• Title/Summary/Keyword: Angiography and Interventional Radiology

Search Result 41, Processing Time 0.028 seconds

Serious Blood-Brain Barrier Disruption after Coil Embolization of Unruptured Intracranial Aneurysm : Report of Two Cases and Role of Immediate Postembolization CT Scan

  • Lee, Kyung-Kyu;Kang, Dong-Hun;Kim, Yong-Sun;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.45-47
    • /
    • 2011
  • Abnormal contrast enhancement on brain computed tomography (CT) scan after diagnostic or interventional angiography is not rare, and has known to be induced by temporary blood-brain barrier (BBB) disruption from contrast media. Furthermore, it has been regarded as clinically subtle, but reported to have no symptom or mild transient symptoms. However, we recently experienced two cases of serious BBB disruption during the acute period after coiling of an unruptured intracranial aneurysm. One patient presented with an unruptured paraclinoid internal carotid artery (ICA) aneurysm on the right and the other with an unruptured right supraclinoid ICA aneurysm. Both patients showed similar findings on immediate postembolization CT scan and clinical courses after coiling. Typical radiological, clinical characteristics of BBB disruption were described. In addition, the role of immediate postembolization CT scan are also discussed.

Delayed Bilateral Common Femoral Pseudoaneurysm after Percutaneous Access with Interventional Management: A Case Report (경피적 접근을 통한 시술 후에 발생한 지연성 양측 총대퇴 가성동맥류 및 인터벤션 치료: 증례 보고)

  • Sang Hoon Lee;Doo Ri Kim;Jeong Sub Lee;In Chul Nam;Su Yeon Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.705-712
    • /
    • 2023
  • Common femoral artery pseudoaneurysm is a potentially serious complication of peripheral angiography. There have been few prior reports of simultaneous pseudoaneurysm in both common femoral arteries after percutaneous access. Here we report the case of a 58-year-old male patient who presented with phlegmon or abscess a few days after bilateral femoral access, after which newly developed bilateral femoral pseudoaneurysm with wide neck was observed on CT angiography 2 months after infection treatment. Because the patient refused surgery for pseudoaneurysm, a stent-graft was inserted in the left side, and percutaneous thrombin injection under US guidance with balloon occlusion was performed for the right side. Most pseudoaneurysms occur immediately after the causative procedure. However, there have been some cases in which pseudoaneurysms may occur several weeks or months later; it is therefore necessary to check the risk factors and to carefully observe the hemostasis site.

Current Strategy in Endovascular Management for Below-the-Knee Arterial Lesions (무릎 밑 동맥의 혈관 내 치료의 최신 지견)

  • Kyosoo Hwang;Sang Woo Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.541-550
    • /
    • 2021
  • The below-the-knee arterial tree is the thinnest of all the leg vessels and is an important path for blood flow to the foot. Hence, lesions including stenosis, especially obstruction, may lead to critical limb ischemia which represents the most severe clinical manifestation of peripheral arterial disease. It is characterized by the presence of ischemic rest pain, ischemic lesions, or gangrene attributable to the objectively proven arterial occlusive disease. Typically, the atherosclerotic disease process involving the below-the-knee arterial tree is diffuse in the majority of patients. The cornerstone of therapy is vascular reconstruction and limb salvage. Revascularization should be attempted whenever technically possible, without delay, in patients presenting critical limb ischemia and when the clinical status is not hopelessly non-ambulatory. Therefore, endovascular treatment can become the gold standard for the full range of patients including below-the-knee, limiting the clinical role of the classically trained surgeons.

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

Favorable Aortic Remodeling Following Serial False Lumen Procedures in a Case of Chronic Type IIIb Dissection

  • Eleshra, Ahmed Sameh;Heo, Woon;Lee, Kwang-Hun;Lee, Shin-Young;Lee, Ha;Song, Suk-Won
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.286-289
    • /
    • 2018
  • We report a case of acute type I aortic dissection in which an emergency graft replacement of the ascending aorta and innominate artery was performed. We performed false lumen thrombosis through hybrid thoracic endovascular aortic repair to seal the primary entry tear, followed by false lumen obliteration at the level of the descending thoracic aorta, abdominal aorta, and right common iliac artery. Over a period of 4.5 years, we used Amplatzer vascular plugs and coils based on our computed tomography angiography follow-up protocol.

A Study on Evaluation of Portal Vein by Utilizing MIP Reconstruction in the PC Environment after Abdomen CT of Hepatic Artery Embolization Patients (간동맥 색전술 환자의 복부단층촬영 후 PC 환경에서 MIP재구성영상을 이용한 간문맥평가에 관한 고찰)

  • Kim, Young-Keun;Jang, Young-Ill;Heo, Young-Nam
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.13-17
    • /
    • 2001
  • When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the Patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method nay prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography.

  • PDF

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Non-Operative Management with Angioembolization of Grade IV and V Renal Injuries in a Hybrid Emergency Room System

  • Ahn, So Ra;Seo, Sang Hyun;Lee, Joo Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2021
  • Renal injuries occur in more than 10% of patients who sustain blunt abdominal injuries. Non-operative management (NOM) is the established treatment strategy for lowgrade (I-III) renal injuries. However, despite some evidence that NOM can be successfully applied to high-grade (IV, V) renal injuries, it remains unclear whether NOM is appropriate in such cases. The authors report two cases of high-grade renal injuries that underwent NOM after embolization in a hybrid emergency room (ER) system with a 24/7 in-house interventional radiology (IR) team. A 29-year-old male visited Wonkwang University Hospital Regional Trauma Center complaining of right abdominal pain after being hit by a rope. Computed tomography (CT) was performed 16 minutes after arrival, and the CT scan indicated a grade V right renal injury. Arterial embolization was initiated within 31 minutes of presentation. A 56-year-old male was transferred to Wonkwang University Hospital Regional Trauma Center with a complaint of right flank pain. He had initially presented to a nearby hospital after falling from a 3-m height. Thanks to the key CT images sent from the previous hospital prior to the patient's arrival, angiography was performed within 8 minutes of the patient's arrival and arterial embolization was completed within 25 minutes. Both patients were treated successfully through NOM with angioembolization and preserved kidneys. Hematoma in the first patient and urinoma in the second patient resolved with percutaneous catheter drainage. The authors believe that the hybrid ER system with an in-house IR team could contribute to NOM and kidney preservation even in high-grade renal injuries.

Emergency angioembolization performed in a hemodynamically unstable patient with grade V liver injury: The benefit of emergency angioembolization without computed tomography (혈역학적으로 불안정한 grade V 간손상에서 시행한 응급 혈관색전술: 전산화단층 촬영 없이 시행한 응급 혈관색전술의 이점)

  • Kang, Wu Seong;Park, Chan Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.235-239
    • /
    • 2019
  • High-grade liver injury is associated with high morbidity and mortality rates. We report successful emergency angioembolization and early interventional radiology support to manage a high-grade liver injury in a 29-year-old man who presented following a fall during parachute training. Upon arrival, his blood pressure was 80/40 mmHg, and emergency ultrasonography showed a liver injury with perihepatic fluid collection. The patient's blood pressure reduced to 60/40 mmHg, and emergency angiography was performed without computed tomography (CT) (door to puncture time 36 min). After angioembolization, his blood pressure returned to 120/77 mmHg. Subsequent CT revealed no additional bleeding or hollow viscus injury. He was admitted to the Intensive Care Unit and discharged without complications 30 days after admission. In this case, emergency angioembolization (without performing CT) could successfully and safely treat a hemodynamically unstable patient with a high-grade liver injury.

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.