• Title/Summary/Keyword: Angle at

Search Result 9,052, Processing Time 0.041 seconds

Analysis Study on the Damage of Crack Happening with the Bending at CFRP Plate due to Stacking Angle (적층각도에 따른 CFRP 평판에서의 굽힘으로 발생한 크랙 파손에 관한 해석적 연구)

  • Hwang, Gue-wan;Cho, Jae-ung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.185-190
    • /
    • 2017
  • This study investigates the bending stress, shear stress and deformation energy happening at the inner fiber structure when the bending moment is applied to he specimen with flat shape composed of carbon fiber. As CFRP is composed of innumerable fibers with multi-axes, the stress under bending condition can be effectively distributed. Theses stresses is shown to increase again at the starting point as this angle of $60^{\circ}$. Therefore, the condition at the stacking angle of $60^{\circ}$ is seen to become most adequate under the state where the bending stress happens. On the basis of this study result, the damage property by the bending at the plate due to stacking angle was examined through the analytic approach. it is thought that this study can be devoted to the safe design for damage prevention and durabilty improvement. Also, the esthetic sense can be shown as the designed factor of shape with flat plate is grafted onto the convergence technique.

Effect of length of alkyl chain consisting of fluorine and carbon in self-assembled monolayers

  • Park, Sang-Geon;Lee, Won Jae;Lee, Won Jae;Kim, Tae Wan
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2018
  • We investigated the interfacial properties of fluorocarbon self-assembled monolayers (FC-SAMs) with different alkyl chain lengths. It was found that the substrate characteristics were changed rapidly with the fabrication time and temperature of the SAM. FC-3SAM, which has the shortest alkyl chain in this study, showed a contact angle of $54.1^{\circ}$ when it was fabricated in an electric oven at $60^{\circ}C$ for the first minute. The FC-3SAM showed a contact angle of up to $76.9^{\circ}$ when it was fabricated in an electric oven at the same temperature condition for 180 minutes. FC-10SAM, which has the longest alkyl chain in this study, showed a contact angle of $64.7^{\circ}$ when it was fabricated at a temperature condition of $60^{\circ}C$ for 1 minute, and a contact angle of $98.7^{\circ}C$ at a temperature condition of $60^{\circ}C$ for 180 minutes. It was found that the FC-10SAM shows an increased contact angle and hydrophobic properties due to a well-aligned molecular structure resulting from a strong van der Waals force. In contrast, the FC-3SAM shows a small contact angle due to the intermolecular disorder resulting from a weak van der Waals force. The average roughness of FC-SAMs was investigated using AFM. The surface roughness of FC-SAMs, which verifies the results of contact angle, was confirmed. At a fabrication time of 120 minutes, the FC-10SAM showed an improvement in average roughness by 62% compared to that of FC-3SAM due to its good alignment.

An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades (피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구)

  • Chang, Taek-Soon;Hur, Jin-Huek;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.5 no.1
    • /
    • pp.45-50
    • /
    • 2009
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}$, $-16^{\circ}$, $-21^{\circ}$, $-26^{\circ}$, $-31^{\circ}$ and $-36^{\circ}$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}$ has been selected to get largest flow rate at backward flow situation.

  • PDF

Effects of UV light irradiation condition and imidization temperature for the generation of pretilt angle on polyimide surfaces (폴리이미드 표면에서의 프리틸트각 발생에 대한 UV조사 조건과 이미드화온도의 영향)

  • Yu, Mun-Sang;Seo, Dae-Shik;Hwang, Jeoung-Yeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.61-64
    • /
    • 1998
  • We have investigated the effects of ultraviolet (UV) light irradiation condition and imidization temperature for the generation of pretilt angle in nematic liquid crystal (NLC) on the two kinds of the polyimide (PI) surfaces. High pretilt angle of NLC is generated with oblique p-polarized UV light irradiation of 30$^{\circ}$ on PI surface for 20 min. Also, the high pretilt angle of NLC is generated with oblique p-polarized UV light irradiation of 10-30$^{\circ}$ on PI surface at 20min. The pretilt angle of NLC decreases with increasing the imidization temperature on all rubbed PI surfaces ; the pretilt angle of NLC with oblique p-polarized UV light irradiation of 30$^{\circ}$on PI surface decreases with increasing the imidization temperature. The high pretilt angle of NLC is observed due to high photo-depolymerization reaction by low surface energy at low imidization temperature. We suggest that the pretilt angle of NLC is strongly attributed to the photo-depolymerization reaction with the UV light irradiation condition and imidization temperature.

  • PDF

Effects of EMG-Biofeedback Training on Functional Ability and Q-angle in Patellofemoral Pain Syndrome (근전도-생체되먹임 훈련이 무릎넙다리통증의 기능적 능력과 Q-각에 미치는 영향)

  • Park, Seung-Kyu;Kang, Jae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.68-73
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of closed kinetic chain exercise using EMG-biofeedback for selective training of the vastus medialis oblique on functional ability and Q-angle in subjects with patellofemoral pain syndrome. Methods: Thirty participants who met the criteria were included in this study. Participants were randomly allocated to the control group (Group I, n=10), closed kinetic chain exercise group (Group II, n=10), and closed kinetic chain exercise using EMG-biofeedback group (Group III, n=10). Intervention was performed in three groups, three times per week, for a period of six weeks. Kujala patellofemoral score and Q-angle were measured before and after the experiment. Results: Some significant differences in kujala patellofemoral score were observed in group II and group III, compared with group I (p<0.01). There was no significant difference on in Q-angle at knee flexion angle $0^{\circ}$. However, some significant differences in Q-angle at knee flexion $60^{\circ}$ were observed in group III, compared with group I (p<0.01). Conclusion: Closed kinetic chain exercise using EMG-biofeedback that provides real-time biometric information on selected muscles in order to increase the efficiency of treatment may be helpful in improvement of functional ability and Q-angle in patellofemoral pain syndrome.

