{\pm}14.1$(6세${\sim}$65세)였으며 성별은 남자 21명, 여자는 4명이었다. 생존한 모든 환자에서 추적관찰이 이루어졌으며, 평균추적관찰기관은 $60.7{\pm}50.4\;(1{\sim}162)$개월이었다. 수술 전 진단은 대동맥판막 폐쇄부전을 동반한 대동맥판륜확장증이 18예로 가장 많았으며, 대동맥판륜확장을 동반한 대동맥박리가 7예 있었다. 결과: 수술사망은 1예(4.0%)가 있었으며 MDCT를 촬영한 9예 중 4예에서 관상동맥문합부의 의미 있는 협착 및 폐색이 확인되었다. 결론: Cabrol 술식은 비록 낮은 수술사망률을 보이나, 관상동맥문합부의 협착 및 폐색 등의 장기 합병증에 대해서는 다소 높은 이완률이 확인되었으며 이에 따라 Cabrol 술식의 적용은 대동맥근부에 대한 재수술 및 대동맥판륜과 관상동맥 입구부가 매우 가까운 경우 등 제한적인 경우에 사용하는 것이 바람직하다고 판단된다.

폐주사(肺走査) - 심장질환(心臟疾患)의 폐관류주사(肺灌流走査) 소견(所見) - (Evaluation of Pulmonary Perfusion Scan in Heart Disease)

  • 이종태;김정규;박창윤;최병숙
    • 대한핵의학회지
    • /
    • 제7권2호
    • /
    • pp.27-34
    • /
    • 1973
  • Pulmonary perfusion scan with radioactive $^{113m}In$-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of mitral stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of atrial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductus arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  • PDF

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • 대한한의학회지
    • /
    • 제30권3호
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

개심술 180례에 대한 임상적 고찰 (Open Heart Surgery:Clinical Analysis of 180 Cases)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • 제27권6호
    • /
    • pp.460-471
    • /
    • 1994
  • Between Feb. 1990 and Aug. 1993, 180 cases of the open heart surgery were performed under cardiopulmonary bypass in the Department of Thoracic & Cardiovascular surgery, Gil General Hospital. There were 83 cases with congenital heart diseases [CHD] and 97 cases with acquired heart diseases [AHD]. The CHD consisted of 78 acyanotic[mortality: 3.8 %] and 5 cyanotic cases with heart anomaly[mortality:l case]. The AHD were 97 cases, which contained 53 valvular, 27 ischemic heart diseases, 10 aortic diseases, 5 cases with myxoma, 1 case with post-infarct VSD, and 1 case with removal of infected pacing wire in right ventricle. In the 53 valvular heart diseases, there were 45 cases with valve replacement[MVR 27, AVR 9,MVR + AVR 9] and 8 cases with valvuloplasty. The number of the implanted prosthetic valves were 53. In MVR, 25 St. Jude, 6 Sorin, 3 Carpentier-Edward and 2 Intact medical valves were used. In aortic position, 13 St. Jude, 3 Sorin and 1 Intact medical valves were applied. The operative mortality was 5.6 % [3/53]. The annuloplasty applying artificial ring was performed in 17 patients[4 cases associated with MVR] and the number of the implanted ring was 19, which included 14 Duran ring[10 mitral, 4 tricuspid] and 5 Carpentier ring [3 mitral, 22 tricuspid]. In the 27 ischemic heart diseases, there were 9 cases with left main coronary artery lesions, 7 one vessel, 5 two vessels, and 6 three vessels. Average number of anastomosis was 2.8 per patient. The operative mortality was 14.3 % [4/27]. Among the 10 patients with aortic diseases, 7 cases were aortic dissection[type A: 5, type B: 2] and 3 cases were descending thoracic aortic aneurysm. The operative morality occurred in 3 cases. The overall mortality and the operative mortality of congenital and acquired heart disease was 7.8 %, 4.8% and 10.4%, respectively.

