• Title/Summary/Keyword: Analytical instruments

Search Result 111, Processing Time 0.027 seconds

Use of Near Infrared Spectroscopy in the Meat Industry

  • Akselsen, Thorvald M.
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2000.11a
    • /
    • pp.1-14
    • /
    • 2000
  • The Near Infrared region of the energy spectrum was first discovered by Hershel in the year 1800. The principles of NIR is based on light absorption of specific organic chemical bonds. The absorption at each wavelength is measured and a spectre is obtained. The spectre is then treated mathematically and with the absorption data is converted to absolute units via a calibration. In the last two decades it has developed dramatically. With the invention of computers and the ability to treat a large amount of data in a very short time the use of NIR for many different purposes has developed very fast. During the last decade with the aid of very powerful PC's the application of NIR technology has become even more widespread. Now or days development of very robust calibrations can be done in a relatively short time with a minimum of resources. The use of Near Infrared Spectroscopy (NIR) in the Meat industry is relatively new. The first installations were taken into operation in the 80ties. The Meat Industry in often referred to as rather conservative and slow to embrace new technologies, they stay with the old and proven methods. The first NIR instruments used by the Meat Industry, and most other industries, were multipurpose build, which means that the sample presentation was not well suited to this particular application, or many other applications for that sake. As the Meat Industry grows and develops to meet the demands of the modern markets, they realise the need for better control of processes and final products. From the early 90 ties and onward the demand for 'rear time' rapid results starts growing, and some suppliers of NIR instruments (and instruments based on other technologies, like X-ray) start to develop and manufacture instrumentation dedicated to the particular needs of the Meat Industry. Today it is estimated that there are approximately 2000 rapid instruments placed in the Meat industry world-wide. By far most of these are used as at-line or laboratory installations, but the trend and need is moving towards real on-line or in-line solutions. NIR is the most cost effective and reproducible analytical procedure available for the twenty first century.

  • PDF

Basics of Ion Mobility Mass Spectrometry

  • Lee, Jong Wha
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.79-89
    • /
    • 2017
  • Ion mobility mass spectrometry (IM-MS) combines the advantages of ion mobility spectrometry (IMS) and MS for effective gas-phase ion analysis. Separation of ions based on their mobilities prior to MS can be performed without a great loss in other analytical figures of merit, and the extra dimension of analysis offered by IM can be beneficial for isomer and complex sample analyses. In this review, basic principles of IMS and IM-MS are described in addition to an introduction to various IMS techniques and commercial IM-MS instruments. The nature of collision cross-section (${\Omega}_D$), an important parameter determining the transport properties of ions in IMS, is also explained in detail.

Trends in System-level Research on Quality Control of Complex Herbal Formulation (복합 처방 품질 관리를 위한 시스템 차원의 연구 동향)

  • Lee, Doo Suk;Kim, Young Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.6
    • /
    • pp.397-401
    • /
    • 2016
  • The quality control is a fundamental procedure for the standardization of herbal medicine to guarantee the consistency of efficacy and safety. For a long time, the quality analysis of herbal medicine has been largely dependent on the routine sensory evaluation, such as taste, smell, color, and shape. However, with the recent development of analytical instruments, various scientific approaches have been introduced in this field. On the basis of the theory that the biological activities of herbal medicine are mainly contributed by its chemical compositions, several types of chemical markers have been suggested for the quality evaluation. In addition to the analytical methods for the specific marker compound(s), including analytical marker and active marker, recently, chemical fingerprinting, a method comparing the chromatographic pattern of the whole chemical components, has been developed and widely accepted as a reliable approach for the quality control of herbal medicine. Moreover, in order to exactly understand the relationship between complex compounds and their holistic biological activities in herbal medicine, unique strategies, such as "BECCs (bioactive equivalent combinatorial components)" and "PhytomicsQC" have been established. In this article, we give an overview of the several categories of chemical markers and the recent research trends for the quality evaluation of herbal medicine.

Development of Controlling and Analyzing Software for Portable Atomic Emission Spectrometry (휴대용 원자 방출 분광계를 위한 제어 및 분석용 소프트웨어 개발)

  • Lee, Sang Chun;Lee, Chang-Soo;Jung, Min-Soo;Ryu, Dong-Hang
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • This study focuses on developing a controlling and analyzing software for the portable atomic emission spectrometer equipped with an electrothermal vaporizer(ETV) that can perform the in-situ trace analysis of heavy metal ions dissolved in water. The software works well for a notebook PC and it is exclusively developed for the real time analysis with a line filter and a photomultiplier light detector. The program is designed to operate under Windows 95 environment and either Korean or English can be used as a main language. The Delphi 2.0 language software is mainly used for programing. The program is designed to make a calibration curve and the system users can get the analytical data in a short time. And a final report can be generated without having difficulties. This software can be easily modified for other analytical atomic spectrometers.

  • PDF

Proposal of Localization Policy Based on the Status of Chinese's Research Facilities and Equipment Construction in Korean Basic and Analytical Science Field (국내 기초·분석과학 분야 내 중국산 연구시설·장비 구축 현황에 따른 국산화 정책 제언)

