• 제목/요약/키워드: Analytical measurement range

검색결과 140건 처리시간 0.025초

Comparison of different colorimetric assays and application of the optimized method for determining the liberated fluoride contents in various tea extracts

  • Le-Thi Anh-Dao;Do Minh-Huy;Nguyen-Ho Thien-Trang;Nguyen Cong-Hau
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.87-97
    • /
    • 2024
  • The appropriate intake of fluoride (F-) is beneficial to human health; however, the over-consumption can result in various potentially harmful effects. This study compared different colorimetric reagents, i.e., aluminium-xylenol orange (Al-XO), zirconium-xylenol orange (Zr-XO), and zirconium-alizarin red S (Zr-ARS), for fluoride measurements by the UV-Vis, in terms of reaction mechanisms, method sensitivity, and interferences from aluminium and ferric ions. The colorimetric procedures were optimized, and the analytical methods were evaluated. The goodness of linearity (R2 > 0.998) was obtained for all three assays within the concentration range of 1.0-20.0 mg/L fluoride in deionized water, in which the method sensitivity followed the descending order of Zr-XO > Al-XO > Zr-ARS. The Zr-XO was applied for determining the fluoride in different tea extracts in water (90 ℃ and 60-minute-brewing) and black tea demonstrated the highest fluoride content (3.0-3.6 mg/L). The effects of brewing time and temperature on the release of fluoride in the tea extracts were also investigated, indicating these are critical factors for the fluoride extraction. This study highlighted the application potentials of the UV-Vis measurement as a simple, convenient, and cheap analytical approach and discussed different colorimetric reagents used for fluoride determination in tea extracts in the context that the UV-Vis spectrophotometers are commonly equipped in most laboratories.

Dynamic SPME를 이용한 공기 중 지방산 분석 (Analysis of Volatile Fatty Acids in Air by Dynamic SPME)

  • 유미선;양성봉;하남기
    • 한국환경과학회지
    • /
    • 제19권12호
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

중성운반체를 이용한 리튬이온 선택 전극 (Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier)

  • 김재상
    • 분석과학
    • /
    • 제5권1호
    • /
    • pp.33-39
    • /
    • 1992
  • 리튬이온의 새로운 중성운반체로서 tetrahydrofuran 단위의 16고리형 crown-4를 퓨란과 아세톤으로부터 산 촉매하에서 합성하여 수소화시킨 후 리튬-이온과의 착물형성반응을 Li-7 NMR과 전기전도도법으로 조사했다. 합성한 리간드를 PVC-액체막 전극에 사용하여 분리용액법에 의한 리튬이온의 선택성을 결정하였다. 막용매, tris(2-ethylhexyl) phosphate에서 리튬이온의 선택계수는 알칼리금속이온 및 알칼리토금속이온에 대해 $2.4{\times}10^{-1}$에서 $2.3{\times}10^{-4}$ 범위의 값을 가졌으며, 산성용액(pH=2 이하, 0.1M LiCl)에서 액체막은 $H^+$ 이온의 방해로 불안정하였다.

  • PDF

Method development and validation for dieckol in the standardization of phlorotannin preparations

  • Kim, Jiyoung;Um, Minyoung;Yang, Hyejin;Kim, Inho;Lee, Changho;Kim, Yuntai;Yoon, Minseok;Kim, Youngkyoung;Kim, Jimi;Cho, Suengmok
    • Fisheries and Aquatic Sciences
    • /
    • 제19권1호
    • /
    • pp.3.1-3.6
    • /
    • 2016
  • Phlorotannins are reported to have diverse biological properties. However, no analytical methods for the standardization of phlorotannin preparations have been reported. Herein, we developed and validated an analytical method for the determination of dieckol in phlorotannin extracts (PRT) using high-performance liquid chromatography (HPLC). The optimum HPLC conditions consisted of a Supelco Discovery C18 column stationary phase, a mobile phase (A: 15 % HPLC grade methanol in deionized water, B: methanol), UV detection at 230 nm, and a flow rate of 0.7 mL/min. The optimized chromatographic conditions were validated and exhibited good specificity and linearity ($R^2$ > 0.9994-1.0000). The recoveries were in the range of 100.9-102.3 %. The method had good intermediate (%RSD 1.2) and intra-day (%RSD 0.4-1.7) assay precisions. This HPLC method had good accuracy and quality in the determination of dieckol in PRT.

