• 제목/요약/키워드: Annual Load

검색결과 322건 처리시간 0.026초

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

몽골의 가정용 PV-ES 하이브리드 시스템 개발을 위한 연구 (The Study on Development of PV-ES hybrid system for Mongolian Household)

  • ;;박준형
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1905-1912
    • /
    • 2017
  • In recent years, Ulaanbaatar, a capital of Mongolia has witnessed major problem that air quality reaches hazardous level during the winter season. Coal combustion for heating of every house in "Ger" district is main reason. One way to reduce the air pollution is mass usage of electric heater. However, there are several difficulties such as overload and degradation of transformers and other equipment used in distribution and transmission systems as well as power shortage occurrence in evening peak period due to residential consumption. This study aims to contribute for solving the air pollution and power shortage problem in Mongolia. One possible solution could be distributed generation (DG) with photovoltaic (PV) penetration. In this study, PV with energy storage (ES) hybrid system to reduce peak load is analyzed. We proposed the suitable structure of PV-ES hybrid for Mongolian household, and suggested several operation scenarios. Optimal operation algorithm is carried out based on a comparison aspect from economical, grid impact and PV penetration possibility. The economic analyse shows annual income of 520USD, and has a payback period of 8 years for selected scenario. The proposed PV-ES system structure is verified by experimentation set on the building rooftop in city center. The suggested scenario is planned to apply for system in further research.

타입별 풍력 발전기 설치에 따른 민감 부하의 순간전압강하 저감 효과 비교 분석 연구 (A Study of the Mitigating Effect Comparison of Voltage Sags by WTG Types Based on the Concept of Area of Vulnerability)

  • 박세준;윤민한
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1682-1688
    • /
    • 2017
  • In modern society, the number of industrial customers using equipment sensitive particularly to voltage sags is rapidly increasing. As voltage sags can cause loss of information as well as false operation of the control device, it results in the vast economic damage in industrial processes. One way to mitigate voltage sags in the sensitive loads is the installation of distributed generation (DGs) on the periphery of these loads. In addition, renewable energy sources are currently in the spot light as the potential solution for the energy crisis and environmental issues. In particular, wind power generation which is connected to a grid is rising rapidly because it is energy efficient and also economically feasible compared to other renewable energy sources. On the basis of the above information, in this paper, with Wind Turbine Generators (WTGs) installed nearby the sensitive load, the analysis of the mitigating effect comparison by types of WTGs is performed using voltage sag assessment on the IEEE-30 bus test system. That is, the areas of vulnerability according to types of WTGs are expected to be different by how much reactive power is produced or consumed as WTG reactive power capability is related to the types of WTGs. Using the concept of 'Vulnerable area' with the failure rate for buses and lines, the annual number of voltage sags at the sensitive load with the installation of WTGs per type is studied. This research will be anticipated to be useful data when determining the interconnection of wind power generation in the power system with the consideration of voltage sags.

전력계통 안전을 위한 공급예비력 적정수준에 대한 연구 (A Research of Optimum Supply Reserve Levels for Stability of Power System)

  • 안대훈;권석기;주행로;최은재
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.55-61
    • /
    • 2008
  • 최근 전력수요의 높은 증가율로 인하여 전력계통에 가장 안정적으로 전력을 공급하기 위한 적정예비력을 얼마만큼을 가져야 할 것인가? 하는 필요성이 강조되고 있다. 본 연구에서는 연도별 계통규모와 예비력 및 예비율의 변화 풍향 분석을 통하여 계통규모가 증가할수록 적정 예비력은 증가하고 있는 반면에 예비율은 하락하는 추세를 보이고 있는 것을 분석하였다. 이 자료를 관계로 현재시점에서 단기 전력수급전망에 적용되는 공급예비력으로 산정한 600만[kW]는 적정수준이라 여겨진다. 또한 최대전력수요가 5,000만[kW]를 넘어서면서 적정수준인 $10{\sim}12[%]$ 예비율 보다는 적정수준의 예비력을 산정하여 적용하는 것이 전력계통을 경제적이고 안정적으로 운영할 수 있다고 분석되었다.

우리나라 영양사의 일반적 특성과 직무만족도의 관련성에 관한 연구 (Relationships between general characteristics and job satisfaction of the Korean dietician)

  • 문현경;정효지;조정순
    • 대한영양사협회학술지
    • /
    • 제2권2호
    • /
    • pp.181-198
    • /
    • 1996
  • This study was carried out to investigate effects of general characteristics of the Korean dietician on job satisfaction. The subjects were 2987 dieticians who responded to the questionnaire distributed at the annual education program of the Korean Dietetic Association in 1995. The results are followings: 1. The level of the job satisfaction of Korean dieticians was low for payment, work environment, and value achievement as a dietician, while it was relatively high for the relationship with colleagues. The other parts of job satisfaction, such as work load, work contents, supervision by senior, participation of policy decision and etc were above average. 2. Dieticians who were older and/or who had worked longer than others had significantly higher job satisfaction in all fields. 3. Dietician who received college education showed significantly lower job satisfaction in all fields than did dieticians with B.A. and M.A. degree. 4. Dieticians with low position at the work had significantly lower job satisfaction in all fields than had dieticians with higher position.