  • Kim, Chang-Yong;Chung, Taewon;Kong, Jaehyun;Park, Chan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.460-471
    • /
    • 2019
  • The aim of this study was to examine the scale and market share of Chinese's research facility & equipment in the domestic research equipment market of basic and analytical science field for analyzing the difference of the number and amount of construction by year of acquisition, national research facility equipment standard classification code, and type of institution based on the information of the research equipment invested by the Korean government for the past 14 years. In addition, we analyzed the correlation among the year of acquisition, equipment standard classification code, and type of institution variables. As of January 1 2019, from 2005 to 2018, 50 Chinese's research facilities & equipments (main equipment with a construction cost of 30 million won or more) built in the basic and analytical science fields were selected for this study and their number of construction, amount of construction, year of acquisition, type of institution, and standard classification code were analyzed. Differences of the number and amount of construction with-in and by year of acquisition, standard classification code, and type of institution were tested using a single sample Chi-square test, Mann-Whitney U test, and Kruskal-wallis test. The correlation among the three variables was analyzed by using the Chi-square test of cross-tabulation analysis. And there was a statistically significant correlation among the year of acquisition, standard classification code, and type of institution (p<.05). Compared to the 2000s, in the 2010s, high-priced Optical Electronics/Video Equipment was installed at private universities, private enterprises, and government-affiliated research institute. Therefore, the domestic construction status of Chinese's research facility & equipment in the basic science and analytical science field is less than that of the domestic ones, but the number and the amount of construction are increasing statistically. So it is necessary for the government to be able to recognize the possibility that the Chinese's research facility and equipment can encroach on the domestic research industry market and to prepare related provision.

Method for the Analysis of Polybrominated Biphenyls(PBBs) in Environmental Samples (환경시료 중 폴리브롬화비페닐(Polybrominated Biphenyls) 분석법)

  • Shin, S.K.;Kim, T.S.;Hwang, S.Y.;Lee, W.S.;Chung, Y.H.;Na, J.G.
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.300-316
    • /
    • 2002
  • The extraction methods of PBBs from environmental samples by soxhlet extraction for solid phase and liquid-liquid extraction for liquid phase were compared. After extraction, silicagel and florisil as column clean up methods were used for the comparison of cleanup efficiency with different solvent system. Also, the analytical instruments were used GC/MSD. The 22 kinds of PBBs standards were used to establish the analytical methods to perform the experiments of recoveries and detection limits in water and soil. The detection limits of PBBs represented 5~10 ng/L for water and 0.5~3.5 ng/g for soil samples, respectively. The recoveries of water samples represented 96~107% in n-hexane, dichloromethane and toluene for water, and 60~80% in combined solvent with n-hexane and acetone. The recoveries of soil sample were surveyed 67~97% in soxhlet extraction and 64~76% in ultrasonic extraction with selected solvents.

A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents (대체 세정제의 선정을 위한 세정성 평가방법 연구)

  • Shin, Jin-Ho;Lee, Jae-Hoon;Bae, Jae-Heum;Lee, Min-Jae;Hwang, In-Gook
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • In this study various cleaning evaluation methods were tested and comparatively evaluated to help cleaning industry. In order to select alternative cleaning agents objectively and systematically, various cleaning evaluation methods such as gravimetric, optically simulated electron emission (OSEE), contact angle, and analytical instrument methods were employed for cleaning contaminants such as flux, solder and grease. The analytical instruments used in this work were Fourier transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV-VIS) and high performance liquid chromatography (HPLC). The gravimetric method was able to measure cleaning efficiencies easily and simply, but it was not easy to analyze them precisely because of its limitation in the gravimetric measurement. However, the OSEE technique was able to measure quickly and precisely the clean ability of cleaning agents in comparison with the gravimetric method. The contact angle method was found to be necessary for taking special precaution in its application to the cleaning evaluation due to possible formation of tiny organic film on the substrate surface which might be generated from contaminants and cleaning agents. In case of precision analysis that cannot be done by gravimetric method, fine analytical instruments such as UV-VIS, FTIR and HPLC could be used in analyzing trace amount of flux, solder and grease quantitatively, which were extracted from the surface by special solvents.

Assessment of the Seismic Capacity of Structure Using Pseudodynamic Test (유사동적 실험법을 이용한 구조물의 내진 성능 평가)

  • 김대곤;김대영;안재현;박칠림
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.49-57
    • /
    • 1997
  • It is necessary to conduct researches about seismic design and analysis to protect various structures from earthquakes which are one of the most destructive natural disaster to human civilization. To assess the seismic capacity of structure, not only analytical but also experimental researches are important. Currently, pseudodynamic test known as computer-actuator on-line test is one of the available test methods to assess seismic capacity of structure without using shaking table. In this paper seismic capacity of simple one-degree of freedom structure was estimated by pseudodynamic test. Good agreement between the experimental and analytical results was obtained. Better results would be obtained when more sophisticated measuring and controlling instruments are available.

  • PDF

Prioritizing Service Supply-Chain Performance Measures Using Multi-Criteria Decision-Making Methodologies

  • ABBAS, Haidar;ALAWI, Alamir Al;MAKTOUMI, Khadija Al
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.11
    • /
    • pp.843-851
    • /
    • 2020
  • This study focuses on identifying and prioritizing the broader performance measures for the service supply chains by taking the case of Majan Electricity Company, Sohar, in the Sultanate of Oman. For an examination of the uniformity of ultimate objectives and the priorities therein, two strata of respondents with a total of fourteen respondents were approached for their valuable insights. Suitable structured instruments were personally administered to elicit the insightful and worthy responses. The two multi-criteria decision-making techniques, namely, the Fuzzy Analytical Hierarchy Process and the Best-Worst Method were used to reach a meaningful prioritization of the identified and refined broader performance measurement dimensions. The results show that there exists a minor gap between the two respondents' groups in terms of their prioritizations. The major finding points to the difference in terms of the topmost priorities as revealed by the two set of respondents. For one group of respondents, the customer satisfaction matters the most, whereas for the other group, it is the overall profitability that matters the most. This gap against the utopian state assists in concluding that there is a requirement to reorient the employees so as to have a shared and common understanding of the organizational priorities.

Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS (GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kim, Jong-Sang;Kim, Min-Kyoung;Lee, Jae-Il;Suh, Yong-Jun;In, Moon-kyo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.