  • PDF

Mid-Term Results of Using the Seal Thoracic Stent Graft in Cases of Aortopathy: A Single-Institution Experience

  • Cho, Jun Woo;Jang, Jae Seok;Lee, Chul Ho;Hwang, Sun Hyun
    • Journal of Chest Surgery
    • /
    • 제52권5호
    • /
    • pp.335-341
    • /
    • 2019
  • Background: The endovascular approach to aortic disease treatment has been increasingly utilized in the past 2 decades. This study aimed to determine the long-term results of using the Seal thoracic stent graft. Methods: We retrospectively reviewed the outcomes of patients who underwent thoracic endovascular aortic repair or a hybrid procedure using the Seal thoracic stent graft (S&G Biotech, Seongnam, Korea) from January 2008 to July 2018 at a single institution. We investigated in-hospital mortality and the incidence of postoperative complications. We also investigated the mid-term survival rate and incidence of aorta-related complications. Results: Among 72 patients with stent grafts, 15 patients underwent the hybrid procedure and 21 underwent emergency surgery. The mean follow-up period was $37.86{\pm}30.73$ months (range, 0-124 months). Five patients (6.9%) died within 30 days. Two patients developed cerebrovascular accidents. Spinal cord injury occurred in 2 patients. Postoperative renal failure, postoperative extracorporeal membrane oxygenation support, and pneumonia were reported in 3, 1, and 6 patients, respectively. Stent-related aortic complications were observed in 5 patients (6.8%). The 1- and 5-year survival and freedom from stent-induced aortic event rates were 81.5% and 58.7%, and 97.0% and 89.1%, respectively. Conclusion: The use of the Seal thoracic stent graft yielded good mid-term results. Further studies are needed to examine the long-term outcomes of this device.

Outcomes after Mechanical Aortic Valve Replacement in Children with Congenital Heart Disease

  • Joon Young Kim;Won Chul Cho;Dong-Hee Kim;Eun Seok Choi;Bo Sang Kwon;Tae-Jin Yun;Chun Soo Park
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.394-402
    • /
    • 2023
  • Background: The optimal choice of valve substitute for aortic valve replacement (AVR) in pediatric patients remains a matter of debate. This study investigated the outcomes following AVR using mechanical prostheses in children. Methods: Forty-four patients younger than 15 years who underwent mechanical AVR from March 1990 through March 2023 were included. The outcomes of interest were death or transplantation, hemorrhagic or thromboembolic events, and reoperation after mechanical AVR. Adverse events included any death, transplant, aortic valve reoperation, and major thromboembolic or hemorrhagic event. Results: The median age and weight at AVR were 139 months and 32 kg, respectively. The median follow-up duration was 56 months. The most commonly used valve size was 21 mm (14 [31.8%]). There were 2 in-hospital deaths, 1 in-hospital transplant, and 1 late death. The overall survival rates at 1 and 10 years post-AVR were 92.9% and 90.0%, respectively. Aortic valve reoperation was required in 4 patients at a median of 70 months post-AVR. No major hemorrhagic or thromboembolic events occurred. The 5- and 10-year adverse event-free survival rates were 81.8% and 72.2%, respectively. In univariable analysis, younger age, longer cardiopulmonary bypass time, and smaller valve size were associated with adverse events. The cut-off values for age and prosthetic valve size to minimize the risk of adverse events were 71 months and 20 mm, respectively. Conclusion: Mechanical AVR could be performed safely in children. Younger age, longer cardiopulmonary bypass time and smaller valve size were associated with adverse events. Thromboembolic or hemorrhagic complications might rarely occur.

다중 혈관질환에서 심폐바이패스를 이용하지 않은 관상동맥 우회술 ("Off-Pump" Coronary rtery bypass Grafting in Multi-vessel Coronary Disease -Two Cases-)

  • 유원희;김기봉
    • Journal of Chest Surgery
    • /
    • 제32권12호
    • /
    • pp.1123-1126
    • /
    • 1999
  • Coronary artery bypass grafting (CABG) technique has been much developed but CABG under cardiopulmonary bypass has the unavoidable deficits such as generalized inflammatory reaction from cardiopulmonary bypass and myocardial ischemia from aortic-cross clamp. There has been remarkable advancement of CABG without cadiopulmonary bypass. We performed CABG successfully without cardiopulmonary bypass. We performed CABG successfully without cardiopulmonary bypass in two patients with multivessel coronary disease who were failed to intervene with percutaneous transluminal coronary angioplasty. We herein report the two cases.

  • PDF