An Application of the Analytical Hierarchy Process (AHP) for Safety measurement in Malaysian Construction Industry

  • Samad Doostdar;Zubaidah Ismail
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.66-73
    • /
    • 2013
  • Analytical Hierarchy Process (AHP) is a famous method amongst Multi Criteria Decision Making (MCDM), set up by Saaty in 1980. AHP can be determined as a methodology of hierarchical analysis following reasonable decision making with make simpler a difficult crisis. Decision making in systems of Safety management concerned multipart challenges. AHP is process for get better the composite decisions understanding with analyzes of the problem in a structure of hierarchy. The integration all of applicable decision criteria, their pair wise judgment permits the decision maker to establish the trade-offs amongst objectives. In recent years, Malaysian's economy and infrastructure development have significantly and rapidly risen. The construction industry continues to play a major role in this development as many construction activities have been carried out to meet the high demands of the expansive market. However, the construction industry has faced a wide range of challenges, one of which is the frequent occurrences of accidents at the workplace. An effective safety program can substantially reduce accidents because it can help management to build up safer means of operations and create safe working environments for the workers. Furthermore, by having an effective safety programs, good safety culture can be embedded in organization because it can encourage mutual cooperation between management and workers in the operations of the programs and decisions that affect their safety and health. The focus of this research is development methodology of Analytics Hierarchy Process (AHP) in construction safety factors and investigates the levels of some effective elements in SMS in Malaysian construction industries.

  • PDF

An enhanced analytical calculation model based on sectional calculation using a 3D contour map of aerodynamic damping for vortex induced vibrations of wind turbine towers

  • Dimitrios Livanos;Ika Kurniawati;Marc Seidel;Joris Daamen;Frits Wenneker;Francesca Lupi;Rudiger Hoffer
    • Wind and Structures
    • /
    • 제38권6호
    • /
    • pp.445-459
    • /
    • 2024
  • To model the aeroelasticity in vortex-induced vibrations (VIV) of slender tubular towers, this paper presents an approach where the aerodynamic damping distribution along the height of the structure is calculated not only as a function of the normalized lateral oscillation but also considering the local incoming wind velocity ratio to the critical velocity (velocity ratio). The three-dimensionality of aerodynamic damping depending on the tower's displacement and the velocity ratio has been observed in recent studies. A contour map model of aerodynamic damping is generated based on the forced vibration tests. A sectional calculation procedure based on the spectral method is developed by defining the aerodynamic damping locally at each increment of height. The proposed contour map model of aerodynamic damping and the sectional calculation procedure are validated with full-scale measurement data sets of a rotorless wind turbine tower, where good agreement between the prediction and measured values is obtained. The prediction of cross-wind response of the wind turbine tower is performed over a range of wind speeds which allows the estimation of resulting fatigue damage. The proposed model gives more realistic prediction in comparison to the approach included in current standards.

Voltammetric Determination of Copper(II) at Chemically Modified Carbon Paste Electrodes Containing Alga

  • Bae, Zun-Ung;Kim, Young-Lark;Chang, Hye-Young
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.611-615
    • /
    • 1995
  • The design of appropriate chemically modified electrodes should allow development of new voltammetric measurement schemes with enhanced selectivity and sensitivity. Microorganism like algae has high ability to trap toxic and heavy metal ions and different affinities for metal ions. A copper(II) ion-selective carbon paste electrode was constructed by incorporating alga Anabaena into a conventional carbon paste mixture, and then the film of 10% Nafion was coated to avoid the swelling of the electrode surface. Copper ion could be deposited at the 25% algamodified electrode for 15 min without the applied potential while stirring the solution by only immersing the electrode in a buffer (pH 4.0) cot1taining copper(II). Temperature was controlled at $35^{\circ}C$. After preconcentration was carried out the electrode was transferred to a 0.1 M potassium chloride solution and was reduced at -0.6 volt at $25^{\circ}C$. The differential pulse anodic stripping voltammetry was employed. A well-defined oxidation peak could be obtained at -0.1 volt (vs SCE). In five deposition / measurement / regeneration cycles, the responses were reproducible and relative standard deviations were 3.3% for $8.0{\times}10^{-4}M$ copper(II). Calibration curve for copper was linear over the range from $2.0{\times}10^{-4}M$ to $1.0{\times}10^{-3}M$. The detection limit was $7.5{\times}10^{-5}M$. Studies of the effect of diverse ions showed that the coexisting metal ions had little or no effect for the determination of copper. But anions such as cyanide. oxalate and EDTA seriously interfered.

