• Title/Summary/Keyword: Angle of incidence

Search Result 583, Processing Time 0.03 seconds

Multicomponent RVSP Survey for Imaging Thin Layer Bearing Oil Sand (박층 오일샌드 영상화를 위한 다성분 역VSP 탐사)

  • Jeong, Soo-Cheol;Byun, Joong-Moo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.3
    • /
    • pp.234-241
    • /
    • 2011
  • Recently, exploration and development of oil sands are thriving due to high oil price. Because oil sands reservoir usually exists as a thin layer, multicomponent VSP, which has the advantage of the high-resolution around the borehole, is more effective than surface seismic survey in exploring oil sand reservoir. In addition, prestack phase-screen migration is effective for multicomponent seismic data because it is based on an one-way wave equation. In this study, we examined the applicability of the prestack phase-screen migration for multicomponent RVSP data to image the thin oil sand reservoir. As a preprocessing tool, we presented a method for separating P-wave and PS-wave from multicomponent RVSP data by using incidence angle and rotation matrix. To verify it, we have applied the developed wavefield separation method to synthetic data obtained from the velocity model including a horizontal layer and dipping layers. Also, we compared the migrated image by using P-wave with that by using PS-wave. As a result, the PS-wave migrated image has higher resolution and wide coverage than P-wave migrated image. Finally, we have applied the prestack phase-screen migration to the synthetic data from the velocity model simulating oil sand reservoir in Canada. The results show that the PS-wave migrated image describe the top and bottom boundaries of the thin oil sand reservoir more clearly than the P-wave migrated image.

MRI study of temporomandibular joint disorder in orthodontic patients (교정환자에서 MRI를 이용한 측두하악관절 장애의 연구)

  • Kim, Tae-Woo;Byun, Eun-Sun;Baek, Seung-Hak;Chang, Young-Il;Nahm, Dong-Seok;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.235-243
    • /
    • 2000
  • Magnetic resonance imaging(MRI) of the temporomandibular joint(TMJ) is very useful method to diagnose internal derangement of the TMJ because of its high specificity foy identification of condyle-disc relationships. The purpose of this study was to evaluate the existence, incidence and severity o』 internal derangement o』 the TMJ by the MRI of Patients who are suspected to have TMJ disorder. MRI sample was composed of 50 subjects(10 males, 40 females) and the mean age was 22.9 years. 43 subjects of the sample were found to have positive findings. $56\%$ of the subjects with positive findings had ADD(anterior disc displacement) without reduction, and $65\%$ had internal derangement of bilateral joints. Distributions in the types of malocclusion in patients with positive findings, the Angle's classification had shown : the largest $41.9\%$ for Cl II ($39.6\%$ for Cl II div 1 and $2.3\%$ for Cl II div 2), $37.2\%$ for Cl I, $18.6\%$ for Cl III, and $2.3\%$ for the unidentified. $8.6\%$ of the subjects with positive findings had facial asymmetry and $55.8\%$ had openbite. We can conclude that the percentage of Cl II is the highest in patients with internal derangement of the TMJ. Openbite or facial asymmetry is considered to be uncompensated or compensated deformity which results from facial skeleton remodeling in the process of degenerative joint disease(DJD) due to TMJ degeneration. Therefore it is recommended to screen the patients with facial asymmetry or openbite by MRI before the beginning of orthodontic treatment. Differential diagnosis is essential because the tendency of relapse is high after the orthodontic treatment and continuous observation of TMJ is needed in patients with TMJ disorder.

  • PDF

Evaluation of dose delivery accuracy due to variation in pitch and roll (세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가)

  • Jeong, Chang Young;Bae, Sun Myung;Lee, Dong Hyung;Min, Soon Ki;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.239-245
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.

Study on the Limitation of AVO Responses Shown in the Seismic Data from East-sea Gas Reservoir (동해 가스전 탄성파 자료에서 나타나는 AVO 반응의 한계점에 대한 고찰)