  • PDF

유전알고리즘을 이용한 하천수질관리모형에 관한 연구 (A Study on the River Water Quality Management Model using Genetic Algorithm)

  • 조재현;성기석
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.453-460
    • /
    • 2004
  • The objective of this research is to develop the water quality management model to achieve the water quality goal and the minimization of the waste load abatement cost. Most of existing water quality management model can calculate BOD and DO. In addition to those variables, N and P are included in the management model of this study. With a genetic algorithm, calculation results from the mathematical water quality model can be used directly in this management model. Developed management model using genetic algorithm was applicated for the Youngsan River basin. To verify the management model, water quality and pollution source of the Youngsan River had been investigated. Treatment types and optimum treatment costs of the existing and planned WWTPs in the baisn were calculated from the model. The results of genetic algorithm indicate that Kwangju and Naju WWTP have to do the advanced treatment to achieve the water quality goal about BOD, DO and TP. Total annual treatment cost including the upgrade cost of existing WWTPs in the Youngsan River basin was about 50.3 billion Won.

일본의 그룹하우스에 관한 사례연구 (A Case Study on one of the Group House for the Elderly in Japan)

  • 안경온;사쿠라이 노리코;타니모토 미찌꼬;다카하시 키요미
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.121-125
    • /
    • 2009
  • The nursing-care insurance system started in April, 2000 in Japan. It was a kind of business opportunities for a lot of private entrepreneurs. They came into this care service business from another type of business rapidly. They opened the pay nursing homes with 24 hour nursing. However, the expense load of the nursing-care insurance system was large, local governments started controlling on total numbers of facilities with 24 hours nursing in 2006. So the group houses besides the pay nursing home without nursing care are paid to attention. The pay nursing home has been often managed by the nursing business. Most of the group houses are managed by community based NPO. This study is a case study by the visit and the interview form for one of the group houses. The group house "Shalom Tsukimino" in Kanagawa started operations comparatively at early time among them. Through the study we recognized that a lot of people were helping the NPO as a community service. So they can manage the group house and people who live there get the services with low cost. They show that they separate residence and nursing and use the community service efficiently. We can find a new direction in this case for the life in elderly.

  • PDF

주암호 유역의 강우사상에 따른 오염물질의 유출특성 (A Study of Comparison of outflow characteristics of pollutants by rainfall event of forest area near Juam lake basin)

  • 김남종;신대윤
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.87-104
    • /
    • 2007
  • The objective of this study is to estimate the load of pollutants caused from the forest area among non-point pollutants within the Juam lake. The surveyed forest area was classified into broad-leaved, conifer, mixed and herbage area by forest tree type. Water quality and flux were investigated under rainfall and non-rainfall, respectively. Then, pollutant loading was evaluated by using the values of unit pollutant loading factor of each point and area of forest zone. Water quality analysis results of runoff by forest tree types were as follows. - Annual BOD, $COD_{Mn}\;and\;COD_{Cr}$ concentration of runoff in conifer area was high, and particle and biological recalcitrant compounds were flowed highly. - SS, T-N and T-P concentration was high in runoff from broad-leaved area, and biological degradable compounds was flowed. - Water quality of water from valley was maintained good under non-rainfall and could be utilized as fresh drinking water. Through water quality standard investigation, a countermeasure establishment was necessary to secure a good quality of drinking water - BOD, $COD_{Mn},\;and\;COD_{Cr}$ concentration of Bo-sung river was higher 1.5 times than other 2 streams, and because of high T-N, and T-P concentration in Songgwang stream, the management for this was necessary.

Local-Generator-Based Virtual Power Plant Operation Algorithm Considering Operation Time

  • Park, Sung-Won;Park, Yong-Gi;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2127-2137
    • /
    • 2017
  • A virtual power plant (VPP) is a system that virtually integrates power resources based on the VPP participating customer (VPC) unit and operates as a power plant. When VPP operators manage resources to maximize their benefits, load reduction instructions may focus on more responsive VPCs, or those producing high profitability, by using VPC resources with high operation efficiency. VPCs may thus encounter imbalance problems during operation. This imbalance in operation time would bring more participation for some VPCs, causing potential degradation of their resources. Such an operation strategy would be not preferable for VPP operators in managing the relationship with VPCs. This issue impedes both continual VPC participation and economical and reliable VPP operation in the long term. An operation algorithm is therefore proposed that considers the operation time of VPC generators for mandatory reduction of power resource consumption. The algorithm is based on constraints of daily and annual operation times when VPP operators of local generators perform capacity-market power transactions. The algorithm maximizes the operator benefit through VPP operations. The algorithm implements a penalty parameter for imbalances in operation times spent by VPC generators in fulfilling their obligations. An evaluation was conducted on VPP operational effects by applying the algorithm to the Korean power market.

관정간 도수통로를 설치한 개방형 지열 시스템의 냉방성능 실험 (Performance Analysis for Open-loop Geothermal System with Spill-way technology by Real-scale Experiment)

  • 김홍교;배상무;남유진;전운;오종현;이병호
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.186-194
    • /
    • 2018
  • A ground-source heat pump system (GSHP) is more energy efficient than other heat-source systems because it uses annual constant underground and water temperatures. Especially, two-well geothermal systems using groundwater as the heat source can achieve higher performance than closed-loop geothermal systems. However, performance of two-well geothermal systems is decreased by occurring overflow according to scale during long-term operations. Therefore, this study presents a two-well pairing geothermal system that controls the groundwater level of a diffusion well. In addition, a two-well pairing geothermal system and an SCW geothermal system were installed, and a comparative analysis of cooling performance depending on system operation under the same load conditions was conducted. The result was that the average heat pump coefficient of performance (COP) of the two-well pairing system was 6.5, and the entire system COP was 4.3.