• 제목/요약/키워드: Analytical mode

검색결과 940건 처리시간 0.026초

Finite element model updating of Kömürhan highway bridge based on experimental measurements

  • Bayraktar, Alemdar;Altunisik, Ahmet Can;Sevim, Baris;Turker, Temel
    • Smart Structures and Systems
    • /
    • 제6권4호
    • /
    • pp.373-388
    • /
    • 2010
  • The updated finite element model of K$\ddot{o}$m$\ddot{u}$rhan Highway Bridge on the Firat River located on the $51^{st}$ km of Elazi$\breve{g}$-Malatya highway is obtained by using analytical and experimental results. The 2D and 3D finite element model of the bridge is created by using SAP2000 structural analyses software, and the dynamic characteristics of the bridge are determined analytically. The experimental measurements are carried out by Operational Modal Analysis Method under traffic induced vibrations and the dynamic characteristics are obtained experimentally. The vibration data are gathered from the both box girder and the deck of the bridge, separately. Due to the expansion joint in the middle of the bridge, special measurement points are selected when experimental test setups constitute. Measurement duration, frequency span and effective mode number are determined by considering similar studies in literature. The Peak Picking method in the frequency domain is used in the modal identification. At the end of the study, analytical and experimental dynamic characteristic are compared with each other and the finite element model of the bridge is updated by changing some uncertain parameters such as material properties and boundary conditions. Maximum differences between the natural frequencies are reduced from 10% to 2%, and a good agreement is found between natural frequencies and mode shapes after model updating.

Finite element model updating of an arch type steel laboratory bridge model using semi-rigid connection

  • Altunisik, Ahmet Can;Bayraktar, Alemdar;Sevim, Baris;Kartal, Murat Emre;Adanur, Suleyman
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.541-561
    • /
    • 2010
  • This paper presents finite element analyses, experimental measurements and finite element model updating of an arch type steel laboratory bridge model using semi-rigid connections. The laboratory bridge model is a single span and fixed base structure with a length of 6.1 m and width of 1.1m. The height of the bridge column is 0.85 m and the maximum arch height is 0.95 m. Firstly, a finite element model of the bridge is created in SAP2000 program and analytical dynamic characteristics such as natural frequencies and mode shapes are determined. Then, experimental measurements using ambient vibration tests are performed and dynamic characteristics (natural frequencies, mode shapes and damping ratios) are obtained. Ambient vibration tests are performed under natural excitations such as wind and small impact effects. The Enhanced Frequency Domain Decomposition method in the frequency domain and the Stochastic Subspace Identification method in the time domain are used to extract the dynamic characteristics. Then the finite element model of the bridge is updated using linear elastic rotational springs in the supports and structural element connections to minimize the differences between analytically and experimentally estimated dynamic characteristics. At the end of the study, maximum differences in the natural frequencies are reduced on average from 47% to 2.6%. It is seen that there is a good agreement between analytical and experimental results after finite element model updating. Also, connection percentages of the all structural elements to joints are determined depending on the rotational spring stiffness.

헬리콥터 비행 제어시스템의 피드백 제어 이득 한계에 대한 로터 플랩 동역학의 영향성 분석 (Analytical Investigation of the Influence of Rotor Flap Dynamics on Helicopter Flight Control System Feedback Gain Limit)

  • 양창덕;이승덕;정동우
    • 한국항공우주학회지
    • /
    • 제48권3호
    • /
    • pp.217-224
    • /
    • 2020
  • 고-대역폭(High Bandwidth)의 헬리콥터 반응특성을 위한 높은 수준의 피드백 제어 게인의 사용은 로터 모드에 의해 항공기의 불안정성이 증가한다. 본 논문에서는 EC155B1 헬리콥터 모델링을 수행하고 이를 이용하여 롤 축의 각속도 및 자세 피드백 게인의 증가에 따른 항공기의 안정성을 분석하였다. 그리고 로터 플랩 모드에 의해 제한되는 롤 축 각속도 및 자세 피드백 제어 게인을 검토하였다. 또한 노이즈 제거 필터의 사용으로 비행 제어시스템의 위상지연이 증가 시 헬리콥터 안정성에 영향을 주는 피드백 제어 게인의 한계를 검토하였다.

강합성 데크 트러스 보도교의 자유진동해석 및 상시진동실험에 관한 연구 (Free and Ambient Vibration of Steel-Deck Truss Bridge)

  • 정성엽;오순택
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권4호
    • /
    • pp.60-68
    • /
    • 2012
  • 본 연구에서는 미국 뉴욕주 로체스터시 소재 강합성 데크 트러스 보도교를 대상으로 사용성을 평가하기 위한 상시진동 실험(ambient vibration test)을 수행하였고 이를 해석적 방법에 의한 결과와 비교하였다. 교량전체에 대한 상시진동실험은 수치모델 작성 시 도입되는 여러 가정들에 대한 타당성을 평가하는데 있어서 유용한 방법이며, 교량의 고유진동수나 모드형상과 같이 구조 동력학에서 중요한 구조적인 변수를 결정하는데 있어 중요한 역할을 한다. 본 연구에서는 교량의 수직방향 및 수평방향 진동 특성과 변위를 측정하기 위하여 실제 교량에서 보행자에 의해 발생하는 진동을 입력하중으로 사용하였다. 교량 구조물에 대한 모델링을 위하여 3차원 유한 요소법을 사용하여 해석을 수행하였으며, 이를 통하여 현장실험 결과와의 유효성을 입증하였다.