  • Shin, Seung-Il;Byun, Joong-Moo;Choi, Hyung-Wook;Kim, Kun-Deuk;Ko, Seung-Won;Seo, Young-Tak;Cha, Young-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.242-249
    • /
    • 2008
  • Recently, AVO analysis has been widely used in oil exploration with seismic subsurface section as a direct indicator of the existence of the gas. In the case of the deep reservoirs like the gas reservoirs in the East-sea, it is often difficult to observe AVO responses in CMP gathers even though the bright spots are shown in the stacked section. Because the reservoir becomes more consolidated as its depth deepens, P-wave velocity does not decrease significantly when the pore fluid is replaced by the gas. Thus the difference in Poisson's ratio, which is a key factor for AVO response, between the reservoir and the layer above it does not increase significantly. In this study, we analyzed the effects of Poisson's ratio difference on AVO response with a variety of Poisson's ratios for the upper and lower layers. The results show that, as the difference in Poisson's ratio between the upper and lower layers decreases, the change in the reflection amplitude with incidence angle decreases and AVO responses become insignificant. To consider the limitation of AVO responses shown in the gas reservoir in East-sea, the velocity model was made by simulation Gorae V structure with seismic data and well logs. The results of comparing AVO responses observed from the synthetic data with theoretical AVO responses calculated by using material properties show that the amount of the change in reflection amplitude with increasing incident angle is very small when the difference in Poisson's ratio between the upper and lower layers is small. In addition, the characteristics of AVO responses were concealed by noise or amplitude distortion arisen during preprocessing. To overcome such limitations of AVO analysis of the data from deep reservoirs, we need to acquire precisely reflection amplltudes In data acquisition stage and use processing tools which preserve reflection amplitude in data processing stage.

Evaluation of Cavity Wall Adaptation of Bulk-fill Resin Composites in Class II Cavities of Primary Molar (유구치 2급 와동에서 bulk-fill 복합레진의 와동적합성 평가)

  • Bae, Youngeun;Shin, Jonghyun;Kim, Shin;Jeong, Taesung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.446-454
    • /
    • 2017
  • Recently, there have been many studies on bulk-fill resin composites. However, studies on the proper materials for pediatric patients are rare. The aim of this study was to compare the cavity wall adaptation of bulk-fill resin composites with conventional resin composite in class II cavities of primary molars using microcomputed tomography (micro-CT). Standardized class II slot cavities were prepared in 80 exfoliated primary molars and randomly divided into 4 groups. The control group was restored with conventional resin composite, Filtek Z-350 XT (FZ), and the three groups were restored with bulk-fill resin composites, Filtek bulk-fill posterior (FB), Tetric N-Ceram Bulk Fill (TNC), Filtek bulk-fill flowable (FBF). All specimens were thermocycled and then immersed in 50% silver nitrate ($AgNO_3$) solution. Micro-CT was used to measure the penetration volume of the total silver nitrate and the degree of cervical marginal leakage and the number, size, and position of the voids were evaluated. The results revealed that the volume of silver nitrate were significantly different between FB and FZ (p < 0.05). The results also revealed that the penetration length of silver nitrate FBF showed statistically lower than the FZ and FB (p < 0.05). There was no significant difference between the groups in number and size of voids. In conventional resin composite, most of the voids were present inside the restoration (83.3%), but the voids in the bulk-fill resin composites incidence were higher in the gingivoaxial angle. The cavity wall adaptation demonstrated in class II restorations of primary molar by new bulk fill resin composites was similar to conventional incremental technique. Bulk-fill resin composites might be an clinical option for a faster restoration in deciduous teeth.

The Error and the Graphical Presentation form of the Binocular Vision Findings (양안시기능 검사 값의 오차와 그래프 양식)

  • Yoon, Seok-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.39-48
    • /
    • 2007
  • The stimulus of accommodation A, the stimulus of convergence C and the prism diopter ${\Delta}$ are reviewed and redefined more obviously. How the A and C are managed in the practice are reviewed and summarized. As a result, the common practical process of the binocular vision findings is most suitable in the case of the $l_c=26.67mm$, where the near distance is measured from the test lens to the near target and its value is 40 cm and the average of the P.D equal to 64 mm. The $l_c$ is the distance between the test lens and the center of rotation. Those values were used at calculating the various values in this paper. The error of the stimulus of accommodation values which are evaluated by the practically used formula (5) are calculated. Where the distance between lens and the principle point of eye is 15.07 mm ($=l_H$). The incremental stimulus of convergence values P' caused by the addition prism $P_m$ are evaluated by the recursion computation method. The P' are varied with the $P_m$, the distance $p_c$ between the prism and the center of rotation, the initial convergence value (or inverse target distance) $C_o$ and the refractive index n of the prism material. The recursion computation method and the other formulas are described in detail. In this paper n=1.7 is used. The two factors by which the P' is increased are exist. The one which is major is the property by which the values of convergence whose unit is ${\Delta}$ are not added in the generally way. The other is the that the actual power of the prism is varied with the angle of incidence light. And the P' is decreased remarkably by an increase in the $p_c$ and $C_o$. The $P^{\prime}/P_m$ are calculated and graphed which are varied with the $p_c$ and $C_o$, where the $P_m=20{\Delta}$, P.D=64 mm and n=1.7. The index n dependence of the $P^{\prime}/P_m$ is negligible (refer to fig. 6). The $p_c$ are evaluated at which the P' equal to the $P_m$ for various $P_m$ (refer to table 1). The actual values of the stimulus of convergence and accommodation which are manipulated simply in the practice are calculated. Two graphical forms are suggested. The one is like as the commonly used one. But the stimulus of convergence and of accommodation values in the practice are positioned at the exact positions when the graphic is made (refer to fig. 9). The other is the form that the incremental stimulus of convergence values caused by the addition prisms are represented at actual positions (refer to fig. 11).

