• 제목/요약/키워드: Analytical measurement range

검색결과 140건 처리시간 0.029초

Advancing behavioral understanding and damage evaluation of concrete members using high-resolution digital image correlation data

  • Sokoli, Drit;Shekarchi, William;Buenrostro, Eliud;Ghannoum, Wassim M.
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.609-626
    • /
    • 2014
  • The capabilities of a high-resolution Digital Image Correlation (DIC) system are presented within the context of deformation measurements of full-scale concrete columns tested under reversed cyclic loading. The system was developed to have very high-resolution such that material strains on the order of the cracking stain of concrete could be measured on the surface of full-scale structural members. The high-resolution DIC system allows the measurement of a wide range of deformations and strains that could only be inferred or assumed previously. The DIC system is able to resolve the full profiles of member curvatures, rotations, plasticity spread, shear deformations, and bar-slip induced rotations. The system allows for automatic and objective measurement of crack widths and other damage indices that are indicative of cumulated damage and required repair time and cost. DIC damage measures contrast prevailing proxy damage indices based on member force-deformation data and subjective damage measures obtained using visual inspection. Data derived from high-resolution DIC systems is shown to be of great use in advancing the state of behavioral knowledge, calibrating behavioral and analytical models, and improving simulation accuracy.

Validation, Measurement Uncertainty, and Determination of Bixin and Norbixin in Processed Foods of Animal Resources Distributed in Korea

  • Ga-Yeong Lee;Choong-In Yun;Juhee Cho;Young-Jun Kim
    • 한국축산식품학회지
    • /
    • 제43권6호
    • /
    • pp.949-960
    • /
    • 2023
  • This research aimed to validate a high-performance liquid chromatography method for the quantitative determination of bixin and norbixin in various foods. The Diode Array Detector (495 nm) technique was used. Method was validated for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. The calibration curve showed excellent linearity (r2≥0.9999) over the tested concentration range of 0.2-25 mg/L. The LOD and LOQ were 0.03-0.11 and 0.02-0.05 mg/L for bixin and norbixin, respectively. The intra-and inter-day accuracies and precisions were 88.0±1.3-97.0±0.5% and 0.2%-2.6% relative SD (RSD) for bixin and 88.2±0.8-105.8±0.8% and 0.3%-2.7% RSD for norbixin, respectively. Inter-laboratory validation for accuracy and precision was conducted in three laboratories, and these results all met the AOAC guidelines. In addition, the relative expanded uncertainty (<22%) satisfied the CODEX recommendation. Furthermore, products distributed in Korea were monitored for annatto extracts using the proposed method to demonstrate its application. The developed analytical method is reliable for quantifying bixin and norbixin in various foods.

토양내 중금속 실시간 탐지를 위한 레이저 유도붕괴 분광법의 활용에 대한 소개 (Application of Laser-Induced Breakdown Spectroscopy (LIBS) for In-situ Detection of Heavy Metals in Soil)

  • 고은정;함세영;김경웅
    • 자원환경지질
    • /
    • 제40권5호
    • /
    • pp.563-574
    • /
    • 2007
  • LIBS는 시료 표면에서 발생된 플라즈마로부터 방출되는 원자들의 분광선을 측정함으로써 물질의 화학적 조성을 감지, 확인, 정량화할 수 있는 최신의 분석기술로 기존의 전형적인 원소분석방법에 비해 현장분석기술로서의 더 많은 장점을 가지고 있다. LIBS는 최소한의 시료로 복잡한 분석과정을 피함으로 신속한 분석을 가능케 하고, 기기의 다방면적의 적용가능성과 단순함으로 인해 신속하게 가스, 고체, 액체상에서 다원소를 동시에 분석할 수 있는 레이저 기반의 분석기술로 지구화학적 분석, 탐사 혹은 환경분석에서 현장 이동성을 가진 센서로의 가능성 측면에서 매력적인 도구가 된다. 그러나 현장분석기술로서 토양환경에 적용하기에는 여전히 해결해야 할 문제들이 있다. 문헌연구를 통해 기본적인 작용원리인 플라즈마 형성과 물질붕괴과정을 고찰하고 현장분석기술로서 LIBS의 현 위치를 살펴본다. 또한 토양환경에 적용하기 위해 매질의 특성, 레이저 특성 및 분석신호에 영향을 미치는 다양한 인자들을 살펴보아 LIBS에 대한 기본적 이해를 돕고자 한다. 또한 분석에 미치는 영향 인자들을 보정해 분석 결과의 정확도, 정밀도 및 검출 한계 등 분석의 질을 향상 시킬 수 있는 기법 등을 다양한 문헌 연구를 통해 살펴봄으로써 추후 국내 토양환경분야의 LIBS 현장기술의 적용가능성을 고찰해보고자 한다.

Measurement of Aldehydes in Replacement Liquids of Electronic Cigarettes by Headspace Gas Chromatography-mass Spectrometry

  • Lim, Hyun-Hee;Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2691-2696
    • /
    • 2013
  • The electronic cigarette (E-cigarette) is a battery-powered device that aerosolizes nicotine so that it is readily delivered into the respiratory tract. The analytical data regarding the substances present in E-cigarettes are very limited. The aim of this study was to measure the concentration of aldehydes-formaldehyde (FA), acetaldehyde (AA) and, acrolein (AL)-in 225 replacement liquid brands from 17 E-cigarette shops sold in the Republic of Korea by headspace solid-phase micro extraction and gas chromatography-mass spectrometry (HS-SPME GC-MS). The concentration range of FA and AA was 0.02-10.09 mg/L (mean = 2.16 mg/L, detected in 207 of 225 samples) and 0.10-15.63 mg/L (mean = 4.98 mg/L, detected in all samples), respectively. AL was not detected in any of 225 replacement liquids. FA and AA were originally present in almost all replacement liquids of electronic cigarettes.