Development and Validation of an LC-MS/MS Method for Determination of Damaurone D in Rat Plasma and its Application to Pharmacokinetic Study in Rats

  • Lee, Wonpyo;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • 제10권1호
    • /
    • pp.38-42
    • /
    • 2019
  • Damaurone D belongs to the genus Rosa and is a traditional medicinal product used for the treatment of depression, inflammation, and infectious diseases. The purpose of this study was to develop a simple liquid chromatography-tandem mass spectrometry method for the detection of damaurone D in rat plasma and to demonstrate its application in pharmacokinetic studies. Damaurone D and berberine (internal standard) were extracted with acetonitrile using a protein precipitation method. Mass transition was monitored in multiple reaction monitoring mode at m/z $323.2{\rightarrow}267.0$ for damaurone D and m/z $336.1{\rightarrow}320.0$ for berberine in positive ion mode. Analytical validation was conducted by evaluating the specificity, linearity, accuracy, precision, matrix effect, extraction recovery, and stability. The calibration curves were linear over 2-1000 ng/mL. The intra- and inter-day precision and accuracy of quality control samples were 4.79-13.33% and 86.23-102.75%, respectively. The matrix effect and extraction recovery were 96.11-98.47% and 96.11-102.25%, respectively. In the pharmacokinetic study after intravenous administration of damaurone D at a dose of 3 mg/kg in rats, the area under the curve and clearance of damaurone D in rat plasma were $16750.26{\pm}2676.10min{\cdot}ng/mL$ and $182.44{\pm}31.36mL/min/kg$, respectively.

자유단 혹은 노드점에 작용하는 스프링과 부가질량을 받는 일단 지지보의 고유진동수 (Eigen-Frequency of a Cantilever Beam Restrained with Added Mass and Spring at Free End or a Node Point)

  • 심우건
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.32-40
    • /
    • 2018
  • 열 교환기/원자로의 과도한 진동을 방지 하려면 진동해석을 설계 단계에서 수행해야 한다. 진동 문제에서 고유 진동수의 정보는 열 교환기/원자로의 안전성을 평가하기 위하여 요구된다. 본 논문은 일단 지지보에 발생되는 고유치 문제를 해석하기 위하여 수치해석 방법인 Galerkin의 방법을 기술하였다. 일단 지지보는 자유단 끝점 또는 모드의 노드 포인트에 부가 질량과 스프링에 의하여 구속되어 있다. 수치해석으로 구한 고유진동수는 간단한 해석 방법과 간단한 테스트에 의하여 각각 구한 결과와 비교 되었다. Galerkin의 방법을 사용하여 논의된 일단 지지보의 고유 진동수를 구할 수 있음을 보였다. 부가 질량 증가함에 따라 고유 주파수는 감소하며 스프링 힘의 증가에 따라 고유 주파수는 상승함을 보였다. 무거운 부가 질량은 가연성 배관의 지지대 역할을 함을 보였다. 일단 지지보의 끝단에 설치된 부가 질량의 경우에 개발된 기존의 어림적 해석 방법으로도 일차 모두의 고유 진동수를 비교적 정확하게 구할 수 있음을 알 수 있었다.

WCDMA 시스템에서 단말 측정에 의한 압축 모드 방법 (UE Measurement Based Compressed Mode in WCDMA)

  • 김선명;장원학;조영종;임재성
    • 한국통신학회논문지
    • /
    • 제29권7A호
    • /
    • pp.814-827
    • /
    • 2004
  • WCDMA 시스템에서는 다른 주파수 또는 다른 시스템의 신호 세기를 측정하기 위하여 압축 모드(Compressed Mode)를 사용한다. 압축 모드로 동작하는 동안에는 처리 이득(Processing Gain)이 낮아지기 때문에 단말의 QoS(Quality of Service)에 영향을 끼친다. 그러므로 기지국은 단말이 요구하는 QoS를 만족시키기 위해서 전송 전력량을 증가시킨다. 한편 압축 모드의 전송 간격(Transmission Gap) 동안에는 내부 회로 전력 제어가 동작하지 않고 인터리빙(Interleaving)의 영향도 줄어들기 때문에 단말은 더 높은 Eb/No을 요구하게 된다. 따라서 시스템의 전체적인 성능 저하를 초래하게 된다. 성능에 미치는 영향 때문에, 압축 모드는 RNC(Radio Network Controller)에 의해서 다른 주파수 또는 다른 시스템의 신호 측정이 필요한 경우에만 동작하여야 한다. 그러나 3GPP는 압축 모드 동작을 결정할 수 있는 방법을 정의하지 않았다. 그러므로 성능 저하를 줄이기 위해서 압축 모드 동작을 결정할 수 있는 방법이 필요하다. 본 논문에서는 서비스 셀과 같은 주파수를 사용하는 인접 셀과 다른 주파수 또는 다른 시스템을 사용하는 인접 셀로 구성된 셀 환경에서 압축 모드가WCDMA 순방향 링크의 성능에 미치는 영향을 수식적으로 분석하고 압축 모드 사용에 따른 성능 저하를 줄이기 위하여 압축 모드가 필요하지 않은 단말의 압축모드 동작을 제한할 수 있는 단말 측정에 의한 압축 모드 방법을 제안한다. 수치적 분석 결과, 압축 모드를 사용할 때의 성능은 압축 모드를 사용하지 않을 때의 성능에 비해 급격하게 감소하는 것을 확인하였다. 그리고 제안하는 방법을 적용하였을 때, 압축 모드 사용에 따른 성능 감소를 크게 줄임을 확인하였다.