  • PDF

Construction of X-band automatic radar scatterometer measurement system and monitoring of rice growth (X-밴드 레이더 산란계 자동 측정시스템 구축과 벼 생육 모니터링)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.3
    • /
    • pp.374-383
    • /
    • 2010
  • Microwave radar can penetrate cloud cover regardless of weather conditions and can be used day and night. Especially a ground-based polarimetric scatterometer has advantages of monitoring crop conditions continuously with full polarization and different frequencies. Kim et al. (2009) have measured backscattering coefficients of paddy rice using L-, C-, X-band scatterometer system with full polarization and various angles during the rice growth period and have revealed the necessity of near-continuous automatic measurement to eliminate the difficulties, inaccuracy and sparseness of data acquisitions arising from manual operation of the system. In this study, we constructed an X-band automatic scatterometer system, analyzed scattering characteristics of paddy rice from X-band scatterometer data and estimated rice growth parameter using backscattering coefficients in X-band. The system was installed inside a shelter in an experimental paddy field at the National Academy of Agricultural Science (NAAS) before rice transplanting. The scatterometer system consists of X-band antennas, HP8720D vector network analyzer, RF cables and personal computer that controls frequency, polarization and data storage. This system using automatically measures fully-polarimetric backscattering coefficients of rice crop every 10 minutes. The backscattering coefficients were calculated from the measured data at a fixed incidence angle of $45^{\circ}$ and with full polarization (HH, VV, HV, VH) by applying the radar equation and compared with rice growth data such as plant height, stem number, fresh dry weight and Leaf Area Index (LAI) that were collected at the same time of each rice growth parameter. We examined the temporal behaviour of the backscattering coefficients of the rice crop at X-band during rice growth period. The HH-, VV-polarization backscattering coefficients steadily increased toward panicle initiation stage, thereafter decreased and again increased in early-September. We analyzed the relationships between backscattering coefficients in X-band and plant parameters and predicted the rice growth parameters using backscattering coefficients. It was confirmed that X-band is sensitive to grain maturity at near harvesting season.

THE CLINICO-STATISTICAL ANALYSIS OF THE TREATMENT OF THE AMELOBLASTOMA (법랑아세포종의 치료에 관한 임상통계학적 분석)

  • OH, Myoung Chul;Kim, Chin Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.4
    • /
    • pp.253-268
    • /
    • 1993
  • The author studied on the 109 cases of ameloblastoma which had been diagnosed with biopsy during the period of 1962 to 1992 at the Kyungpook National University Hospital, Kyemyung University Hospital, Youngnam University Hospital, Catholic Medical School Hospital, Pusan National University and Maryknoll Hospital. This study contains the statistical analysis of the treatment method according to the clinicopathological findings such as sex, age, location, chief complaints, duration, radiographic findings, size and recurrence. The results were as follows : 1. The incidence rate was 59.7% in male and 40.3% in female. 2. At the time of diagnosis, the age of the patients ranged from 9 to 69 years(average 31.4years). The cases of 72.4% were in the 2nd, 3rd, and 4th decades of life. 3. The majority of cases occurred in the mandible 88.9%, especially in the mandiblar angle area 57.8%. 4. The most prevalent chief complaints was swelling 58.7%. 5. As regards duration, the cases less than 1 year appeared 49.5% and average duration is 31.34months. 6. Unilocular type showed 43.1% and multilocular type appeared 56.9%. 7. Conservative treatment was performed 39.4% and radical treatment was employed 60.6%. 8. There were variations of lesional sizes between 2.0cm and 15cm(average 6.26cm). 9. The recurrence rate is 29.4%. 10. The frequency of treatment was not in association with sexes, locations, chief complaints and sizes. 11. Radical treatment was performed more frequently in cases of older age group(above 20 years old), multilocular cases, above average duration(31.34 months) group and recurrent cases (P<0.05).