Application of Compressive Sensing to Two-Dimensional Radar Imaging Using a Frequency-Scanned Microstrip Leaky Wave Antenna

  • Yang, Shang-Te;Ling, Hao
    • Journal of electromagnetic engineering and science
    • /
    • 제17권3호
    • /
    • pp.113-119
    • /
    • 2017
  • The application of compressive sensing (CS) to a radar imaging system based on a frequency-scanned microstrip leaky wave antenna is investigated. First, an analytical model of the system matrix is formulated as the basis for the inversion algorithm. Then, $L_1-norm$ minimization is applied to the inverse problem to generate a range-azimuth image of the scene. Because of the antenna length, the near-field effect is considered in the CS formulation to properly image close-in targets. The resolving capability of the combined frequency-scanned antenna and CS processing is examined and compared to results based on the short-time Fourier transform and the pseudo-inverse. Both simulation and measurement data are tested to show the system performance in terms of image resolution.

Performance and Robustness of Control Charting Methods for Autocorrelated Data

  • Chin, Chang-Ho;Apley, Daniel W.
    • 대한산업공학회지
    • /
    • 제34권2호
    • /
    • pp.122-139
    • /
    • 2008
  • With the proliferation of in-process measurement technology, autocorrelated data are increasingly common in industrial SPC applications. A number of high performance control charting techniques that take into account the specific characteristics of the autocorrelation through time series modeling have been proposed over the past decade. We present a survey of such methods and analyze and compare their performances for a range of typical autocorrelated process models. One practical concern with these methods is that their performances are often strongly affected by errors in the time series models used to represent the autocorrelation. We also provide some analytical results comparing the robustness of the various methods with respect to time series modeling errors.

Toxicological Investigation of Radioactive Uranium in Seawater

  • Ly, Suw-Young;Bae, Jeong-Mi;Kim, Jin
    • Toxicological Research
    • /
    • 제28권1호
    • /
    • pp.67-71
    • /
    • 2012
  • Trace uranium detection measurement was performed using DNA immobilized on a graphite pencil electrode(DGE). The developed probe was connected to the portable handheld voltammetric systems used for seawater analysis. The sensitive voltammogram was obtained within only 30 s accumulation time, and the anodic stripping working range was attained at 100~800 ${\mu}g/l$ U and 10~50 ${\mu}g/l$. The statistic relative standard deviation of 30.0 mg/l with the $15^{th}$ stripping was 0.2115. Here, toxicological and analytical application was performed in the seawater survey in a contaminated power plant controlling water. The results were found to be applicable for real-time toxicological assay for trace control.

In-situ 소음투과손실 측정 및 검증을 위한 기법 개발 (New Method for Measurement and Validation of In-situ Sound Transmission Loss)

  • 이화수;박홍철;윤성호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.795-800
    • /
    • 2008
  • The sound transmission loss is a key index to evaluate the acoustic performance of a car-body structure at the high frequency range. From this paper, a new validation method for in-situ sound transmission loss is proposed. First, in-situ sound transmission loss is measured by using PU intensity probe on the condition of complete vehicle. Second, validation test, which is consisted of internal, external and total frequency response function test, is performed by using volume acceleration source and microphones. Then, these test results are compared to validate the accuracy of in-situ sound transmission loss. Finally, the test result of in-site method is compared with results of two reverberant room test method and SEA analytical method. The reliability of in-situ method is confirmed by these procedures.

  • PDF

Electrochemical Behavior of Norfloxacin and Its Determination at Poly(methyl red) Film Coated Glassy Carbon Electrode

  • Huang, Ke-Jing;Xu, Chun-Xuan;Xie, Wan-Zhen
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.988-992
    • /
    • 2008
  • A poly(methyl red) film-modified glassy carbon electrode (PMRE) was fabricated for determination of norfloxacin (NFX). The electrochemical behavior of NFX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. PMRE greatly enhanced the oxidation peak current of NFX owing to the extraordinary properties of poly(methyl red) film. Based on this, a sensitive and simple voltammetric method was developed for measurement of NFX. A sensitive linear voltammetric response for NFX was obtained in the concentration range of $1\;{\times}\;10^{-6}\;-\;1\;{\times}\;10^{-4}$ mol/L and the detection limit was $1\;{\times}\;10^{-7}$ mol/L using linear sweep voltammetry (LSV). The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity. The practical application of this new analytical method was demonstrated with NFX pharmaceuticals.

고 다공성 물질에서 열 및 물질전달 (Heat and Mass Transfer in Highly Porous Media)

  • 이금배
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.685-693
    • /
    • 1990
  • 본 연구에서는 복사열전달 효과를 알아보기 위해 에너지 방정식을 수치적으로 풀었으며, 그 결과를 열전달계수 및 온도의 항으로 나타내었다. 수치 해석적 모델의 검증을 위해 여러사람들이 물질전달과정 해석을 위해 사용한 나프타린 승화법(naphth- alene sublimation technique)을 이용하여 실험을 수행하였다. 또한 실험에 사용된 다공질체(ceramic blocks)의 침투율도 측정하였다.