불균일 단면을 갖는 단순지지 보의 모달해석 및 실험 (Modal Analysis and Experiment of a Simply-supported Beam with Non-uniform Cross Sections)

  • 김인우;유봉조;김영식
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8654-8664
    • /
    • 2015
  • 기계, 건축, 토목공학 분야 등에는 불균일 단면을 갖는 보 형태의 구조물들이 널리 사용되고 있다. 본 논문은 양단이 단순 지지된 보 구조물들의 동특성과 진동에 대한 문제를 다루며, 국부좌표를 사용한 지배방정식이 유도된다. 갤러킨의 모드합 방법으로 해가 가정되고, 고유진동수를 구하는 행렬식을 푸는 데는 이분법을 적용하였다. 유한요소법이 단지 기하학적 경계조건만을 만족시키는 허용함수를 사용하는 반면, 본 논문에서는 갤러킨의 모드합 방법을 적용하여, 지배방정식과 경계조건을 모두 만족하는 고유함수를 사용하였다. 계의 동특성을 알기위해, 네 종류의 불균일 단면을 갖는 단순 지지 보에 대해 모달 해석과 시험이 수행되었으며, 해석 결과는 실험 결과와 근사한 일치를 나타내었다.

전자부품 고장모드를 고려한 Built-In-Test 성능분석 (Built-In-Test Coverage Analysis Considering Failure Mode of Electronics Components)

  • 서준호;고진영;박한준
    • 한국항공우주학회지
    • /
    • 제43권5호
    • /
    • pp.449-455
    • /
    • 2015
  • Built-In-Test(이하: BIT)는 항공기 비행안전을 위해 반드시 필요한 기능으로 항공전자 장비의 경우 95% 이상의 높은 고장 진단능력을 요구하고 있다. BIT가 요구도에 명시된 고장 진단능력을 만족시키는지 확인하기 위해 BIT 성능분석이 필요하다. BIT 성능분석을 위해 FMECA (Failure Mode Effect Critical Analysis)에 기술된 고장모드를 활용하는 방법이 많이 사용되고 있으나, 본 논문에서는 분석 오류를 최소화할 수 있는 전자부품 기반의 BIT 성능분석 방법론을 소개한다. 또한, BIT 성능분석에서 제외될 수 있는 비행안전에 영향을 미치지 않는 전자부품 및 전자부품의 고장모드를 실제 개발사례에 적용하여 불필요한 BIT 기능 구현을 방지하고 정확한 BIT 성능분석을 수행할 수 있도록 하였다. BIT Demo를 수행하여 BIT 성능분석 결과와 실제 BIT 성능이 일치함을 확인하였다.

지반-구조물 연계모델의 등가감쇠값에 관한 연구 (A Study on Equivalent Modal Damping Values of Soil-Structure Coupling Models)

  • 박형기
    • 대한토목학회논문집
    • /
    • 제7권3호
    • /
    • pp.241-248
    • /
    • 1987
  • 지반-구조물 상호작용 효과가 큰 경우의 동적문제를 모드중첩법으로 해결하기 위하여 여러 가지 등가모드감쇠값 결정 방법에 대한 이론적 배경을 검토하였다. 또한 component mode synthesis method에 의하여 감쇠행렬을 구하고 이를 이용한 직접적분법으로 지반-구조물의 연계모델의 응답을 계산하여 각 등가모드감쇠값 결정 방법으로 구한 등가모드감쇠값을 사용한 모드 중첩법의 해석 결과와 비교 분석하였다. 해석모델로는 2종류의 상부구조와 4종류의 지반조건을 고려하고 이를 조합한 경우를 채택하였다. 본 연구 결과로 소멸에너지법으로 얻은 등가모드감쇠값이 직접적 분법의 결과에 가장 근사적인 결과를 주는 것을 알 수 있었다. 고정지반모델인 경우에는 강도가중법을 제외한 다른 방법으로 구한 등가모드감쇠값은 직접적분법의 결과와 거의 일치되는 응답을 주었다.

  • PDF