  • PDF

Oceanic Application of Satellite Synthetic Aperture Radar - Focused on Sea Surface Wind Retrieval - (인공위성 합성개구레이더 영상 자료의 해양 활용 - 해상풍 산출을 중심으로 -)

  • Jang, Jae-Cheol;Park, Kyung-Ae
    • Journal of the Korean earth science society
    • /
    • v.40 no.5
    • /
    • pp.447-463
    • /
    • 2019
  • Sea surface wind is a fundamental element for understanding the oceanic phenomena and for analyzing changes of the Earth environment caused by global warming. Global research institutes have developed and operated scatterometers to accurately and continuously observe the sea surface wind, with the accuracy of approximately ${\pm}20^{\circ}$ for wind direction and ${\pm}2m\;s^{-1}$ for wind speed. Given that the spatial resolution of the scatterometer is 12.5-25.0 km, the applicability of the data to the coastal area is limited due to complicated coastal lines and many islands around the Korean Peninsula. In contrast, Synthetic Aperture Radar (SAR), one of microwave sensors, is an all-weather instrument, which enables us to retrieve sea surface wind with high resolution (<1 km) and compensate the sparse resolution of the scatterometer. In this study, we investigated the Geophysical Model Functions (GMF), which are the algorithms for retrieval of sea surface wind speed from the SAR data depending on each band such as C-, L-, or X-band radar. We reviewed in the simulation of the backscattering coefficients for relative wind direction, incidence angle, and wind speed by applying LMOD, CMOD, and XMOD model functions, and analyzed the characteristics of each GMF. We investigated previous studies about the validation of wind speed from the SAR data using these GMFs. The accuracy of sea surface wind from SAR data changed with respect to observation mode, GMF type, reference data for validation, preprocessing method, and the method for calculation of relative wind direction. It is expected that this study contributes to the potential users of SAR images who retrieve wind speeds from SAR data at the coastal region around the Korean Peninsula.

Evaluation of superficial dose for Postmastectomy using several treatment techniques (유방전절제술을 시행한 환자에서 치료기법에 따른 피부선량 평가)

  • Song, Yong Min;Choi, Ji Min;Kim, Jin Man;Kwon, Dong Yeol;Kim, Jong Sik;Cho, Hyun Sang;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.225-232
    • /
    • 2014
  • Purpose : The purpose of this study was to evaluate the surface and superficial dose for patients requiring postmastectomy radiation therapy(PMRT) with different treatment techniques. Materials and Methods : Computed tomography images were acquired for the phantom(I'mRT, IBA) consisting of tissue equivalent material. Hypothetical chestwall and lung were outlined and modified. Five treatment techniques(Wedged Tangential; WT, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL) were evaluated using only 6MV photon beam. GafChromic EBT3 film was used for dose measurements at the surface and superficial dose. Surface dose profiles around the phantom were obtained for each treatment technique. For superficial dose measurements, film were used inside the phantom and analyzed superficial region for depth from 1-6mm. Results : TOMO DIRECT showed the highest surface dose by 47~70% of prescribed dose, while 7-field IMRT showed the lowest by 35~46% of prescribed dose. For the WT, 4-field IMRT and 7-field IMRT, superficial dose were measured over 60%, 70%, and 80% for 1mm, 2mm, and 5mm depth, respectively. In case of TOMO DIRECT and TOMO HELICAL, over 75%, 80%, and 90% of prescribed dose was measured, respectively. Surface and superficial dose range were uniform in overall chestwall for the 7-field IMRT and TOMO HELICAL. In contrast, Because of the dose enhancement effect with oblique incidence, The dose was gradually increased toward the obliquely tangential angle for the WT and TOMO DIRECT. Conclusion : For PMRT, TOMO DIRECT and TOMO HELICAL deliver the higher surface and superficial doses than treatment techniques based linear accelerator. It showed adequate dose(over 75% of prescribed dose) at 1mm depth in skin region.