  • PDF

PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구 (Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs)

  • 홍좌령;최광민
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

Multi-Scaling Models of TCP/IP and Sub-Frame VBR Video Traffic

  • Erramilli, Ashok;Narayan, Onuttom;Neidhardt, Arnold;Saniee, Iraj
    • Journal of Communications and Networks
    • /
    • 제3권4호
    • /
    • pp.383-395
    • /
    • 2001
  • Recent measurement and simulation studies have revealed that wide area network traffic displays complex statistical characteristics-possibly multifractal scaling-on fine timescales, in addition to the well-known properly of self-similar scaling on coarser timescales. In this paper we investigate the performance and network engineering significance of these fine timescale features using measured TCP anti MPEG2 video traces, queueing simulations and analytical arguments. We demonstrate that the fine timescale features can affect performance substantially at low and intermediate utilizations, while the longer timescale self-similarity is important at intermediate and high utilizations. We relate the fine timescale structure in the measured TCP traces to flow controls, and show that UDP traffic-which is not flow controlled-lacks such fine timescale structure. Likewise we relate the fine timescale structure in video MPEG2 traces to sub-frame encoding. We show that it is possibly to construct a relatively parsimonious multi-fractal cascade model of fine timescale features that matches the queueing performance of both the TCP and video traces. We outline an analytical method ta estimate performance for traffic that is self-similar on coarse timescales and multi-fractal on fine timescales, and show that the engineering problem of setting safe operating points for planning or admission controls can be significantly influenced by fine timescale fluctuations in network traffic. The work reported here can be used to model the relevant characteristics of wide area traffic across a full range of engineering timescales, and can be the basis of more accurate network performance analysis and engineering.

  • PDF

Clinical Utility and Cross-Reactivity of Insulin and C-Peptide Assays by the Lumipulse G1200 System

  • Oh, Jongwon;Kim, Jae Hyeon;Park, Hyung-Doo
    • Annals of Laboratory Medicine
    • /
    • 제38권6호
    • /
    • pp.530-537
    • /
    • 2018
  • Background: Measurement of insulin and C-peptide concentrations is important for deciding whether insulin treatment is required in diabetic patients. We aimed to investigate the analytical performance of insulin and C-peptide assays using the Lumipulse G1200 system (Fujirebio Inc., Tokyo, Japan). Methods: We examined the precision, linearity, and cross-reactivity of insulin and C-peptide using five insulin analogues and purified proinsulin. A method comparison was conducted between the Lumipulse G1200 and Roche E170 (Roche Diagnostics, Mannheim, Germany) systems in 200 diabetic patients on insulin treatment. Reference intervals for insulin and C-peptide concentrations were determined in 279 healthy individuals. Results: For insulin and C-peptide assays, within-laboratory precision (% CV) was 3.78-4.14 and 2.89-3.35%, respectively. The linearity of the insulin assay in the range of 0-2,778 pmol/L was $R^2=0.9997$, and that of the C-peptide assay in the range of 0-10 nmol/L was $R^2=0.9996$. The correlation coefficient (r) between the Roche E170 and Lumipulse G1200 results was 0.943 (P <0.001) for insulin and 0.996 (P <0.001) for C-peptide. The mean differences in insulin and C-peptide between Lumipulse G1200 and the Roche E170 were 19.4 pmol/L and 0.2 nmol/L, respectively. None of the insulin analogues or proinsulin showed significant cross-reactivity with the Lumipulse G1200. Reference intervals of insulin and C-peptide were 7.64-70.14 pmol/L and 0.17-0.85 nmol/L, respectively. Conclusions: Insulin and C-peptide tests on the Lumipulse G1200 show adequate analytical performance and are expected to be acceptable for use in clinical areas.