Design Parameter Analysis on the Performance and Noise of Axial Fan (축류형 홴 성능 및 소음에 영향을 미치는 설계변수 분석)

  • 김기황;이승배;주재만
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.275-281
    • /
    • 2001
  • While basic input parameters for the performance and noise of axial fan are flow rate, pressure rise, rotating speed, and fan diameter, the geometric parameters of blade are sweep angle, solidity, and camber angle. The sweep angle does not affect fan performance much, but on fan noise significantly. Solidity and camber angle are very critical design parameters acting on the fan performance directly. The solidity and camber angle are closely related, therefore they have to be carefully determined for the low-noise and high-performance fan. In This paper, different design points are selceted and also geometric parameters are deliberately changed for the comparison of fan noise. As a result, at the same performance, the input rotational speed affects radiated noise more significantly than others. When solidity and camber angle are increased more than those by iDesignFan/sup TM/ program, more noise is experienced. The blade sweep method and blade numbers at same solidity are observed to results in different levels of performance and noise.

  • PDF

Effect of Inlet Valve Angle on In-Cylinder Swirl Generation Characteristics(I) (흡입밸브 각이 실린더 내 와류 발생 특성에 미치는 영향(I))

  • Ohm, In-Yong;Park, Chan-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.148-156
    • /
    • 2008
  • This paper is the first of 2 companion papers which investigate in-cylinder swirl generation characteristics according to inlet valve angle. Two DOHC 4 valve engines, one has wide intake valve angle and the other has narrow valve angle, were used to compare the characteristics of swirl motion generation in the cylinder. One intake port was deactivated to induce swirl flow. A PIV (Particle Image Velocimetry) was applied to measure in-cylinder velocity field according to inlet valve angle during intake stroke. The results show that the stronger swirl motion is observed in wide valve angle engine at the early intake stage; however, the swirl motion is gradually distorted by the intake flow component passing through valve area near the cylinder wall as the stroke proceeds. The tumble motion also does so in wide angle. On the contrary, the swirl and tumble motions, which are not clear at the initial stage, become better and better arranged as the piston goes down and up again after bottom dead center.

An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades (피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구)

  • Chang, Taek-Soon;Hur, Jin-Huek;Moon, Seung-Jae;Lee, Jae-Heon;You, Ho-Sun;Im, Yun-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.145-150
    • /
    • 2008
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}C$, $-16^{\circ}C$, $-21^{\circ}C$, $-26^{\circ}C$, $-31^{\circ}C$ and $-36^{\circ}C$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}C$ has been selected to get largest flow rate at backward flow situation.

  • PDF

The Comparison of Characteristics of Trunk Motion between Energy Walking and Normal Walking (에너지보행과 일반보행에서 몸통운동의 특성 비교)

  • Shin, Je-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.133-145
    • /
    • 2007
  • The purpose of this paper was to compare of difference between energy walking and normal walking. Subjects were selected 8 male undergraduates. The kinematic variables of a pelvis and a thorax were analysed at the take off and contact with 3d cinematography. In addition to the variables, the phase plot angle was calculated in order to definite characteristics in the phase space. The pelvic angle and angular velocity showed significant differences in the flexion/extension between two walking patterns. The pelvic angle and angular velocity were increasing when walking speed was increasing and magnitude of the variables of energy walking was larger than corresponding values for normal walking. On the other hand, the thoracic angle demonstrated significant differences in the flexion/extension and rotation between two walking patterns. The angles of energy walking were smaller in the flexion/extension and were larger in the rotation than the angle of normal walking. The kinematic characteristics of energy walking were also showed clearly significant differences in the range of motion and the relative angle of the trunk. The angle of phase plot only showed demonstrated a significant difference in the rotation at contact between the two walking patterns.

Effects of Body-Adhesive Backpack Condition on Craniovertebral Angle, Sagittal Shoulder Angle and Muscle Fatigue

  • Son, Jinkyu;Kim, Ho;Shin, Wonseob
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.4
    • /
    • pp.2203-2211
    • /
    • 2020
  • Background: Backpacks are one of the most widely used accessories in modern society. However, previous studies have shown that carrying a backpack can cause various musculoskeletal problems. Objectives: To investigate the effects of a body-adhesive backpack on craniovertebral angle, sagittal shoulder angle and the muscle fatigue in the upper extremity. Design: Randomized cross-over design. Methods: For this study, 36 healthy university students participated in this study. The experiment was conducted three times using common backpack, and body-adhesive backpack condition. The angles of the cervical spine and shoulder joints of the subjects were calculated without the backpack. Electrodes were placed at upper trapezius, lower trapezius, rectus abdominis and erector spinae to check for muscle fatigue. Subjects carried a backpack and walked on a treadmill for 15 minutes at 4 km/h. The muscle fatigue signal was also measured while walking. After walking, the craniovertebral and sagittal shoulder angles were measured again while subjects carried backpack. Results: As a result of this study, body-adhesive backpack condition showed significant decrease and significant increase in craniovertebral angle and sagittal shoulder angle than common backpack (P<.05). Body-adhesive backpack condition showed significant decrease in upper trapezius, lower trapezius, erector spinae, and rectus abdominis when compared to a common backpack (P<.05). Conclusion: This study suggests that a body-adhesive backpack is more beneficial in correcting body posture than a common backpack.